Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Enferm Intensiva (Engl Ed) ; 34(1): 19-26, 2023.
Article in English | MEDLINE | ID: mdl-36774248

ABSTRACT

INTRODUCTION: Drawing blood samples through a central venous catheter (CVC) is a customary practice in Intensive Care Units (ICUs). It is indicated to discard a volume of waste blood to avoid interference in the results. AIM: To determine whether a lower discard volume for obtaining blood samples from temporary CVCs placed into the internal jugular, femoral or subclavian vein offers valid results. METHOD: A quasi-experimental prospective cross-sectional study for which sixty-five patients of over 18 years of age in ICUs, who had been fitted with a triple lumen central venous catheter, were recruited over a period of eight months. Two consecutive blood samples were extracted with tubes for biochemistry, coagulation and hemogram from each patient from the distal lumen. The first sample was obtained with a discarded waste of 1.5 ml from a total extracted volume of 10.2 ml, similar to the usual waste in our ambit (10 ml). Subsequently the second sample was obtained. The paired t-test was used to analyse the data. The Bland-Altman plot and intraclass correlation coefficient (ICC) were used to measure the agreement between methods. The reference change value (RCV) was established as the admissible limit of variation between the pairs of samples. RESULTS: A total of 65 sample pairs were drawn (intervention-control). The paired t-test found statistically significant differences with a significance level of α = .05 for chlorine (-.536; .012); prothrombin time (-.092; .019) and prothrombin activity (.284; 1.375).The ICC was greater than .9 in all the variables and the limit determined for the RCV was not surpassed by any value. CONCLUSIONS: The results show the reliability of the blood samples drawn with a discard volume of 1.5 ml.


Subject(s)
Central Venous Catheters , Critical Illness , Humans , Adolescent , Adult , Prospective Studies , Reproducibility of Results , Cross-Sectional Studies
2.
Enferm. intensiva (Ed. impr.) ; 34(1): 19-26, Ene-Mar. 2023. tab
Article in Spanish | IBECS | ID: ibc-214981

ABSTRACT

Introducción: La extracción de muestras sanguíneas a través de un catéter venoso central es una práctica habitual en las unidades de cuidados intensivos. Está indicado desechar un volumen de sangre, denominado volumen de descarte, con la finalidad de evitar que los resultados puedan verse alterados. Objetivo: Determinar si un menor volumen de descarte para la obtención de analíticas procedentes de catéter venoso central temporales alojados en la vena yugular interna, femoral o subclavia ofrece resultados válidos. Método: Estudio cuasiexperimental, prospectivo, transversal donde se seleccionaron 65 pacientes críticos mayores de 18 años portadores de catéter venoso central temporal de 3 luces durante un período de 8 meses. Para cada paciente se extrajeron 2 analíticas consecutivas de la luz distal con los valores de hemograma, bioquímica y coagulación comúnmente analizados en el paciente crítico. Se obtuvieron 2 muestras consecutivas: la primera, con un descarte de 1,5ml y un volumen extraído total de 10,2ml, similar al desecho habitual en nuestro medio (10 ml). Seguidamente se obtuvo la segunda muestra. Para el análisis de datos se utilizó la prueba t pareada; para medir la concordancia entre métodos, la representación de Bland-Altman y el coeficiente de correlación intraclase. Se estableció el valor de referencia del cambio como límite admisible de variación entre los pares de muestras. Resultados: Se extrajeron un total de 65 pares de muestras (intervención-control). El contraste de medias encontró diferencias estadísticamente significativas con α=0,05 para cloro (−0,536; 0,012), tiempo de protrombina (−0,092; 0,019) y actividad de protrombina (0,284; 1,375). El coeficiente de correlación intraclase resultó mayor de 0,9 en todas las variables y el valor de referencia del cambio no fue superado por ningún valor. Conclusiones: Los resultados muestran la validez de los análisis de las muestras de sangre extraídas con un volumen de descarte de 1,5ml.(AU)


