Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Rev. Pesqui. Fisioter ; 11(4): 774-782, 20210802. tab, ilus
Article in English, Portuguese | LILACS | ID: biblio-1349142

ABSTRACT

INTRODUÇÃO: Disfunções temporomandibulares (DTM) são distúrbios na ATM, sendo de origem muscular, articular ou mista, e com íntima relação com alterações posturais. Instrumentos de diagnóstico apresentam lacunas quanto à aplicação clínica e não associam à postura. OBJETIVO: Validar o Teste Avaliativo de DTM (TAvDTM) quanto à acurácia diagnóstica e reprodutibilidade. MATERIAIS E MÉTODOS: Estudo de acurácia diagnóstica com indivíduos entre 18 e 59 anos avaliados pelo Índice Anamnésico de Fonseca (IAF), questionário sociodemográfico e TAvDTM, este último realizado por três examinadores diferentes e treinados. O resultado da categorização do diagnóstico do IAF foi comparado com o resultado do TAvDTM. Para acurácia diagnóstica utilizou-se teste Qui-Quadrado. Valores Preditivos Positivos (VPP) e Negativos (VPN) foram determinados. A reprodutibilidade entre os três examinadores foi feita por meio do Kappa de Cohen, para análise 2x2 e de Fleiss. Todos os testes com significância de 5%. RESULTADOS: Dos 10 participantes avaliados, o IAF identificou 8 com diagnóstico de DTM, enquanto o TAvDTM verificou 9 participantes com presença desta disfunção. A sensibilidade foi de 100%, especificidade de 50%, VPP de 88% e VPN de 50%. O Kappa de Fleiss evidenciou confiabilidade razoável (K = 0,26 [IC 95%: -0,099 ­ 0,617]; p>0,05). O Kappa de Cohen mostrou reprodutibilidade insignificante entre os avaliadores 1 e 2 (K=-0,11; p>0,05; discordância=80%), e 1 e 3 (K= -0,11; p>0,05; discordância=80%), reprodutibilidade perfeita entre os avaliadores 2 e 3 (K=1,00; p<0,05; concordância=100%). CONCLUSÃO: O TAvDTM apresenta alta sensibilidade e baixa especificidade, porém com baixa capacidade de reprodução até o presente momento.


INTRODUCTION: Temporomandibular disorders are TMJ disorders of muscular, articular, or mixed origin and closely related to postural alterations. Diagnostic tools have gaps regarding clinical application and do not associate posture. OBJECTIVE: Validate the TMD Assessment Test (TMDAsT) regarding its diagnostic accuracy and reproducibility. MATERIALS AND METHODS: Diagnostic accuracy study with individuals between 18 and 59 years old evaluated by the Fonseca Assessment Index (FAI), sociodemographic questionnaire, and TMDAsT, the latter performed by three different trained examiners. The result of FAI diagnosis categorization was compared with the result of TMDAsT. A Chi-square test was used for diagnostic accuracy. Positive predictive values (PPV) and negative predictive values (NPV) were determined. The Kappa of Fleiss did the reproducibility between three examiners. Cohen's Kappa, for 2x2 analysis. All tests with 5% significance. RESULTS: Of the 10 participants assessed, FAI identified 8 participants with a TMD diagnosis while the TMDAsT verified 9 participants with this dysfunction. Sensitivity was 100%, specificity 50%, PPV 88% and NPV 50%. Fleiss' Kappa showed reasonable reliability (K = 0.26 [95% CI: -0.099 - 0.617]; p>0.05). Cohen's Kappa showed insignificant reproducibility between observers 1 and 2 (K=-0.11; p>0.05; discordance=80%), and 1 and 3 (K= -0.11; p>0.05; discordance=80%), perfect reproducibility between observers 2 and 3 (K=1.00; p<0.05; concordance=100%). CONCLUSION: TMDAsT presents high sensitivity and low specificity but with low reproducibility until the present moment.


