Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 113
Filter
1.
J Egypt Natl Canc Inst ; 36(1): 11, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38584227

ABSTRACT

BACKGROUND: The moderate deep inspiratory breath hold (mDIBH) is a modality famed for cardiac sparing. Prospective studies based on this are few from the eastern part of the world and India. We intend to compare the dosimetry between mDIBH and free-breathing (FB) plans. METHODS: Thirty-two locally advanced left breast cancer patients were taken up for the study. All patients received a dose of 50 Gy in 25 fractions to the chest wall/intact breast, followed by a 10-Gy boost to the lumpectomy cavity in the case of breast conservation surgery. All the patients were treated in mDIBH using active breath coordinator (ABC). The data from the two dose volume histograms were compared regarding plan quality and the doses received by the organs at risk. Paired t-test was used for data analysis. RESULTS: The dose received by the heart in terms of V5, V10, and V30 (4.55% vs 8.39%) and mean dose (4.73 Gy vs 6.74 Gy) were statistically significant in the ABC group than that in the FB group (all p-values < 0.001). Also, the dose received by the LADA in terms of V30 (19.32% vs 24.87%) and mean dose (32.99 Gy vs 46.65 Gy) were significantly less in the ABC group. The mean treatment time for the ABC group was 20 min, while that for the free-breathing group was 10 min. CONCLUSIONS: Incorporating ABC-mDIBH for left-sided breast cancer radiotherapy significantly reduces the doses received by the heart, LADA, and left and right lung, with no compromise in plan quality but with an increase in treatment time.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Female , Breath Holding , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/radiotherapy , Prospective Studies , Heart , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Organs at Risk
2.
J Pers Med ; 14(1)2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38248764

ABSTRACT

A comparison of the radiation exposure to the left anterior descending artery (LAD) and left ventricle (LV) was performed for twenty-three left breast cancer patients. For each participant, two tangential fields 3D-CRT, two- and seven-field IMRT and two and four partial arcs VMAT plans were created. Dose constraints for CTV, ipsilateral lung and heart were followed. The V40Gy, V30Gy, Dav of LAD and V23Gy, V5Gy, Dav of LV were calculated and extracted from the plans. Parametric and non-parametric tests were applied to compare the parameters derived from the five treatment techniques. All generated plans fulfilled the dose constraints. The Dav ranges of the LAD and LV from all examined techniques were 11.77-14.73 Gy and 5.37-6.40 Gy, respectively. The V40Gy and V30Gy ranges of the LAD were 2.90-12.91% and 10.80-18.51%, respectively. The V23Gy and V5Gy of the LV were 4.29-7.43% and 18.24-30.05%, respectively. The VMAT plans and seven-field IMRT significantly reduced the V40Gy, V30Gy of LAD and V23Gy of LV compared with the two-field treatments (p < 0.05). However, 3D-CRT plans provided statistically lower values for V5Gy of LV over the other techniques (p < 0.05). The presented results provide a detailed dataset of the radiation burden of two critical cardiac structures from five radiotherapy techniques.

3.
J Med Imaging Radiat Sci ; 55(1): 37-44, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38042641

ABSTRACT

INTRODUCTION: Ultra-hypofractionated radiotherapy (UHF-RT) mandates more accuracy in each part of the treatment cycle to maximize cure rates and minimize toxicities. In vivo dosimetry is a direct method for verifying overall treatment accuracy. This study evaluated uncertainties in the delivered dose of Hypofractionated (HF) and UHF Whole Breast Irradiation (WBI) and to analyze the accuracy of the workflow to pave the way for a wide-scale use of UHF-RT. METHODS: Thirty-three breast cancer cases, including 16 HF-WBI and 17 UHF-WBI were treated with 3D conformal Radiotherapy (3D-CRT), where 79 fields were analyzed for dose verification. The measurement point was set at the beam entrance (1.5 cm depth). The expected dose at Dmax was calculated via TPS. Before in vivo measurements, diode detectors were tested and calibrated. We developed initial validation measurements for UHF-RT on an anthropomorphic breast phantom for the first time. RESULTS: For RANDO phantom, the percentage difference between measured and calculated doses showed an average of -0.52 ± 5.4%, in addition to an excellent dose reproducibility within 0.6%. The overall in vivo measurements for studied cases showed that 83.5% of the measured doses were within ±5% and only 1.8% of the measured doses were greater than ±10% of the calculated doses. The percentage accuracy was slightly larger for UHF cohort (84.2%) compared to HF cohort (83.2%). The maximum percentage difference between them was less than 1%. CONCLUSION: Breast in vivo dosimetry is an adequate tool for treatment verification that improves the accuracy of the treatment cycle. UHF-RT may contribute in reducing the long waiting lists, increasing patient convenience, and saving the available resources for breast cancer patients.