Introduction: Drawing blood samples through a central venous catheter is a customary practice in intensive care units. It is indicated to discard a volume of waste blood to avoid interference in the results. Aim: To determine whether a lower discard volume for obtaining blood samples from temporary central venous catheters placed into the internal jugular, femoral or subclavian vein offers valid results. Method: A quasi-experimental prospective cross-sectional study for which 65 patients of over 18 years of age in intensive care units, who had been fitted with a triple lumen central venous catheter, were recruited over a period of 8 months. Two consecutive blood samples were extracted with tubes for biochemistry, coagulation and haemogram from each patient from the distal lumen. The first sample was obtained with a discarded waste of 1.5ml from a total extracted volume of 10.2ml, similar to the usual waste in our ambit (10ml). Subsequently the second sample was obtained. The paired t-test was used to analyse the data. The Bland-Altman plot and intraclass correlation coefficient were used to measure the agreement between methods. The reference change value was established as the admissible limit of variation between the pairs of samples. Results: A total of 65 sample pairs were drawn (intervention-control). The paired t-test found statistically significant differences with a significance level of α=0.05 for chlorine (−0.536; 0.012); prothrombin time (−0.092; 0.019) and prothrombin activity (0.284; 1.375). The intraclass correlation coefficient was greater than 0.9 in all the variables and the limit determined for the reference change value was not surpassed by any value. Conclusions: The results show the reliability of the blood samples drawn with a discard volume of 1.5ml.(AU)


Subject(s)
Humans , Male , Female , Blood Specimen Collection , Central Venous Catheters , Blood Chemical Analysis , Intensive Care Units , Anemia , Nursing , Critical Care Nursing , Prospective Studies , Cross-Sectional Studies
3.
Rev. bras. med. esporte ; 29(spe1): e2022_0199, 2023. tab, graf
Article in English | LILACS | ID: biblio-1394846

ABSTRACT

ABSTRACT Introduction Nowadays, more people are concerned with physical exercise and swimming competitions, as a major sporting event, have become a focus of attention. Such competitions require special attention to their athletes and the use of computational algorithms assists in this task. Objective To design and validate an algorithm to evaluate changes in vital capacity and blood markers of athletes after swimming matches based on combined learning. Methods The data integration algorithm was used to analyze changes in vital capacity and blood acid after combined learning swimming competition, followed by the construction of an information system model to calculate and process this algorithm. Results Comparative experiments show that the neural network algorithm can reduce the calculation time from the original initial time. In the latest tests carried out in about 10 seconds, this has greatly reduced the total calculation time. Conclusion According to the model requirements of the designed algorithm, practical help has been demonstrated by building a computational model. The algorithm can be optimized and selected according to the calculation model according to the reality of the application. Level of evidence II; Therapeutic studies - investigation of treatment outcomes.


RESUMO Introdução Atualmente, mais pessoas preocupam-se com o exercício físico e as competições de natação, como evento esportivo de destaque, tornou-se foco de atenção. Tais competições exigem atenção especial aos seus atletas e o uso de algoritmos computacionais auxiliam nessa tarefa. Objetivo Projetar e validar um algoritmo para avaliação das alterações da capacidade vital e marcadores sanguíneos dos atletas após os jogos de natação baseados no aprendizado combinado. Métodos O algoritmo de integração de dados foi usado para analisar as mudanças de capacidade vital e ácido sanguíneo após competição de natação de aprendizado combinado, seguido à construção de um modelo de sistema de informação para calcular e processar esse algoritmo. Resultados Experiências comparativas mostram que o algoritmo de rede neural pode reduzir o tempo de cálculo a partir do tempo inicial original. Nos últimos testes levados à cabo em cerca de 10 segundos, isto reduziu muito o tempo total de cálculo. Conclusão De acordo com os requisitos do modelo do algoritmo projetado, foi demonstrada a ajuda prática pela construção de um modelo computacional. O algoritmo pode ser otimizado e selecionado de acordo com o modelo de cálculo, segundo a realidade da aplicação. Nível de evidência II; Estudos terapêuticos - investigação dos resultados do tratamento.


