Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38670866

ABSTRACT

BACKGROUND: Aortic valve lithotripsy can fragment aortic valve calcium deposits and potentially restore leaflet pliability in animal model and ex-vivo, but clinical data is limited. Transcatheter aortic valve implantation (TAVR) might not be feasible as an urgent procedure in critically ill patients. Balloon valvuloplasty has the major limitation of valve recoil and inducing aortic regurgitation. AIMS: To determine the clinical feasibility of aortic valve lithotripsy-facilitated balloon valvuloplasty in patients with severe aortic stenosis unsuitable for valvular replacement. METHODS: We performed lithotripsy as adjunctive therapy to balloon aortic valvuloplasty in ten consecutive patients, most of whom were deemed unfit for TAVR. Lithotripsy of the aortic valve was performed with simultaneous inflation of one to three peripheral lithotripsy balloons to deliver ultrasound pulses. Rapid pacing was not used during lithotripsy. Aortic valve velocity, gradient, and valve area were measured before and after the procedure by echocardiogram. Transvalvular pressure gradient was recorded intra-procedurally. Periprocedural and ninety-day clinical outcomes were followed. RESULTS: Procedure was technically successful in 9 out of 10 patients and aborted in one patient due to cardiogenic shock. One patient had femoral closure device related complication. There was a statistically significant decrease in valvular gradient and increase in aortic valve area. 9 out of 10 patients recovered from acute episode and were discharged. 6 patients had improvement in NYHA class. 4 patients were subsequently able to receive TAVR. 90-day mortality occurred in 3 patients. There was no stroke or bradyarrhythmia peri-procedurally and no heart failure hospitalization at 90 days. CONCLUSION: Aortic valve lithotripsy-facilitated balloon valvuloplasty has reasonable feasibility, safety and technical reproducibility and acute clinical result. Hemodynamic effect is similar to that of balloon valvuloplasty reported in the literature. Subsequent Prognosis is not altered in critically ill patients.

2.
Cardiovasc Revasc Med ; 62: 105-118, 2024 May.
Article in English | MEDLINE | ID: mdl-38212236

ABSTRACT

BACKGROUND: Percutaneous closure of aortic and ventricular pseudoaneurysms (PSA) has only been reported on a case report and series basis. In previous case reports, percutaneous closure has been performed successfully in patients of prohibitive surgical risk. This case series aims to show feasibility of percutaneous closure of aortic and ventricular pseudoaneurysm secondary to perivalvular leak (PVL) in a small patient population and the utility of multimodality imaging as an integral tool in procedural planning. This is the largest complex case series to date describing the feasibility and success rate of complex PSA closure, with a follow-up period of up to 4 years. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all paravalvular leak cases with associated pseudoaneurysm formation for which a closure procedure was performed. Ten patients were identified. Pooled analysis for cases from institutional review (n = 10) and systemic literature review (n = 39) was performed. The success rate was 100 %. At 30-days, the mortality was 0 %. CONCLUSION: In paravalvular leak patients with subsequent pseudoaneurysm formation, exhaustive imaging evaluation is required for closure. However, it can be achievable with favorable rates of success.


Subject(s)
Aneurysm, False , Heart Valve Prosthesis Implantation , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/etiology , Aneurysm, False/therapy , Male , Female , Treatment Outcome , Aged , Middle Aged , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Aneurysm/diagnostic imaging , Heart Aneurysm/etiology , Heart Aneurysm/therapy , Cardiac Catheterization/adverse effects , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Time Factors , Aged, 80 and over , Heart Valve Prosthesis , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Echocardiography, Transesophageal , Adult
3.
Echocardiography ; 40(11): 1285-1291, 2023 11.
Article in English | MEDLINE | ID: mdl-37842844

ABSTRACT

Left ventricular pseudoaneurysm (PSA) after surgical aortic valve replacement (AVR) is a known but uncommon complication. It is associated with risks such as thromboembolism and life-threatening rupture. Surgical repair has traditionally been utilized in low-risk patients but transcatheter closure has become a promising therapeutic option. This case report describes the utility of multimodality imaging in pre-, intra-, and post-procedural evaluation of transcatheter PSA closure and is among the first to demonstrate the utility of 3D print model.


Subject(s)
Aneurysm, False , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aneurysm, False/diagnostic imaging , Aneurysm, False/surgery , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation/adverse effects , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/methods , Multimodal Imaging , Treatment Outcome
4.
Cardiovasc Revasc Med ; 53S: S253-S261, 2023 08.
Article in English | MEDLINE | ID: mdl-36089455

ABSTRACT

Management of large right heart thrombi and vegetations is challenging. Medical management may be insufficient to prevent embolization or treat infection. Surgery carries a high mortality and is often not an option for these patients with multiple comorbidities. We present a case series of four patients describing percutaneous aspiration thrombectomy with AngioVac device as a safe and effective treatment for high-risk patients with right heart thrombi or tricuspid valvular vegetations. Indexing words.


Subject(s)
Heart Valve Diseases , Thrombosis , Humans , Thrombosis/etiology , Thrombectomy , Treatment Outcome , Equipment Design
SELECTION OF CITATIONS
SEARCH DETAIL
...