Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 49
Filter
1.
Scand J Med Sci Sports ; 33(11): 2230-2238, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37608446

ABSTRACT

Torsion of the Achilles tendon (AT) enhances tensile strength, but a high degree of torsion might also be a risk factor for Achilles tendinopathy, due to greater internal compression exerted during tensile loading. However, evidence supporting the grounds for this assumption is lacking. Hence, we aimed to investigate the impact of AT torsion type on intratendinous pressure. Eighteen human fresh frozen cadaveric legs were mounted in a testing rig and a miniature pressure catheter was placed through ultrasound-guided insertion in the midportion region of the AT. Intratendinous pressure was measured during a simulated straight-knee calf stretch and eccentric heel drop. The AT was then carefully dissected and classified into Type I (least), Type II (moderate), and Type III (extreme) torsion. Of the ATs examined, nine were found to have Type I torsion (50%), nine Type II (50%), and none Type III. It was found that the intratendinous pressure of the AT increased exponentially with ankle dorsiflexion during both exercises (p < 0.001) and that this increase was greater in ATs with Type II torsion than Type I torsion (p < 0.05). This study provides the first biomechanical data to support the hypothesis that in athletes with a high degree of torsion in the AT, the midportion area will experience more internal compression during exercise, for example, calf stretching and eccentric heel drops. Whether this phenomenon is also associated with an elevated risk for Achilles tendinopathy needs further prospective investigation.

2.
Strahlenther Onkol ; 198(6): 582-592, 2022 06.
Article in English | MEDLINE | ID: mdl-35403891

ABSTRACT

PURPOSE: Thiel embalming followed by freezing in the desired position and acquiring CT + MRI scans is expected to be the ideal approach to obtain accurate, enhanced CT data for delineation guideline development. The effect of Thiel embalming and freezing on MRI image quality is not known. This study evaluates the above-described process to obtain enhanced CT datasets, focusing on the integration of MRI data obtained from frozen, Thiel-embalmed specimens. METHODS: Three Thiel-embalmed specimens were frozen in prone crawl position and MRI scanning protocols were evaluated based on contrast detail and structural conformity between 3D renderings from corresponding structures, segmented on corresponding MRI and CT scans. The measurement error of the dataset registration procedure was also assessed. RESULTS: Scanning protocol T1 VIBE FS enabled swift differentiation of soft tissues based on contrast detail, even allowing a fully detailed segmentation of the brachial plexus. Structural conformity between the reconstructed structures on CT and MRI was excellent, with nerves and blood vessels imported into the CT scan never intersecting with the bones. The mean measurement error for the image registration procedure was consistently in the submillimeter range (range 0.77-0.94 mm). CONCLUSION: Based on the excellent MRI image quality and the submillimeter error margin, the procedure of scanning frozen Thiel-embalmed specimens in the treatment position to obtain enhanced CT scans is recommended. The procedure can be used to support the postulation of delineation guidelines, or for training deep learning algorithms, considering automated segmentations.


Subject(s)
Embalming , Magnetic Resonance Imaging , Cadaver , Embalming/methods , Humans , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed
3.
Medicina (Kaunas) ; 57(11)2021 Nov 19.
Article in English | MEDLINE | ID: mdl-34833492

ABSTRACT

Breast cancer is one of the most important causes of premature mortality among women and it is one of the most frequently diagnosed tumours worldwide. For this reason, routine screening for prevention and early diagnosis is important for the quality of life of patients. Breast cancer cells can enter blood and lymphatic capillaries, then metastasizing to the regional lymph nodes in the axilla and to both visceral and non-visceral sites. Rather than at the primary site, they seem to enter the systemic circulation mainly through the sentinel lymph node and the biopsy of this indicator can influence the axillary dissection during the surgical approach to the pathology. Furthermore, secondary lymphoedema is another important issue for women following breast cancer surgical treatment or radiotherapy. Considering these fundamental aspects, the present article aims to describe new methodological approaches to assess the anatomy of the lymphatic network in the axillary region, as well as the molecular and physiological control of lymphatic vessel function, in order to understand how the lymphatic system contributes to breast cancer disease. Due to their clinical implications, the understanding of the molecular mechanisms governing lymph node metastasis in breast cancer are also examined. Beyond the investigation of breast lymphatic networks and lymphatic molecular mechanisms, the discovery of new effective anti-lymphangiogenic drugs for future clinical settings appears essential to support any future development in the treatment of breast cancer.


