Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 288
Filter
1.
Acta Med Philipp ; 58(2): 63-68, 2024.
Article in English | MEDLINE | ID: mdl-38966155

ABSTRACT

Background: Surgical correction of aphakia without capsular support continues to be a challenge. Improvements in the technology of cataract surgery have provided advancements in techniques in surgical management of aphakia. Locally, we have limited data on the outcomes of the different intraocular lenses used in aphakia. Objective: This study aimed to determine visual outcomes and complications associated with different techniques of intraocular lens implantation in the absence of capsular support. Methods: We reviewed the medical charts of 207 patients who underwent intraocular lens implantation without capsular support. Excluded were patients with incomplete follow up, pediatric patients, and lost records. Best corrected visual acuity at day 1, 1st month, 3rd month and 6th month postoperatively, and the complications were noted. Results: Mean age was 60 and 51% (n=105) were females. The mean follow-up time was 9.33 ± 0.71 months. Loss of capsular support was most frequently caused by intraoperative complication (n=146, 70%) and trauma. Retropupillary fixation iris claw intraocular lens was frequently used (n=93, 44.9%). Across all patients, visual acuities showed excellent outcomes with 20/50 or better. Across IOL types, the most frequent postoperative complication was increase in IOP. Statistically significant results were set at P <0.05. Conclusion: There is a notable preference towards iris claw retropupillary lenses through time. Iris claw lenses showed the shortest operative time. All intraocular lenses used in aphakia showed comparably good postoperative visual acuities, except for the superior visual acuity trend seen among retropupillary iris claw and anterior chamber IOL groups. Complications included elevated intraocular pressures, corneal edema, and pigment dispersion.

2.
Ophthalmol Ther ; 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38951315

ABSTRACT

INTRODUCTION: A novel technique is described employing scleral grooves to facilitate sutureless scleral fixation of the Carlevale intraocular lens (CIL). We describe its use in a series of 47 patients with aphakia. METHODS: A retrospective study of all patients with aphakia who underwent CIL implantation with the new technique by a single surgeon during 1 year. The novelty of this technique consists in the creation of two partial-thickness linear sclerotomies (grooves), 180° apart, 2 mm from and parallel to the limbus. In the middle of each groove a full-thickness sclerotomy is performed to facilitate externalization of the CIL anchors. The groove allows the anchor to plug the full-thickness sclerotomy and to rest within the sclera without protrusion. Reported outcomes include pre-operative/post-operative visual acuity, post-operative spherical equivalent and surgical complications. Follow-up was a minimum of 6 months. RESULTS: Forty-eight eyes of 47 patients with aphakia with a mean age of 74 years (range 31-90 years) are included. The commonest causes of aphakia were intraocular lens (IOL) subluxation,with or without exfoliation (54.2%), complicated cataract surgery (29.2%), crystalline lens luxation (6.3%) and trauma (4.1%). All CILs inserted with the new technique stayed successfully in situ during follow-up. Median pre-operative best-corrected visual acuity (0.75 logMAR; range 0.1-2.7) significantly improved to 0.5 logMAR post-operatively (p < 0.001). Moreover, 78% and 65% of the operated cases were within 1.0 and 0.5 diopters, respectively, from intended refraction. The most common complications were transient cystoid macular oedema (8.3%) and transient intraocular pressure rise (8.3%), all of which resolved within 2 months. CONCLUSIONS: The proposed modification of sutureless scleral fixation of the CIL appears safe and effective. In our experience it is less time consuming and easier to perform than previous techniques and may therefore offer a useful future option.