Subject(s)
Temporomandibular Joint Disorders , Predictive Value of Tests , Surveys and Questionnaires
2.
Rev. bras. anal. clin ; 53(2): 155-162, 20210630. ilus, tab
Article in Portuguese | LILACS | ID: biblio-1349033

ABSTRACT

A rápida caracterização do genoma do Coronavírus-2 (SARS-CoV-2) mobilizou a produção em larga escala de métodos diagnósticos. Agências reguladoras aprovaram condicionalmente o uso emergencial de vários deles. Na emergência de saúde, inúmeros exames foram utilizados sem o devido conhecimento da qualidade. O objetivo desta revisão narrativa foi destacar a acurácia diagnóstica dos métodos sorológicos de diagnóstico da COVID-19 em termos de sensibilidade e especificidade clínicas. A sensibilidade diagnóstica variou até 50% entre estudos, enquanto a especificidade apresentou menor variação; no entanto, uma mesma marca chegou a apresentar variação de 32%. Considerando-se o critério de especificidade >95% definido pelo FDA, apenas uma marca de ensaio para detecção de IgG e outra para IgM atingiram a meta. Para a detecção de IgA e de IgA+IgM, as únicas marcas apresentadas não atingiram a meta. Entre as cinco marcas para detecção de IgM+IgG, apenas uma não atingiu a especificidade clínica. Para Ig total, as duas marcas apresentaram especificidade aceitável. Considerando-se o critério de sensibilidade clínica >90%, apenas 6 dos 25 estudos com diferentes marcas de ensaios para detecção de IgG apresentam o desempenho especificado; destas, nenhuma é brasileira. Nenhuma das marcas de ensaios para detecção de IgM e IgM+IgG apresentaram o desempenho especificado. A única marca apresentada para detecção de IgA+IgM atingiu a meta especificada pelo FDA. Os ensaios imunocromatográficos apresentaram menor sensibilidade. Os resultados demonstraram o pobre valor diagnóstico dos imunoensaios, mas com potencial para estudos soroepidemiológicos. Mais estudos de validação analítica e acurácia diagnóstica de ensaios são essenciais, principalmente dos reagentes nacionais.


The rapid characterization of the coronavirus-2 (SARS-CoV-2) genome has mobilized the large-scale production of diagnostic methods. Regulatory agencies have conditionally approved the emergency use of several of them. In the health emergency, numerous tests were used without proper knowledge of quality. The aim of this narrative review was to highlight the diagnostic accuracy of serological methods for the diagnosis of COVID-19 in terms of clinical sensitivity and specificity. The diagnostic sensitivity varied up to 50% between studies, while the specificity showed less variation, however, the same brand even showed a variation of 32%. Considering the >95% specificity criteria defined by the FDA, only one test brand for detection of IgG and one for IgM reached the goal. For the detection of IgA and IgA+IgM, the only brands presented did not reach the goal. Among the 5 marks for detecting IgM+IgG, only one did not reach clinical specificity. For total Ig, both brands had acceptable specificity. Considering the criterion of clinical sensitivity >90%, only 6 of the 25 studies with different brands of assays for detection of IgG present the specified performance, none of which are Brazilian. None of the brands of assays for detecting IgM and IgM+IgG showed the specified performance. The only brand presented for detection of IgA+IgM reached the target specified by the FDA. Immunochromatographic assays showed lower sensitivity. The results demonstrated the poor diagnostic value of immunoassays, but with potential for seroepidemiological studies. More studies on analytical validation and diagnostic accuracy of assays are essential, especially for national reagents.


