Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 181
Filter
1.
Eur Radiol ; 28(6): 2700-2707, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29372312

ABSTRACT

OBJECTIVES: To assess the additional diagnostic value of 18F-fluorocholine PET imaging in preoperative localization of pathologic parathyroid glands in clinically manifest hyperparathyroidism in case of negative or conflicting ultrasound and scintigraphy results. METHODS: A retrospective, single-institution study of 26 patients diagnosed with hyperparathyroidism. In cases where ultrasound and scintigraphy failed to detect the location of an adenoma in order to allow a focused surgical approach, an additional 18F-fluorocholine PET scan was performed and its results were compared with the intraoperative findings. RESULTS: A total of 26 patients underwent 18F-fluorocholine PET/CT (n = 11) or PET/MRI (n = 15). Adenomas were detected in 25 patients (96.2%). All patients underwent surgery, and the location predicted by PET hybrid imaging was confirmed intraoperatively by frozen section and adequate parathyroid hormone drop after removal. None of the patients needed revision surgery during follow-up. CONCLUSIONS: These results demonstrate that 18F-fluorocholine PET imaging is a highly accurate method to detect parathyroid adenomas even in case of previous localization failure by other imaging examinations. KEY POINTS: • With 18 F-fluorocholine PET imaging, parathyroid adenomas could be detected in 96.2%. • 18 F-fluorocholine imaging is a highly accurate method to detect parathyroid adenomas. • We encourage its use, where ultrasound fails to detect an adenoma.


Subject(s)
Adenoma/diagnostic imaging , Choline/analogs & derivatives , Hyperparathyroidism, Primary/diagnostic imaging , Parathyroid Neoplasms/diagnostic imaging , Radiopharmaceuticals , Adenoma/surgery , Aged , Aged, 80 and over , Female , Fluorine Radioisotopes , Humans , Intraoperative Care , Male , Middle Aged , Parathyroid Glands/diagnostic imaging , Parathyroid Neoplasms/surgery , Physical Examination , Positron Emission Tomography Computed Tomography/methods , Radionuclide Imaging , Reoperation , Retrospective Studies , Ultrasonography
2.
Insights Imaging ; 4(4): 481-90, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23673453

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate if positron emission tomography (PET)/magnetic resonance imaging (MRI) with just one gradient echo sequence using the body coil is diagnostically sufficient compared with a standard, low-dose non-contrast-enhanced PET/computed tomography (CT) concerning overall diagnostic accuracy, lesion detectability, size and conspicuity evaluation. METHODS AND MATERIALS: Sixty-three patients (mean age 58 years, range 19-86 years; 23 women, 40 men) referred for either staging or restaging/follow-up of various malignant tumours (malignant melanoma, lung cancer, breast cancer, Hodgkin's lymphoma, non-Hodgkin's lymphoma, CUP, gynaecology tumours, pleural mesothelioma, oesophageal cancer, colorectal cancer, stomach cancer) were prospectively included. Imaging was conducted using a tri-modality PET/CT-MR set-up (full ring, time-of-flight Discovery PET/CT 690, 3 T Discovery MR 750, both GE Healthcare, Waukesha, WI). All patients were positioned on a dedicated PET/CT- and MR-compatible examination table, allowing for patient transport from the MR system to the PET/CT without patient movement. In accordance with RECIST 1.1 criteria, measurements of the maximum lesion diameters on CT and MR images were obtained. In lymph nodes, the short axis was measured. A four-point scale was used for assessment of lesion conspicuity: 1 (>25 % of lesion borders definable), 2 (25-50 %), 3 (50-75 %) and 4 (>75 %). For each lesion the corresponding anatomical structure was noted based on anatomical information of the spatially co-registered PET/CT and PET/MRI image sections. Additionally, lesions were divided into three categories: "tumour mass", "lymph nodes" and "lesions". Differences in overall lesion detectability and conspicuity in PET/CT and PET/MRI, as well as differences in detectability based on the localisation and lesion type, were analysed by Wilcoxon signed rank test. RESULTS: A total of 126 PET-positive lesions were evaluated. Overall, no statistically significant superiority of PET/CT over PET/MRI or vice versa in terms of lesion conspicuity was found (p = 0.095; mean score CT 2.93, mean score MRI 2.75). A statistically significant superiority concerning conspicuity of PET/CT over PET/MRI was found in pulmonary lesions (p = 0.016). Additionally, a statistically significant superiority of PET/CT over PET/MRI in "lymph nodes" regarding lesion conspicuity was also found (p = 0.033). A higher mean score concerning bone lesions were found for PET/CT compared with PET/MRI; however, these differences did not achieve statistical significance. CONCLUSION: Overall, PET/MRI with body coil acquisition does not match entirely the diagnostic accuracy of standard low-dose PET/CT. Thus, it might only serve as a back-up solution in very few patients. Overall, more time needs to be invested on the MR imaging part (higher matrix, more breath-holds, additional surface coil acquired sequences) to match up with the standard low-dose PET/CT. MAIN MESSAGES: • Evaluation of whether PET/MRI with one sequence using body coil is diagnostically sufficient compared with PET/CT • PET/MRI with body coil does not match entirely the diagnostic accuracy of standard low-dose PET/CT • PET/MRI might only serve as a backup solution in patients.