RESUMEN Introducción Hoy en día, cada vez más personas se preocupan por el ejercicio físico y las competiciones de natación, como evento deportivo destacado, se han convertido en un foco de atención. Estas competiciones requieren una atención especial para sus atletas y el uso de algoritmos computacionales ayuda en esta tarea. Objetivo Diseñar y validar un algoritmo para evaluar los cambios en la capacidad vital y los marcadores sanguíneos de los atletas después de los partidos de natación basado en el aprendizaje combinado. Métodos Se utilizó el algoritmo de integración de datos para analizar los cambios de la capacidad vital y la acidez de la sangre tras la competición de natación de aprendizaje combinado, seguido de la construcción de un modelo de sistema de información para calcular y procesar este algoritmo. Resultados Los experimentos comparativos muestran que el algoritmo de la red neuronal puede reducir el tiempo de cálculo con respecto al tiempo inicial. En las últimas pruebas realizadas en unos 10 segundos, esto redujo en gran medida el tiempo total de cálculo. Conclusión De acuerdo con los requisitos del modelo del algoritmo diseñado, se ha demostrado la ayuda práctica mediante la construcción de un modelo computacional. El algoritmo puede optimizarse y seleccionarse según el modelo de cálculo en función de la realidad de la aplicación. Nivel de evidencia II; Estudios terapéuticos - investigación de los resultados del tratamiento.


Subject(s)
Humans , Swimming/physiology , Algorithms , Biomarkers/analysis , Deep Learning , Athletic Performance/physiology , Athletes
4.
Rev. bras. med. esporte ; 22(1): 35-39, jan.-fev. 2016. tab
Article in Portuguese | LILACS | ID: lil-771101

ABSTRACT

RESUMO Introdução: O parkour é uma atividade que utiliza o próprio corpo para deslocar-se de um ponto a outro no ambiente. Objetivo: Analisar o comportamento do metabolismo energético e do sistema cardiorrespiratório durante uma sessão de parkour. Método: Foram avaliados 18 indivíduos praticantes da modalidade. O comportamento do metabolismo energético durante uma sessão de parkour foi avaliado por meio da frequência cardíaca (FC), lactato e glicose. Resultados: Os resultados indicaram que a FC média durante a sessão de treino foi de 167,64 ± 7,05 bpm representando 84,36 ± 3,52 %. O lactato inicial foi de 4,49 ± 3,08 mmol/L e o final de 9,23 ± 3,08 mmol/L onde p-valor para as variáveis foi de p = 0,0007. A glicose inicial foi de 73,6 ± 20,71 mg/dL e final de 76,06 ± 20,20 mg/dL assumindo um p-valor de p = 0,7408. Em se tratando da composição corporal, o percentual de gordura foi de 8,78 ± 2,82 %, a dobra que mais apresentou acúmulo de gordura foi do abdômen 12,32 ± 5,69 mm. Conclusão: Conclui-se que a modalidade parkour tem predominância do metabolismo anaeróbio glicolítico, com suporte do metabolismo aeróbio. Além disso, devido à especificidade da modalidade, seus praticantes possuem baixo percentual de gordura.


ABSTRACT Introduction: Parkour is an activity that uses the own body to move from a point to another in the environment. Objective: Analyzing the behavior of the energetic metabolism and the cardiorespiratory system during a parkour session. Method: Eighteen parkour practitioners were evaluated. The behavior of the energetic metabolism during the parkour session was measured by heart rate (HR), lactate and glucose. Results: The results indicated that the average HR during the training session was 167.64 ± 7.05 bpm representing 84.36 ± 3.52 %. The initial lactate level was 4.49 ± 3.08 mmol/L and the final level was 9.23 ± 3.08 mmol/L where p-value for both variables was p = 0.0007. The initial glucose was 73.6 ± 20.71 mg/dL and the final glucose 76.06 ± 20.20 mg/dL, with a p-value of p = 0.7408. In terms of body composition, the fat percentage was 8.78 ± 2.82 %, the skinfold with highest fat amount was the abdomen 12.32 ± 5.69 mm. Conclusion: The conclusion was that the parkour modality has predominance of the anaerobic glycolytic metabolism, with support of the aerobic metabolism. Besides, due to the specificity of the modality, its practitioners have low levels of body fat.


