Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 231
Filter
1.
Environ Sci Technol ; 58(24): 10524-10535, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38832650

ABSTRACT

In the context of escalating urban heat events due to climate change, air conditioning (AC) has become a critical factor in maintaining indoor thermal comfort. Yet the usage of AC can also exacerbate outdoor heat stress and burden the electricity system, and there is little scientific knowledge regarding how to balance these conflicting goals. To address this issue, we established a coupled modeling approach, integrating the Weather Research and Forecasting model with the building energy model (WRF_BEP + BEM), and designed multiple AC usage scenarios. We selected Chongqing, China's fourth-largest megacity, as our study area due to its significant socioeconomic importance, the severity of extreme heat events, and the uniqueness of its energy infrastructure. Our analysis reveals that AC systems can substantially reduce indoor temperatures by up to 18 °C; however, it also identifies substantial nighttime warming (2-2.5 °C) and a decline in thermal comfort. Particularly for high-density neighborhoods, when we increase 2 °C indoors, the outdoor temperature can be alleviated by up to 1 °C. Besides, despite the limited capacity to regulate peak electricity demand, we identified that reducing the spatial cooled fraction, increasing targeted indoor temperature by 2 °C, and implementing temporal AC schedules can effectively lower energy consumption in high-density neighborhoods, especially the reduction of spatial cooled fraction (up to 50%). Considering the substantial demand for cooling energy, it is imperative to carefully assess the adequacy and continuity of backup energy sources. The study underscores the urgency of reassessing energy resilience and advocates for addressing the thermal equity between indoor and outdoor environments, contributing to the development of a sustainable and just urban climate strategy in an era of intensifying heat events.


Subject(s)
Air Conditioning , Climate Change , China , Temperature , Models, Theoretical
2.
J Hazard Mater ; 472: 134459, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38691999

ABSTRACT

Bioaerosols are widely distributed in urban air and can be transmitted across the atmosphere, biosphere, and anthroposphere, resulting in infectious diseases. Automobile air conditioning (AAC) filters can trap airborne microbes. In this study, AAC filters were used to investigate the abundance and pathogenicity of airborne microorganisms in typical Chinese and European cities. Culturable bacteria and fungi concentrations were determined using microbial culturing. High-throughput sequencing was employed to analyze microbial community structures. The levels of culturable bioaerosols in Chinese and European cities exhibited disparities (Analysis of Variance, P < 0.01). The most dominant pathogenic bacteria and fungi were similar in Chinese (Mycobacterium: 18.2-18.9 %; Cladosporium: 23.0-30.2 %) and European cities (Mycobacterium: 15.4-37.7 %; Cladosporium: 18.1-29.3 %). Bartonella, Bordetella, Alternaria, and Aspergillus were also widely identified. BugBase analysis showed that microbiomes in China exhibited higher abundances of mobile genetic elements (MGEs) and biofilm formation capacity than those in Europe, indicating higher health risks. Through co-occurrence network analysis, heavy metals such as zinc were found to correlate with microorganism abundance; most bacteria were inversely associated, while fungi exhibited greater tolerance, indicating that heavy metals affect the growth and reproduction of bioaerosol microorganisms. This study elucidates the influence of social and environmental factors on shaping microbial community structures, offering practical insights for preventing and controlling regional bioaerosol pollution.


Subject(s)
Air Conditioning , Air Microbiology , Automobiles , Bacteria , Cities , Fungi , China , Europe , Bacteria/genetics , Bacteria/isolation & purification , Fungi/isolation & purification , Fungi/pathogenicity , Fungi/genetics , Air Filters/microbiology , Air Pollutants/analysis , Microbiota , Environmental Monitoring
3.
Article in English | MEDLINE | ID: mdl-38743058