Subject(s)
Immunoglobulin G , Immunoglobulin M , Serologic Tests , Data Accuracy , SARS-CoV-2 , COVID-19/diagnosis
3.
Braz. j. otorhinolaryngol. (Impr.) ; 85(3): 275-281, May-June 2019. tab
Article in English | LILACS | ID: biblio-1011628

ABSTRACT

Abstract Introduction: Fine needle aspiration biopsy is a valuable tool in preoperative evaluation of head and neck tumors. However, its accuracy in management of salivary gland tumors is debatable. Objective: We aimed to investigate the efficacy and the accuracy of fine needle aspiration biopsy in parotid gland tumors. Methods: Patients who underwent parotidectomy between January 2008 and June 2017 due to parotid gland tumor were examined retrospectively. Patients with both preoperative fine needle aspiration biopsy and postoperative surgical pathologies were included. Preoperative fine needle aspiration biopsy was categorized as benign, malignant or suspicious for malignancy. Surgical pathology was grouped as benign or malignant. Surgical pathology was compared with fine needle aspiration biopsy, and sensitivity, specificity, accuracy and agreement between both tests were investigated. Results: 217 cases were evaluated and 23 cases were excluded because the fine needle aspiration biopsy diagnosis was non-diagnostic or unavailable. 194 cases were included. The mean age of the patients was 47.5 ± 15.88 (7-82). There were 157 benign, 37 malignant cases in fine needle aspiration biopsy, 165 benign and 29 malignant cases in surgical pathology. The most common benign tumor was pleomorphic adenoma (43.3%), and malignant tumor was mucoepidermoid carcinoma (4.13%). The diagnostic accuracy for fine needle aspiration biopsy when detecting malignancy was 86.52%. Sensitivity and specificity were 68.96% and 89.63% respectively. Positive predictive value was 54.05% and negative predictive value was 94.23%. There was moderate agreement between fine needle aspiration biopsy and surgical pathology (κ = 0.52). The sensitivity was 54.54% in tumors less than 2 cm while 77.77% in larger tumors. In tumors extending to the deep lobe, sensitivity was 80%. Conclusion: Fine needle aspiration biopsy is an important diagnostic tool for evaluating parotid gland tumors. It is more accurate in detecting benign tumors. In tumors greater than 2 cm and extending to the deep lobe, the sensitivity of fine needle aspiration biopsy is high. The use of fine needle aspiration biopsy in conjunction with clinical and radiological evaluation may help to reduce false positive and false negative results.


Resumo Introdução: A punção aspirativa com agulha fina é uma ferramenta valiosa na avaliação pré-operatória de tumores de cabeça e pescoço. No entanto, sua precisão no tratamento de tumores de glândulas salivares é discutível. Objetivo: Nosso objetivo foi investigar a eficácia e precisão da punção aspirativa com agulha fina nos tumores da glândula parótida. Método: Pacientes submetidos à parotidectomia entre janeiro de 2008 e junho de 2017 por tumor de glândula parótida foram examinados retrospectivamente. Foram incluídos pacientes com punção aspirativa com agulha fina pré-operatória e histopatologia cirúrgica pós-operatória. A punção aspirativa com agulha fina pré-operatória foi categorizada como benigna, maligna ou com suspeita de malignidade. O histopatológico cirúrgico foi agrupado como benigno ou maligno. Os exames histopatológicos foram comparados com a punção aspirativa com agulha fina e a sensibilidade, especificidade, acurácia e concordância entre os dois testes foram investigadas. Resultados: Foram avaliados 217 casos e excluídos 23 porque o diagnóstico da punção aspirativa com agulha fina não foi conclusivo ou estava indisponível. Portanto, foram incluídos 194 casos. A média de idade dos pacientes foi de 47,5 ± 15,88 (7-82). Havia 157 casos benignos, 37 malignos na punção aspirativa com agulha fina e 165 benignos e 29 malignos na histopatologia. O tumor benigno mais comum foi o adenoma pleomórfico (43,3%) e o tumor maligno mais comum foi o carcinoma mucoepidermoide (4,13%). A acurácia diagnóstica da punção aspirativa com agulha fina na detecção de malignidade foi de 86,52%. A sensibilidade e especificidade foram de 68,96% e 89,63%, respectivamente. O valor preditivo positivo foi de 54,05% e o valor preditivo negativo foi de 94,23%. Houve concordância moderada entre a punção aspirativa com agulha fina e histopatológico (κ = 0,52). A sensibilidade foi 54,54% em tumores menores do que 2 cm e 77,77% em tumores maiores. Nos tumores que se estendiam até o lobo profundo, a sensibilidade foi de 80%. Conclusão: A punção aspirativa com agulha fina é uma importante ferramenta diagnóstica na avaliação dos tumores da glândula parótida. É mais precisa na detecção de tumores benignos. Em tumores maiores do que 2 cm que se estendem até o lobo profundo, a sensibilidade da punção aspirativa com agulha fina é alta. O uso dessa ferramenta em conjunto com a avaliação clínica e radiológica pode ajudar a reduzir os resultados falso-positivos e falso-negativos.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Parotid Neoplasms/pathology , Biopsy, Fine-Needle , Parotid Neoplasms/surgery , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
4.
Braz J Otorhinolaryngol ; 85(3): 275-281, 2019.
Article in English | MEDLINE | ID: mdl-29936215