Subject(s)
Breast Neoplasms , Radiotherapy, Conformal , Humans , Female , Reproducibility of Results , Breast , Radiotherapy, Conformal/methods , Breast Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods
4.
Head Neck ; 46(2): 239-248, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37933710

ABSTRACT

BACKGROUND: We evaluated clinical and dosimetric outcomes of radiotherapy using two anterior oblique portals (AOP), to reduce the dose to the bilateral internal carotid arteries (CAs) and pharyngeal constrictor muscle (PCM) during early-stage glottic cancer (ESGC) treatment. METHODS: We identified patients with ESGC who underwent definitive radiotherapy between June 2014 and May 2020. RESULTS: Among the 66 patients, 32 (48%) underwent radiotherapy using AOP, and the remaining underwent typical radiotherapy using parallel opposed lateral portals (POLP). The median follow-up duration was 53 months. No significant differences were observed in the 5-year local failure (0%/9.4%), progression-free survival (90.6%/90.8%), and overall survival (90.6%/91.0%) rates between the two groups. The grade ≥2 acute mucositis incidence rate was significantly lower in the AOP group (44%/85%). Radiotherapy using AOP maintained an adequate dose coverage to the target while markedly reducing the CAs and PCM doses. CONCLUSION: Radiotherapy with AOP resulted in favorable clinical and dosimetric outcomes.


Subject(s)
Laryngeal Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Carotid Artery, Internal , Laryngeal Neoplasms/radiotherapy , Laryngeal Neoplasms/etiology , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Muscles , Radiotherapy Dosage
5.
Asian Pac J Cancer Prev ; 24(11): 3859-3866, 2023 11 01.
Article in English | MEDLINE | ID: mdl-38019244

ABSTRACT

Objective: To determine radiation dose volume threshold in predicting the development of hypothyroidism in cancer patients following neck irradiation. Methods: This is a cross sectional follow up study for patients who had been previously irradiated, prior to enrolment in the study. We have done thyroid dose-volumetric analysis on 120 histologically proven cancer patients in the age group of 18-75 years who received neck irradiation as a part of their definitive or adjuvant radiotherapy with three-dimensional conformal or intensity-modulated radiotherapy technique (3D -CRT or IMRT) and completed at least six months post-radiotherapy. Primary tumor sites included carcinoma or lymphoma of the head and neck, breast, cervical, and upper thoracic esophagus, requiring neck irradiation. Results: The proportion of patients who tested positive for Radiation induced hypothyroidism (RIHT) was found to be 40%, with clinical hypothyroidism and subclinical hypothyroidism being 25.8% and 14.2%, respectively. Time to develop hypothyroidism peaks around two years. Mean thyroid gland dose (Dmean) >28 Gy, thyroid gland volume receiving 40 Gy dose (i.e. V40) >49% and age <50 years were found to be significant risk factors for the development of RIHT on binary logistic regression. RT dose >50 Gy and thyroid gland volume spared from 40 Gy (i.e. VS40) < 2.12cm3 were statistically significant predictors for RIHT on chi-square and (Receiver operating characteristic) ROC curve analysis respectively but not on regression analysis. Conclusion: Dose-volume threshold for the thyroid gland as Dmean <28 Gy and V40 <49% may prevent the development of RIHT.


Subject(s)
Carcinoma , Hypothyroidism , Humans , Adolescent , Young Adult , Adult , Middle Aged , Aged , Cross-Sectional Studies , Follow-Up Studies , Hypothyroidism/etiology
6.
J Cancer ; 14(15): 2878-2888, 2023.
Article in English | MEDLINE | ID: mdl-37781069