3.
Saudi J Ophthalmol ; 38(2): 163-167, 2024.
Article in English | MEDLINE | ID: mdl-38988779

ABSTRACT

PURPOSE: This study aims to introduce a new suture method and report surgical outcomes of patients who underwent scleral-fixated intraocular lens (SF-IOL) implantation combined with either pars plana vitrectomy (PPV) or anterior vitrectomy (AV). METHODS: Twenty-three eyes performed SF-IOL implantation combined with PPV (Group 1), and 34 eyes performed SF-IOL implantation combined with AV (Group 2) were included in the study prospectively. The SF-IOL, either polymethyl methacrylate or foldable IOL, was sutured into the sclera using PC-9 sutures in an irregular, knotless, and zigzag-shaped manner. The scleral tunnel was approximately 12-15 mm long, with at least four sharp edges. Suture tips were trimmed within the scleral tunnel. Postoperative outcomes and complications were evaluated. RESULTS: Both groups showed no complications such as suture tip expulsion, suture reaction, IOL dislocation, or increased intraocular pressure during postoperative visits. Group 1 exhibited a statistically significant improvement in visual acuity compared to preoperative values (P = 0.036 for the 1st month, <0.001 for the 3rd month). Similarly, Group 2 demonstrated a statistically significant improvement in visual acuity compared to the preoperative period (P = 0.001 for the 1st month, <0.001 for the 3rd month). CONCLUSION: The "irregular, knotless, and zigzag-shaped scleral tunnel suture technique" yielded favorable results in terms of IOL stability and visual acuity. This technique can be safely employed in patients undergoing SF-IOL implantation combined with PPV or AV.

4.
Medicina (Kaunas) ; 60(6)2024 May 25.
Article in English | MEDLINE | ID: mdl-38929482

ABSTRACT

Different techniques for artificial iris implantation with or without an intraocular lens, depending on lens status, are described in the literature. We describe a surgical technique for a custom-made artificial iris and toric-intraocular lens intrascleral flange fixation. We modified the "Backpack" artificial iris implantation surgical technique to facilitate an accurate alignment of the toric-intraocular lens in a patient with aphakia, aniridia, and high asymmetric astigmatism secondary to blunt trauma. Two months after the surgery, uncorrected visual acuity was 20/30, corrected to 20/25 with a refraction of -2.00 in the diopter sphere with no residual astigmatism. The artificial iris implant and toric-intraocular lens were well-centered. The patient was satisfied with the visual and cosmetic outcomes. This procedure, however, is not complication-free as our patient developed uveitis and increased intraocular pressure during the postoperative period, which was treated successfully.


Subject(s)
Iris , Lenses, Intraocular , Humans , Iris/surgery , Iris/injuries , Sclera/surgery , Lens Implantation, Intraocular/methods , Visual Acuity , Astigmatism/surgery , Astigmatism/etiology , Male , Aniridia/surgery , Female
5.
Int Ophthalmol ; 44(1): 269, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38914871

ABSTRACT

PURPOSE: Evaluation of anterior segment parameters using the Scheimpflug corneal topography 1 year after surgery in patients who underwent sutureless scleral fixation intraocular lens (SFIOL) implantation using the modified Yamane technique and retropupillary iris-claw intraocular lens (RPIOL) implantation. METHODS: A total of 60 eyes from 57 patients who underwent sutureless SFIOL implantation and 57 eyes from 52 patients who underwent RPIOL implantation were included. Anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), anterior-posterior corneal astigmatism, and keratometric values were assessed using the Scheimpflug corneal topography (Pentacam HR, Germany). RESULTS: There was no statistically significant difference in postoperative UCVA and BCVA between the sutureless SFIOL and the RPIOL group (p = 0.236, p = 0.293, respectively). While there was no statistically significant difference in postoperative IOP between the two groups (p = 0.223), a statistically significant decrease in IOP was observed in both groups (p < 0.001). While there was no statistical difference between the sutureless SFIOL group and the RPIOL group in terms of spherical value (p = 0.441) and spherical equivalence (p = 0.237), there was a statistically significant difference in cylindrical value (p < 0.001). While there was a statistical difference in anterior astigmatism (p < 0.001), there was no statistical difference in posterior astigmatism (p = 0.405). There was no statistical difference in terms of ACV, ACD, and ACA between the sutureless SFIOL and the RPIOL group (p = 0.812, p = 0.770, p = 0.401, respectively). CONCLUSION: In this study, although there was a statistical difference in cylindrical value and anterior corneal astigmatism between the sutureless SFIOL and RPIOL groups, vision was not affected. According to this study, sutureless SFIOL and RPIOL are two successful methods in terms of visual acuity, anterior segment, and keratometry outcomes in aphakic patients after phacoemulsification.


