Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Eur J Obstet Gynecol Reprod Biol ; 291: 123-127, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37866275

ABSTRACT

OBJECTIVE(S): Accidental rupture of membranes (acROM), an insertion-related complication of the balloon catheter for labor induction, may prolong the duration of ruptured membranes. Prolonged rupture of membranes is associated with an increased risk of intra-uterine infection with possibly neonatal infection as result. Little is known about safety profiles of different catheters regarding the occurrence of these complications. This study compares the incidence of neonatal early-onset sepsis (EOS) and acROM in women receiving either silicone or latex balloon catheters. STUDY DESIGN: A retrospective cohort study was performed including 2200 women (silicone balloon catheter, n = 1100 vs. latex balloon catheter, n = 1100). The primary outcomes were the incidence of acROM, and suspected and proven neonatal EOS. Secondary outcomes were: prolonged rupture of membranes, intrapartum fever, pre- or postnatal neonatal exposure to antibiotics, and perinatal outcomes. A subgroup analysis was performed between women with and without acROM. RESULTS: No statistically significant difference with regard to suspected or proven EOS was seen between the silicone and latex groups. The acROM rate was significantly higher in the silicone group compared to the latex group (2.9 % and 0.3 %, p < 0.01). Prolonged rupture of membranes was significantly more common in the silicone group compared to the latex group (5.0 % and 2.4 %, p < 0.01), as was the use of intrapartum antibiotics (12.7 % and 9.6 %, p = 0.02). Neonates were significantly more often exposed to pre- or postnatal antibiotics in the silicone group compared to the latex group (17.6 % and 13.6 %, p = 0.01). Subgroup analysis showed significantly more suspected and proven neonatal EOS when catheter-insertion was complicated with acROM (11.4 % and 20.0 %), compared to cases without acROM (3.8 % and 2.5 %), irrespective of the type of catheter used. CONCLUSION(S): The use of silicone balloon catheters for labor induction results in higher rates of acROM, prolonged rupture of membranes and use of intrapartum antibiotics, compared to latex balloon catheters. No statistically significant differences were found in the occurrence of suspected or proven neonatal EOS, however neonates from the silicone group were more often exposed to pre- or postnatal antibiotics. When acROM occurs, irrespective of type of catheter used, suspected and proven neonatal EOS was seen more often.


Subject(s)
Fetal Membranes, Premature Rupture , Neonatal Sepsis , Infant, Newborn , Pregnancy , Female , Humans , Latex/adverse effects , Retrospective Studies , Silicones/adverse effects , Labor, Induced/methods , Urinary Catheters , Catheters/adverse effects , Fetal Membranes, Premature Rupture/epidemiology , Fetal Membranes, Premature Rupture/etiology , Anti-Bacterial Agents/therapeutic use , Cervical Ripening
2.
Ultrasound Obstet Gynecol ; 61(2): 275-277, 2023 02.
Article in English | MEDLINE | ID: mdl-36722426
3.
Article in English | MEDLINE | ID: mdl-35131629

ABSTRACT

OBJECTIVE: Current guidelines provide little supporting literature for the definition of uterine tachysystole during labour and no distinction is made for optimal contraction frequency depending on the clinical situation. We hypothesize that fetal hypoxia is frequently caused by uterine tachysystole and that high uterine contraction frequencies are especially harmful when fetal heart rate (FHR) abnormalities are present. We studied the association between contraction frequency and fetal scalp pH values in women with an indication for fetal blood sampling (FBS) based on FHR abnormalities. STUDY DESIGN: A retrospective study including 762 women was performed in a tertiary teaching hospital in the Netherlands from January 2015 until January 2020. Women with a singleton pregnancy with a gestational age ≥ 34+0 weeks were included when FBS was performed because of suspicious or pathological FHR tracings. Exclusion criteria were maternal age < 18 years, failed fetal scalp pH values, lack of thirty minute registration by tocodynamometry prior to FBS, poor quality of uterine monitoring, intrauterine resuscitation in the thirty minutes prior to FBS, maternal body mass index ≥ 30 kg/m2 and neonatal birth weight < 10th percentile. Uterine contractions in the thirty minutes prior to FBS were manually annotated by a researcher who was blinded to FBS values, FHR and other obstetrical data. Linear and logistic analysis were used to explore the association between uterine contraction frequency and FBS results. RESULTS: Low fetal scalp pH values were significantly associated with contraction frequency prior to FBS. Fetuses of women with four to five contractions per ten minutes prior to FBS were 2.4 times more likely to have hypoxia as compared to fetuses of women with two to three contractions per ten minutes (aOR 2.4, 95% CI 1.1-5.4). With increasing contraction frequency, the risk of fetal hypoxia further increased. CONCLUSIONS: Contraction frequency above four per ten minutes prior to FBS is significantly associated with fetal hypoxia in women with FHR abnormalities. We suggest to aim for a maximum contraction frequency of four per ten minutes in these women.


