1.
Analyst ; 146(4): 1402-1413, 2021 Feb 21.
Article in English | MEDLINE | ID: mdl-33404022

ABSTRACT

Biomethane is a renewable energy gas with great potential to contribute to the diversification and greening of the natural gas supply. Ideally, biomethane can directly be injected into the natural gas grid system. For grid injection, specifications such as those in EN 16723-1 shall be met. One of the impurities to be monitored is hydrogen chloride (HCl). To assess conformity with the specification for HCl, accurate and reliable test methods are required. Here, we report the development of three novel test methods, based on a variety of laser absorption spectroscopy techniques (Direct absorption spectroscopy-DAS and wavelength modulation spectroscopy-WMS) and ion-exchange chromatography, for the measurement of HCl in biomethane. Gas mixtures of HCl in biomethane were used to demonstrate the performance of the spectroscopic systems in the nmol mol-1 to low µmol mol-1 ranges, achieving uncertainties in the 4% range, k = 2. For ion-exchange chromatography analysis, HCl was first collected on an alkali-impregnated quartz fiber filter. The analysis was performed according to ISO 21438-2 and validated using synthetic biomethane spiked with HCl. The relative expanded uncertainties for the ion exchange chromatography HCl measurements are in the 10-37% range, k = 2. The results presented for the 3 test methods demonstrate that the respective methods can be used for HCl conformity assessment in biomethane.

2.
Anal Chim Acta ; 902: 22-32, 2016 Jan 01.
Article in English | MEDLINE | ID: mdl-26703250

ABSTRACT

The traceable and accurate measurement of biogas impurities is essential in order to robustly assess compliance with the specifications for biomethane being developed by CEN/TC408. An essential part of any procedure aiming to determinate the content of impurities is the sampling and the transfer of the sample to the laboratory. Key issues are the suitability of the sample container and minimising the losses of impurities during the sampling and analysis process. In this paper, we review the state-of-the-art in biogas sampling with the focus on trace impurities. Most of the vessel suitability studies reviewed focused on raw biogas. Many parameters need to be studied when assessing the suitability of vessels for sampling and storage, among them, permeation through the walls, leaks through the valves or physical leaks, sorption losses and adsorption effects to the vessel walls, chemical reactions and the expected initial concentration level. The majority of these studies looked at siloxanes, for which sampling bags, canisters, impingers and sorbents have been reported to be fit-for-purpose in most cases, albeit with some limitations. We conclude that the optimum method requires a combination of different vessels to cover the wide range of impurities commonly found in biogas, which have a wide range of boiling points, polarities, water solubilities, and reactivities. The effects from all the parts of the sampling line must be considered and precautions must be undertaken to minimize these effects. More practical suitability tests, preferably using traceable reference gas mixtures, are needed to understand the influence of the containers and the sampling line on sample properties and to reduce the uncertainty of the measurement.


Subject(s)
Gases , Methane/analysis , Trace Elements/analysis
3.
Anal Chem ; 86(13): 6695-702, 2014 Jul 01.
Article in English | MEDLINE | ID: mdl-24882216

ABSTRACT

The first reference gas mixtures of sulfur-free natural gas odorants that are traceable to the International System of Units (SI) have been produced and their compositions validated. These mixtures, which contain methyl acrylate and ethyl acrylate at amount fractions between 1.1 and 2.1 µmol mol(-1), can be used to underpin measurements of sulfur-free odorants, which are increasingly being used to odorize natural gas in transmission networks as they have less harmful properties than traditional sulfur-containing odorants. The reference gas mixtures produced have been shown to be stable in passivated aluminum cylinders for at least 8 months and have been validated (to within 6% or less) by interlaboratory measurements at three National Measurement Institutes. The stability of methyl acrylate and ethyl acrylate in gas sampling bags has been investigated, and the challenges of analyzing 2-ethyl-3-methylpyrazine, which is used as a stabilizer in sulfur-free odorants, are also briefly discussed.