Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Neuroradiology ; 64(6): 1145-1156, 2022 Jun.
Article in English | MEDLINE | ID: mdl-34719725

ABSTRACT

INTRODUCTION: In order to augment the certainty of the radiological interpretation of "possible microbleeds" after traumatic brain injury (TBI), we assessed their longitudinal evolution on 3-T SWI in patients with moderate/severe TBI. METHODS: Standardized 3-T SWI and T1-weighted imaging were obtained 3 and 26 weeks after TBI in 31 patients. Their microbleeds were computer-aided detected and classified by a neuroradiologist as no, possible, or definite at baseline and follow-up, separately (single-scan evaluation). Thereafter, the classifications were re-evaluated after comparison between the time-points (post-comparison evaluation). We selected the possible microbleeds at baseline at single-scan evaluation and recorded their post-comparison classification at follow-up. RESULTS: Of the 1038 microbleeds at baseline, 173 were possible microbleeds. Of these, 53.8% corresponded to no microbleed at follow-up. At follow-up, 30.6% were possible and 15.6% were definite. Of the 120 differences between baseline and follow-up, 10% showed evidence of a pathophysiological change over time. Proximity to extra-axial injury and proximity to definite microbleeds were independently predictive of becoming a definite microbleed at follow-up. The reclassification level differed between anatomical locations. CONCLUSIONS: Our findings support disregarding possible microbleeds in the absence of clinical consequences. In selected cases, however, a follow-up SWI-scan could be considered to exclude evolution into a definite microbleed.


Subject(s)
Brain Injuries, Traumatic , Magnetic Resonance Imaging , Brain Injuries, Traumatic/complications , Brain Injuries, Traumatic/diagnostic imaging , Cerebral Hemorrhage/diagnostic imaging , Humans , Longitudinal Studies , Magnetic Resonance Imaging/methods , Radiography
2.
Ultrasound Med Biol ; 45(3): 773-785, 2019 03.
Article in English | MEDLINE | ID: mdl-30573305

ABSTRACT

Ultrasound imaging remains out of reach for most pregnant women in developing countries because it requires a trained sonographer to acquire and interpret the images. We address this problem by presenting a system that can automatically estimate the fetal head circumference (HC) from data obtained with use of the obstetric sweep protocol (OSP). The OSP consists of multiple pre-defined sweeps with the ultrasound transducer over the abdomen of the pregnant woman. The OSP can be taught within a day to any health care worker without prior knowledge of ultrasound. An experienced sonographer acquired both the standard plane-to obtain the reference HC-and the OSP from 183 pregnant women in St. Luke's Hospital, Wolisso, Ethiopia. The OSP data, which will most likely not contain the standard plane, was used to automatically estimate HC using two fully convolutional neural networks. First, a VGG-Net-inspired network was trained to automatically detect the frames that contained the fetal head. Second, a U-net-inspired network was trained to automatically measure the HC for all frames in which the first network detected a fetal head. The HC was estimated from these frame measurements, and the curve of Hadlock was used to determine gestational age (GA). The results indicated that most automatically estimated GAs fell within the P2.5-P97.5 interval of the Hadlock curve compared with the GAs obtained from the reference HC, so it is possible to automatically estimate GA from OSP data. Our method therefore has potential application for providing maternal care in resource-constrained countries.


Subject(s)
Deep Learning , Head/anatomy & histology , Head/embryology , Ultrasonography, Prenatal/methods , Adult , Developing Countries , Female , Humans , Pregnancy , Reproducibility of Results
3.
Ultrasound Med Biol ; 44(11): 2250-2260, 2018 11.
Article in English | MEDLINE | ID: mdl-30093339

ABSTRACT

We investigated how accurately low-cost ultrasound devices can estimate gestational age (GA) using both the standard plane and the obstetric sweep protocol (OSP). The OSP can be taught to health care workers without prior knowledge of ultrasound within one day and thus avoid the need to train dedicated sonographers. Three low-cost ultrasound devices were compared with one high-end ultrasound device. GA was estimated with the head circumference (HC), abdominal circumference (AC) and femur length (FL) using both the standard plane and the OSP. The results revealed that the HC, AC and FL can be used to estimate GA using low-cost ultrasound devices in the standard plane within the inter-observer variability presented in the literature. The OSP can be used to estimate GA by measuring the HC and the AC, but not the FL. This study shows that it is feasible to estimate GA in resource-limited countries with low-cost ultrasound devices using the OSP. This makes it possible to estimate GA and assess fetal growth for pregnant women in rural areas of resource-limited countries.