Subject(s)
Corneal Topography , Iris , Lens Implantation, Intraocular , Sclera , Sutureless Surgical Procedures , Visual Acuity , Humans , Male , Female , Sclera/surgery , Lens Implantation, Intraocular/methods , Middle Aged , Aged , Iris/surgery , Sutureless Surgical Procedures/methods , Lenses, Intraocular , Retrospective Studies , Anterior Eye Segment/diagnostic imaging , Anterior Eye Segment/surgery , Adult , Treatment Outcome , Prosthesis Design , Aphakia, Postcataract/surgery , Aphakia, Postcataract/physiopathology , Follow-Up Studies , Aphakia/surgery , Aphakia/physiopathology , Aphakia/diagnosis
6.
Cureus ; 16(5): e59435, 2024 May.
Article in English | MEDLINE | ID: mdl-38826882

ABSTRACT

Aphakia is a condition in which the eye's crystalline lens is not in its proper position because of a perforating injury, surgical removal, dislocation of the lens, or congenital anomaly. The management of aphakia can be either conservative or surgical. Various surgical techniques could be used, including retro pupillary-fixated iris-claw intraocular lenses (IOLs) and anterior-fixated iris-claw IOLs. One of the challenges faced by ophthalmologists is the optical rehabilitation of pediatric aphakic patients because a child's eye is still growing, resulting in fundamental variations in their refractive elements, and the immature visual system faces the risks of amblyopia development in the case of defocus or inequality of visual input between both eyes. There is also the risk of the incidence of side effects that can be accepted in adults but not in children. Finally, accurate postoperative supervision and optical rehabilitation in pediatrics will be more complex than that in adults. This review showed that it is possible to place, replace, and exchange the Artisan IOL with minor surgical trauma. Hence, this procedure can be an acceptable therapeutic method for correcting the developmental refractive changes of the growing aphakic eye. However, some worries are still caused by probable long-term side effects, including endothelial cell loss. Finally, a significant attempt at visual rehabilitation is to treat pediatric aphakia with Artisan IOL.

7.
J Clin Med ; 13(10)2024 May 15.
Article in English | MEDLINE | ID: mdl-38792454

ABSTRACT

Background: The aim of this study was to evaluate the short-term efficacy and safety of the Paul Glaucoma Implant (PGI) in pediatric eyes diagnosed with glaucoma following congenital cataract surgery (GFCS). Methods: A retrospective, single-center, descriptive study was conducted on consecutive children diagnosed with GFCS who underwent PGI implantation between July 2022 and November 2023 at the University Medical Center Mainz. The primary outcome measure was the reduction in IOP at the last follow-up visit. Results: Ten eyes of nine children were included in the study. The mean follow-up time was 7.70 ± 4.22 months (4.68-10.72 months). At the end of the study follow-up, the mean (95% CI) reduction in IOP was -14.8 ± 8.73 mmHg (-8.56 to -21.04 mmHg, p < 0.001). At the last follow-up, 30.0% (3/10) of patients achieved an IOP (intraocular pressure) of ≥6 and ≤21 mmHg with a reduction in IOP of ≥25% without treatment, while 90.0% (9/10) achieved this target IOP regardless of glaucoma medication treatment. The mean number of antiglaucoma medications was significantly reduced from 3.50 (IQR = 1) to 2.0 (IQR = 2, p = 0.01), and the visual acuity logMAR improved from 1.26 ± 0.62 to 1.03 ± 0.48 (p = 0.04). Only one eye experienced numerical hypotony (4 mmHg) without choroidal detachment or anterior chamber shallowing within the first 24 h. No other adverse events were observed during the follow-up period. Conclusions: PGI implantation significantly lowered IOP and the number of antiglaucoma eye drops with a favorable safety profile in children diagnosed with GFCS, thereby achieving a high rate of qualified surgical success in the short term.