Subject(s)
Breast Neoplasms , Axilla , Breast Neoplasms/surgery , Female , Humans , Lymph Node Excision , Lymph Nodes , Lymphatic System , Quality of Life , Sentinel Lymph Node Biopsy
4.
Sci Rep ; 11(1): 22529, 2021 11 18.
Article in English | MEDLINE | ID: mdl-34795352

ABSTRACT

Our recently developed prone crawl position (PCP) for radiotherapy of breast cancer patients with lymphatic involvement showed promising preliminary data and it is being optimized for clinical use. An important aspect in this process is making new, position specific delineation guidelines to ensure delineation (for treatment planning) is uniform across different centers. The existing ESTRO and PROCAB guidelines for supine position (SP) were adapted for PCP. Nine volunteers were MRI scanned in both SP and PCP. Lymph node regions were delineated in SP using the existing ESTRO and PROCAB guidelines and were then translated to PCP, based on the observed changes in reference structure position. Nine PCP patient CT scans were used to verify if the new reference structures were consistently identified and easily applicable on different patient CT scans. Based on these data, a team of specialists in anatomy, CT- and MRI radiology and radiation oncology postulated the final guidelines. By taking the ESTRO and PROCAB guidelines for SP into account and by using a relatively big number of datasets, these new PCP specific guidelines incorporate anatomical variability between patients. The guidelines are easily and consistently applicable, even for people with limited previous experience with delineations in PCP.


Subject(s)
Breast Neoplasms/radiotherapy , Lymph Nodes/pathology , Patient Positioning/methods , Radiotherapy/standards , Breast/pathology , Female , Humans , Lymphatic Metastasis/pathology , Magnetic Resonance Imaging/methods , Practice Guidelines as Topic , Radiotherapy Planning, Computer-Assisted/methods , Supine Position , Tomography, X-Ray Computed
6.
Ann Anat ; 232: 151562, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32562859

ABSTRACT

BACKGROUND: Visualizing the lymphatic system and recording the spatial relations between the subclavian lymphatic trunk (SLT) and the surrounding anatomical structures will improve radiotherapy treatment planning for breast cancer patients with lymphatic involvement. An experimental approach to retrogradely fill the SLT with contrast agent was explored. METHODS: Six Thiel embalmed specimens were bilaterally dissected in the cervical and clavicular region to optimize the new experimental approach. A conservative dissection with minimum distortion of spatial relations between different anatomical structures was developed. A pressure reservoir was created inside the venous angle to allow retrograde filling of the SLT under the influence of time and pressure. RESULTS: The new methodology proved feasible, showing successful pressure build-up inside the venous reservoir, resulting in filling of the proximal end of the subclavian lymphatic trunk. The pressures needed to significantly fill the subclavian lymphatic trunk proved to be higher than the pressures that the venous walls could withstand. CONCLUSIONS: Thiel embalmed specimens proved useful for optimizing the experimental approach, but the embalming products could have negatively affected the vessel strength. The authors suggest that their method will be applied on fresh frozen specimens in future studies, to obtain SLT filling up to the axillary lymphatic plexus. Our findings also pointed out that there is still a lot to be learned about the anatomical variability of the SLT and its termination sites. The detailed description of our experimental approach offers valuable information for future lymphatic mapping studies.


Subject(s)
Contrast Media/administration & dosage , Lymphatic System/anatomy & histology , Feasibility Studies , Humans
7.
Anat Sci Int ; 95(3): 399-407, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32144646