Subject(s)
Fetus/anatomy & histology , Gestational Age , Ultrasonography, Prenatal/economics , Ultrasonography, Prenatal/instrumentation , Adult , Developing Countries , Female , Humans , Observer Variation , Poverty , Pregnancy , Reproducibility of Results , Ultrasonography, Prenatal/methods
4.
PLoS One ; 13(8): e0200412, 2018.
Article in English | MEDLINE | ID: mdl-30138319

ABSTRACT

In this paper we present a computer aided detection (CAD) system for automated measurement of the fetal head circumference (HC) in 2D ultrasound images for all trimesters of the pregnancy. The HC can be used to estimate the gestational age and monitor growth of the fetus. Automated HC assessment could be valuable in developing countries, where there is a severe shortage of trained sonographers. The CAD system consists of two steps: First, Haar-like features were computed from the ultrasound images to train a random forest classifier to locate the fetal skull. Secondly, the HC was extracted using Hough transform, dynamic programming and an ellipse fit. The CAD system was trained on 999 images and validated on an independent test set of 335 images from all trimesters. The test set was manually annotated by an experienced sonographer and a medical researcher. The reference gestational age (GA) was estimated using the crown-rump length measurement (CRL). The mean difference between the reference GA and the GA estimated by the experienced sonographer was 0.8 ± 2.6, -0.0 ± 4.6 and 1.9 ± 11.0 days for the first, second and third trimester, respectively. The mean difference between the reference GA and the GA estimated by the medical researcher was 1.6 ± 2.7, 2.0 ± 4.8 and 3.9 ± 13.7 days. The mean difference between the reference GA and the GA estimated by the CAD system was 0.6 ± 4.3, 0.4 ± 4.7 and 2.5 ± 12.4 days. The results show that the CAD system performs comparable to an experienced sonographer. The presented system shows similar or superior results compared to systems published in literature. This is the first automated system for HC assessment evaluated on a large test set which contained data of all trimesters of the pregnancy.


Subject(s)
Fetal Development , Fetus/anatomy & histology , Head/anatomy & histology , Ultrasonography, Prenatal/methods , Automation , Female , Fetus/diagnostic imaging , Fetus/embryology , Gestational Age , Head/diagnostic imaging , Head/embryology , Humans , Pregnancy
5.
IEEE Trans Biomed Circuits Syst ; 11(4): 849-857, 2017 08.
Article in English | MEDLINE | ID: mdl-28715339

ABSTRACT

OBJECTIVE: In this paper, we present the design of low-cost medical ultrasound scanners aimed at the detection of maternal mortality risk factors in developing countries. METHOD: Modern ultrasound scanners typically employ a high element count transducer array with multichannel transmit and receive electronics. To minimize hardware costs, we employ a single piezoelectric element, mechanically swept across the target scene, and a highly cost-engineered single channel acquisition circuit. Given this constraint, we compare the achievable image quality of a monostatic fixed focus scanner (MFFS) with a monostatic synthetic aperture scanner (MSAS) using postfocusing. Quantitative analysis of image quality was carried out using simulation and phantom experiments, which were used to compare a proof-of-concept MSAS prototype with an MFFS device currently available on the market. Finally, in vivo experiments were performed to validate the MSAS prototype in obstetric imaging. RESULTS: Simulations show that the achievable lateral resolution of the MSAS approach is superior at all ranges compared to the fixed focus approach. Phantom experiments verify the improved resolution of the MSAS prototype but reveal a lower signal to noise ratio. In vivo experiments show promising results using the MSAS for clinical diagnostics in prenatal care. CONCLUSION: The proposed MSAS achieves superior resolution but lower SNR compared to an MFFS approach, principally due to lower acoustic energy emitted. SIGNIFICANCE: The production costs of the proposed MSAS could be an order of magnitude lower than any other ultrasound system on the market today, bringing affordable obstetric imaging a step closer for developing countries.


Subject(s)
Obstetrics/instrumentation , Ultrasonography/instrumentation , Equipment Design , Female , Humans , Maternal Mortality , Phantoms, Imaging , Pregnancy , Risk Factors , Signal-To-Noise Ratio , Transducers
SELECTION OF CITATIONS
SEARCH DETAIL
...