ABSTRACT

INTRODUCTION: Fine needle aspiration biopsy is a valuable tool in preoperative evaluation of head and neck tumors. However, its accuracy in management of salivary gland tumors is debatable. OBJECTIVE: We aimed to investigate the efficacy and the accuracy of fine needle aspiration biopsy in parotid gland tumors. METHODS: Patients who underwent parotidectomy between January 2008 and June 2017 due to parotid gland tumor were examined retrospectively. Patients with both preoperative fine needle aspiration biopsy and postoperative surgical pathologies were included. Preoperative fine needle aspiration biopsy was categorized as benign, malignant or suspicious for malignancy. Surgical pathology was grouped as benign or malignant. Surgical pathology was compared with fine needle aspiration biopsy, and sensitivity, specificity, accuracy and agreement between both tests were investigated. RESULTS: 217 cases were evaluated and 23 cases were excluded because the fine needle aspiration biopsy diagnosis was non-diagnostic or unavailable. 194 cases were included. The mean age of the patients was 47.5±15.88 (7-82). There were 157 benign, 37 malignant cases in fine needle aspiration biopsy, 165 benign and 29 malignant cases in surgical pathology. The most common benign tumor was pleomorphic adenoma (43.3%), and malignant tumor was mucoepidermoid carcinoma (4.13%). The diagnostic accuracy for fine needle aspiration biopsy when detecting malignancy was 86.52%. Sensitivity and specificity were 68.96% and 89.63% respectively. Positive predictive value was 54.05% and negative predictive value was 94.23%. There was moderate agreement between fine needle aspiration biopsy and surgical pathology (κ=0.52). The sensitivity was 54.54% in tumors less than 2cm while 77.77% in larger tumors. In tumors extending to the deep lobe, sensitivity was 80%. CONCLUSION: Fine needle aspiration biopsy is an important diagnostic tool for evaluating parotid gland tumors. It is more accurate in detecting benign tumors. In tumors greater than 2cm and extending to the deep lobe, the sensitivity of fine needle aspiration biopsy is high. The use of fine needle aspiration biopsy in conjunction with clinical and radiological evaluation may help to reduce false positive and false negative results.