3.
Eur J Nucl Med Mol Imaging ; 40(1): 44-51, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22955547

ABSTRACT

PURPOSE: PET/MR has the potential to become a powerful tool in clinical oncological imaging. The purpose of this prospective study was to evaluate the performance of a single T1-weighted (T1w) fat-suppressed unenhanced MR pulse sequence of the abdomen in comparison with unenhanced low-dose CT images to characterize PET-positive lesions. METHODS: A total of 100 oncological patients underwent sequential whole-body (18)F-FDG PET with CT-based attenuation correction (AC), 40 mAs low-dose CT and two-point Dixon-based T1w 3D MRI of the abdomen in a trimodality PET/CT-MR system. PET-positive lesions were assessed by CT and MRI with regard to their anatomical location, conspicuity and additional relevant information for characterization. RESULTS: From among 66 patients with at least one PET-positive lesion, 147 lesions were evaluated. No significant difference between MRI and CT was found regarding anatomical lesion localization. The MR pulse sequence used performed significantly better than CT regarding conspicuity of liver lesions (p < 0.001, Wilcoxon signed ranks test), whereas no difference was noted for extrahepatic lesions. For overall lesion characterization, MRI was considered superior to CT in 40 % of lesions, equal to CT in 49 %, and inferior to CT in 11 %. CONCLUSION: Fast Dixon-based T1w MRI outperformed low-dose CT in terms of conspicuity and characterization of PET-positive liver lesions and performed similarly in extrahepatic tumour manifestations. Hence, under the assumption that the technical issue of MR AC for whole-body PET examinations is solved, in abdominal PET/MR imaging the replacement of low-dose CT by a single Dixon-based MR pulse sequence for anatomical lesion correlation appears to be valid and robust.


Subject(s)
Abdomen/diagnostic imaging , Magnetic Resonance Imaging , Multimodal Imaging , Positron-Emission Tomography , Tomography, X-Ray Computed , Adult , Aged , Female , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Neoplasms/diagnostic imaging , Neoplasms/pathology , Radiopharmaceuticals , Whole Body Imaging
4.
Eur Spine J ; 20(4): 640-8, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21127919

ABSTRACT

The purpose of this study is to assess the successful incorporation of cages in patients after cervical or lumbar intercorporal fusion with positron-emission tomography/computed tomography (PET/CT). Twenty patients (14 female and 6 male; mean age 58 years, age range 38-73 years) with 30 cervical (n = 13) or lumbar (n = 17) intercorporal fusions were prospectively enrolled in this study. Time interval between last intercorporal intervention and PET/CT ranged from 2 to 116 months (mean 63; median 77 months). IRB approval was obtained for all patients, and written informed consent was obtained from all patients. About 30 min prior to PET/CT scanning, 97-217 MBq (mean 161 MBq) 18F-fluoride were administered intravenously. Patients were imaged in supine position on a combined PET/CT system (Discovery RX/STE, 16/64 slice CT, GE Healthcare). 3D-PET emission data were acquired for 1.5 and 2 min/bed position, respectively, and reconstructed by a fully 3D iterative algorithm (VUE Point HD) using low-dose CT data for attenuation correction. A dedicated diagnostic thin-slice CT was optionally acquired covering the fused region. Areas of increased 18F-fluoride uptake around cages were determined by one double-board certified radiologist/nuclear physician and one board certified radiologist in consensus. In 12/20 (60%) patients, increased 18F-fluoride uptake around cages was observed. Of the 30 intercorporal fusions, 15 (50%) showed increased 18F-fluoride uptake. Median time between intervention and PET/CT examination in cages with increased uptake was 37 months (2-116 months), median time between intervention and PET/CT examination in those cages without increased uptake was 91 months (19-112 months), p (Wilcoxon) = 0.01 (one-sided). 14/29 (48%) cages with a time interval > 1 year between intervention and PET/CT scan showed an increased uptake. In conclusion, PET/CT frequently shows increased 18F-fluoride uptake in cervical and lumbar cages older than 1 year (up to almost 8 years in cervical cages and 10 years in lumbar cages) possibly indicating unsuccessful fusion due to increased stress/microinstability.