ABSTRACT

Two strictly aerobic and rod-shaped bacteria, labelled as DB1703T and DB2414ST, were obtained from an automobile air conditioning system. Strain DB1703T was Gram-stain-negative, while strain DB2414ST was Gram-stain-positive. Both strains were catalase-positive and oxidase-negative. Strains DB1703T and DB2414ST were able to grow at 18-42 °C. Strain DB1703T grew within a NaCl range of 0-3 % and a pH range of 6.0-8.0; while strain DB2414ST grew at 0-1 % and pH 6.5-8.5. The phylogenetic and 16S rRNA gene sequence analysis indicated that strains DB1703T and DB2414ST belonged to the genera Enterovirga and Knoellia, respectively. Strain DB1703T showed the closest phylogenetic similarity to Enterovirga rhinocerotis YIM 100770T (94.8 %), whereas strain DB2414ST was most closely related to Knoellia remsis ATCC BAA-1496T (97.7 %). The genome sizes of strains DB1703T and DB2414ST were 4 652 148 and 4 282 418 bp, respectively, with DNA G+C contents of 68.8 and 70.5 mol%, respectively. Chemotaxonomic data showed Q-10 as the sole ubiquinone in DB1703T and ML-8 (H4) in DB2414ST. The predominant cellular fatty acid in DB1703T was summed feature 8 (C18 : 1 ω7c and/or C18 : 1 ω6c), whereas iso-C16 : 0, C17 : 1 ω8c, and iso-C15 : 0 were dominant in DB2414ST. Overall, the polyphasic taxonomic comparisons showed that strains DB1703T and DB2414ST were distinct from their closest taxa and represent novel species within the genera Enterovirga and Knoellia, respectively. Accordingly, we propose the names Enterovirga aerilata sp. nov., with the type strain DB1703T (=KCTC 72724T=NBRC 114759T), and Knoellia koreensis sp. nov., with the type strain DB2414ST (=KCTC 49355T=NBRC 114620T).


Subject(s)
Air Conditioning , Automobiles , Bacterial Typing Techniques , Base Composition , DNA, Bacterial , Fatty Acids , Phylogeny , RNA, Ribosomal, 16S , Sequence Analysis, DNA , Ubiquinone , Fatty Acids/analysis , RNA, Ribosomal, 16S/genetics , DNA, Bacterial/genetics , Republic of Korea
4.
Sci Rep ; 14(1): 9053, 2024 04 20.
Article in English | MEDLINE | ID: mdl-38643255

ABSTRACT

The nose of the mammals is responsible for filtering, humidifying, and heating the air before entering the lower respiratory tract. This conditioning avoids, notably, dehydration of the bronchial and alveolar mucosa. However, since this conditioning is not perfect, exercising in cold air can induce lung inflammation, both for human and non-human mammals. This work aims to compare the air conditioning in the noses of various mammals during inspiration. We build our study on computational fluid dynamics simulations of the heat exchanges in the lumen of the upper respiratory tract of these mammals. These simulations show that the efficiency of the air conditioning in the nose during inspiration does not relate only to the mass m of the mammal but also to its maximal running speed v. More precisely, the results allow establishing a scaling law relating the efficiency of air conditioning in the nose of mammals to the ratio v / log 10 ( m ) . The simulations also correlate the resistance to the flow in the nose to the efficiency of this air conditioning. The obtained scaling law allows predicting the air temperature at the top of the trachea during inspiration for nasal-breathing mammals, and thus notably for humans of various ages.


Subject(s)
Air Conditioning , Running , Animals , Nose , Respiration , Mammals
5.
Heliyon ; 10(5): e26966, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38439865

ABSTRACT

Parking a solar electric car in the sunshine will help charge its battery, increasing its driving range. On the other hand, it will also raise its indoor temperature, leading to the need to switch on the air conditioning to make it comfortable when driving, increasing the driving load and reducing the vehicle range. Thus, one may wonder if the solar-extended range is somehow reduced or even eliminated by the increasing demand due to air conditioning. To address this "parking dilemma", we have characterized the thermal properties of a passenger car for typical summer conditions in a moderate latitude temperate location (Lisbon, Portugal) to be able to explore the vehicle's thermal performance when parked in the sun. Results show that effective solar charging depends critically on the onboard installed PV capacity. For the specific conditions tested and a 0.5 kWp PV system, the critical parking time below which the parking session does not contribute to net charging is around 2 h. For systems with more than 0.8 kWp installed capacity, parking in the sun always provides a positive impact on the vehicle's driving range.

