Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Artif Organs ; 44(9): 947-954, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32645761

ABSTRACT

Establishing a chronic heart failure (HF) model is challenging, particularly in the ovine model. The aim of this study was to establish a reproducible model of HF in an ovine model. Seventeen sheep were operated using the left thoracotomy approach. Chronic HF was induced through ligation of the diagonal and marginal branches only. Perioperative hemodynamic and echocardiographic parameters were compared. A total of (3 ± 1) coronary ligations were used. Thirteen animals survived the procedure and were followed up for (15 ± 5) days. The mean arterial pressure, heart rate (HR), mean pulmonary artery pressure (mPAP), central venous pressure, and cardiac output at baseline and prior to animal sacrifice was (75 ± 14 mmHg) and (68 ± 16 mmHg) P = .261; (72 ± 9 bpm), (100 ± 28 bpm) P = .01; (15 ± 4 mmHg) and (18 ± 5 mmHg) P = .034; (10 ± 6 mmHg) and (8 ± 4 mmHg) P = .326; (3.4 ± 1 L/min) and (3.9 ± 1 L/min) P = .286, respectively. The LVEF at baseline and prior to animal sacrifice was (63 ± 13%) and (43 ± 6%) P = .012. Twelve surviving animals were supported with LVAD in a follow-up procedure. Chronic stable HF in sheep was successively established. Clinical symptoms and drastic increase in the mPAP and HR as well as echo findings were the most sensitive parameters of HF. This reproducible ovine model has proven to be highly promising for research regarding HF.


Subject(s)
Disease Models, Animal , Heart Failure/etiology , Hemodynamics/physiology , Animals , Coronary Vessels/surgery , Echocardiography , Female , Heart Failure/diagnosis , Heart Failure/physiopathology , Heart Failure/surgery , Heart-Assist Devices , Humans , Ligation , Sheep
2.
JTCVS Open ; 4: 16-23, 2020 Dec.
Article in English | MEDLINE | ID: mdl-36004302

ABSTRACT

Objective: To evaluate the impact of severe tricuspid valve insufficiency (TVI) at the time of left ventricular assist device (LVAD) implantation on the hemodynamic and LVAD parameters in an acute ovine model. Methods: Stable heart failure (HF) was induced in 10 ovines through the application of 3 ± 1 coronary ligations. Once stable HF was obtained (after 15 ± 5 days), the animals were supported with an LVAD. Hemodynamic data and pump parameters were obtained and compared in 2 settings; first with LVAD in place after weaning from the cardiopulmonary bypass machine (no TVI condition) and second following the induction of severe TVI through resection of the tricuspid valve (TVI condition). Results: There were no statistically significant differences in the hemodynamic and pump parameters between TVI condition and no TVI conditions except for lower cardiac output in the TVI condition (2 [1.38-2.8] L/min vs 3.2 [1.55-3.7] L/min, P = .027) and the expected greater central venous pressure in the TVI condition (26 [24-31] mm Hg vs 15 [13-25] mm Hg, P = .020). A median pump flow of 2.8 (2.45-3.75) L/min versus 2.9 (2.75-3.8) L/min in the TVI condition and no TVI condition was documented (P = .160). Conclusions: Results from this acute animal study suggest that severe TVI in HF with preserved right ventricular function does not have significant impact on the LVAD pump parameters. The observed reduction in cardiac output may warrant further investigations, especially under loading conditions.

SELECTION OF CITATIONS
SEARCH DETAIL
...