ABSTRACT

The aim of this study was to determine the effect of Thiel embalming on the biomechanical properties of nerve tissue, to validate the use of Thiel embalmed bodies as a reliable model system for obtaining biomechanical data to supplement neurodynamic models, for anesthesiological and neurosurgical training and for future preclinical test set-ups involving nerve tissue. Upon the arrival of a body at the anatomy department, a fresh median nerve was harvested, the harvest site was sutured and following the Thiel embalming procedure the Thiel embalmed median nerve of the opposing wrist was harvested. Micro CT was performed to establish the cross-sectional area and biomechanical tensile testing was performed to compare the Young's modulus/elasticity of fresh frozen and Thiel embalmed nerves. Thiel embalming did not cause a significant difference in elasticity when comparing Thiel embalmed and fresh frozen specimens. A correlation was found between the cross-sectional area of Thiel embalmed nerve specimens and their Young's modulus. Thiel embalming does not significantly alter the elasticity of nerve tissue compared to fresh frozen nerve tissue. Similar shapes were observed when comparing the stress/strain curves of both specimen types. This indicates that Thiel embalmed nerve tissue is a viable alternative for using fresh frozen specimens when investigating biomechanical principles/mechanisms. Some specimens showed a reversed trend in Young's modulus that could be related to slight differences in embalming outcome, so caution is advised when Thiel embalmed specimens are used to obtain raw numerical data for direct application in the clinic.


Subject(s)
Embalming/methods , Freezing , Median Nerve/physiology , Tissue Preservation/methods , Biomechanical Phenomena , Humans , Median Nerve/diagnostic imaging
8.
Comput Methods Biomech Biomed Engin ; 23(1): 23-32, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31818133

ABSTRACT

The goal of this study was to report deep squat hip kinetics in young, athletic adults using a personalized numerical model solution based on inverse dynamics. Thirty-five healthy subjects underwent deep squat motion capture acquisitions and MRI scans of the lower extremities. Musculoskeletal models were personalized using each subject's lower limb anatomy. The average peak hip joint reaction force was 274 percent bodyweight. Average peak hip and knee flexion angles were 107° and 112° respectively. These new findings show that deep squatting kinetics in the younger population differ substantially from the previously reported in vivo data in older subjects.


Subject(s)
Hip Joint/physiology , Posture/physiology , Sports , Adolescent , Adult , Aged , Biomechanical Phenomena , Female , Humans , Kinetics , Male , Motion , Range of Motion, Articular/physiology , Reproducibility of Results , Young Adult
9.
Anat Rec (Hoboken) ; 303(9): 2392-2401, 2020 09.
Article in English | MEDLINE | ID: mdl-31674142

ABSTRACT

In order to provide an alternative for fresh frozen specimens to map the lymphatic system, the possibility of using Thiel embalmed specimens for this purpose was explored. The thoracic duct was used to investigate if retrograde injection of contrast agent was possible in Thiel embalmed specimens and to verify up to which diameter lymphatic vessels could be reconstructed and rendered in 3D, after CT scanning. 3D renderings were used for digital diameter measurement, to determine the smallest lymphatic diameter that could still be visualized on CT. Finally, the contrast agent concentration was adapted based on the findings during image reconstruction and 3D rendering. All Thiel embalmed specimens proved suitable for retrograde injection of contrast agent into the thoracic duct and all 3D renderings perfectly overlapped with the dissection pictures. The smallest diameter of contrast filled lymphatics that could be reconstructed and rendered in 3D was 0.23 mm. Increasing the concentration of barium sulfate from 10 to 50% reduced the postprocessing time needed to render a "clean" 3D structure, following automatic segmentation based on grey values, by 95%. The authors would recommend the use of Thiel embalmed specimens for mapping the lymphatic system, as these specimens do not show the rapid putrefaction that occurs in fresh frozen specimens, thus greatly facilitating experimental planning.


Subject(s)
Cadaver , Embalming/methods , Lymphatic System/pathology , Dissection , Humans
10.
Anat Rec (Hoboken) ; 302(10): 1681-1695, 2019 10.
Article in English | MEDLINE | ID: mdl-31087787

ABSTRACT

This review intends to rekindle efforts to map the lymphatic system by using a more modern approach, based on medical imaging. The structure, function, and pathologies associated with the lymphatic system are first discussed to highlight the need for more accurately mapping the lymphatic system. Next, the need for an interdisciplinary approach, with a central role for the anatomist, to come up with better maps of the lymphatic system is emphasized. The current approaches on lymphatic system research involving medical imaging will be discussed and suggestions will be made for an all-encompassing effort to thoroughly map the entire lymphatic system. A first-hand account of our integration as anatomists in the radiotherapy department is given as an example of interdisciplinary collaboration. From this account, it will become clear that the interdisciplinary collaboration of anatomists in the clinical disciplines involved in lymphatic system research/treatment still holds great promise in terms of improving clinical regimens that are currently being employed. As such, we hope that our fellow anatomists will join us in an interdisciplinary effort to map the lymphatic system, because this could, in a relatively short timeframe, provide improved treatment options for patients with cancer or lymphatic pathologies all over the world. Anat Rec, 302:1681-1695, 2019. © 2019 American Association for Anatomy.