Subject(s)
Cervical Vertebrae/diagnostic imaging , Lumbar Vertebrae/diagnostic imaging , Positron-Emission Tomography/methods , Spinal Fusion/instrumentation , Tomography, X-Ray Computed/methods , Adult , Aged , Cervical Vertebrae/surgery , Female , Fluorine Radioisotopes , Follow-Up Studies , Humans , Longitudinal Studies , Lumbar Vertebrae/surgery , Male , Middle Aged , Retrospective Studies , Spinal Diseases/surgery , Spinal Fusion/methods , Time Factors , Treatment Outcome
5.
Nuklearmedizin ; 49(3): 106-14, 2010.
Article in English | MEDLINE | ID: mdl-20407733

ABSTRACT

PURPOSE: To evaluate the accuracy of retrospective rigid image registration and fusion between F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and magnetic resonance imaging (MRI) of the upper abdomen. PATIENTS, MATERIAL, METHODS: Image fusion of PET and MRI was performed in 30 patients with suspected malignancy of the liver or pancreas. Using a commercially available image fusion tool capable of rigid manual point-based registration, PET-Images were retrospectively registered and fused by matching eight homologous points in the 3D spoiled gradient echo (GRE) MRI sequences acquired in portal venous phase and in the CT-component of PET/CT. Two separate observers (R1, R2) assessed accuracy of image registration by determining the distances in the x-, y- and z-axis as well as the absolute distance between anatomical landmarks which differed from the landmarks chosen for registration. Quality of fusion was graded using a three point grading scale (1 poorly fused; 2 satisfactory fused; 3 correctly fused) and compared to hybrid PET/CT fusion. RESULTS: Mean time of registration per patient was less than 2 minutes. Objective registration assessment showed errors between 2.4-6.3 mm in x-axis: mean 3.6 mm (R1); 4.6 mm (R2), 2.3-9.3 mm in y-axis (mean 5.1 mm; 5.5 mm) and 3.3-12.0 mm in z-axis (mean 5.9 mm; 5.9 mm.) The mean error in absolute distance between points was 6.0-16.8 mm (mean 9.9 mm; 10.6 mm). In visual assessment, most fusions were graded to be satisfactory or correctly fused: R1, R2: grade 3, 11/30 (36.7%), 22/30 (73.3%); grade 2, 13/30 (43.3%), 8/30 (26.7%); grade 1, 6/30 (20%), 0/30 (0%). Fusions were mostly comparable to hybrid PET/CT fusions. All of the fusions were defined as diagnostically relevant by both observers. CONCLUSION: Retrospective rigid image fusion of FDG-PET and MRI of the upper abdomen using the CT-component of PET/CT for registration is feasible without adaptation in image acquisition protocols and shows sub-centimeter registration errors in most cases.


Subject(s)
Fluorodeoxyglucose F18 , Liver Neoplasms/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Adult , Aged , Aged, 80 and over , Body Size , Colonic Neoplasms/diagnostic imaging , Colonic Neoplasms/secondary , Female , Humans , Liver/anatomy & histology , Magnetic Resonance Imaging/methods , Male , Middle Aged , Observer Variation , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods
6.
Eur J Nucl Med Mol Imaging ; 36(11): 1774-82, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19495748

ABSTRACT

PURPOSE: The objective of this study was to evaluate the value of (18)F-FDG PET/CT and S-100B tumour marker for the detection of liver metastases from uveal melanoma in comparison to liver metastases from cutaneous melanoma. METHODS: A retrospective evaluation was conducted of 27 liver metastases in 13 patients with uveal melanoma (UM) (mean age: 56.8, range: 30-77) and 43 liver metastases in 14 patients (mean age: 57.9, range: 40-82) with cutaneous melanoma (CM) regarding size and FDG uptake by measuring the maximum standardized uptake value (SUV(max)). S-100B serum tumour markers were available in 20 patients. Cytology, histology, additional morphological imaging and follow-up served as reference standard. In nine patients liver metastases were further evaluated histologically regarding GLUT-1 and S-100 receptor expression and regarding epithelial or spindle cell growth pattern. RESULTS: Of 27 liver metastases in 6 of 13 patients (46%) with UM, 16 (59%) were FDG negative, whereas all liver metastases from CM were positive. Liver metastases from UM showed significantly (p < 0.001) lower SUV(max) (mean: 3.5, range: 1.5-13.4) compared with liver metastases from CM (mean: 6.6, range: 2.3-15.3). In four of six (66.7%) patients with UM and liver metastases S-100B was normal and in two (33.3%) increased. All PET-negative liver metastases were detectable by morphological imaging (CT or MRI). S-100B was abnormal in 13 of 14 patients with liver metastases from CM. S-100B values were significantly higher (p = 0.007) in the CM patient group (mean S-100B: 10.9 microg/l, range: 0.1-115 microg/l) compared with the UM patients (mean: 0.2 microg/l, range: 0.0-0.5 microg/l). Histological work-up of the liver metastases showed no obvious difference in GLUT-1 or S-100 expression between UM and CM liver metastases. The minority (36%) of patients with UM had extrahepatic metastases and the majority (86%) of patients with CM had extrahepatic metastases, respectively. There was a close to significant trend to better survival of UM patients compared with CM patients (p = 0.06). CONCLUSION: FDG PET/CT and serum S-100B are not sensitive enough for the detection of liver metastases from UM, whereas liver metastases from cutaneous melanoma are reliably FDG positive and lead regularly to increased S-100B tumour markers. The reason for the lower FDG uptake in UM liver metastases remains unclear. We recommend to perform combined contrast-enhanced PET/CT in order to detect FDG-negative liver metastases from UM.