6.
Environ Sci Pollut Res Int ; 31(17): 26330-26339, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38523217

ABSTRACT

Phase change materials enhance the thermal comfort of buildings by utilizing stored thermal energy. In large air-conditioning systems, ice storage plays a crucial role in managing peak power loads. This experimental study explores the freezing characteristics of deionized water containing suspended iron oxide nanoparticles in spherical containers for cold storage. The synthesized nanofluid phase change material (NFPCM) was investigated for its freezing behavior under surrounding fluid temperatures of - 2 °C and - 6 °C. The uniformity in charging of NFPCM is the unique feature prevalent in the first quarter of the charging, with 50% mass frozen observed. An increased surface heat flux of 200% was achieved using NFPCM at Tsurr = -6 °C. The chiller operational time is optimally reduced by 75% by considering twice the container design's phase change materials. Adding iron oxide nanoparticles and partial charging is suitable for uniform heat transfer for the shorter freezing duration in cooling applications. The novelty of the present study is that the proposed NFPCM nearly nullifies the subcooling effects of deionized water without using nucleating agents. This NFPCM appreciably enhances power competence, yielding large-scale air-conditioning systems' desired economic impact and sustainability. The reported results align with Sustainable Development Goals (7-Affordable and Clean Energy and 13-Climate Action).


Subject(s)
Cryopreservation , Ferric Compounds , Water , Cryopreservation/methods , Freezing , Temperature
7.
Environ Sci Pollut Res Int ; 31(18): 27304-27317, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38507162

ABSTRACT

The demand for cooling applications increases severalfold; the integration of the CTES system will mitigate the demand and pollution caused by the building sectors. The objective of this study is to investigate the effect of grooving on the inner surface of the spherical capsule on the solidification characteristics of deionized (DI) water, which finds widespread use in the bed of cool thermal energy storage applications. Eight hemispheres made of mild steel of 100-mm diameter and 1-mm thickness are used to make four spherical capsules by the welding process for the study. Among the four capsules, one with a plain surface and the remaining with a groove depth of 0.3 mm, 0.5 mm, and 0.7 mm are made. The grooving in the hemispherical capsule is obtained by the turning operation. The experiments are conducted at various bath temperatures of - 6 °C, - 9 °C, and - 12 °C. The experimental result reveals that the surface modification leads to a significant reduction in solidification time, and in particular, the maximum percentage reduction in solidification time is achieved at - 6 °C. The provision of grooves makes the evaporator operate at - 6 °C instead of - 12 °C till the solidification of 75% mass and the predicted energy saving is 18 to 24%. As the enhancement of heat transfer rate techniques is carbon-free, the recycling of the PCM will have zero impact on environmental pollution.


Subject(s)
Hot Temperature , Water/chemistry
8.
Appl Ergon ; 118: 104267, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38471333

ABSTRACT

Building maintenance encompasses multiple tightly inter-connected agents (e.g., technicians, occupants, supervisors, and equipment). Variable working conditions and limited resources may affect the safety and sustainability of the activities. Although recent studies have explored how complex systems can perform resilient behavior in facing the complexity of everyday activities, the factors that effectively contribute to resilient performance are still paired with limited empirical evidence. We studied the performance of the maintenance team during sudden breakdowns of air-conditioning devices in a large university campus, using the Functional Resonance Analysis Method (FRAM). A FRAM diagram containing 30 functions was organized including six macro-cognitive functions (expertise, sensemaking, communication, coordination, collaboration, and adaptation/improvisation), examining their role in anticipating, and responding to emergencies, and eight functional units that are directly impacted by disturbances were analyzed in more detail. Results indicate that macro-cognitive functions can greatly impact the functionality of the maintenance team in pursuit of their goals. Moreover, we noted those macro-cognitive functions here analyzed depend on each other to produce resilient performance.


Subject(s)
Cognition , Humans , Male , Air Conditioning , Communication , Task Performance and Analysis , Maintenance , Adult , Universities , Cooperative Behavior , Female , Young Adult
9.
Am J Biol Anthropol ; 184(2): e24932, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38516761