Subject(s)
Biomedical Research/organization & administration , Imaging, Three-Dimensional , Interdisciplinary Communication , Lymphatic System/anatomy & histology , Anatomists/organization & administration , Dissection , Humans , Lymphatic System/diagnostic imaging , Radiology/organization & administration
11.
J Orthop Res ; 37(5): 1101-1109, 2019 05.
Article in English | MEDLINE | ID: mdl-30839121

ABSTRACT

Sacroiliac joint (SIJ) biomechanics have been described in both in vitro and in vivo studies. A standard for joint coordinate systems has been created by the International Society of Biomechanics for most of the joints in the human body. However, a standardized joint coordinate system for sacroiliac joint motion analysis is currently still lacking. This impedes the comparison across studies and hinders communication among scientists and clinicians. As SIJ motion is reported to be quite limited, a proper standardization and reproducibility of this procedure is essential for the interpretation of future biomechanical SIJ studies. This paper proposes a joint coordinate system for the analysis of sacroiliac joint motion, based on the procedure developed by Grood and Suntay, using semi-automated anatomical landmarks on 3D joint surfaces. This coordinate system offers high inter-rater reliability and aspires to a more intuitive representation of biomechanical data, as it is aligned with SIJ articular surfaces. This study aims to encourage further reflection and debate on biomechanical data representation, in order to facilitate interpretation of SIJ biomechanics and improve communication between researchers and clinicians. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res.


Subject(s)
Anatomic Landmarks , Sacroiliac Joint/anatomy & histology , Adult , Biomechanical Phenomena , Humans
13.
Appl Ergon ; 72: 48-57, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29885727

ABSTRACT

Although many authors stated that a user-centred design approach in medical device development has added values, the most common research approach within healthcare is evidence-based medicine, which tend to focus on functional data rather than patient wellbeing and comfort. End user comfort is well addressed in literature for commercial products such as seats and hand tools but no data was found for medical devices. A commercial patient support device for breast radiotherapy was analysed and a relation was found between discomfort and uncompensated internal body forces. Derived from CT-images, simplified patient free-body diagrams were analysed and pain and comfort evaluated. Subsequently, a new patient position was established and prototypes were developed. Patient comfort- and prototype optimization was done through iterative prototyping. With this approach, we were able to compensate all internal body forces and establish a force neutral patient free-body diagram. This resulted in comfortable patient positioning and favourable medical results.


Subject(s)
Breast Neoplasms/radiotherapy , Equipment Design/adverse effects , Musculoskeletal Pain/prevention & control , Patient Comfort , Patient Positioning , Radiotherapy/instrumentation , Axilla , Female , Humans , Lymph Nodes , Musculoskeletal Pain/etiology , Prone Position , Tomography, X-Ray Computed , Torso/diagnostic imaging
16.
J Appl Clin Med Phys ; 18(4): 200-205, 2017 Jul.
Article in English | MEDLINE | ID: mdl-28649708