Subject(s)
Fluorodeoxyglucose F18 , Liver Neoplasms/diagnosis , Liver Neoplasms/secondary , Melanoma/pathology , Nerve Growth Factors/blood , S100 Proteins/blood , Skin Neoplasms/pathology , Uveal Neoplasms/pathology , Adult , Aged , Aged, 80 and over , Biomarkers, Tumor/blood , Female , Fluorodeoxyglucose F18/metabolism , Humans , Liver Neoplasms/blood , Liver Neoplasms/metabolism , Male , Middle Aged , Positron-Emission Tomography , Prognosis , Retrospective Studies , S100 Calcium Binding Protein beta Subunit , Tomography, X-Ray Computed
7.
Eur J Nucl Med Mol Imaging ; 35(11): 2000-8, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18712385

ABSTRACT

OBJECTIVE: To evaluate the value of a dedicated interpretation of the CT images in the differential diagnosis of benign vs. malignant primary bone lesions with 18 fluorodeoxyglucose-positron emission tomography/computed tomography (18F-FDG-PET/CT). MATERIALS AND METHODS: In 50 consecutive patients (21 women, 29 men, mean age 36.9, age range 11-72) with suspected primary bone neoplasm conventional radiographs and 18F-FDG-PET/CT were performed. Differentiation of benign and malignant lesions was separately performed on conventional radiographs, PET alone (PET), and PET/CT with specific evaluation of the CT part. Histology served as the standard of reference in 46 cases, clinical, and imaging follow-up in four cases. RESULTS: According to the standard of reference, conventional 17 lesions were benign and 33 malignant. Sensitivity, specificity, and accuracy in assessment of malignancy was 85%, 65% and 78% for conventional radiographs, 85%, 35% and 68% for PET alone and 91%, 77% and 86% for combined PET/CT. Median SUV(max) was 3.5 for benign lesions (range 1.6-8.0) and 5.7 (range 0.8-41.7) for malignant lesions. In eight patients with bone lesions with high FDG-uptake (SUV(max) >or= 2.5) dedicated CT interpretation led to the correct diagnosis of a benign lesion (three fibrous dysplasias, two osteomyelitis, one aneurysmatic bone cyst, one fibrous cortical defect, 1 phosphaturic mesenchymal tumor). In four patients with lesions with low FDG-uptake (SUV(max) < 2.5) dedicated CT interpretation led to the correct diagnosis of a malignant lesion (three chondrosarcomas and one leiomyosarcoma). Combined PET/CT was significantly more accurate in the differentiation of benign and malignant lesions than PET alone (p = .039). There was no significant difference between PET/CT and conventional radiographs (p = .625). CONCLUSION: Dedicated interpretation of the CT part significantly improved the performance of FDG-PET/CT in differentiation of benign and malignant primary bone lesions compared to PET alone. PET/CT more commonly differentiated benign from malignant primary bone lesions compared with conventional radiographs, but this difference was not significant.


Subject(s)
Bone Neoplasms/diagnosis , Bone Neoplasms/pathology , Bone and Bones/pathology , Fluorodeoxyglucose F18 , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Bone Neoplasms/diagnostic imaging , Bone and Bones/diagnostic imaging , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Positron-Emission Tomography
8.
J Intern Med ; 263(1): 99-106, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18036160

ABSTRACT

AIM: Prevalence, optimal diagnostic approach and consequences of clinically unsuspected osteomyelitis in diabetic foot ulcers are unclear. Early diagnosis of this infection may be crucial to ensure correct management. METHODS: We conducted a prospective study in 20 diabetic patients with a chronic foot ulcer (>8 weeks) without antibiotic pretreatment and without clinical signs for osteomyelitis to assess the prevalence of clinically unsuspected osteomyelitis and to compare the value of magnetic resonance imaging (MRI), 18F-fluorodeoxyglucose positron emission tomography (18F-FDG PET) and 99mTc-labelled monoclonal antigranulocyte antibody scintigraphy (99mTc-MOAB). Those with suggestive scans underwent bone biopsy for histology (n = 7). RESULTS: Osteomyelitis was confirmed by biopsy in seven of the 20 clinically unsuspected foot ulcers. Presence of osteomyelitis was not related to age, ulcer size, ulcer duration, duration of diabetes or HbA1c. C-reactive protein was slightly elevated in patients with osteomyelitis (35.1 +/- 16.0 mg L(-1) vs. 12.2 +/- 2.6 mg L(-1) in patients with and without osteomyelitis respectively; P = 0.07). MRI was positive in six of the seven patients with proven osteomyelitis, whereas 18F-FDG PET and 99mTc-MOAB were positive only in (the same) two patients. Of the seven patients with osteomyelitis, five had lower limb amputation and in one patient the ulcer was persisting after 24 months of follow-up. In contrast, of the 13 patients without detectable signs of osteomyelitis on imaging modalities only two had lower limb amputation and two persisting ulcers. CONCLUSIONS: Clinically unsuspected osteomyelitis is frequent in persisting foot ulcers and is a high risk factor for adverse outcome. MRI appears superior to 18F-FDG PET and 99mTc-MOAB in detecting foot ulcer-associated osteomyelitis and might be the preferred imaging modality in patients with nonhealing diabetic foot ulcers.