RESUMEN Introducción: Parkour es una actividad que utiliza el propio cuerpo para desplazarse de un punto a otro en el ambiente. Objetivo: Analizar el comportamiento del metabolismo energético y del sistema cardiorrespiratorio durante una sesión de parkour. Metodología: Se evaluaron 18 individuos que practican el la modalidadparkour. Fue evaluado el comportamiento del metabolismo energético durante una sesión de parkour a través de la frecuencia cardiaca (FC), lactato y glucosa. Resultados: Los resultados indicaron que el FC promedio durante la sesión de entrenamiento fue de 167,64 ± 7,05 lpm lo que representa 84,36 ± 3,52 %. El lactato inicial fue de 4,49 ± 3,08 mmol/L y el final 9,23 ± 3,08 mmol/L en donde el p-valor para las variables fue de p = 0,0007. La glucosa inicial fue de 73,6 ± 20,71 mg/dL y la final 76,06 ± 20,20 mg/dL asumiendo un valor de p = 0,7408. Al tratarse de la composición corporal, el porcentaje de grasa fue de 8,78 ± 2,82 %, el pliegue que mostró más acumulación de grasa fue del abdomen 12,32 ± 5,69 mm. Conclusión: Se concluye que la modalidad parkour tiene predominio del metabolismo anaeróbico glucolítico con el apoyo del metabolismo aeróbico. Además, debido a la especificidad de la modalidad, sus practicantes tienen bajo porcentaje de grasa corporal.

5.
Rev. bras. med. esporte ; 22(1): 49-53, jan.-fev. 2016. tab
Article in English | LILACS | ID: lil-771107

ABSTRACT

ABSTRACT Introduction: Although the harmful effects of smoking on the cardiovascular and respiratory systems have been established for a long time, the effect on physiological and physical parameters in modern female dancers is not well documented. Objective: To determine differences in selected pulmonary functions, biochemical parameters, and body composition in female smoker and non-smoker modern dancers who are university or graduate students. Methods: A total of twenty-two female modern dancers (mean age of 24.6 ± 4.3 years), who were non-smokers (n = 11) and smokers (n = 11), voluntarily participated in the study. The smokers had been smoking 1 to 20 cigarettes per day for an average period of seven years. The pulmonary function test Mir Spirobank Spirometer, (Italy) was applied; selected biochemical parameters were tested, and various anthropometric measurements (height, weight and seven skinfold thickness) were performed. The results of body composition were evaluated using Jackson-Pollock equations. Intergroup comparisons were performed using the Mann-Whitney U test. Result: No significant differences were found between smoker and non-smoker dancers in terms of body composition (body fat, % body fat, lean body fat) and selected biochemical parameters (p > 0.05). However, non-smokers had prediction values of forced expiratory volume during the first second (FEV1) and peak expiratory flow (PEF) significantly better (p < 0.05). The effect of smoking on the performance of female modern dancers should be examined in a longitudinal study, with a higher number of participants. Conclusion: It was observed that smoking reduces lung pulmonary capacity at a certain rate, although the biochemical parameters and body composition of the female smoker and non-smoker dancers were similar.