ABSTRACT

OBJECTIVES: Ecogeographic variation in human nasal anatomy has historically been analyzed on skeletal morphology and interpreted in the context of climatic adaptations to respiratory air-conditioning. Only a few studies have analyzed nasal soft tissue morphology, actively involved in air-conditioning physiology. MATERIALS AND METHODS: We used in vivo computer tomographic scans of (N = 146) adult individuals from Cambodia, Chile, Russia, and Spain. We conducted (N = 438) airflow simulations during inspiration using computational fluid dynamics to analyze the air-conditioning capacities of the nasal soft tissue in the inflow, functional, and outflow tract, under three different environmental conditions: cold-dry; hot-dry; and hot-humid. We performed statistical comparisons between populations and sexes. RESULTS: Subjects from hot-humid regions showed significantly lower air-conditioning capacities than subjects from colder regions in all the three conditions, specifically within the isthmus region in the inflow tract, and the anterior part of the internal functional tract. Posterior to the functional tract, no differences were detected. No differences between sexes were found in any of the tracts and under any of the conditions. DISCUSSION: Our statistical analyses support models of climatic adaptations of anterior nasal soft tissue morphology that fit with, and complement, previous research on dry skulls. However, our results challenge a morpho-functional model that attributes air-conditioning capacities exclusively to the functional tract located within the nasal cavity. Instead, our findings support studies that have suggested that both, the external nose and the intra-facial soft tissue airways contribute to efficiently warming and humidifying air during inspiration. This supports functional interpretations in modern midfacial variation and evolution.


Subject(s)
Climate , Humans , Male , Female , Adult , Tomography, X-Ray Computed , Young Adult , Nose/anatomy & histology , Nose/physiology , Nose/diagnostic imaging , Anthropology, Physical , Adaptation, Physiological/physiology , Middle Aged , Nasal Cavity/anatomy & histology , Nasal Cavity/physiology , Nasal Cavity/diagnostic imaging , Spain
10.
Sensors (Basel) ; 24(4)2024 Feb 09.
Article in English | MEDLINE | ID: mdl-38400309

ABSTRACT

A lack of available information on heating, ventilation, and air-conditioning (HVAC) systems can affect the performance of data-driven fault-tolerant control (FTC) models. This study proposed an in situ selective incremental calibration (ISIC) strategy. Faults were introduced into the indoor air (Ttz1) thermostat and supply air temperature (Tsa) and chilled water supply air temperature (Tchws) sensors of a central air-conditioning system. The changes in the system performance after FTC were evaluated. Then, we considered the effects of the data quality, data volume, and variable number on the FTC results. For the Ttz1 thermostat and Tsa sensor, the system energy consumption was reduced by 2.98% and 3.72% with ISIC, respectively, and the predicted percentage dissatisfaction was reduced by 0.67% and 0.63%, respectively. Better FTC results were obtained using ISIC when the Ttz1 thermostat had low noise, a 7-day data volume, or sufficient variables and when the Tsa and Tchws sensors had low noise, a 14-day data volume, or limited variables.

11.
Heliyon ; 10(2): e24288, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38293390

ABSTRACT

Isolation rooms are crucial in healthcare facilities to prevent the spread of infectious diseases. Infectious diseases can be transmitted to humans from humans or through animals known as zoonoses. With the increase in the number of COVID-19 cases, isolation rooms have become one of the most critical facilities in hospitals. Maintaining the correct temperature and humidity in these isolation rooms is a challenge, considering the heating, ventilation, and air conditioning (HVAC) systems that continuously consume large amounts of energy. With the application of energy conservation methods, the total energy consumption of HVAC systems can be reduced. Many studies have shown that the heat pipe heat exchanger (HPHE) technology can contribute significantly to energy savings using HVAC systems. In this study, the effectiveness of an HPHE on an HVAC system in an isolation room was examined, and the total energy reduction was quantified. The HPHE consisted of two rows with ten heat pipes in each row, arranged in a staggered configuration with fresh air temperature and mass flow variations. The inlet fresh air temperatures varied at 32, 35, 37, and 40 °C and fresh air velocities at 1.2, 1.6, 2.2, and 2.6 m/s. Using a chiller, the inlet fresh air was cooled to a comfortable temperature zone, approximately 24.4-25.2 °C, in the isolation room. Notably, higher velocities decreased the effectiveness of the HPHE. An increase in the flow rate enhanced the system, thereby improving the heat recovery value. The increase in the inlet fresh air temperature from 32 °C, that yielded an energy saving of 1.23 W, to 40 °C, resulted in a further energy saving of 1.85 W. The application of the HPHE in the HVAC system in isolation rooms represents a significant innovation that contributes to a reduction in total energy consumption.