ABSTRACT

Objective: Prostate cancer (PCa) is one of the most common cancers in the world. The potential benefits of intensity modulated radiation therapy (IMRT) over three-dimensional conformal radiation therapy (3D-CRT) for PCa primary radiation therapy treatment have not yet been clarified. Therefore, this meta-analysis was conducted to assess whether IMRT could improve clinical outcomes in comparison with 3D-CRT in patients diagnosed with PCa. Materials and methods: Relevant studies were identified through searching related databases till December, 2022. Hazard ratio (HR) or risk ratio (RR) with its corresponding 95% confidence interval (CI) was used as pooled statistics for all analyses. Results: The incidence of grade 2 or worse acute adverse gastrointestinal (GI) event was analyzed and the pooled data revealed a clear decreasing trend in the IMRT compared with 3D-CRT (RR=0.62, 95% CI: 0.45-0.84, p=0.002). IMRT slightly increased the grade ≥ 2 acute genitourinary (GU) adverse event in comparison with the 3D-CRT (RR=1.10, 95% CI: 1.02-1.19, p=0.015). The IMRT and the 3D-CRT of patients showed no substantial differences in grade ≥ 2 late GI adverse event (RR =0.62, 95% CI: 0.36-1.09, p=0.1). In those included studies, there was no significant difference between IMRT and 3D-CRT in grade 2-4 late GU adverse event (RR =1.08, 95% CI: 0.77-1.51, p=0.65). There was a significant difference in biochemical control favoring IMRT (RR =1.13, 95% CI: 1.05-1.22, p=0.002). IMRT showed modest increase in biochemical control in comparison with 3D-CRT. Conclusion: In general, based on the above results, IMRT should be considered as a better choice for the treatment of PCa. More randomized controlled trials are needed to determine the subset of patients diagnosed with PCa.

7.
Rep Pract Oncol Radiother ; 28(4): 445-453, 2023.
Article in English | MEDLINE | ID: mdl-37795228

ABSTRACT

Background: The study was to evaluate the effectiveness of dose distribution of four-dimensional computed tomography (4DCT) simulation. Materials and methods: The gross tumor volume (GTV) and clinical target volume (CTV) were contoured in all 10 respiratory phases of 4DCT in 30 patients with non-small cell lung cancer (NSCLC). Both 3D and 4D treatment plans were made individually for each patient using the planning volume (PTV). The PTV3D was taken from a single CTV plus the recommended margin, and the PTV4D was taken from the 4D internal target volume, including all 10 CTVs plus the setup margins. Results: The mean PTV was 460 ± 179 (69-820) cm3 for 3DCT and 401 ± 167 (127-854) cm3 for 4DCT (p = 0.0018). The dose distribution (DD) of organs at risk, especially the lungs, was lower for the 4DCT simulation. The V5%, V10%, and V20% of the total lung dose for 4DCT were significantly lower for the 3DCT. However, lung V30% the heart, esophagus, and spinal cord were not significantly different. In addition, the conformity index and the dose heterogeneity index of the PTV were not significantly different. The normal tissue complication probability (NTCP) of the lung and heart was significantly lower for 4DCT than for 3DCT. Conclusions: The 4DCT simulation gives better results on the NTCP. The organs at risk, especially the lungs, receive a significantly lower DD compared with the 3DCT. The conformity index (CI), heterogeneity index (HI) and the DD to the heart, spinal cord, and esophagus were not significantly different between the two techniques.

8.
J Appl Clin Med Phys ; 24(10): e14042, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37679969

ABSTRACT

BACKGROUND: To evaluate the possible advantages of a simple spinal cord (SC) dose-limiting three-dimensional conformal radiotherapy (3D-CRT) technique in comparison to conventional two-dimensional (2D) techniques and other 3D-CRT techniques for spinal bone irradiation. METHODS: For 41 spinal target volumes, seven different techniques were evaluated, using a standard schedule of 30 Gy in 10 fractions. The SC dose-limiting 3D-CRT technique 1F2S-18MV using a single posterior field (F) supplemented by two anterior segment fields (S) and 18-MV photon beams was compared to two conventional 2D techniques (a single posterior field, PA, and two opposed anterior-posterior fields, APPA), three other 3D-CRT techniques (a single posterior field supplemented by four segment fields, 1F4S; two wedged fields, WD, and the SC dose-limiting variant using 6 MV, 1F2S-6MV) along with the original clinically applied plans. RESULTS: 1F2S-18MV demonstrated notably better results for all target volume parameters compared to the conventional 2D techniques (p < 0.001). Limitation of the SC dose was significantly superior with 1F2S-18MV in comparison to PA and APPA (SC Dmean: 28.9 ± 0.4  vs. 30.1 ± 0.6 Gy and 30.1 ± 0.4 Gy; SC Dmax: 30.9 ± 0.7  vs. 32.5 ± 1.0 Gy and 31.8 ± 0.7 Gy; SC D1cm3 : 30.1 ± 0.6  vs. 31.7 ± 0.9 Gy and 31.1 ± 0.6 Gy; p < 0.001). Likewise, lower mean SC doses with 1F2S-18MV were observed in comparison to the more treatment time-consuming 3D-CRT techniques (1F4S, WD) and the original plans without relevant compromises on the dose homogeneity in the target volume and the dose exposure to the other OARs. CONCLUSION: In treatment planning of spinal metastases, simple variants of 3D-CRT-techniques like 1F2S-18MV can offer a significant dose limitation to the SC while providing a sufficient dose coverage of the target volume. Especially in patients with favorable life expectancy and potential need for re-irradiation, such SC dose-limiting 3D-CRT techniques may be a reasonable approach.