RESUMO Introdução: Embora os efeitos nocivos do fumo nos sistemas cardiovascular e respiratório tenham sido estabelecidos há muito, o efeito sobre os parâmetros fisiológicos e físicos em bailarinas de dança moderna não foi bem documentado ainda. Objetivo: Determinar as diferenças em funções pulmonares selecionadas, parâmetros bioquímicos e composição corporal em bailarinas de dança moderna fumadoras e não-fumadoras, universitárias e pós-universitárias. Métodos: Vinte e duas bailarinas de dança moderna (média de idade de 24,6 ± 4,3 anos), não fumantes (n = 11) e fumantes (n = 11), participaram voluntariamente no estudo. As fumantesconsumiram de 1 a 20 cigarros por dia durante uma média de sete anos. Foi aplicado o teste funcional pulmonar Mir Spirobank Spirometer, (Itália), alguns parâmetros biomédicos selecionados foram testados e foram realizadas várias medições antropométricas (altura, peso e sete espessuras de pregas cutâneas). Os resultados da composição corporal foram avaliados usando equações Jackson-Pollock. As comparações intergrupo foram realizadas usando o teste "U" de Mann-Whitney. Resultado: Não foram encontradas diferenças significativas entre as bailarinas fumantes e não fumantes quanto à composição corporal (gordura corporal, % massa gorda, massa corporal magra) e nos parâmetros bioquímicos selecionados (p > 0,05). No entanto, as não fumantes tinham valores de predição do volume expiratório forçado no primeiro segundo (VEF1) e pico de fluxo expiratório (PFE) significativamente melhores (p < 0,05). O efeito do tabagismo no desempenho de bailarinas de dança moderna deveria ser examinado num estudo longitudinal, com um maior número de participantes. Conclusão: Foi observado que o fumo reduz a capacidade pulmonar a uma certa taxa, embora os padrões bioquímicos e a composição corporal das bailarinas fumantes e não fumantes fossem semelhantes.


RESUMEN Introducción: Aunque los efectos nocivos del tabaco en los sistemas cardiovascular y respiratorio hayan sido establecidos hace mucho, el efecto sobre los parámetros fisiológicos y físicos en bailarinas de danza moderna no fue aún bien documentado. Objetivo: Determinar las diferencias en funciones pulmonares seleccionadas, parámetros bioquímicos y composición corporal en bailarinas de danza moderna fumadoras y no fumadoras, universitarias y post universitarias. Método: Veintidós bailarinas de danza moderna (edad promedio de 24,6 ± 4,3 años), no fumadoras (n=11) y fumadoras (n=11), participaron voluntariamente en el estudio. Las fumadoras habían fumado desde 1 hasta 20 cigarrillos por día durante un promedio de siete años. Fue aplicado el test funcional pulmonar espirómetro Mir Spirobank, (Italia), y fueron hechos algunos tests de parámetros biomédicos seleccionados y hechas varias mediciones antropométricas (altura, peso y siete espesores de los pliegues cutáneos). Los resultados de la composición corporal fueron evaluados usando ecuaciones Jackson-Pollock. Las comparaciones intergrupales fueron realizadas usando el test Mann-Whitney U. Resultado: No fueron encontradas diferencias significativas entre bailarinas fumadoras y no fumadoras en la composición corporal (grasa corporal, % de masa grasa, masa corporal magra) y en los parámetros bioquímicos seleccionados (p > 0,05). Sin embargo, las no fumadoras tuvieron valores de predicción del volumen espiratorio forzado en el primer segundo (VEF1) y del flujo espiratorio máximo (FEM) significativamente mejores (p < 0,05). El efecto del tabaco en el desempeño de bailarinas de danza moderna debería ser examinado en un estudio longitudinal, con un aumento del número de participantes. Conclusión: Se observó que el tabaco reduce la capacidad pulmonar a una cierta tasa, aunque los estándares bioquímicos y la composición corporal de las bailarinas fumadoras y no fumadoras fueron similares.