12.
AORN J ; 119(1): 72-80, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38149898

ABSTRACT

Hospital construction and renovation is an ongoing occurrence in the health care setting. The recently updated AORN "Guideline for design and maintenance of the surgical suite" provides perioperative nurses with information on the layout design and maintenance of perioperative spaces; safety measures to use during construction and renovation; monitoring and maintenance of the heating, ventilation, and air conditioning; and how to respond to unintended utility failures. This article provides an overview of the guideline and discusses recommendations for the interdisciplinary team, planning and designing the surgical suite, construction-related environmental contamination, ORs, and OR maintenance. It also includes a scenario describing specific concerns associated with the construction of an additional OR. Perioperative nurses should review the guideline in its entirety and apply the recommendations when participating in perioperative construction and renovation projects.


Subject(s)
Air Conditioning , Ventilation , Humans
13.
Beyoglu Eye J ; 8(4): 280-286, 2023.
Article in English | MEDLINE | ID: mdl-38089076

ABSTRACT

Objectives: The present study evaluates the rate of endophthalmitis in intravitreal injections (IVI) performed in a modular injection cabin that could be easily sited in a closet in an office environment, and the performance tests of the cabin in terms of heating, ventilation, and air conditioning (HVAC). Methods: The injections were given over approximately 18 months in the cabin and the demographics of the patients were screened retrospectively, and the cabin was subjected to HVAC tests. Results: A total of 7,238 injections were performed in the defined period, and no cases of endophthalmitis were encountered (0%). The results of the airflow and flow rate, particle count, pressure difference, decontamination time, light, moisture, and heat tests were all found to be above the standard defined by the International Organization for Standardization (ISO). Conclusion: An injection cabin is a practical modular construction that can be easily sited in any space without the need for special climatization, and provides a sterile and safe environment for IVI.

14.
Heliyon ; 9(12): e23038, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38149192

ABSTRACT

Tractors are manufactured without air-conditioned cabins in Pakistan. This leads to thermal discomfort for tractor operators working under direct solar exposure. Therefore, this study aimed to design and install an air-conditioned cabin on a tractor. Experiments were undertaken to evaluate the installed cabin performance under two scenarios i.e., conventional (S-I) and enhanced (S-II) air distribution. Computational fluid dynamics (CFD) simulations were used to analyze airflow and calculate thermal comfort indices. The results showed that the air-conditioned cabin attained optimum thermal conditions under the enhanced air distribution scenario (S-II). In this scenario, the inside cabin temperature was an average of 27.4 °C, compared with 30.4 °C in S-I. The relative humidity remained similar in both scenarios, around 53 %. The temperature difference between the cabin and the ambient environment was 11.09 °C in S-II, aligning with the thermal comfort conditions outlined in ISO 14269-2. Furthermore, the CFD simulations showed a predicted mean vote (PMV) index of 0.61 and the percentage people dissatisfied (PPD) index of 26.5 %. These results also confirm the provision of optimum thermal conditions for operator inside the cabin. The simulations also demonstrated good agreement with experimental data, with a small difference in air temperature (2 °C) and relative humidity (5.8 %). In the light of these findings, this study recommends installation of air-conditioned cabin on tractors with enhanced air distribution (S-II) in Pakistan to improve thermal comfort of operators.

15.
J Urban Health ; 100(6): 1234-1245, 2023 12.
Article in English | MEDLINE | ID: mdl-37947996

ABSTRACT

Rising ambient temperatures due to climate change will impact both indoor temperatures and heating and cooling utility costs. In traditionally colder climates, there are potential tradeoffs in how to meet the reduced heating and increased cooling demands, and issues related to lack of air conditioning (AC) access in older homes and among lower-income populations to prevent extreme heat exposure. We modeled a typical multi-family home in Boston (MA) in the building simulation program EnergyPlus to assess indoor temperature and energy consumption in current (2020) and projected future (2050) weather conditions. Selected households were those without AC (no AC), those who ran AC sometimes (some AC), and those with sufficient resources to run AC always (full AC). We considered stylized cooling subsidy policies that allowed households to move between groups, both independently and in conjunction with energy efficiency retrofits. Results showed that future weather conditions without policy changes yielded an increase in indoor summer temperatures of 2.1 °C (no AC), increased cooling demand (range: 34-50%), but led to a decrease in net yearly total utility costs per apartment (range: - $21 to - $38). Policies that allowed households to move to greater AC utilization yielded average indoor summer temperature decreases (- 3.5 °C to - 6.2 °C) and net yearly total utility increases (range: + $2 to + $94) per apartment unit, with greater savings for retrofitted homes primarily due to large decreases in heating use. Our model results reinforce the importance of coordinated public policies addressing climate change that have an equity lens for both health and climate goals.