8.
Ophthalmol Ther ; 13(7): 1955-1966, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38771460

ABSTRACT

INTRODUCTION: The purpose of our study was to compare the safety and efficacy of two scleral fixation intraocular lens (IOL) methods of four-point scleral fixation (Akreos AO60) and the Yamane technique (AcrySof MA60AC). METHODS: This prospective, randomized study was conducted at the Military Institute of Medicine-National Research Institute in Warsaw between 2021 and 2023. We compared both groups for cause of aphakia, ocular history, refractive status, and complication. RESULTS: Our study included 50 eyes from 47 patients. Four-point fixation was performed in 25 eyes (group 1), and the Yamane technique was used in 25 eyes (group 2). Surgical time was 24.1 min ± 8.9 in group 1 and 25.1 min ± 9.9 in group 2 (p > 0.05). The postoperative BCVA (best-corrected visual acuity) for group 1 and group 2 at 1 year's observation was 0.10 ± 0.15 and 0.09 ± 0.17 logMAR, respectively (p > 0.05). Postoperative total refractive error (RE) was - 0.06 ± 0.71 diopters (D) for four-point scleral fixation and 0.83 ± 0.70 D for Yamane technique (p < 0.05). Endothelial cell density (ECD) loss was 0.9% in group 1 and 3.5% in group 2 (p > 0.05). Bleeding into the anterior chamber and vitreous body was more frequent in the group of patients operated on with the use of the Yamane technique (10 cases, 20%, p = 0.01). IOL displacement was found in one case (2%) in group 2. CONCLUSIONS: Both analyzed techniques are well tolerated and ensure good refractive results (extremely predictable in four-point scleral fixation) and have a similar safety profile. Four-point scleral fixation of IOL would appear to be safe, effective and beneficial for young, active patients, especially after trauma or recurrent subluxation. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier NCT06389643.

9.
Taiwan J Ophthalmol ; 14(1): 112-116, 2024.
Article in English | MEDLINE | ID: mdl-38655000

ABSTRACT

Ocular comorbidities can happen as congenital defective gene associations. We present a 37-year-old female patient who was mentally challenged and had coexisting achromatopsia gene abnormality on genetic analysis. She was operated in childhood for congenital cataract, and posterior chamber intraocular lens (IOL) was implanted at 10 years of age elsewhere. The patient presented 27 years later with luxated IOL with endothelial decompensation. There was a coexisting steep and thin cornea noted on corneal topography. She was managed with pre-Descemet's endothelial keratoplasty with transpositioning of posterior chamber IOL to glued IOL with single-pass four-throw pupilloplasty. Postoperatively, the cornea was clear with centered glued IOL. The lesser postanesthetic challenges and faster rehabilitation are obtained in combination procedures with reduced complications in such rare scenarios.

10.
Cont Lens Anterior Eye ; 47(3): 102163, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38582614

ABSTRACT

PURPOSE: The main aim of this study was to evaluate the type, parameters, loss and complications of contact lenses (CLs) in the treatment of paediatric aphakia over a 10-year period. METHODS: This retrospective multicentre chart review included the files of aphakic CL wearers under the age of 9 years old that were treated between 2008 and 2018. Patients with traumatic aphakia and scarring of the cornea were excluded. The following data were collected; demographic data, cataract type (congenital or secondary), CL type, parameters and wearing time, reason for replacement and discontinuation of the CLs, visual acuity (VA), prophylactic use of antibiotics (ABs), and complications. RESULTS: Ninety-one aphakic children (132 eyes) were fitted with soft CLs. The median age of cataract extraction was 10.50 weeks (interquartile range (IQR) 7,15) in the congenital cataract group and 112 weeks (IQR 41,285) in the secondary cataract group. At the initial fitting a silicone elastomer CL was fitted in 86 % and a silicone hydrogel CL in 12 %, the remaining 2 % were mixed CL types. The median CL power at baseline was + 29 D (IQR 25,32) and after 3 years of wear the median power had shifted significantly to + 20 D (IQR 17,26), P < 0.001. A total of 1083 extra CL replacements were needed of which 414 in the first year of wear. Of these 414 replacements almost half (46 %;n = 191) were due to loss of the CL. Complications developed in 8 (9 %) cases and 7 (8 %) patients discontinued CL wear. CONCLUSION: This paper confirms that paediatric aphakia can be successfully treated with soft CLs with low rates of complications and discontinuation encountered. Unscheduled CL replacements due to loss are a concern, especially in the first year, and are straining for both the care giver and medical system. Attentive care and clear information is advised during the first year of CL wear.