Subject(s)
Diabetic Foot/diagnostic imaging , Fluorodeoxyglucose F18 , Magnetic Resonance Imaging , Osteomyelitis/diagnosis , Radiopharmaceuticals , Aged , Aged, 80 and over , Anti-Bacterial Agents/therapeutic use , Diabetic Foot/complications , Diabetic Foot/pathology , Female , Follow-Up Studies , Humans , Male , Middle Aged , Osteomyelitis/drug therapy , Osteomyelitis/microbiology , Positron-Emission Tomography , Radiography , Staphylococcus aureus/isolation & purification
9.
Infection ; 35(1): 11-8, 2007 Feb.
Article in English | MEDLINE | ID: mdl-17297583

ABSTRACT

BACKGROUND: Long-term benzimidazole therapy benefits patients with non-resectable alveolar echinococcosis (AE). Methods to assess early therapeutic efficacy are lacking. Recently, AE liver lesions were reported to exhibit increased F-18-fluorodeoxyglucose (FDG) uptake in positron emission tomography (PET). To assess the value of FDG-PET for diagnosis and follow-up of AE patients. PATIENTS/METHODS: Twenty-six consecutive patients with newly diagnosed AE were enrolled. Baseline evaluation included CT and FDG-PET. Thirteen patients (11 women; median age 50 years, range 40-76) were resected, the remaining 13 (8 women; median age 60 years, range 39-72) had non-resectable disease, were started on benzimidazoles, and CT and FDG-PET were repeated at 6, 12 and 24 months of therapy. Twelve consecutive patients with newly diagnosed cystic echinococcosis (CE) of the liver were also subjected to baseline FDG-PET. RESULTS: In 21/26 AE patients, baseline PET scans showed multifocally increased FDG uptake in the hepatic lesions' periphery, while liver lesions were FDG negative in 11/12 CE patients. Thus, sensitivity and specificity of FDG-PET for AE vs. CE were 81% and 92%, respectively. In 5 of 10 non-resectable patients with increased baseline FDG uptake, the intensity of uptake decreased (or disappeared) during benzimidazole therapy, in 3 by >or=2 grades within the initial 6 months. CONCLUSIONS: FDG-PET is a sensitive and specific adjunct in the diagnosis of suspected AE and can help in differentiating AE from CE. The rapid improvement of positive PET scans with benzimidazole therapy in some patients indicates that absent FDG uptake does not necessarily reflect parasite viability.


Subject(s)
Anthelmintics/therapeutic use , Benzimidazoles/therapeutic use , Echinococcosis, Hepatic/diagnosis , Fluorodeoxyglucose F18 , Liver/diagnostic imaging , Positron-Emission Tomography/methods , Radiopharmaceuticals , Adult , Aged , Animals , Diagnosis, Differential , Echinococcosis, Hepatic/drug therapy , Echinococcosis, Hepatic/parasitology , Echinococcus multilocularis/drug effects , Female , Humans , Liver/parasitology , Male , Middle Aged , Radiography , Sensitivity and Specificity
10.
Heart ; 93(1): 16-22, 2007 Jan.
Article in English | MEDLINE | ID: mdl-16387827

ABSTRACT

Positron emission tomography, cardiovascular magnetic resonance and multislice computed tomography have contributed to changing our pathophysiological understanding of many conditions. Clinically, they have provided new tools for the identification of preclinical disease and a better understanding of how disease progresses. The application of these imaging modalities to preclinical disease and the use of these techniques in patients with overt cardiovascular disease are reviewed.


Subject(s)
Cardiovascular Diseases/diagnosis , Coronary Disease/diagnosis , Humans , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods
11.
Praxis (Bern 1994) ; 94(35): 1331-7, 2005 Aug 31.
Article in German | MEDLINE | ID: mdl-16171004

ABSTRACT

Over the last years, PET has developed rapidly, with the most relevant indications being in oncologic imaging. Particularly since the introduction of PET-CT it is suggested that PET will become the imaging standard in oncologic staging and therapy monitoring in the near future in many tumors. This is due to the fact that PET measures molecular events such as glucose uptake and metabolism rather than anatomical changes. Despite this, anatomical information is frequently relevant for precise staging: hence, PET in the form of PET-CT is rapidly becoming the preferred way of imaging. In 2004, there were around 8000 PET examinations performed in Switzerland. A steady further increase is expected with around 2000 to 3000 PET examinations necessary per one million inhabitants per year. Other indications for PET are in neuro-, cardio- and inflammation imaging with substantial growth potential in all fields. The next promising clinical application of PET-CT may well be integrated PET-CT of the heart for the representation of coronary anatomy combined with quantitative myocardial perfusion as "cardiac-one-stop-shop".