Subject(s)
Biopsy, Fine-Needle , Parotid Neoplasms/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Child , Female , Humans , Male , Middle Aged , Parotid Neoplasms/surgery , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity , Young Adult
5.
Int J Nurs Knowl ; 29(2): 124-132, 2018 04.
Article in English, Portuguese | MEDLINE | ID: mdl-27321209

ABSTRACT

PURPOSE: To design and test educational software to improve nursing students' diagnostic reasoning through NANDA-I-based clinical scenarios. METHODS: A mixed method approach was used and included content validation by a panel of 13 experts and prototype testing by a sample of 56 students. FINDINGS: Experts' suggestions included writing adjustments, new response options, and replacement of clinical information on the scenarios. Percentages of students' correct answers were 65.7%, 62.2%, and 60.5% for related factors, defining characteristics, and nursing diagnoses, respectively. CONCLUSION: Full development of this software shows strong potential for enhancing students' diagnostic reasoning. IMPLICATIONS FOR NURSING PRACTICE: New graduates may be able to apply diagnostic reasoning more rapidly by exercising their diagnostic skills within this software.


OBJETIVO: Desenvolver e testar um protótipo de software educativo para melhorar o raciocínio diagnóstico de estudantes de enfermagem. MÉTODOS: Uma abordagem mista foi utilizada e incluiu validação de conteúdo por 13 experts e testagem do protótipo por 56 estudantes. RESULTADOS: Sugestões dos experts incluíram ajustes na escrita, inclusão de novas opções de resposta e substituição de dados clínicos nos cenários. Os percentuais de respostas corretas dos estudantes foram 65,7%, 62,2% e 60,5% para fatores relacionados, características definidoras e diagnósticos de enfermagem respectivamente. CONCLUSÃO: O desenvolvimento deste software tem um forte potencial para melhorar o raciocínio diagnóstico de estudantes. IMPLICAÇÕES PARA A PRÁTICA EM ENFERMAGEM: Através deste software, enfermeiros poderão ser capazes de exercitar o raciocínio diagnóstico e aplicá-lo mais rapidamente.


Subject(s)
Software Design , Students, Nursing/psychology , Thinking , Adult , Humans , Problem Solving , Surveys and Questionnaires , Task Performance and Analysis
6.
Bauru; s.n; 2016. 126 p. ilus, graf, tab.
Thesis in English | LILACS, BBO - Dentistry | ID: biblio-881298

ABSTRACT

Orofacial pain conditions can be classified into somatic, visceral or neuropathic pain. Somatic pain is triggered by a noxious stimulus generally inducted by peripheral traumas, such as dental implants surgeries (IMP). Visceral pain initiates within internal body tissues and is normally triggered by inflammation, as in inflammatory toothaches (IT). The third condition is neuropathic pain, which results from persistent injury to the peripheral nerve as in Atypical Odontalgia (AO). The aims of this study were: 1- to investigate somatosensory abnormalities, using mechanical, painful, and electrical quantitative sensory testing (QST), in somatic (IMP patients), visceral (IT) and neuropathic pain (AO); 2- to quantify how accurately QST discriminates an IT or AO diagnosis; and 3- to investigate the influence implant surgeries or pulpectomy may have on somatosensory system and sensory nerve fibers. Sixty subjects were divided in three groups: IMP (n = 20), IT (n = 20) and AO group (n = 20). A sequence of five QSTs and the Conditioned Pain Modulation Test (CPM) were performed one month and three months after dental implant surgery (IMP group) or pulpectomy (IT group). AO group was evaluated only at baseline. QST comprehended Mechanical Detection Threshold (MDT), Mechanical Pain Threshold (MPT), Dynamical Mechanical Allodynia (DMA), Current Perception Threshold (CPT) for A-beta (frequency of 2000Hz), A-delta (250Hz) and C fibers (5Hz) and Temporal Summation Test (TS). "Z" score transformation were applied to the data, and within and between groups were statistically analyzed using two-way ANOVA. In addition, the receiver operating characteristic curve analysis, diagnostic accuracy, sensitivity, specificity, likelihood ratios, and diagnostic odds ratio of QSTs were calculated (α = 5%). The findings of this study proved that: 1- loss of function for touch threshold and electrical threshold of C fibers is present in inflammatory toothache; 2- allodynia, hyperalgesia, gain of function for touch and pain thresholds and impaired pain modulation is detected in atypical odontalgia; 3- some QSTs may be used as complementary tests in the differential diagnosis of atypical odontalgia and inflammatory toothache with strong accuracy; 4- the most accurate QSTs for differential diagnosis between subjects with AO and IT were MDT, MPT and DMA where touch threshold forces > 1 g/mm2 and pain threshold forces > 10g/mm2 can be used to accurately discriminate AO from IT; and 5- no somatosensory modification is found after implant surgery and reduced electrical threshold in C fiber is found for patients with inflammatory toothache after 3 months of pulpectomy.(AU)