ABSTRACT

PURPOSE: To investigate crawl position with the arm at the treated side alongside the body and at the opposite side above the head for prone treatment in patients requiring breast and regional lymph node irradiation. METHODS: Patient support devices for crawl position were built for CT simulation and treatment. An asymmetric fork design resulted from an iterative process of prototype construction and testing. The fork's large horn supports the hemi-thorax, shoulder, and elevated arm at the nontreated side and the head. The short, narrow horn supports the arm at the treated side. Between both horns, the treated breast and its regional lymph nodes are exposed. Endpoints were pain, comfort, set-up precision, beam access to the breast and lymph nodes, and plan dose metrics. Pain and comfort were tested by volunteers (n = 9); set-up precision, beam access, and plan dose metrics were tested by means of a patient study (n = 10). The AIO™ (Orfit, Wijnegem, Belgium) prone breastboard (AIO™) was used as a reference regarding comfort and set-up precision. RESULTS: Pain at the sternum, the ipsilateral shoulder, upper arm, and neck was lower in crawl position than with bilateral arm elevation on AIO™. Comfort and set-up precision were better on the crawl prototype than on AIO™. In crawl position, beam directions in the coronal and near-sagittal planes have access to the breast or regional lymph nodes without traversing device components. Plan comparison between supine and crawl positions showed better dose homogeneity for the breast and lymph node targets and dose reductions to all organs at risk for crawl position. CONCLUSIONS: Radiation therapy for breast and regional lymph nodes in crawl position is feasible. Good comfort and set-up precision were demonstrated. Planning results support the hypothesis that breast and regional lymph nodes can be treated in crawl position with less dose to organs at risk and equal or better dose distribution in the target volumes than in supine position. The crawl technique is a candidate methodology for further investigation for patients requiring breast and regional lymph node irradiation.


Subject(s)
Breast Neoplasms/radiotherapy , Lymphatic Irradiation , Patient Positioning/methods , Prone Position , Female , Humans , Lymph Nodes , Pain, Procedural/etiology , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
17.
Radiat Oncol ; 12(1): 89, 2017 May 26.
Article in English | MEDLINE | ID: mdl-28549483

ABSTRACT

BACKGROUND: Prone whole breast irradiation (WBI) leads to reduced heart and lung doses in breast cancer patients receiving adjuvant radiotherapy. In this feasibility trial, we investigated the prone position for whole breast + lymph node irradiation (WB + LNI). METHODS: A new support device was developed for optimal target coverage, on which patients are positioned in a position resembling a phase from the crawl swimming technique (prone crawl position). Five left sided breast cancer patients were included and simulated in supine and prone position. For each patient, a treatment plan was made in prone and supine position for WB + LNI to the whole axilla and the unoperated part of the axilla. Patients served as their own controls for comparing dosimetry of target volumes and organs at risk (OAR) in prone versus in supine position. RESULTS: Target volume coverage differed only slightly between prone and supine position. Doses were significantly reduced (P < 0.05) in prone position for ipsilateral lung (Dmean, D2, V5, V10, V20, V30), contralateral lung (Dmean, D2), contralateral breast (Dmean, D2 and for total axillary WB + LNI also V5), thyroid (Dmean, D2, V5, V10, V20, V30), oesophagus (Dmean and for partial axillary WB + LNI also D2 and V5), skin (D2 and for partial axillary WB + LNI V105 and V107). There were no significant differences for heart and humeral head doses. CONCLUSIONS: Prone crawl position in WB + LNI allows for good breast and nodal target coverage with better sparing of ipsilateral lung, thyroid, contralateral breast, contralateral lung and oesophagus when compared to supine position. There is no difference in heart and humeral head doses. TRIAL REGISTRATION: No trial registration was performed because there were no therapeutic interventions.


Subject(s)
Lymph Nodes/radiation effects , Lymphatic Irradiation/methods , Organs at Risk/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Unilateral Breast Neoplasms/radiotherapy , Axilla , Feasibility Studies , Female , Follow-Up Studies , Humans , Lymph Nodes/pathology , Prognosis , Prone Position , Radiotherapy Dosage , Radiotherapy, Intensity-Modulated/methods , Supine Position
18.
Phys Med ; 36: 32-37, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28410683

ABSTRACT

PURPOSE: The evaluation of clinical image quality (IQ) is important to optimize CT protocols and to keep patient doses as low as reasonably achievable. Considering the significant amount of effort needed for human observer studies, automatic IQ tools are a promising alternative. The purpose of this study was to evaluate automatic IQ assessment in chest CT using Thiel embalmed cadavers. METHODS: Chest CT's of Thiel embalmed cadavers were acquired at different exposures. Clinical IQ was determined by performing a visual grading analysis. Physical-technical IQ (noise, contrast-to-noise and contrast-detail) was assessed in a Catphan phantom. Soft and sharp reconstructions were made with filtered back projection and two strengths of iterative reconstruction. In addition to the classical IQ metrics, an automatic algorithm was used to calculate image quality scores (IQs). To be able to compare datasets reconstructed with different kernels, the IQs values were normalized. RESULTS: Good correlations were found between IQs and the measured physical-technical image quality: noise (ρ=-1.00), contrast-to-noise (ρ=1.00) and contrast-detail (ρ=0.96). The correlation coefficients between IQs and the observed clinical image quality of soft and sharp reconstructions were 0.88 and 0.93, respectively. CONCLUSIONS: The automatic scoring algorithm is a promising tool for the evaluation of thoracic CT scans in daily clinical practice. It allows monitoring of the image quality of a chest protocol over time, without human intervention. Different reconstruction kernels can be compared after normalization of the IQs.