Subject(s)
Heart Rate, Fetal , Uterine Contraction , Adolescent , Female , Fetus , Heart Rate, Fetal/physiology , Humans , Hydrogen-Ion Concentration , Infant , Infant, Newborn , Pregnancy , Retrospective Studies , Scalp
4.
Ultrasound Obstet Gynecol ; 59(5): 651-659, 2022 05.
Article in English | MEDLINE | ID: mdl-34558747

ABSTRACT

OBJECTIVES: Two-dimensional speckle-tracking echocardiography (2D-STE) is a promising technique which allows assessment of fetal cardiac function, and can be used in the evaluation of cardiac and non-cardiac diseases in pregnancy. However, reliable fetal reference values for deformation parameters measured using 2D-STE are needed before it can be introduced into clinical practice. This study aimed to obtain reference values for fetal global longitudinal strain (GLS) and GLS rate (GLSR) measured using 2D-STE and compare right and left ventricular values. METHODS: This was a prospective longitudinal cohort study of uncomplicated pregnancies that underwent echocardiography every 4 weeks from inclusion at 18-21 weeks until delivery to obtain four-chamber loops of the fetal heart. Left and right ventricular GLS and GLSR were measured using 2D-STE at each examination. Using Bayesian mixed-effects models, reference values with lower and upper 5% prediction limits were calculated according to gestational age. Right and left ventricular GLS values according to gestational age were compared using the Wilcoxon signed-rank test. RESULTS: A total of 592 left ventricular and 566 right ventricular GLS and GLSR measurements were obtained from 124 women with uncomplicated pregnancy and non-anomalous, appropriately grown fetuses. Reference values were obtained for both fetal ventricles according to gestational week. GLS and GLSR values of both ventricles increased (i.e. became less negative) significantly during pregnancy. Right ventricular GLS values were significantly higher (i.e. less negative) than the respective left ventricular values at every gestational week. CONCLUSIONS: Reference values were obtained for fetal GLS and GLSR measured using 2D-STE. GLS and GLSR values increased significantly for both ventricles from the second trimester until delivery. GLS values were significantly higher for the right ventricle compared with the left ventricle. Future studies are needed to assess whether the obtained reference values are helpful in clinical practice in the assessment of pregnancy complications, such as fetal growth restriction or cardiac anomaly. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Subject(s)
Echocardiography , Ultrasonography, Prenatal , Bayes Theorem , Echocardiography/methods , Female , Fetal Heart/diagnostic imaging , Heart Ventricles/diagnostic imaging , Humans , Longitudinal Studies , Male , Pregnancy , Prospective Studies , Reproducibility of Results , Ventricular Function, Left
5.
BMC Pregnancy Childbirth ; 21(1): 791, 2021 Nov 25.
Article in English | MEDLINE | ID: mdl-34823483

ABSTRACT

BACKGROUND: Worldwide, hypertensive disorders of pregnancy (HDP), fetal growth restriction (FGR) and preterm birth remain the leading causes of maternal and fetal pregnancy-related mortality and (long-term) morbidity. Fetal cardiac deformation changes can be the first sign of placental dysfunction, which is associated with HDP, FGR and preterm birth. In addition, preterm birth is likely associated with changes in electrical activity across the uterine muscle. Therefore, fetal cardiac function and uterine activity can be used for the early detection of these complications in pregnancy. Fetal cardiac function and uterine activity can be assessed by two-dimensional speckle-tracking echocardiography (2D-STE), non-invasive fetal electrocardiography (NI-fECG), and electrohysterography (EHG). This study aims to generate reference values for 2D-STE, NI-fECG and EHG parameters during the second trimester of pregnancy and to investigate the diagnostic potential of these parameters in the early detection of HDP, FGR and preterm birth. METHODS: In this longitudinal prospective cohort study, eligible women will be recruited from a tertiary care hospital and a primary midwifery practice. In total, 594 initially healthy pregnant women with an uncomplicated singleton pregnancy will be included. Recordings of NI-fECG and EHG will be made weekly from 22 until 28 weeks of gestation and 2D-STE measurements will be performed 4-weekly at 16, 20, 24 and 28 weeks gestational age. Retrospectively, pregnancies complicated with pregnancy-related diseases will be excluded from the cohort. Reference values for 2D-STE, NI-fECG and EHG parameters will be assessed in uncomplicated pregnancies. After, 2D-STE, NI-fCG and EHG parameters measured during gestation in complicated pregnancies will be compared with these reference values. DISCUSSION: This will be the a large prospective study investigating new technologies that could potentially have a high impact on antepartum fetal monitoring. TRIAL REGISTRATION: Registered on 26 March 2020 in the Dutch Trial Register (NL8769) via https://www.trialregister.nl/trials and registered on 21 October 2020 to the Central Committee on Research Involving Human Subjects (NL73607.015.20) via https://www.toetsingonline.nl/to/ccmo_search.nsf/Searchform?OpenForm .


