ABSTRACT
OBJECTIVE: To assess the efficacy and safety of micafungin versus fluconazole for prophylaxis and treatment of fun¬gal infections.
ABSTRACT
Objective:To optimize the injection protocol of contrast medium for contrast-enhanced MRA (CEMRA) of pulmonary artery and to evaluate the diagnostic value of CEMRA and pulmonary perfusion imaging (PPI) in an experimental model of acute pulmonary embolism. Methods:CEMRA and PPI were performed in 6 normal pigs with different doses of gadolinium contrast agent (5ml, 10ml, 15ml, 20ml and 25ml) at an injection rate of 3ml/s, and 3 pulmonary embolism models were injected with 20 ml contrast agent at 3 ml/s. DSA was also performed for comparison. Results:The signal intensities and the signal to noise ratios of the pulmonary arteries kept increasing with the dose increase of the contrast agent, but the best angio-pulmonary contrast dose was 10-15ml (0.25-0.375mmol/kg), while the optimal dose for PPI was 15-20ml (0.375-0.5mmol/kg). Although CEMRA demonstrated less obstructed pulmonary arteries than DSA (5/10 vs 8/10)did, it detected all obstructions when combined with PPI. The pulmonary infarction zones showed wedge-shaped perfusion defects on the PPI images, with the signal intensities lower than those of the normal areas (137.86±45.32 vs 330.14±46.52, P<0.001). Conclusion:It is suggested that the optimal dose of the contrast agent is 0.25mmol/kg to 0.375mmol/kg for CEMRA, and 0.375mmol/kg to 0.5mmol/kg for lung perfusion. CEMRA combined with PPI may be better than DSA in demonstrating pulmonary embolism.
ABSTRACT
Objective:To optimize the injection protocol of contrast medium for contrast-enhanced MRA (CEMRA) of pulmonary artery and to evaluate the diagnostic value of CEMRA and pulmonary perfusion imaging (PPI) in an experimental model of acute pulmonary embolism. Methods:CEMRA and PPI were performed in 6 normal pigs with different doses of gadolinium contrast agent (5ml, 10ml, 15ml, 20ml and 25ml) at an injection rate of 3ml/s, and 3 pulmonary embolism models were injected with 20 ml contrast agent at 3 ml/s. DSA was also performed for comparison. Results:The signal intensities and the signal to noise ratios of the pulmonary arteries kept increasing with the dose increase of the contrast agent, but the best angio-pulmonary contrast dose was 10-15ml (0.25-0.375mmol/kg), while the optimal dose for PPI was 15-20ml (0.375-0.5mmol/kg). Although CEMRA demonstrated less obstructed pulmonary arteries than DSA (5/10 vs 8/10)did, it detected all obstructions when combined with PPI. The pulmonary infarction zones showed wedge-shaped perfusion defects on the PPI images, with the signal intensities lower than those of the normal areas (137.86±45.32 vs 330.14±46.52, P<0.001). Conclusion:It is suggested that the optimal dose of the contrast agent is 0.25mmol/kg to 0.375mmol/kg for CEMRA, and 0.375mmol/kg to 0.5mmol/kg for lung perfusion. CEMRA combined with PPI may be better than DSA in demonstrating pulmonary embolism.
ABSTRACT
Objective To study the effects of glycogen synthase kinase-3?(GSK-3?)and free radical on neuron apoptosis of hypoxic-ischemic brain damage(HIBD)in newborn rats.Methods Eighty 7-day-old neonatal rats were randomly divided into 2 groups:normal group and hypoxic-ischemic(HI)group.Rats in HI group were subjected to left common carotid artery ligation,exposed to 80 mL/L oxygen and 920 mL/L nitrogen gas in 37 ℃ closed container for 2.5 h.Rats in 2 groups were killed at 6 hours,24 hours,48 hours,72 hours,5 days after hypoxia respectively.The neuron apoptosis was detected by flow cytometry.The activity of GOD-PX and the contents of SOD and MDA were detected by spectrophotometry,the level of GSK-3? was mensurated by Enzyme-linked immumosorbent assay(ELISA).Results The rates of neuronal apoptosis in HI group were significantly higher than those in normal group at 6,24,48 and 72 hours after hypoxia,respectively(Pa