Subject(s)
Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Spinal Neoplasms , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Spinal Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Spinal Cord , Radiotherapy, Intensity-Modulated/methods
9.
Curr Oncol ; 30(8): 7740-7752, 2023 08 19.
Article in English | MEDLINE | ID: mdl-37623042

ABSTRACT

This study provided normal tissue complication probability (NTCP) calculations from photon radiotherapy techniques in eleven patients with thymoma. Five plans were created for each participant using three-dimensional conformal radiotherapy (3D-CRT), five-field intensity modulated radiotherapy (5F-IMRT), seven-field IMRT (7F-IMRT), and volumetric modulated arc therapy with full arcs (FA-VMAT) and partial arcs (PA-VMAT). The target coverage, homogeneity index and conformation number for the planning target volume (PTV) and dosimetric parameters for the organs-at-risk (OARs) were taken from the fifty-five generated plans. The patient-specific NTCP of the lungs, heart and esophagus was calculated with an in-house software tool using differential dose-volume histograms and the equivalent uniform dose model. The PTV dose metrics from 3D-CRT were inferior to those from IMRT and VMAT plans. The dose constraints for the OARs were met in all treatment plans. The NTCP range of the lungs, heart and esophagus was 0.34-0.49%, 0.03-0.06% and 0.08-0.10%, respectively. The NTCPs of the heart for the incidence of peridarditis from IMRT and VMAT were significantly smaller than those from conformal treatment (p < 0.05). The 7F-IMRT was significantly superior to FA-VMAT in reducing the NTCP of the lungs and the risk of pneumonitis (p = 0.001). Similar superiority of 5F-IMRT over PA-VMAT for lung protection was found (p = 0.009). The presented results may be employed in the selection of the appropriate irradiation technique for restricting the complications in the adjacent OARs.


Subject(s)
Radiotherapy , Thymoma , Thymoma/radiotherapy , Humans , Male , Female , Middle Aged , Radiotherapy Dosage , Radiotherapy/instrumentation , Radiotherapy/methods , Retrospective Studies
10.
Med Phys ; 50(9): 5745-5756, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37427669

ABSTRACT

BACKGROUND: Pre-clinical ultra-high dose rate (UHDR) electron irradiations on time scales of 100 ms have demonstrated a remarkable sparing of brain and lung tissues while retaining tumor efficacy when compared to conventional dose rate irradiations. While clinically-used gantries and intensity modulation techniques are too slow to match such time scales, novel very-high energy electron (VHEE, 50-250 MeV) radiotherapy (RT) devices using 3D-conformed broad VHEE beams are designed to deliver UHDR treatments that fulfill these timing requirements. PURPOSE: To assess the dosimetric plan quality obtained using VHEE-based 3D-conformal RT (3D-CRT) for treatments of glioblastoma and lung cancer patients and compare the resulting treatment plans to those delivered by standard-of-care intensity modulated photon RT (IMRT) techniques. METHODS: Seven glioblastoma patients and seven lung cancer patients were planned with VHEE-based 3D-CRT using 3 to 16 coplanar beams with equidistant angular spacing and energies of 100 and 200 MeV using a forward planning approach. Dose distributions, dose-volume histograms, coverage (V95% ) and homogeneity (HI98% ) for the planning target volume (PTV), as well as near-maximum doses (D2% ) and mean doses (Dmean ) for organs-at-risk (OAR) were evaluated and compared to clinical IMRT plans. RESULTS: Mean differences of V95% and HI98% of all VHEE plans were within 2% or better of the IMRT reference plans. Glioblastoma plan dose metrics obtained with VHEE configurations of 200 MeV and 3-16 beams were either not significantly different or were significantly improved compared to the clinical IMRT reference plans. All OAR plan dose metrics evaluated for VHEE plans created using 5 beams of 100 MeV were either not significantly different or within 3% on average, except for Dmean for the body, Dmean for the brain, D2% for the brain stem, and D2% for the chiasm, which were significantly increased by 1, 2, 6, and 8 Gy, respectively (however below clinical constraints). Similarly, the dose metrics for lung cancer patients were also either not significantly different or were significantly improved compared to the reference plans for VHEE configurations with 200 MeV and 5 to 16 beams with the exception of D2% and Dmean to the spinal canal (however below clinical constraints). For the lung cancer cases, the VHEE configurations using 100 MeV or only 3 beams resulted in significantly worse dose metrics for some OAR. Differences in dose metrics were, however, strongly patient-specific and similar for some patient cases. CONCLUSIONS: VHEE-based 3D-CRT may deliver conformal treatments to simple, mostly convex target shapes in the brain and the thorax with a limited number of critical adjacent OAR using a limited number of beams (as low as 3 to 7). Using such treatment techniques, a dosimetric plan quality comparable to that of standard-of-care IMRT can be achieved. Hence, from a treatment planning perspective, 3D-conformal UHDR VHEE treatments delivered on time scales of 100 ms represent a promising candidate technique for the clinical transfer of the FLASH effect.


