Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Faraday Discuss ; 153: 227-35; discussion 293-319, 2011.
Article in English | MEDLINE | ID: mdl-22452083

ABSTRACT

Identifying complex molecules often entails detection of multiple vibrational resonances, especially in the case of mixtures. Phase shaping of broadband pump and probe pulses allows for the coherent superposition of several resonances, such that specific molecules can be detected directly and with high selectivity. Our particular implementation of coherent anti-Stokes Raman scattering (CARS) spectroscopy and imaging employs broadband pump and probe fields in combination with a narrowband Stokes field. We describe our approach for combining spectral phase shaping and closed-loop optimization strategies to perform chemically-selective microscopy. To predict the optimal excitation profile we employ evolutionary algorithms that use the vibrational phase responses of five distinct molecules with overlapping resonances and investigate the effect of phase instability on the optimization. We have recently shown that modified polynomials and orthogonal rational functions can give rise to improved contours for CARS fitness landscapes. Now, by considering the landscapes associated with different basis sets, we introduce two figures of merit to quantitatively rank basis functions in terms of their "appropriateness" for modeling nonlinear phase-shaped processes.

2.
Opt Express ; 16(11): 7985-96, 2008 May 26.
Article in English | MEDLINE | ID: mdl-18545508

ABSTRACT

By spectral phase shaping of both the pump and probe pulses in coherent anti-Stokes Raman scattering (CARS) spectroscopy we demonstrate the extraction of the frequencies, bandwidths and relative cross sections of vibrational lines. We employ a tunable broadband Ti:Sapphire laser synchronized to a ps-Nd:YVO mode locked laser. A high resolution spectral phase shaper allows for spectroscopy with a precision better than 1 cm(-1) in the high frequency region around 3000 cm(-1). We also demonstrate how new spectral phase shaping strategies can amplify the resonant features of isolated vibrations to such an extent that spectroscopy and microscopy can be done at high resolution, on the integrated spectral response without the need for a spectrograph.


Subject(s)
Computer-Aided Design , Lasers , Models, Theoretical , Optics and Photonics/instrumentation , Refractometry/instrumentation , Spectrum Analysis, Raman/instrumentation , Computer Simulation , Equipment Design , Equipment Failure Analysis , Spectrum Analysis, Raman/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...