6.
Rev. Fac. Med. (Bogotá) ; 63(4): 617-623, oct.-dic. 2015. ilus, tab
Article in Spanish | LILACS | ID: lil-767566

ABSTRACT

Antecedentes. Actualmente, el sedentarismo en Chile, más que un tema de moda, es un grave problema para la salud que, además, se asocia con el desarrollo de enfermedades crónicas no transmisibles. Objetivo. Determinar los efectos de un programa de ejercicio físico de sobrecarga de dos meses de duración, hasta el fallo muscular, sobre el perfil lipídico de adultos sedentarios. Materiales y métodos. Estudio de tipo experimental, con pre-prueba y pos-prueba, en una muestra de 16 sujetos que fueron divididos en dos grupos: adherente (GA, n=8, edad=34.88+6.89 años) y no adherente (GNA, n=8, edad=35.13+6.64años). La muestra es de tipo no probabilística, con sujetos elegidos de manera no aleatoria por conveniencia. Los participantes del GA fueron sometidos a ejercicio físico de sobrecarga hasta el fallo muscular dos veces por semana durante dos meses. Antes y 72 horas después de la última sesión de intervención, se evaluó, en ambos grupos (en ayuno ≥12 horas), colesterol total (Col-total), colesterol HDL (C-HDL), colesterol LDL (C-LDL) y triglicéridos (TG). Resultados. Posterior a la intervención no se encontraron diferencias significativas (p>0.05) en Col-total, C-HDL, C-LDL y TG. Conclusiones. Si bien se observa una tendencia a la baja en el perfil lipídico, una mayor duración y/o frecuencia de intervención podría ser necesaria para modificar significativamente las variables plasmáticas.


Background. Today, physical inactivity in Chile, rather than a fashion aspect is a serious health problem associated with the development of chronic non-transmissible diseases. Objective.To determine the effects of a two-month overload exercise program up to muscular failure on the lipid profile of sedentary adults. Materials and methods. An experimental study type with pre-test and post-test carried out on a sample of 16 subjects divided into two groups. Group Adherent (GA, n = 8, age = 34.88 + 6.89 years) and Group non-adherent (GNA, n = 8, age = 35.13 + 6.64 years). The sample is a non-probabilistic type, with subjects chosen for convenience in a non-random way. GA participants underwent physical resistance exercise up to muscular failure twice a week during two months. Total cholesterol (total-Col), HDL cholesterol (HDL-C), LDL cholesterol (LDL-C) and triglycerides (TG) were evaluated in both groups (fasting ≥12 hours) before and 72 hours after the last intervention session. Results. After the intervention there were not significant differences (p> 0.05) in total-Col, HDL-C, LDL-C and TG. Conclusions. While a downward trend in the lipid profile is noted, a longer duration and/or more frequent intervention may be needed to significantly alter the plasma variables.

7.
Medisur ; 12(1): 135-139, feb. 2014.
Article in Spanish | LILACS | ID: lil-760251

ABSTRACT

Fundamento: la neumonía adquirida en la comunidad constituye un importante problema de salud a nivel mundial, en Cuba y en la provincia de Cienfuegos. Objetivo: comunicar los resultados obtenidos con la realización de hemocultivos al ingreso hospitalario en pacientes con neumonía adquirida en la comunidad. Métodos: estudio descriptivo y prospectivo realizado en el Hospital Gustavo Aldereguía, de Cienfuegos, durante segundo semestre del año 2012, que incluyó 52 pacientes con neumonía adquirida en la comunidad a los que se les realizó hemocultivo a su ingreso hospitalario.Resultados: en solo cinco pacientes el examen arrojó un resultado positivo (9,6 % de los casos); en un solo caso con cultivo positivo se aisló Streptococcus pneumoniae; en el resto fueron aislados Staphylococcus aureus y Klebsiella pneumoniae. Conclusiones: el porcentaje obtenido reafirma el bajo rendimiento diagnóstico del hemocultivo al ingreso en los pacientes con neumonía adquirida en la comunidad, fue llamativo, también, el bajo porcentaje de aislamiento de S. pneumoniae en este estudio.


Background: community-acquired pneumonia is a major health problem worldwide, in Cuba and in the province of Cienfuegos. Objective: to report the results of blood cultures performed at hospital admission in patients with community-acquired pneumonia. Methods: a prospective descriptive study was conducted in the Gustavo Aldereguía Lima Hospital in Cienfuegos, during the second half of 2012. It included 52 patients with community-acquired pneumonia who underwent blood culture at their admission to the hospital. Results: only five patients (9.6% of the cases) had a positive test result; Streptococcus pneumoniae was isolated from only one positive culture; Staphylococcus aureus and Klebsiella pneumoniae were isolated from the rest. Conclusions: the percentage obtained in this study confirms the low diagnostic yield of blood cultures performed at admission in patients with community-acquired pneumonia; the low isolation rate of S. pneumoniae in our study was also significant.