Subject(s)
Glioblastoma , Lung Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Electrons , Radiotherapy Dosage , Radiotherapy, Conformal/methods , Lung Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Carmustine
11.
Adv Exp Med Biol ; 1416: 95-106, 2023.
Article in English | MEDLINE | ID: mdl-37432622

ABSTRACT

Meningiomas are the most common primary intracranial brain tumor, and have a heterogeneous biology and an unmet need for targeted treatment options. Existing treatments for meningiomas are limited to surgery, radiotherapy, or a combination of these depending on clinical and histopathological features. Treatment recommendations for meningioma patients take into consideration radiologic features, tumor size and location, and medical comorbidities, all of which may influence the ability to undergo complete resection. Ultimately, outcomes for meningioma patients are dictated by extent of resection and histopathologic factors, such as World Health Organization (WHO) grade and proliferation index. Radiotherapy is a critical component of meningioma treatment as either a definitive intervention using stereotactic radiosurgery or external beam radiotherapy, or in the adjuvant setting for residual disease or for adverse pathologic factors, such as high WHO grade. In this chapter, we provide a comprehensive review of radiotherapy treatment modalities, therapeutic considerations, radiation planning, and clinical outcomes for meningioma patients.


Subject(s)
Meningeal Neoplasms , Meningioma , Radiosurgery , Humans , Meningioma/radiotherapy , Adjuvants, Immunologic , Neoplasm, Residual , Meningeal Neoplasms/radiotherapy
12.
Acta Oncol ; 62(8): 932-941, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37516978

ABSTRACT

PURPOSE: The purpose of this study was to evaluate three techniques of irradiation of left-sided breast cancer patients, three-dimensional conformal radiotherapy (3D-CRT), hybrid Intensity-Modulated Radiotherapy (h-IMRT), and hybrid Volumetric-Modulated Arc Therapy (h-VMAT, h-ARC), in terms of dose distribution in the planning target volume (PTV) and organs at risk (OARs). The second aim was to estimate the projected relative risk of radiation-induced secondary cancers for hybrid techniques. MATERIALS AND METHODS: Three treatment plans were prepared in 3D-CRT, h-IMRT, and h-VMAT techniques for each of the 40 patients, who underwent CT simulation in deep inspiration breath-hold (DIBH). For hybrid techniques, plans were created by combining 3D-CRT and dynamic fields with an 80%/20% dose ratio for 3D-CRT and IMRT or VMAT. Cumulative dose-volume histograms were used to compare dose distributions within the PTV and OARs (heart, left anterior descending coronary artery [LAD], left and right lung [LL, RL], right breast [RB]). Projected risk ratios for secondary cancers were estimated relative to 3D-CRT using the organ equivalent dose (OED) concept for the Schneider's linear exponential, plateau, and full mechanistic dose-response model. RESULTS: All plans fulfilled the PTV criterium: V95%≥95%. Compared to 3D-CRT, both hybrid techniques showed significantly better target coverage (PTV: V95%>98%, p < 0.001), and the best conformality was achieved by h-ARC plans (CI: 1.18 ± 0.09, p < 0.001). Compared to 3D-CRT and h-ARC, h-IMRT increased the average sum of monitor units (MU) over 129.9% (p < 0.001). H-ARC increased the mean dose of contralateral organs and the LL V5Gy parameter (p < 0.001). Both hybrid techniques significantly reduced the Dmax of the heart by 5 Gy. Compared to h-IMRT, h-ARC increased secondary cancer projected relative risk ratios for LL, RL, and RB by 18, 152, and 81%, respectively. CONCLUSIONS: The results confirmed that both hybrid techniques provide better target quality and OARs sparing than 3D-CRT. Hybrid VMAT delivers less MU compared to hybrid IMRT but may increase the risk of radiation-induced secondary malignancies.