Subject(s)
Quality Assurance, Health Care/methods , Radiography, Thoracic , Tomography, X-Ray Computed , Automation , Cadaver , Humans , Phantoms, Imaging , Radiation Dosage , Signal-To-Noise Ratio
19.
J Shoulder Elbow Surg ; 26(3): 490-496, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28081995

ABSTRACT

BACKGROUND: For many years, researchers have attempted to describe shoulder motions by using different mathematical methods. The aim of this study was to describe a procedure to quantify clavicular motion. METHODS: The procedure proposed for the kinematic analysis consists of 4 main processes: 3 transcortical pins in the clavicle, motion capture, obtaining 3-dimensional bone models, and data processing. RESULTS: Clavicular motion by abduction (30° to 150°) and flexion (55° to 165°) were characterized by an increment of retraction of 27° to 33°, elevation of 25° to 28°, and posterior rotation of 14° to 15°, respectively. In circumduction, clavicular movement described an ellipse, which was reflected by retraction and elevation. Kinematic analysis shows that the articular surfaces move by simultaneously rolling and sliding on the convex surface of the sternum for the 3 movements of abduction, flexion, and circumduction. CONCLUSION: The use of 3 body landmarks in the clavicle and the direct measurement of bone allowed description of the osteokinematic and arthrokinematic movement of the clavicle.


Subject(s)
Clavicle/physiology , Computer Simulation , Imaging, Three-Dimensional , Anatomic Landmarks , Biomechanical Phenomena/physiology , Cadaver , Female , Humans , Middle Aged , Range of Motion, Articular/physiology , Scapula/physiology , Sternum/physiology , Tomography, X-Ray Computed
20.
Knee Surg Sports Traumatol Arthrosc ; 25(6): 1720-1730, 2017 06.
Article in English | MEDLINE | ID: mdl-27671286

ABSTRACT

PURPOSE: To determine the mechanisms and extents of popliteus impingements before and after TKA and to investigate the influence of implant sizing. The hypotheses were that (1) popliteus impingements after TKA may occur at both the tibia and the femur, and (2) even with an apparently well-sized prosthesis, popliteal tracking during knee flexion is modified compared to the preoperative situation. METHODS: The location of the popliteus in three cadaver knees was measured using computed tomography, before and after implantation of plastic TKA replicas, by injecting the tendon with radiopaque liquid. The pre- and post-operative positions of the popliteus were compared from full extension to deep flexion using normosized, oversized, and undersized implants (one size increments). RESULTS: At the tibia, TKA caused the popliteus to translate posteriorly, mostly in full extension: 4.1 ± 2 mm for normosized implants, and 15.8 ± 3 mm with oversized implants, but no translations were observed when using undersized implants. At the femur, TKA caused the popliteus to translate laterally at deeper flexion angles, peaking between 80° and 120°: 2 ± 0.4 mm for normosized implants and 2.6 ± 0.5 mm with oversized implants. Three-dimensional analysis revealed prosthetic overhang at the posterosuperior corner of normosized and oversized femoral components (respectively, up to 2.9 mm and 6.6 mm). CONCLUSIONS: A well-sized tibial component modifies popliteal tracking, while an undersized tibial component maintains more physiologic patterns. Oversizing shifts the popliteus considerably throughout the full arc of motion. This study suggests that both femoro- and tibio-popliteus impingements could play a role in residual pain and stiffness after TKA.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Joint/surgery , Knee Prosthesis/adverse effects , Ligaments, Articular , Arthroplasty, Replacement, Knee/methods , Cadaver , Humans , Joint Instability , Knee Joint/diagnostic imaging , Postoperative Complications , Range of Motion, Articular , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...