8.
Medisur ; 12(1)2014. tab
Article in Spanish | CUMED | ID: cum-56109

ABSTRACT

Fundamento: la neumonía adquirida en la comunidad constituye un importante problema de salud a nivel mundial, en Cuba y en la provincia de Cienfuegos.Objetivo: comunicar los resultados obtenidos con la realización de hemocultivos al ingreso hospitalario en pacientes con neumonía adquirida en la comunidad. Métodos: estudio descriptivo y prospectivo realizado en el Hospital Gustavo Aldereguía, de Cienfuegos, durante segundo semestre del año 2012, que incluyó 52 pacientes con neumonía adquirida en la comunidad a los que se les realizó hemocultivo a su ingreso hospitalario.Resultados: en solo cinco pacientes el examen arrojó un resultado positivo (9,6 por ciento de los casos); en un solo caso con cultivo positivo se aisló Streptococcus pneumoniae; en el resto fueron aislados Staphylococcus aureus y Klebsiella pneumoniae.Conclusiones: el porcentaje obtenido reafirma el bajo rendimiento diagnóstico del hemocultivo al ingreso en los pacientes con neumonía adquirida en la comunidad, fue llamativo, también, el bajo porcentaje de aislamiento de S. pneumoniae en este estudio(AU)


Background: community-acquired pneumonia is a major health problem worldwide, in Cuba and in the province of Cienfuegos.Objective: to report the results of blood cultures performed at hospital admission in patients with community-acquired pneumonia. Methods: a prospective descriptive study was conducted in the Gustavo Aldereguía Lima Hospital in Cienfuegos, during the second half of 2012. It included 52 patients with community-acquired pneumonia who underwent blood culture at their admission to the hospital. Results: only five patients (9.6 percent of cases) had a positive test result; Streptococcus pneumoniae was isolated from only one positive culture; Staphylococcus aureus and Klebsiella pneumoniae were isolated from the rest.Conclusions: the percentage obtained in this study confirms the low diagnostic yield of blood cultures performed at admission in patients with community-acquired pneumonia; the low isolation rate of S. pneumoniae in our study was also significant(AU)


Subject(s)
Humans , Pneumonia/diagnosis , Pneumonia/epidemiology , Cuba , Blood Chemical Analysis , Community-Acquired Infections/diagnosis , Community-Acquired Infections/epidemiology , Epidemiology, Descriptive
9.
Rev. costarric. salud pública ; 21(2): 58-64, jul.-dic. 2012. tab
Article in Spanish | LILACS | ID: lil-681754

ABSTRACT

Se relacionó el grado de contaminación con aluminio en suero sanguíneo de pacientes sometidos a tratamientos de diálisis con el contenido de aluminio en los líquidos de diálisis que usaron estos pacientes y las alteraciones que mostraron en su salud. Método: Se analizaron por espectrometría de absorción atómica con horno de grafito (EAA) muestras de suero sanguíneo de 34 pacientes y dializados de dos instituciones hospitalarias de la ciudad de Cali-Colombia. Las muestras de suero se diluyeron 1:4 con el modificador (nitrato de magnesio y Triton X-100, al 1 por ciento), y las de dializados se acidularon al 1,3 por ciento. Resultados: Los pacientes del Hospital Universitario del Valle (desionizaba el agua para preparar el dializado), mostraron concentraciones de aluminio sérico menores (60+20ug L-1)que los del Instituto de Seguros Sociales (511+96 ug L-1), donde no trataban esta agua. Los pacientes del instituto presentaron una mayor incidencia de enfermedades relacionadas con el aluminio que los del Hospital. La exactitud del método analítico estuvo entre 99-101 por ciento y los límites de detección fueron 1,5 para suero sanguíneo y 1,2 ug L-1 para dializados. Conclusión: Hubo una relación directa entre el contenido de aluminio en sangre y dializados con la frecuencia de enfermedades relacionadas con este metal...


Subject(s)
Humans , Male , Female , Middle Aged , Aged, 80 and over , Aluminum , Blood Chemical Analysis , Dialysis , Colombia
SELECTION OF CITATIONS
SEARCH DETAIL
...