Subject(s)
Breast Neoplasms , Neoplasms, Radiation-Induced , Neoplasms, Second Primary , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Unilateral Breast Neoplasms/radiotherapy , Risk , Breast Neoplasms/radiotherapy , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Neoplasms, Second Primary/etiology , Organs at Risk/radiation effects
13.
Cancer Diagn Progn ; 3(4): 479-483, 2023.
Article in English | MEDLINE | ID: mdl-37405209

ABSTRACT

BACKGROUND/AIM: We compared three-dimensional conformal radiotherapy (3D-CRT) with intensity-modulated radiotherapy (IMRT) for avoiding dosimetric risk factors related to pulmonary complications after neoadjuvant chemoradiotherapy followed by surgery (NACRT-S) for non-small cell lung cancer (NSCLC). PATIENTS AND METHODS: We performed simulations in 11 patients with dosimetric risk factors during their treatment with NACRT-S for NSCLC. Radiation treatment plans were generated using 3D-CRT and IMRT to avoid dosimetric risk factors. Regarding dose-volume histogram (DVH) parameters, we calculated the percentage of lung volume that received more than x Gy (Vx) using 1) the total lung volume minus gross tumor volume (DVHg), 2) the lung volume remaining after surgery (DVHr), and 3) the contralateral lung volume (DVHc). We analyzed the dosimetric differences between 3D-CRT and IMRT. RESULTS: V35g and V40g were significantly lower with IMRT than with 3D-CRT (p=0.001 each); the median V35g and V40g were 16.1% and 14.9% with 3D-CRT versus 12.0% and 9.2% with IMRT, respectively. Overall, 0% and 55% of the patients were able to avoid all dosimetric risk factors with 3D-CRT and IMRT, respectively (p=0.006). Even with IMRT, tumor location and length of the planning target volume (PTV) significantly affected the avoidance of all dosimetric risk factors (p=0.015 and 0.022, respectively). CONCLUSION: IMRT is more useful than 3D-CRT for avoiding dosimetric risk factors in NACRT-S for NSCLC. For further improvements in avoiding these factors, respiratory motion managements to reduce the length of the PTV may be required for patients with middle or lower lobe tumors.

14.
Acta Oncol ; 62(5): 473-479, 2023 May.
Article in English | MEDLINE | ID: mdl-37154167

ABSTRACT

PURPOSE/OBJECTIVES: Proton beam therapy (PBT) may provide a dosimetric advantage in sparing soft tissue and bone for selected patients with extremity soft sarcoma (eSTS). We compared PBT with photons plans generated using intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT). MATERIALS/METHODS: Seventeen patients previously treated with pencil beam scanning PBT were included in this study. Of these patients, 14 treated with pre-operative 50 Gy in 25 fractions were analyzed. IMRT and 3D-CRT plans were created to compare against the original PBT plans. Dose-volume histogram (DVH) indices were evaluated amongst PBT, IMRT, and 3D plans. Kruskal-Wallis rank sum tests were used to get the statistical significance. A p value smaller than .05 was considered to be statistically significant. RESULTS: For the clinical target volume (CTV), D2%, D95%, D98%, Dmin, Dmax, and V50Gy, were assessed. Dmin, D1%, Dmax, Dmean, V1Gy, V5Gy, and V50Gy were evaluated for the adjacent soft tissue. D1%, Dmax, Dmean, and V35-50% were evaluated for bone. All plans met CTV target coverage. The PBT plans delivered less dose to soft tissue and bone. The mean dose to the soft tissue was 2 Gy, 11 Gy, and 13 Gy for PBT, IMRT, and 3D, respectively (p < .001). The mean dose to adjacent bone was 15 Gy, 26 Gy, and 28 Gy for PBT, IMRT, and 3D, respectively (p = .022). CONCLUSION: PBT plans for selected patients with eSTS demonstrated improved sparing of circumferential soft tissue and adjacent bone compared to IMRT and 3D-CRT. Further evaluation will determine if this improved dosimetry correlates with reduced toxicity and improved quality of life.


Subject(s)
Proton Therapy , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Sarcoma , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Quality of Life , Radiotherapy Dosage , Radiotherapy, Conformal/methods , Sarcoma/radiotherapy
15.
Otolaryngol Clin North Am ; 56(2): 247-257, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37030938

ABSTRACT

Multidisciplinary evaluation of early-stage glottic cancer facilitates optimal treatment with either surgery or radiation therapy. Standard of care radiation treatment of early-stage glottic cancer continues to be three-dimensional opposed lateral fields to include the whole larynx. Modern radiation treatment techniques are allowing studies to examine the efficacy and toxicity of altered doses and treatment volumes. Advanced techniques, such as stereotactic body radiation therapy or single-vocal cord irradiation, are not yet considered standard of care for early-stage glottic cancer and should be performed at institutions with clinical trials to ensure adequate expertise and quality assurance.