Subject(s)
Visual Acuity , Humans , Retrospective Studies , Female , Male , Child, Preschool , Child , Visual Acuity/physiology , Infant , Netherlands/epidemiology , Contact Lenses, Hydrophilic , Aphakia, Postcataract/physiopathology , Cataract Extraction , Aphakia , Cataract/congenital
11.
Am J Ophthalmol Case Rep ; 34: 101954, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38577387

ABSTRACT

Purpose: To report the clinical course of an aphakic patient who developed positional secondary angle closure glaucoma following pars plana vitrectomy (PPV) with perfluoropropane (C3F8) gas tamponade. Observations: A 23-year-old male presented due to a two-year history of vision loss in the left eye. Best-corrected visual acuity (BCVA) was 20/200 and intraocular pressure (IOP) was 12 mm Hg OS. Exam revealed iridodonesis and aphakia of both eyes, and a total RRD in the left eye. The patient underwent scleral buckle plus PPV with 15 % C3F8 gas and was instructed to maintain face-down positioning for 5 days. On post-operative day 1, IOP was 32 mm Hg and exam revealed significant diffuse corneal edema, a large epithelial defect, and 85 % C3F8 fill of the vitreous cavity. Patient was started on IOP-lowering drops but continued to have elevated IOP and corneal epithelial sloughing over the next 3 weeks. He was taken for a superficial keratectomy, but when placed supine under the microscope, a large new gas bubble was visualized overlying the pupil in a now shallow anterior chamber (AC) and IOP was 52 mm Hg. The patient was positioned back upright and the gas bubble migrated posteriorly out of the AC with return of IOP to 25 mm Hg. The dynamic nature of his IOP raised concerns for intermittent angle closure by C3F8 induced by supine positioning. Thus, a pars plana aspiration of the C3F8 gas was performed and resulted in normalization of the IOP. Conclusions and importance: Dynamic, positional secondary angle closure glaucoma can occur after vitrectomy with C3F8 in the setting of aphakia. This is the first report to capture C3F8 gas migration causing intermittent acute angle closure in real-time. Due to its intermittent nature however, the diagnosis may not be initially apparent at the slit lamp. Thus, we suggest this potential complication should be carefully monitored for and discussed when advising post-vitrectomy positioning in aphakic patients.

12.
Saudi J Ophthalmol ; 38(1): 71-77, 2024.
Article in English | MEDLINE | ID: mdl-38628420

ABSTRACT

PURPOSE: The purpose of this study was to report visual and refractive outcomes in eyes that underwent intraocular lens (IOL) fixation in the absence of capsular support. METHODS: This was a retrospective chart review of cases undergoing posterior chamber iris-fixated IOL (IFIOL) and scleral-fixated IOL (SFIOL) implants from June 2014 to March 2020 with more than 3 months of follow-up and having a preoperative best-corrected visual acuity of 20/80 and more. RESULTS: Records of 120 eyes of 112 patients were reviewed. The mean age of the patients was 46.9 ± 22.3 (14.4-98.0) years, and 62% (n = 70) of participants were male. Most of the eyes (102: 85%) were aphakic at the time of surgery. The mean follow-up was 22.95 ± 17.1 months. The efficacy index of sutured IFIOL and glued SFIOL outperformed sutured SFIOL at 3 months and final visits postoperatively (P < 0.001). All techniques studied here resulted in a similar safety index at 3 months (P = 0.4). The mean predictive error (postoperative spherical equivalent refraction minus intended target refraction) was +0.07 ± 1.5 D and -0.12 ± 1.4 D at 3 months and the final postoperative visit, respectively. CONCLUSION: The studied techniques have relatively good visual and refractive outcomes in this series. In addition, techniques involving a small corneal incision with foldable IOL fixation to the iris or scleral tissue have superior efficacy and safety indices compared to creating large corneoscleral wounds for rigid IOL fixation techniques.