As dores orofaciais podem ser classificadas em dores somáticas, viscerais ou neuropáticas. A dor somática está relacionada a um estímulo nocivo evidente, geralmente associada a um trauma periférico, como por exemplo, nas cirurgias de implantes (IMP). As dores viscerais têm origem dentro dos órgãos e cavidades internas do corpo e são ativadas pela inflamação, como no exemplo da dor de dente do tipo Pulpite Aguda (PA). A terceira condição é a dor neuropática, que resulta de uma lesão persistente ao nervo periférico, como ocorre na Odontalgia Atípica (OA). Os objetivos deste estudo foram: 1- avaliar as alterações somatossensoriais, por meio do uso de Testes Sensoriais Quantitativos (TSQ) mecânicos, dolorosos e elétricos em dores somáticas (pacientes IMP), viscerais (PA) e neuropáticas (OA); 2- quantificar a acurácia dos TSQs na descriminação diagnóstica de uma PA ou OA; e 3- investigar alterações somatossensoriais e nas fibras nervosas sensoriais após cirurgia de instalação de implantes dentários ou pulpectomia. Sessenta sujeitos foram divididos em três grupos: IMP (n = 20), PA (n = 20) e OA (n = 20). Uma sequência de cinco TSQs e o teste de Controle da Modulação da Dor (CMD) foram realizados um mês e três meses após cirurgia de implantes (grupo IMP) ou pulpectomia (grupo PA). No grupo OA, os testes foram realizados somente uma vez no início do estudo. Os TSQs englobaram o Limiar de Detecção Mecânica (LDM), Limiar de Dor Mecânica (LDoM), Alodinia Mecânica Dinâmica (AMD), Limiar de Percepção de Corrente (LPC) para fibras A-beta (frequência de 2000Hz), A-delta (250Hz) e C (5 Hz), e o teste de Somação Temporal (ST). A transformação em escores de "Z" foi aplicada aos dados, e diferenças intra e inter-grupos foram analisadas usando ANOVA de medidas repetidas. Ainda, a acurácia diagnóstica dos TSQs foi medida por meio da sensibilidade, especificidade, razão de verossimilhança e razão de chances para diagnóstico (α = 5%). Os resultados deste estudo mostraram que: 1- perda da função em limiar táctil e limiar elétrico de fibras C está presente na Pulpite Aguda; 2- alodinia, hiperalgesia, ganho de função nos limiares de tato e de dor, e modulação da dor prejudicada são encontrados em pacientes com odontalgia atípica; 3- alguns TSQs podem ser usados como testes diagnósticos complementares ao diagnóstico diferencial entre PA e OA; 4- os TSQs com maior acurácia para o diagnóstico diferencial entre indivíduos com PA e OA foram LDM LDoM e AMD, onde uma força maior que 1 g/mm2 para limiar de tato e maior que 10 g/mm2 para limiar de dor podem ser usados com precisão; e 5- nenhuma alteração somatossensorial é encontrada após cirurgia de implantes e uma redução no limiar elétrico em fibras C é encontrado em pacientes com PA após 3 meses da pulpectomia.(AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Facial Neuralgia/physiopathology , Facial Pain/diagnosis , Facial Pain/etiology , Facial Pain/physiopathology , Hyperalgesia/physiopathology , Pain Measurement/methods , Visceral Pain/physiopathology , Analysis of Variance , Case-Control Studies , Diagnosis, Differential , Pain Threshold/physiology , Reference Values , ROC Curve
7.
J. bras. patol. med. lab ; 49(4): 288-293, Aug. 2013. ilus, tab
Article in English | LILACS | ID: lil-697105

