1.
Front Robot AI ; 9: 887261, 2022.
Article in English | MEDLINE | ID: mdl-35875703

ABSTRACT

Many robust state-of-the-art localization methods rely on pose-space sample sets that are evaluated against individual sensor measurements. While these methods can work effectively, they often provide limited mechanisms to control the amount of hypotheses based on their similarity. Furthermore, they do not explicitly use associations to create or remove these hypotheses. We propose a global localization strategy that allows a mobile robot to localize using explicit symbolic associations with annotated geometric features. The feature measurements are first combined locally to form a consistent local feature map that is accurate in the vicinity of the robot. Based on this local map, an association tree is maintained that pairs local map features with global map features. The leaves of the tree represent distinct hypotheses on the data associations that allow for globally unmapped features appearing in the local map. We propose a registration step to check if an association hypothesis is supported. Our implementation considers a robot equipped with a 2D LiDAR and we compare the proposed method to a particle filter. We show that maintaining a smaller set of data association hypotheses results in better performance and explainability of the robot's assumptions, as well as allowing more control over hypothesis bookkeeping. We provide experimental evaluations with a physical robot in a real environment using an annotated geometric building model that contains only the static part of the indoor scene. The result shows that our method outperforms a particle filter implementation in most cases by using fewer hypotheses with more descriptive power.

2.
Physiol Meas ; 35(4): 687-702, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24622168

ABSTRACT

The aim of this study was to develop an integrated mock circulation system that functions in a physiological manner for testing cardiovascular devices under well-controlled circumstances. In contrast to previously reported mock loops, the model includes a systemic, pulmonary, and coronary circulation, an elaborate heart contraction model, and a realistic heart rate control model. The behavior of the presented system was tested in response to changes in left ventricular contractile states, loading conditions, and heart rate. For validation purposes, generated hemodynamic parameters and responses were compared to literature. The model was implemented in a servo-motor driven mock loop, together with a relatively simple lead-lag controller. The pressure and flow signals measured closely mimicked human pressure under both physiological and pathological conditions. In addition, the system's response to changes in preload, afterload, and heart rate indicate a proper implementation of the incorporated feedback mechanisms (frequency and cardiac function control). Therefore, the presented mock circulation allows for generic in vitro testing of cardiovascular devices under well-controlled circumstances.


Subject(s)
Heart-Assist Devices , Models, Cardiovascular , Algorithms , Blood Pressure/physiology , Computer Simulation , Heart Function Tests , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...