Subject(s)
Extreme Heat , Housing , Humans , Aged , Temperature , Boston , Seasons
16.
Environ Int ; 181: 108310, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37951014

ABSTRACT

BACKGROUND: Air conditioning (AC) presents a viable means of tackling the ill-effects of heat on human health. However, AC releases additional anthropogenic heat outdoors, and this could be detrimental to human health, especially in urban communities. This study determined the excess heat-related mortality attributable to anthropogenic heat from AC use under various projected global warming scenarios in seven Japanese cities. The overall protection from AC use was also measured. METHODS: Daily average 2-meter temperatures in the hottest month of August from 2000 to 2010 were modeled using the Weather Research and Forecasting (WRF) model with BEP+BEM (building effect parameterization and building energy model). Risk functions for heat-mortality associations were generated with and without AC use from a two-stage time series analysis. We coupled simulated August temperatures and heat-mortality risk functions to estimate averted deaths and unavoidable deaths from AC use. RESULTS: Anthropogenic heat from AC use slightly augmented the daily urban temperatures by 0.046 °C in Augusts of 2000-2010 and up to 0.181 °C in a future with 3 °C urban warming. This temperature rise was attributable to 3.1-3.5 % of heat-related deaths in Augusts of 2000-2010 under various urban warming scenarios. About 36-47 % of heat-related deaths could be averted by air conditioning use under various urban warming scenarios. DISCUSSION: AC has a valuable protective effect from heat despite some unavoidable mortality from anthropogenic heat release. Overall, the use of AC as a major adaptive strategy requires careful consideration.


Subject(s)
Air Conditioning , Extreme Heat , Mortality , Humans , Cities , Japan
17.
Heliyon ; 9(11): e22143, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38034636

ABSTRACT

Non-uniform environmental conditioning has established substantial energy-saving and conditioning effects in residential buildings, however, few studies on the technology applied in greenhouses have been conducted. Semi-enclosed greenhouse development is hindered by energy consumption. To better apply non-uniform environmental conditioning technology in greenhouses, it is necessary to investigate the non-uniform characteristics of field environment parameters. Therefore, spatial and temporal measurements of indoor temperature and relative humidity in a Venlo-type greenhouse in Yangling, China, were conducted on June 5-11, 2022. Temperature and humidity sensors were arranged in the greenhouse at 4.5 m intervals, in the canopy, cultivation, center, and root areas. Temperature and humidity measurement points on the greenhouse walls were selected. The measurement results showed large fluctuations in the indoor temperature and relative humidity over time. The difference between indoor and outdoor average temperatures ranged from -5-10 °C and temperatures unsuitable for tomato growth were identified, although some passive conditioning methods such as ventilation and water spraying were employed, which indicates the necessity of active heating and cooling. Based on the measured data, the nonuniformity coefficients of temperature and relative humidity in different directions in the greenhouse were calculated. A larger non-uniformity in the vertical direction was found compared to that in the horizontal direction. These results suggest the possibility of non-uniform environmental conditioning. A rough estimation of the energy consumption by the two different condition modes, namely zone-specific and overall conditioning, was made. A huge energy saving of 69.6 % by the zone-specific conditioning mode was revealed compared to the overall conditioning. This implies a huge advantage in energy efficiency by non-unform environmental conditioning technologies applied in greenhouses. The study provides useful data for understanding non-uniform environments in greenhouses and the application of non-uniform environmental conditioning technologies.