ABSTRACT

INTRODUCTION: Despite the fact that the fine needle aspiration biopsy (FNA) is commonly used in the initial evaluation and distinction of benign and malignant lesions of thyroid nodules, it may yield variable results, inasmuch as it is contingent on the pathologist's analysis and expertise in collecting appropriate samples. OBJECTIVE: To check the diagnostic accuracy between FNA and pathological examination of thyroid nodules, both performed in a diagnostic pathology service. METHODS: Retrospective study carried out in a diagnostic pathology service in Chapecó, Santa Catarina, Brazil. All patients who underwent FNA and pathological examination in the period from January 1st 2005 to December 31 2010 were included in this study. RESULTS: 1,172 FNA were conducted during this period and 265 patients underwent both FNA and pathological examination. Most patients were female (85%), with mean age 47.75 years (standard deviation [SD] = 14.93 years). Cytopathological examinations yielded the following results: benignity (43.77 %), suspected malignancy (23.77%), follicular neoplasm (5.28%), atypical follicular lesion of undetermined significance (1.51%) and unsatisfactory sample (1.51%). In the pathological examination, the most predominant diagnoses were colloid goiter (38.87%), follicular adenoma (22.64%) and classic papillary carcinoma (18.87%). In satisfactory samples (n = 261), the following results were obtained: diagnostic accuracy (89.66%), sensitivity (82.14%), specificity (93.22%), negative predictive value (91.67%) and positive predictive value (75.19%). CONCLUSION: We concluded that FNA provides a good predictive value for benign thyroid, constituting a reliable and effective tool for diagnosis and surgical indication.


INTRODUÇÃO: A punção aspirativa por agulha fina (PAAF), apesar de ser utilizada na avaliação inicial e na distinção de lesões benignas e malignas de nódulos da tireoide, pode promover resultados variados, uma vez que depende da análise do patologista e da habilidade em coletar amostras adequadas. OBJETIVO: Verificar a acurácia diagnóstica entre a PAAF e o exame anatomopatológico de nódulos tireoidianos, realizados em um serviço de diagnósticos de patologia. MÉTODOS: Estudo retrospectivo realizado em um serviço de diagnósticos de patologia em Chapecó, Santa Catarina, Brasil. Participaram do estudo todos os pacientes que realizaram PAAF e exame anatomopatológico no período de 1º de janeiro de 2005 a 31 de dezembro de 2010. RESULTADOS: Foram realizadas 1.172 punções no referido período, sendo avaliados, ao total, 265 pacientes que realizaram tanto a PAAF quanto o exame anatomopatológico. Houve predominância de mulheres (85%), com uma média de 47,75 anos de idade (desvio padrão [DP] = 14,93 anos). Nos exames citopatológicos, diagnosticou-se benignidade em 43,77% dos casos, suspeita de malignidade em 23,77%, neoplasia folicular em 25,28%, lesão atípica de significado indeterminado em 1,51% e amostra insatisfatória em 1,51%. No anatomopatológico, os diagnósticos que predominaram foram bócio coloide (38,87%), adenoma folicular (22,64%) e carcinoma papilar clássico (18,87%). Nas amostras satisfatórias (n = 261), verificou-se que a acurácia diagnóstica foi de 89,66%, sensibilidade de 82,14%, especificidade de 93,22%, valor preditivo negativo de 91,67% e valor preditivo positivo de 75,19%. CONCLUSÃO: Conclui-se que a PAAF proporciona boa predição de patologia benigna da tireoide, sendo um meio confiável e efetivo para diagnóstico e indicação cirúrgica.

SELECTION OF CITATIONS
SEARCH DETAIL
...