ABSTRACT
@#Objective - - To prepare the GDH 5 air sampling tube for simultaneous collection of eight kinds of chloro nitrobenzene ( ) , compounds CNBs in the air of workplace and establish a matching determination method using gas chromatography. Methods - - , Eight kinds of CNBs in vapor and aerosol state were collected by self developed GDH 5 air sampling tube desorbed , , , by toluene separated by polysiloxane gas chromatography column detected by microcell electron capture detector and Results - ( - quantified by external standard method. It was determined that the air sampling tube was assembled by XAD 2 ion ) - , exchange resin and glass fiber filter membrane. The linear range of CNBs was 0.80 240.00 mg/L and the linear correlation - - coefficients were greater than 0.999 9. The detection limit was 7.87 13.03 μg/L. The minimum detectable concentration was 0.60 3, - 3( ) 1.33 μg/m and the minimum quantitative concentration was 2.00 4.22 μg/m sample 45.00 L . The average desorption - - (RSD) - , - RSD efficiency was 101.2% 110.0%. The within run relative standard deviation was 0.8% 4.1% and the between run - Conclusion - was 0.3% 5.8%. The samples could be stored for more than 30 days at room temperature. GDH 5 air sampling tube and its associated determination method can be used for the collection and determination of eight kinds of CNBs in workplace air.
ABSTRACT
OBJECTIVE: To prepare and develop a GDH-2 air sampling tube for detecting 12 kinds of chlorobenzenes(CBs) in workplace air and to establish a matching detecting method. METHODS: The self-developed GDH-2 air sampling tube was filled with ion exchange resin and activated carbon, and the mass ratio was 10 ∶1. The GDH-2 air sampling tube was used to collect 12 kinds of CBs with coexistence of gaseous and aerosol in the air. After elution with toluene, they were separated on a chromatographic column and determined by microcell electron capture detector. RESULTS: The quantitative detecting range of the method was 0.51×10~(-3)-6 000.00 mg/L, with the correlation coefficients greater than 0.999 4. The minimum detection concentration was 0.02-61.99 μg/m~3, and the minimum quantitative concentration was 0.05-206.62 μg/m~3. The average desorption efficiency was 90.8%-104.0%. The within-run relative standard deviation(RSD) was 1.0%-5.7%, and the between-run RSD was 3.0%-7.3%. The samples can be stored at room temperature for at least 26 days. CONCLUSION: The self-developed GDH-2 air sampling tube and its matching measuring method can be used for the collection and determination of the 12 kinds of CBs in the air of workplace.
ABSTRACT
OBJECTIVE: To establish a method for simultaneous detection of 6 isomers of dimethylaniline(DMA) in workplace air by gas chromatography(GC). METHODS: The vapor and aerosol DMA in workplace air were collected by GDH-1 air sampling tube, and desorbed and eluted with absolute ethanol, then separated by a special capillary column for amines analysis, and finally detected by GC-flame ionization detector. RESULTS: The quantitative detection range of 6 isomers of DMA was 0.26-226.66 mg/L, with all the correlation coefficients greater than 0.999 00. The minimum detectable concentration was 0.01-0.02 mg/m~3, and the minimum quantification concentration was 0.04-0.05 mg/m~(3 )(15.00 L sample, 2.00 mL sample solution). The average desorption and elution efficiency was 92.48%-104.60%. The within-run relative standard deviations(RSD) was 0.31%-4.51%, and the between-run RSD was 1.23%-6.03%. The samples can be sealed and stored for more than 19 days at room temperature. CONCLUSION: The method is suitable for simultaneous detection of 6 isomers of DMA in workplace air.