18.
Heliyon ; 9(10): e20333, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37822631

ABSTRACT

This paper aims to evaluate residential air conditioning systems' performance enhancement and optimization by adopting a novel functionalized Al2O3 (FAl2O3)-Polyolester (POE) nanolubricant. Comprehensive discussions were conducted on key performance parameters, including heat absorption, compressor work, cooling capacity, coefficient of performance (COP), and power consumption. Novel FAl2O3 nanoparticles were dispersed into the POE lubricant using a two-step method. The findings reveal that FAl2O3-POE nanolubricant exhibits superior heat absorption compared to pure POE. Heat absorption decreases with an increased initial refrigerant charge, while cooling capacity performance improves with an increased initial refrigerant charge. The COP shows an increasing trend at all concentrations of FAl2O3-POE nanolubricant when operating with R32. FAl2O3-POE/R32 demonstrates an enhanced range of 3.12%-32.26% for COP. The results suggest that applying novel FAl2O3-POE nanolubricant with R32 can reduce electrical power consumption by 13.79%-19.35%. The central composite design (CCD) offers an optimal condition for FAl2O3-POE nanolubricant with a concentration of 0.11 vol%, an initial refrigerant charge of 0.442 kg, resulting in a COP of 3.982, a standard error of 0.019, and a desirability of 1.0.

19.
Micromachines (Basel) ; 14(10)2023 Sep 25.
Article in English | MEDLINE | ID: mdl-37893263

ABSTRACT

The heat transfer characteristics of evaporative condensers in an R744 air conditioning system were evaluated using the numerical and the experimental methods. Two configurations of condensers were studied: Case 1 with five layers of tubes and Case 2 with eight layers of tubes. In order to evaluate the heat transfer characteristics, the temperature field, the phase change, the pressure distribution, and thermodynamic parameters were considered. For Case 2, it indicated the capability of R744 condensation from the superheated status to the liquified status by analyzing the outlet temperature of the condenser changed from 28.7 °C to 30.3 °C with a change in condensation pressure from 72.6 bar to 68.5 bar. In this study, R744 mass flow rate increases from 14.34 kg/h to 46.08 kg/h, and the pressure drop also increases from 0.23 bar to 0.47 bar for the simulation and 0.4 bar to 0.5 bar for the experiment, respectively. The results indicate that the five-layer configuration causes a higher pressure drop and lower COP than those obtained from the eight-layer one (splitting into two sets for smaller pressure drop). Furthermore, the evaporative condensers using mini tubes that are flooded in the cooling water tank are suitable for the subcritical R744 air conditioning system. In addition, the results obtained from the experimental data are in good agreement with those obtained from the numerical results, with a deviation of less than 5%.

20.
Environ Int ; 180: 108212, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37738697

ABSTRACT

Indoor dust contaminated with liquid crystal monomers (LCMs) released from various commercial liquid crystal display (LCD) screens may pose environmental health risks to humans. This study aimed to investigate the occurrence of 64 LCMs in ventilation and air conditioning filters (VACF) dust, characterize their composition profiles, potential sources, and associations with indoor characteristics, and assess their in vitro toxicity using the human lung bronchial epithelial cells (BEAS-2B). A total of 31 LCMs with concentrations (ΣLCMs) ranging from 43.7 ng/g to 448 ng/g were detected in the collected VACF dust. Additional analysis revealed the potential interactions between indoor environmental conditions and human exposure risks associated with the detected LCMs in VACF dust. The service area and working time of the ventilation and air conditioning system, and the number of indoor LCD screens were positively correlated with the fluorinated ΣLCMs in VACF dust (r = 0.355 âˆ¼ 0.511, p < 0.05), while the associations with the non-fluorinated ΣLCMs were not found (p > 0.05), suggesting different environmental behavior and fates of fluorinated and non-fluorinated LCMs in the indoor environment. Four main indoor sources of LCMs (i.e., computer (37.1%), television (28.3%), Brand A smartphone (21.2%) and Brand S smartphone (13.4%)) were identified by positive matrix factorization-multiple linear regression (PMF-MLR). Exposure to 14 relatively frequently detected LCMs, individually and in the mixture, induced significant oxidative stress in BEAS-2B cells. Among them, non-fluorinated LCMs, specifically 3cH2B and MeP3bcH, caused dominant decreased cell viability. This study provides new insights into the indoor LCMs pollution and the associated potential health risks due to the daily use of electronic devices.

SELECTION OF CITATIONS
SEARCH DETAIL
...