Subject(s)
Neoplasms/diagnostic imaging , Positron-Emission Tomography/trends , Energy Metabolism/physiology , Forecasting , Humans , Image Enhancement , Image Processing, Computer-Assisted/trends , Neoplasm Staging , Neoplasms/pathology , Sensitivity and Specificity , Tomography, X-Ray Computed
12.
Eur J Nucl Med Mol Imaging ; 32(2): 153-62, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15690223

ABSTRACT

PURPOSE: Gastrointestinal stromal tumours (GIST) are mesenchymal neoplasms of the gastrointestinal tract that are unresponsive to standard sarcoma chemotherapy. Imaging of GIST patients is done with structural and functional methods such as contrast-enhanced helical computed tomography (ceCT) and positron emission tomography (PET) with 18F-fluorodeoxyglucose (FDG). The aim of this study was to compare the prognostic power of PET and ceCT and to evaluate the clinical role of PET/CT imaging. METHODS: All patients with GIST undergoing PET or PET/CT examinations were prospectively included in this study, and the median overall survival, time to progression and treatment duration were documented. The prognostic significance of PET and ceCT criteria of treatment response was assessed and PET/CT was compared with PET and ceCT imaging. Data for 34 patients (19 male, 15 female, 21-76 years) undergoing PET or PET/CT for staging or restaging were analysed. RESULTS: In 28 patients, PET/CT and ceCT were available after introduction of treatment with the tyrosine kinase inhibitor imatinib mesylate (Gleevec; Novartis, Basel, Switzerland). Patients without FDG uptake after the start of treatment had a better prognosis than patients with residual activity. In contrast, ceCT criteria provided insufficient prognostic power. However, more lesions were found on ceCT images than on PET images, and FDG uptake was sometimes very variable. PET/CT delineated active lesions better than did the combination of PET and ceCT imaging. CONCLUSION: Both PET and PET/CT provide important prognostic information and have an impact on clinical decision-making in GIST patients. PET/CT precisely delineates lesions and thus allows for the correct planning of surgical interventions.


Subject(s)
Fluorodeoxyglucose F18 , Gastrointestinal Neoplasms/diagnosis , Gastrointestinal Neoplasms/drug therapy , Piperazines/therapeutic use , Positron-Emission Tomography/methods , Pyrimidines/therapeutic use , Tomography, X-Ray Computed/methods , Adult , Aged , Antineoplastic Agents/therapeutic use , Benzamides , Disease-Free Survival , Female , Follow-Up Studies , Gastrointestinal Neoplasms/mortality , Humans , Imatinib Mesylate , Longitudinal Studies , Male , Middle Aged , Prognosis , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity , Survival Analysis , Switzerland/epidemiology , Treatment Outcome
14.
Eur J Neurosci ; 20(10): 2664-70, 2004 Nov.
Article in English | MEDLINE | ID: mdl-15548209

ABSTRACT

Oxidative metabolism and cerebral blood flow (CBF) are two of the most important measures in neuroimaging. However, results from concurrent imaging of the two with high spatial and temporal resolution have never been published. We used flavoprotein autofluorescence (AF) and laser speckle imaging (LSI) in the anaesthetized rat to map oxidative metabolism and CBF in response to single vibrissa stimulation. Autofluorescence responses reflecting oxidative metabolism demonstrated a fast increase with a delay of 0.1 s. The sign-reversed speckle contrast reflecting CBF started to rise with a delay of 0.6 s and reached its maximum 1.4 s after the stimulation offset. The fractional signal changes were 2.0% in AF and 9.7% in LSI. Pixelwise modelling revealed that CBF maps spread over an area up to 2.5-times larger than metabolic maps. The results provide evidence that the increase in cerebral oxidative metabolism in response to sensory stimulation is considerably faster and more localized than the CBF response. This suggests that future developments in functional imaging concentrating on the metabolic response promise an increased spatial resolution.


