Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Scanning ; 34(2): 90-100, 2012.
Article in English | MEDLINE | ID: mdl-22544486

ABSTRACT

Although helium ion microscopy (HIM) was introduced only a few years ago, many new application fields are emerging. The connecting factor between these novel applications is the unique interaction of the primary helium ion beam with the sample material at and just below its surface. In particular, the HIM secondary electron signal stems from an area that is extremely well localized around the point of incidence of the primary beam. This makes the HIM well suited for both high-resolution imaging and high-resolution nanofabrication. Another advantage in nanofabrication is the low ion backscattering fraction, which leads to a weak proximity effect. The subnanometer probe size and the unique beam-materials interactions have opened new areas of research. This review presents a selection of studies conducted on a single instrument. The selection encompasses applications ranging from imaging to nanofabrication and from fundamental academic research to applied industrial developments.


Subject(s)
Helium , Ions , Microscopy/instrumentation , Microscopy/methods , Nanotechnology/instrumentation , Nanotechnology/methods , Netherlands
2.
Microsc Microanal ; 17(4): 624-36, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21676276

ABSTRACT

In recent years, novel ion sources have been designed and developed that have enabled focused ion beam machines to go beyond their use as nano-fabrication tools. Secondary electrons are usually taken to form images, for their yield is high and strongly dependent on the surface characteristics, in terms of chemical composition and topography. In particular, the secondary electron yield varies characteristically with the angle formed by the beam and the direction normal to the sample surface in the point of impact. Knowledge of this dependence, for different ion/atom pairs, is thus the first step toward a complete understanding of the contrast mechanism in scanning ion microscopy. In this article, experimentally obtained ion-induced secondary electron yields as a function of the incidence angle of the beam on flat surfaces of Al and Cr are reported, for usual conditions in Ga+ and He+ microscopes. The curves have been compared with models and simulations, showing a good agreement for most of the angle range; deviations from the expected behavior are addressed and explanations are suggested. It appears that the maximum value of the ion-induced secondary electron yield is very similar in all the studied cases; the yield range, however, is consistently larger for helium than for gallium, which partially explains the enhanced topographical contrast of helium microscopes over the gallium focused ion beams.

3.
Nanotechnology ; 21(45): 455302, 2010 Nov 12.
Article in English | MEDLINE | ID: mdl-20947951

ABSTRACT

A 25 keV focused helium ion beam has been used to grow PtC nanopillars on a silicon substrate by beam-induced decomposition of a (CH(3))(3)Pt(C(P)CH(3)) precursor gas. The ion beam diameter was about 1 nm. The observed relatively high growth rates suggest that electronic excitation is the dominant mechanism in helium ion-beam-induced deposition. Pillars grown at low beam currents are narrow and have sharp tips. For a constant dose, the pillar height decreases with increasing current, pointing to depletion of precursor molecules at the beam impact site. Furthermore, the diameter increases rapidly and the total pillar volume decreases slowly with increasing current. Monte Carlo simulations have been performed with realistic values for the fundamental deposition processes. The simulation results are in good agreement with experimental observations. In particular, they reproduce the current dependences of the vertical and lateral growth rates and of the volumetric deposition efficiency. Furthermore, the simulations reveal that the vertical pillar growth is due to type-1 secondary electrons and primary ions, while the lateral outgrowth is due to type-2 secondary electrons and scattered ions.

SELECTION OF CITATIONS
SEARCH DETAIL
...