Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Article in English | MEDLINE | ID: mdl-38795109

ABSTRACT

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.

2.
JACC Cardiovasc Imaging ; 17(4): 428-440, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38569793

ABSTRACT

Structural heart disease interventions rely heavily on preprocedural planning and simulation to improve procedural outcomes and predict and prevent potential procedural complications. Modeling technologies, namely 3-dimensional (3D) printing and computational modeling, are nowadays increasingly used to predict the interaction between cardiac anatomy and implantable devices. Such models play a role in patient education, operator training, procedural simulation, and appropriate device selection. However, current modeling is often limited by the replication of a single static configuration within a dynamic cardiac cycle. Recognizing that health systems may face technical and economic limitations to the creation of "in-house" 3D-printed models, structural heart teams are pivoting to the use of computational software for modeling purposes.


Subject(s)
Cardiac Surgical Procedures , Heart Diseases , Humans , Predictive Value of Tests , Cardiac Surgical Procedures/methods , Computer Simulation , Heart Diseases/diagnostic imaging , Heart Diseases/therapy , Software , Printing, Three-Dimensional
3.
JACC Case Rep ; 29(3): 102193, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38361565

ABSTRACT

Left ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography-derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation (ASA) can mitigate neo-LVOTO risk. We report a case of sequential ASA of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.

4.
JACC Cardiovasc Interv ; 16(16): 1974-1985, 2023 08 28.
Article in English | MEDLINE | ID: mdl-37648345

ABSTRACT

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with pure severe native aortic valve regurgitation (NAVR) has been associated with suboptimal results. The available evidence concerns mostly outdated transcatheter heart valves (THVs). OBJECTIVES: The aim of this study was to investigate the performance of new-generation THVs in patients treated for pure severe NAVR. METHODS: The PANTHEON (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve) study retrospectively included patients who underwent TAVR with currently available devices (both self-expanding [SE] and balloon expandable [BE]) for severe NAVR. Technical and device success rates as well as a composite of all-cause mortality and heart failure rehospitalization at 1 year were evaluated. The rate and clinical consequences of acute transcatheter valve embolization or migration (TVEM) were also considered. RESULTS: A total of 201 patients were included. Overall technical and device success rates were 83.6% and 76.1%, respectively, and did not differ between SE and BE devices. These figures were due mostly to TVEM occurrence (14.6% vs 16.1%; P = 0.47) and residual moderate or greater aortic regurgitation (9.2% vs 10.1%; P = 0.87). Patients who experienced TVEM compared with those without TVEM had a significantly higher incidence of the composite endpoint at 1 year (25.7% vs 15.8%; P = 0.05). CONCLUSIONS: Despite improved THV platforms and techniques, TAVR for pure severe NAVR remains a challenging procedure, with significant risk for TVEM. SE and BE platforms demonstrated comparable performance in this setting. (Performance of Currently Available Transcatheter Aortic Valve Platforms in Inoperable Patients With Pure Aortic Regurgitation of a Native Valve [PANTHEON]; NCT05319171).


Subject(s)
Aortic Valve Insufficiency , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Retrospective Studies , Treatment Outcome
5.
Struct Heart ; 6(5): 100084, 2022 Oct.
Article in English | MEDLINE | ID: mdl-37288055

ABSTRACT

Background: Transcatheter valvular interventions affect cardiac and hemodynamic physiology by changing ventricular (un-)loading and metabolic demand as reflected by cardiac mechanoenergetics. Real-time quantifications of these changes are scarce. Pressure-volume loop (PVL) monitoring appraises both load-dependent and load-independent compounds of cardiac physiology including myocardial work, ventricular unloading, and ventricular-vascular interactions. The primary objective is to describe changes in physiology induced by transcatheter valvular interventions using periprocedural invasive biventricular PVL monitoring. The study hypothesizes transcatheter valve interventions modify cardiac mechanoenergetics that translate into improved functional status at 1-month and 1-year follow-up. Methods: In this single-center prospective study, invasive PVL analysis is performed in patients undergoing transcatheter aortic valve replacement or tricuspid or mitral transcatheter edge-to-edge repair. Clinical follow-up is per standard of care at 1 and 12 months. This study aims to include 75 transcatheter aortic valve replacement patients and 41 patients in both transcatheter edge-to-edge repair cohorts. Results: The primary outcome is the periprocedural change in stroke work, potential energy, and pressure-volume area (mmHg mL-1). The secondary outcomes comprise changes in a myriad of parameters obtained by PVL measurements, including ventricular volumes and pressures and the end-systolic elastance-effective arterial elastance ratio as a reflection of ventricular-vascular coupling. A secondary endpoint associates these periprocedural changes in cardiac mechanoenergetics with functional status at 1 month and 1 year. Conclusions: This prospective study aims to elucidate the fundamental changes in cardiac and hemodynamic physiology during contemporary transcatheter valvular interventions.

6.
Int J Cardiovasc Imaging ; 34(5): 743-749, 2018 May.
Article in English | MEDLINE | ID: mdl-29234934

ABSTRACT

Left ventricular (LV) diastolic dysfunction is one of the important mechanisms responsible for symptoms in patients with heart failure. The aim of the current study was to identify parameters that may be used to detect early signs of LV diastolic dysfunction in diabetic pigs on a high fat diet, using conventional and speckle tracking echocardiography. The study population consisted of 16 healthy Göttingen minipigs and 18 minipigs with experimentally induced metabolic dysfunction. Echocardiography measurements were performed at baseline and 3-month follow-up. The ratio of peak early (E) and late filling velocity (E/A ratio) and the ratio of E and the velocity of the mitral annulus early diastolic wave (E/Em ratio) did not change significantly in both groups. Peak untwisting velocity decreased in the metabolic dysfunction group (- 30.1 ± 18.5 vs. - 23.4 ± 15.5 °/ms) but not in controls (- 38.1 ± 23.6 vs. - 42.2 ± 23.0 °/ms), being significantly different between the groups at the 3-month time point (p < 0.05). In conclusion, whereas E/A ratio and E/Em ratio did not change significantly after 3 months of metabolic dysfunction, peak untwisting velocity was significantly decreased. Hence, peak untwisting velocity may serve as an important marker to detect early changes of LV diastolic dysfunction.


Subject(s)
Diabetes Mellitus, Experimental/complications , Echocardiography, Doppler , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left , Animals , Biomechanical Phenomena , Diabetes Mellitus, Experimental/diagnosis , Diastole , Early Diagnosis , Predictive Value of Tests , Swine , Swine, Miniature , Time Factors , Ventricular Dysfunction, Left/etiology , Ventricular Dysfunction, Left/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...