1.
Lancet Infect Dis ; 20(7): e173-e179, 2020 07.
Article in English | MEDLINE | ID: mdl-32502432

ABSTRACT

Syphilis is caused by a spirochaete bacterium called Treponema pallidum. Vertical transmission of spirochaetes can lead to congenital infection of the fetus in pregnant women who are inadequately treated or not treated at all, causing various clinical manifestations including stillbirth and neonatal death, cutaneous and visceral manifestations, or asymptomatic infection. We present a severe case of syphilis in a 3-month-old boy with skin lesions, portal hypertension, and anaemia. Because the mother was tested negative for syphilis antibodies at 16 weeks of gestation, a diagnosis of congenital syphilis was initially not considered. This case shows that transmission of T pallidum can still occur in high-income countries with a high rate of antenatal screening. Early recognition might be hampered if physicians do not consider congenital syphilis as a possible diagnosis. Congenital syphilis should be considered in any severe and diagnostically challenging infectious disease case, even in the context of negative antenatal screening.


Subject(s)
Syphilis, Congenital/diagnosis , Syphilis, Congenital/therapy , Adult , Female , Humans , Infant , Male , Syphilis, Congenital/pathology
2.
J Endovasc Ther ; 13(6): 762-9, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17154702

ABSTRACT

PURPOSE: To report the results of in vitro hydrostatic bench testing of a new vein-stent combination to correct deep venous incompetence. METHODS: Twelve valves were constructed from a modified Palmaz stent encased in a segment of great saphenous vein harvested from patients during routine varicose vein surgery. An in vitro flow circuit was set up to evaluate opening and closing pressures (in cm H(2)O), and the valve was subsequently subjected to repetitive cycles of increasing prograde flow and reflux pressures. Duplex scanning was used to evaluate valve closure time and detect any possible reflux. RESULTS: The valve mechanism required only 1 to 3 cm H(2)O for opening and 2 to 4 cm H(2)O for closing. Prograde flow of up to 1000 mL/min passed easily through this valve, which remained competent with reflux pressures up to 180 cm H(2)O. Mean valve closure time was 0.15+/-0.07 seconds. Unligated side branches or damage from dissection impaired the competence of 3 valves. CONCLUSION: This new vein-stent valve functions as a normal deep vein valve, requiring only minimal pressures for opening and closing. It allows high flow passage and still remains competent at high reflux pressures. This valve may provide a minimally invasive solution for the correction of deep venous incompetence using autologous material. Further in vivo evaluation will be mandatory.


Subject(s)
Angioplasty, Balloon/methods , Blood Vessel Prosthesis Implantation/methods , Saphenous Vein/transplantation , Stents , Venous Insufficiency/therapy , Angioplasty, Balloon/adverse effects , Blood Vessel Prosthesis Implantation/adverse effects , Equipment Failure Analysis , Humans , Hydrostatic Pressure , Leg/blood supply , Materials Testing , Models, Anatomic , Models, Cardiovascular , Prosthesis Design , Saphenous Vein/diagnostic imaging , Stents/adverse effects , Stents/standards , Time Factors , Transplantation, Autologous/methods , Ultrasonography, Doppler, Duplex , Venous Insufficiency/diagnostic imaging