Subject(s)
Echocardiography/methods , Electrocardiography/methods , Prenatal Diagnosis/methods , Adult , Female , Fetal Growth Retardation/diagnosis , Heart Rate, Fetal/physiology , Humans , Hypertension, Pregnancy-Induced/diagnosis , Longitudinal Studies , Netherlands , Pregnancy , Pregnancy Trimester, Second , Premature Birth/diagnosis , Prospective Studies , Uterine Monitoring , Uterus/physiology
6.
Int J Lab Hematol ; 40(1): 72-76, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28868811

ABSTRACT

INTRODUCTION: Total vitamin B12 levels decrease significantly during pregnancy and recover to normal values within 8-week postpartum. Holotranscobalamin (holoTC) reflects the active part of vitamin B12 and has been shown to remain constant during pregnancy and postpartum. A mechanism of redistribution of vitamin B12 is suggested, with a shift toward holoTC if there is insufficient total vitamin B12 available. Our objective was to examine vitamin B12 deficiency and the active vitamin B12 fraction in postpartum women. METHODS: Total vitamin B12 and holoTC were measured in 171 women within 48 hours (T0) and at 5 weeks (T5) postpartum. Vitamin B12 deficiency was defined as total vitamin B12 < 180 pmol/L or holoTC <32 pmol/L. The active vitamin B12 fraction was defined as holoTC/total vitamin B12. RESULTS: Without intervention, vitamin B12 deficiency based on both serum total vitamin B12 and holoTC changed from 75% and 60%, to respectively 10% and 6% at T5. The fraction of active vitamin B12 was significant higher in vitamin B12 deficient women at both time points and across time (P < .0001 and P = .002). A high fraction of active vitamin B12 was only present in women with total vitamin B12 deficiency at T0. At T5, no high vitamin B12 fraction was found. CONCLUSION: The changes in total vitamin B12 levels seem to be based on a physiological changes rather than vitamin B12 deficiency. The results of this study confirm the hypothesis that a shift toward the metabolic active vitamin B12 (holoTC) occurs in women with insufficient available total vitamin B12.


Subject(s)
Postpartum Period/blood , Vitamin B 12/blood , Adult , Female , Humans , Pregnancy , Time Factors , Vitamin B 12 Deficiency/blood
7.
Int J Lab Hematol ; 34(5): 510-6, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22548729

ABSTRACT

INTRODUCTION: To evaluate the use of reticulocyte hemoglobin content (CHr) and mean corpuscular volume (MCV) to identify truly iron-deficient women with postpartum anemia (PPA), in order to reduce unnecessary iron supplementation. METHODS: Three hundred women with more than 500 mL of blood loss or clinical signs of anemia were divided in a control (Hb ≥ 10.5 g/dL, N = 150) and postpartum anemia group (PPA, Hb < 10.5 g/dL; N = 150). PPA women were given ferrous fumarate for a period of 4 weeks. Efficacy of the treatment was evaluated by comparing Hb, CHr, and MCV at baseline (T(0)) and after 4 weeks (T(4)). Using standard iron deficiency cut off values for MCV (80 fL) and CHr (28 pg) at T(0), we divided the PPA group of both parameters into two subgroups, one suggestive for iron deficiency and one suggestive for noniron deficiency. RESULTS: Irrespective of the parameter or the subdivision, delta Hb concentrations (T(4) -T(0)) showed a similar increase in all PPA subgroups investigated. Both parameters in the PPA subgroups below their respective cut off value showed a significant improvement toward normalization, while the MCV and CHr in the PPA subgroups above their respective cut off value did not show any significant increase. CONCLUSION: Our data suggest that the etiology of the anemia in postpartum anemic women is not always iron deficiency. Using a combination of Hb, MCV and CHr, we increased the stringency to identify truly iron-deficient postpartum anemic women, thereby reducing unnecessary iron supplementation in those women with sufficient iron stores.


Subject(s)
Anemia, Iron-Deficiency/blood , Anemia/blood , Erythrocyte Indices , Hemoglobins/metabolism , Reticulocytes/metabolism , Adult , Anemia/complications , Anemia/drug therapy , Anemia, Iron-Deficiency/diagnosis , Anemia, Iron-Deficiency/etiology , Female , Ferrous Compounds/therapeutic use , Humans , Postpartum Period , Predictive Value of Tests , Reticulocytes/cytology , Time Factors , Trace Elements/therapeutic use , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...