Subject(s)
Cerebral Cortex/physiology , Cerebrovascular Circulation/physiology , Vibrissae/physiology , Animals , Cerebral Cortex/blood supply , Flavoproteins/metabolism , Image Processing, Computer-Assisted , Laser-Doppler Flowmetry , Lasers , Magnetic Resonance Imaging/methods , Male , Oxygen/blood , Physical Stimulation/methods , Rats , Rats, Sprague-Dawley , Reaction Time , Regional Blood Flow/physiology , Vibrissae/innervation
15.
Eur Heart J ; 25(18): 1657-65, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15351166

ABSTRACT

AIMS: Magnetic resonance (MR) first-pass myocardial perfusion imaging during hyperaemia detects coronary artery stenoses in humans with test sensitivity depending on contrast medium (CM)-induced signal change in myocardium. In this prospective multi-centre study, the effect of CM dose on myocardial signal change and on diagnostic performance was evaluated using a stress-only approach. METHODS AND RESULTS: Ninety-four patients with known or suspected coronary artery disease (CAD) were randomised to 0.05,0.10, or 0.15 mmol/kg body weight of an extravascular CM (Gd-DTPA) and X-ray coronary angiography was performed within 30 days prior/after the MR examination. A multi-slice MR technique with identical hardware and software in all centres was used during hyperaemia (adenosine 0.14 mg/kg/min) to monitor myocardial CM wash-in kinetics and data were analysed semi-automatically in a core laboratory. Protocol violations resulted in 80 complete studies with CAD (defined as > or =1 vessel with diameter stenosis > or =50% on quantitative coronary angiography) present in 19/29, 13/24, and 20/27 patients for doses 1, 2, and 3, respectively. In normal myocardium, the upslope increased with CM dose (overall-p<0.0001, ANOVA). For CAD detection the area under the receiver operator characteristics curve for subendocardial data (3 slices with quality score<4 representing 86% of cases) was 0.91+/-0.07 and 0.86+/-0.08 for doses 2 and 3, respectively, and was lower for dose 1 (0.53+/-0.13, p<0.01 and p<0.02 vs. doses 2 and 3, respectively). Corresponding sensitivities/specificities (95% confidence intervals) for pooled doses 2/3 were 93% (77-99%; ns vs. dose 1) and 75% (48-92%;p<0.05 vs. dose 1), respectively. CONCLUSIONS: With increasing doses of CM, a higher signal response in the myocardium was achieved and consequently this stress-only protocol, with CM doses of 0.10-0.15 mmol/kg combined with a semi-automatic analysis, yielded a high diagnostic performance for the detection of CAD.


Subject(s)
Contrast Media/administration & dosage , Coronary Artery Disease/diagnosis , Magnetic Resonance Angiography/methods , Analysis of Variance , Female , Humans , Male , Middle Aged , Risk Factors
16.
Oral Oncol ; 39(6): 547-51, 2003 Sep.
Article in English | MEDLINE | ID: mdl-12798396

ABSTRACT

The aim of this study is to evaluate the additional clinical information provided by whole body positron emission tomography (PET) with fluorodeoxyglucose (FDG) for initial staging of patients with squamous cell carcinoma (SCC) of the oral cavity. PET scans from the head to the pelvic floor of 34 consecutive patients (22 male, 12 female; mean age 71 years) with histologically confirmed SCC of the oral cavity were retrospectively evaluated. Clinical information including CT of the head and neck and chest X-Ray or chest CT was compared with information on nodal involvement and distant metastases or secondary tumours obtained with PET. The primary tumour was identified with PET in 33 of 34 patients (97%). In 27 Patients (81%) the clinical N-stage was confirmed with PET. In two Patients (6%) additional pathologic loco-regional lymph nodes were found. In five patients more lymph nodes were identified with CT. Distant lesions were seen with PET imaging in bone, lung, mediastinum, liver and colon. In three patients (6%) distant metastases were correctly identified. In another four patients (12%) a secondary cancer was detected. One false positive finding was described with PET. In five of 34 patients (15%) the additional findings as revealed with PET lead to a change of treatment. Whole body PET provides relevant additional information to a standard clinical staging procedure in patients with oral cavity SCC. The detection of distant metastases and secondary primary tumours can have a great impact on patient management.


Subject(s)
Carcinoma, Squamous Cell/diagnostic imaging , Image Processing, Computer-Assisted , Mouth Neoplasms/diagnostic imaging , Neoplasms, Multiple Primary/diagnostic imaging , Tomography, Emission-Computed , Aged , Aged, 80 and over , Carcinoma, Squamous Cell/pathology , Carcinoma, Squamous Cell/therapy , Female , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Mouth Neoplasms/pathology , Mouth Neoplasms/therapy , Neoplasm Metastasis , Neoplasm Staging , Neoplasms, Multiple Primary/pathology , Neoplasms, Multiple Primary/therapy , Radiopharmaceuticals , Retrospective Studies , Sensitivity and Specificity , Tomography, X-Ray Computed
18.
Eur J Nucl Med Mol Imaging ; 29(7): 922-7, 2002 Jul.
Article in English | MEDLINE | ID: mdl-12111133