Subject(s)
Laryngeal Neoplasms , Radiotherapy, Intensity-Modulated , Humans , Laryngeal Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Glottis , Vocal Cords
16.
Discov Oncol ; 14(1): 29, 2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36862205

ABSTRACT

PURPOSE: Synchronous bilateral irradiation of both mammary glands and chest wall is a challenging task due to technical difficulties and limited evidence supporting an optimal technique to improve treatment outcomes. We studied and compared the dosimetry data of three radiotherapy techniques to select the most optimal one. METHODS: We compared three-dimensional conformal radiation treatment (3D CRT), intensity-modulated radiation therapy (IMRT), and volumetric modulated arc therapy (VMAT) during irradiation of synchronous bilateral breast cancer in nine patients followed by examination of dose distribution to the cardiac conduction system (SA node, AV node and Bundle of His), myocardium, lungs, left anterior descending artery (LADA) and right coronary artery (RCA) . RESULTS: VMAT is the most sparing technique for SBBC treatment. Even though doses to the SA node, AV node and Bundle of His were higher with VMAT (Dmean were 3.75 ± 0.62, 2.58 ± 0.83 and 3.03 ± 1.18 Gy respectively) compared with 3D CRT (Dmean were 2.61 ± 0.66, 1.52 ± 0.38 and 1.88 ± 0.70 Gy respectively), this difference is statistically insignificant. Doses to the right and left lung (average Dmean = 12.65 ± 3.20 Gy, V20Gy = 24.12 ± 6.25%), myocardium (Dmean = 5.33 ± 1.51 Gy, V10Gy = 9.80 ± 3.83%, V20Gy = 7.19 ± 3.15%, V25Gy = 6.20 ± 2.93%), and LADA (Dmean = 10.04 ± 4.92 Gy, V20Gy = 18.17 ± 13.24% and V25Gy = 15.41 ± 12.19%) were highest with 3D CRT. The highest  Dmean in the cardiac conduction system (5.30 ± 2.23, 3.15 ± 1.61 and 3.89 ± 1.85 Gy respectively) was observed with IMRT, and a similar effect was noted in RCA (Dmean = 7.48 ± 2.11 Gy). CONCLUSION: VMAT is the optimal and satisfactory radiation therapy technique for sparing organs at risk (OARs). With VMAT, a lower Dmean value was noted in the myocardium, LADA, and lungs. The use of 3D CRT significantly increases the dose of radiation reaching the lungs, myocardium, and LADA, which can subsequently cause cardiovascular and lung complications, but not in the cardiac conduction system.

17.
J Radiat Res ; 64(1): 154-161, 2023 Jan 20.
Article in English | MEDLINE | ID: mdl-36280895

ABSTRACT

This study assessed the efficacy of chemoradiotherapy for squamous cell carcinoma of the anal canal (SCCAC). Patients with T1-4N0-3M0 SCCAC received chemoradiotherapy with 5-fluorouracil (5-FU, 800 mg/m2/day, 96-h infusion) and mitomycin-C (MMC, 10 mg/m2 bolus). Patients treated with 3-dimensional conformal radiotherapy (3D-CRT) or intensity-modulated radiotherapy (IMRT) were administered 36.0 Gy in 20 fractions or 49.5 Gy in 33 fractions for elective nodal irradiation and 59.4 Gy in 33 fractions for primary tumor and metastatic nodal irradiation. The sample size was considered sufficient to estimate 95% confidence intervals (CIs) for the true 2-year disease-free survival (DFS) within a width of +15% when the expected true 2-year DFS was 70%. The primary endpoint was 2-year DFS. The secondary endpoints were 2-year overall survival (OS), locoregional control (LC), colostomy-free survival (CFS) and adverse events. Thirty-one patients were enrolled between January 2014 and July 2019. The median follow-up was 33.3 months (range, 16.2-65.8 months). Among the 31 patients, 13%, 32%, 16% and 39% had stage I, II, IIIA and IIIB disease, respectively. Thirty patients were treated with IMRT. Complete response (CR) was achieved in 27 patients. The 2-year DFS, OS, LC and CFS rates were 77.4% (95% CI, 58.4-88.5%), 93.5% (95% CI, 76.6-98.3%), 83.9% (95% CI, 65.5-92.9%) and 80.6% (95% CI, 61.9-90.8%), respectively. One patient experienced grade 3 late adverse events; however, no grade ≥ 4 late adverse events occurred. Good DFS with a low rate of late adverse events was observed. Chemoradiotherapy with 5-FU and MMC was effective for SCCAC.


