Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chem ; 96(22): 9294-9301, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38758734

ABSTRACT

Despite the high gain in peak capacity, online comprehensive two-dimensional liquid chromatography coupled with high-resolution mass spectrometry (LC × LC-HRMS) has not yet been widely applied to the analysis of complex protein digests. One reason is the method's reduced sensitivity which can be linked to the high flow rates of the second separation dimension (2D). This results in higher dilution factors and the need for flow splitters to couple to ESI-MS. This study reports proof-of-principle results of the development of an RPLC × RPLC-HRMS method using parallel gradients (2D flow rate of 0.7 mL min-1) and its comparison to shifted gradient methods (2D of 1.4 mL min-1) for the analysis of complex digests using HRMS (QExactive-Plus MS). Shifted and parallel gradients resulted in high surface coverage (SC) and effective peak capacity (SC of 0.6226 and 0.7439 and effective peak capacity of 779 and 757 in 60 min). When applied to a cell line digest sample, parallel gradients allowed higher sensitivity (e.g., average MS intensity increased by a factor of 3), allowing for a higher number of identifications (e.g., about 2600 vs 3900 peptides). In addition, reducing the modulation time to 10 s significantly increased the number of MS/MS events that could be performed. When compared to a 1D-RPLC method, parallel RPLC × RPLC-HRMS methods offered a higher separation performance (FHWH from 0.12 to 0.018 min) with limited sensitivity losses resulting in an increase of analyte identifications (e.g., about 6000 vs 7000 peptides and 1500 vs 1990 proteins).


Subject(s)
Mass Spectrometry , Proteins , Chromatography, Liquid/methods , Proteins/analysis , Proteins/metabolism , Humans , Mass Spectrometry/methods
2.
Chem Commun (Camb) ; 60(1): 36-50, 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38053451

ABSTRACT

While the advent of modern analytical technology has allowed scientists to determine the complexity of mixtures, it also spurred the demand to understand these sophisticated mixtures better. Chemical transformation can be used to provide insights into properties of complex samples such as degradation pathways or molecular heterogeneity that are otherwise unaccessible. In this article, we explore how sample transformation is exploited across different application fields to empower analytical methods. Transformation mechanisms include molecular-weight reduction, controlled degradation, and derivatization. Both offline and online transformation methods have been explored. The covered studies show that sample transformation facilitates faster reactions (e.g. several hours to minutes), reduces sample complexity, unlocks new sample dimensions (e.g. functional groups), provides correlations between multiple sample dimensions, and improves detectability. The article highlights the state-of-the-art and future prospects, focusing in particular on the characterization of protein and nucleic-acid therapeutics, nanoparticles, synthetic polymers, and small molecules.

3.
J Chromatogr A ; 1672: 463072, 2022 Jun 07.
Article in English | MEDLINE | ID: mdl-35462308

ABSTRACT

Smokeless powders (SPs) are one of the most commonly used propellants for ammunition but can also be abused as energetic material in improvised explosive devices (IEDs) such as pipe bombs. After a shooting or explosion, unburnt or partially burnt particulates may be observed which can be used for forensic investigation. SPs comprise mainly nitrocellulose (NC) and additives. Therefore, the characterization of both NC and the additives is of significant forensic importance. Typically, the identification, classification, and chemical profiling of smokeless powders are based exclusively on the analysis of the additives. In this study, information regarding the NC base component was combined with the chemical analysis of the additives using two-dimensional liquid chromatography (2D-LC). The system combines size-exclusion chromatography (SEC) and reversed-phase liquid chromatography (RPLC) in an on-line heart-cut 2D-LC configuration. In the first dimension, the NC is characterized by its molecular-weight distribution (MWD) while being separated from the additives. The additives are then transferred to the second-dimension separation using a novel analyte-transfer system. In the second dimension, the additives are separated to obtain a detailed profile of the low-molecular-mass compounds in the SP. With this approach, the MWD of the NC and the composition of the additives in SP have been obtained within an hour. A discrimination power of 90.53% was obtained when studying exclusively the NC MWD, and 99.47% for the additive profile. This novel combination enables detailed forensic comparison of intact SPs. Additionally, no extensive sample preparation is required, making the developed method less labor intensive.


Subject(s)
Chromatography, Reverse-Phase , Lobeline , Chromatography, Gel , Chromatography, Reverse-Phase/methods , Powders
4.
Anal Chim Acta ; 1053: 62-69, 2019 Apr 11.
Article in English | MEDLINE | ID: mdl-30712570

ABSTRACT

Biodegradable polymeric materials may eventually replace biostable materials for medical applications, including therapeutic devices, scaffolds for tissue engineering, and drug-delivery vehicles. To further develop such materials, a more fundamental understanding is necessary to correlate parameters including chemical-composition distribution within a macromolecular structure with the final properties of the material, including particle-size. A wide variety of analytical techniques have been applied for the characterization of polymer materials, including hyphenated techniques such as comprehensive two-dimensional liquid chromatography (LC × LC). In this context, we have investigated enzymatic degradation of polyester-based nanoparticles, both in-solution and by the use of an immobilized-enzyme reactor (IMER). We have demonstrated for the first time the implementation of such an IMER in a size-exclusion chromatography system for on-line degradation and subsequent analysis of the polymer degradation products. The effect of residence times ranging from 12 s to 4 min on polymer degradation was assessed. IMER-assisted degradation is much faster compared to in-solution degradation, which requires several hours to days, and opens the possibility to use such reactors in LC × LC modulation interfaces.


Subject(s)
Enzymes, Immobilized/chemistry , Enzymes, Immobilized/metabolism , Lab-On-A-Chip Devices , Polymers/chemistry , Polymers/chemical synthesis
SELECTION OF CITATIONS
SEARCH DETAIL
...