ABSTRACT

The CT data acquired in combined PET/CT studies provide a fast and essentially noiseless source for the correction of photon attenuation in PET emission data. To this end, the CT values relating to attenuation of photons in the range of 40-140 keV must be transformed into linear attenuation coefficients at the PET energy of 511 keV. As attenuation depends on photon energy and the absorbing material, an accurate theoretical relation cannot be devised. The transformation implemented in the Discovery LS PET/CT scanner (GE Medical Systems, Milwaukee, Wis.) uses a bilinear function based on the attenuation of water and cortical bone at the CT and PET energies. The purpose of this study was to compare this transformation with experimental CT values and corresponding PET attenuation coefficients. In 14 patients, quantitative PET attenuation maps were calculated from germanium-68 transmission scans, and resolution-matched CT images were generated. A total of 114 volumes of interest were defined and the average PET attenuation coefficients and CT values measured. From the CT values the predicted PET attenuation coefficients were calculated using the bilinear transformation. When the transformation was based on the narrow-beam attenuation coefficient of water at 511 keV (0.096 cm(-1)), the predicted attenuation coefficients were higher in soft tissue than the measured values. This bias was reduced by replacing 0.096 cm(-1) in the transformation by the linear attenuation coefficient of 0.093 cm(-1) obtained from germanium-68 transmission scans. An analysis of the corrected emission activities shows that the resulting transformation is essentially equivalent to the transmission-based attenuation correction for human tissue. For non-human material, however, it may assign inaccurate attenuation coefficients which will also affect the correction in neighbouring tissue.


Subject(s)
Fluorodeoxyglucose F18 , Image Enhancement/methods , Neoplasms/diagnostic imaging , Tomography, Emission-Computed/instrumentation , Tomography, X-Ray Computed/instrumentation , Calibration , Humans , Models, Biological , Phantoms, Imaging , Protons , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity , Tomography, Emission-Computed/methods , Tomography, X-Ray Computed/methods
19.
J Magn Reson Imaging ; 14(5): 556-62, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11747007

ABSTRACT

Fast imaging techniques allow monitoring of contrast medium (CM) first-pass kinetics in a multislice mode. Employing shorter recovery times improves cardiac coverage during first-pass conditions, but potentially flattens signal response in the myocardium. The aim of this study was therefore to compare in patients with suspected coronary artery disease (CAD) two echo-planar imaging strategies yielding either extended cardiac coverage or optimized myocardial signal response (protocol A/B, six/four slices; preparation pulse, 60 degrees /90 degrees; delay time, 10/120 msec; readout flip angle, 10 degrees /50 degrees; respectively). In phantoms and myocardium of normal volunteers (N= 10) the CM-induced signal increase was 2.5-3 times higher with protocol B (P < 0.005) than with protocol A. For the detection of individually diseased coronary arteries (> or =1 stenosis with > or =50% diameter reduction on quantitative coronary angiography (QCA)), receiver-operator characteristics of protocol B (signal upslope in 32 sectors/heart) yielded a sensitivity/specificity of 82%/73%, which was superior to protocol A (P < 0.05, N= 14). For the overall detection of CAD, the sensitivity/specificity of protocol B was 85%/81%. An adequate signal response in the myocardium is crucial for a reliable detection of perfusion deficits during first-pass conditions. The presented protocol B detects CAD with a sensitivity and specificity similar to scintigraphic techniques.


Subject(s)
Coronary Disease/diagnosis , Echo-Planar Imaging/methods , Myocardium/pathology , Heart/anatomy & histology , Humans , Phantoms, Imaging , ROC Curve , Sensitivity and Specificity , Signal Processing, Computer-Assisted
20.
Radiology ; 221(3): 818-21, 2001 Dec.
Article in English | MEDLINE | ID: mdl-11719684

ABSTRACT

An infected cyst in autosomal dominant polycystic kidney disease was identified with a combined positron emission tomographic (PET) and computed tomographic (CT) system, an experimental setup mimicking an integrated CT-PET scanner. Image fusion of fluorine 18 fluorodeoxyglucose PET and CT images allowed exact localization of the infected cyst among many cysts identified on previous CT and magnetic resonance images. Confirmation was obtained instantly, followed by CT-guided percutaneous puncture. Integrated imaging systems hold promise for direct PET-guided puncture of areas of increased fluorodeoxyglucose uptake by using the anatomic accuracy of CT.


Subject(s)
Escherichia coli Infections/therapy , Image Processing, Computer-Assisted , Polycystic Kidney, Autosomal Dominant/therapy , Punctures , Radiography, Interventional , Tomography, Emission-Computed , Tomography, X-Ray Computed , Escherichia coli Infections/complications , Escherichia coli Infections/diagnostic imaging , Fluorodeoxyglucose F18 , Humans , Kidney/diagnostic imaging , Male , Middle Aged , Polycystic Kidney, Autosomal Dominant/complications , Polycystic Kidney, Autosomal Dominant/diagnostic imaging , Punctures/methods , Radiopharmaceuticals
SELECTION OF CITATIONS
SEARCH DETAIL
...