Subject(s)
Anus Neoplasms , Carcinoma, Squamous Cell , Chemoradiotherapy , Humans , Anal Canal/pathology , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Carcinoma, Squamous Cell/therapy , Chemoradiotherapy/adverse effects , Fluorouracil/therapeutic use , Mitomycin/therapeutic use , Radiotherapy, Intensity-Modulated/methods , Anus Neoplasms/therapy
18.
Cancers (Basel) ; 14(24)2022 Dec 11.
Article in English | MEDLINE | ID: mdl-36551582

ABSTRACT

(1) Aim: This study was conducted to radiobiologically compare radiotherapy plans for gastric cancer with a newly developed software tool. (2) Methods: Treatment planning was performed on two computational phantoms simulating adult male and female patients. Three-dimensional conformal radiotherapy (3D-CRT), intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans for gastric cancer were generated with three-photon beam energies. The equivalent uniform dose (EUD), tumor control probability (TCP) of the target and normal tissue control probability (NTCP) of eight different critical organs were calculated. A new software was employed for these calculations using the EUD-based model and dose-volume-histogram data. (3) Results: The IMRT and VMAT plan led to TCPs of 51.3-51.5%, whereas 3D-CRT gave values up to 50.2%. The intensity-modulated techniques resulted in NTCPs of (5.3 × 10-6-3.3 × 10-1)%. The corresponding NTCPs from 3D-CRT were (3.4 × 10-7-7.4 × 10-1)%. The above biological indices were automatically calculated in less than 40 s with the software. (4) Conclusions: The direct and quick radiobiological evaluation of radiotherapy plans is feasible using the new software tool. The IMRT and VMAT reduced the probability of the appearance of late effects in most of the surrounding critical organs and slightly increased the TCP compared to 3D-CRT.

19.
Healthcare (Basel) ; 10(12)2022 Dec 02.
Article in English | MEDLINE | ID: mdl-36553955

ABSTRACT

It is very important to use effective parameters in the treatment plan of breast cancer patients in TomoDirect (TD)-three-dimensional conformal radiation therapy (TD-3DCRT). The objective of this study was to compare the radiation treatment plans to the parameters (jaw width and jaw mode) of TD-3DCRT for left-breast cancer. This study was conducted using the phantom, the jaw mode (fixed and dynamic) and field width (2.5 cm and 5.0 cm) were controlled to compare the TD-3DCRT treatment plans. There was small difference in the conformity index (CI) and homogeneity index (HI) values for target according to the jaw mode for each field width. As a result of observation in terms of dose, treatment time and unnecessary damage to surrounding normal organs could be minimized when dynamic jaw with a field width of 5.0 cm was used. In conclusion, we verified that the use of dynamic jaws and 5.0 cm field width was effective in left-breast cancer radiotherapy plan using TD-3DCRT.

20.
J Clin Med ; 11(19)2022 Oct 06.
Article in English | MEDLINE | ID: mdl-36233771

ABSTRACT

External auditory canal (EAC) cancer is a rare disease for which there are no adequate evidence-based treatment strategies. Radiotherapy is often used as the initial treatment to preserve the organ. This study aimed to elucidate the efficacy of radiotherapy for EAC squamous cell carcinoma (SCC). Patients with T1 disease were treated with radiotherapy alone. Patients with T2-4 disease were treated with chemoradiotherapy. The median follow-up period was 30.4 months. The 3-year local control (LC) rate for all patients was 51%, the disease-free survival (DFS) rate was 44%, and the overall survival (OS) rate was 73%. For T1-3 disease, the 3-year LC rate was 74%, DFS was 62%, and OS was 89%. However, for T4 disease, the 3-year LC rate was 17%, DFS was 17%, and OS was 50%. In a univariate analysis, only the T-category was a significant factor for LC and DFS (p = 0.006 and 0.02, respectively). All local recurrences were within the high-dose irradiated area. The results of this study suggest chemoradiotherapy can be an alternative to a combination of surgery and postoperative radiation for T1-3 SCC of the EAC. However, the efficacy of chemoradiotherapy in T4 cases was inadequate.

SELECTION OF CITATIONS
SEARCH DETAIL
...