13.
Rom J Ophthalmol ; 68(1): 13-18, 2024.
Article in English | MEDLINE | ID: mdl-38617724

ABSTRACT

Aim: To compare the anatomical and functional results and patient satisfaction following retropupillary implantation of Artisan Aphakia iris-fixated intraocular lens (rAAIF) and sutured scleral fixated intraocular lens (SFIOL). Subjects and methods: We presented a prospective double-arm non-blinded study. Forty-one eyes with acquired aphakia, no age-related macular degeneration, no previous keratoplasty, no combined procedures, no AC reaction (cells, fibrin), normal intraocular pressure, no history of endothelial corneal dystrophy in relatives or fellow eye were included. Indications, complications, corrected distance visual acuity (CDVA), endothelial cell density (ECD), and patient satisfaction score were assessed. Results: Retropupillary AAIF was implanted in 21 (51.22%) eyes and SFIOL in 20 (48.78%) eyes. The most common indication was complicated cataract surgery in 18 cases (43.90%), followed by trauma in 16 (39.02%), and spontaneous dislocation in 7 (17.07%). No difference between rAAIF and SFIOL in terms of sex, laterality (χ=0.13, p=0.72), indications (χ=0.78, p=0.68), previous ocular history, and comorbidities was observed. The complications and the visual outcomes at 6 months postoperatively were similar between the two groups (p=0.95 and p=0.321, respectively). The ECD loss in the two groups was also similar (p=0.89). The patient satisfaction score was 58.67±8.80 in the rAAIF and 56.69±11.50 in the SFIOL group, which was statistically similar (p=0.764). Conclusion: Retropupillary AAIF and SFIOL showed similar results concerning visual acuity, endothelial cell loss, and patient satisfaction. Careful preoperative individual assessment is required to have optimal results with either technique. Abbreviations: AAIF = Artisan Aphakia iris-fixated intraocular lens, rAAIF = retropupillary Artisan Aphakia iris-fixated intraocular lens, CDVA = corrected distance visual acuity, ECD = endothelial cell density, IOL = intraocular lens, SD = standard deviation, SFIOL = scleral fixated intraocular lens.


Subject(s)
Aphakia , Lenses, Intraocular , Humans , Prospective Studies , Iris/surgery , Sclera/surgery
14.
Turk J Ophthalmol ; 54(2): 90-102, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38645732

ABSTRACT

Congenital cataract is among the main causes of treatable vision loss in childhood. The first weeks and months of life are a critical time for the development of vision. Therefore, early cataract surgery and effective multifaceted treatment of the resulting aphakia in the early stages of life are of great value for the management of vision development. Among the treatment models, contact lenses (CL) have an important place in infancy and early childhood up to the age of 2 years. Although good visual gains were not considered very likely, especially in unilateral aphakia, important steps have been taken in the treatment of pediatric aphakia thanks to the surgical techniques developed over time and the increasing experience with optical correction systems, especially CLs. This review examines current developments in the types of CL used in pediatric aphakia, their application features, comparison with other optical systems, the features of amblyopia treatment in the presence of CL, and the results obtained with family compliance to CL wear and occlusion therapy in the light of existing studies.


Subject(s)
Aphakia, Postcataract , Contact Lenses , Visual Acuity , Humans , Aphakia, Postcataract/therapy , Aphakia, Postcataract/physiopathology , Visual Acuity/physiology , Infant , Child, Preschool , Cataract/congenital , Cataract Extraction/methods , Amblyopia/therapy , Amblyopia/physiopathology , Aphakia , Child , Infant, Newborn
15.
Clin Exp Optom ; : 1-7, 2024 Mar 14.
Article in English | MEDLINE | ID: mdl-38484726

ABSTRACT

CLINICAL RELEVANCE: It is particularly important to perform reasonable and effective optical correction to enable visual development after primary lens removal surgery for congenital cataracts. Aphakic infants need a suitable addition power of prescription (ADD) to help them focus on close visual objects. BACKGROUND: It is challenging to obtain appropriate ADD power for infants due to poor cooperation and lack of subjective feedback. We aimed to determine the appropriate ADD for aphakic infants using a recently developed smart wearable device called Clouclip. METHODS: The study was a cross-sectional, observational pilot study. Twenty-three aphakic infants (aged from 6 months to 3.5 years) were invited to wear a smart wearable device for 7 days consecutively to monitor the near viewing distance in real life. Viewing habits and its associations with the possible influencing factors were investigated based on the data obtained from the device. RESULTS: The average proportion of near viewing time was 77.9% (95% confidence interval (CI) 72.1-83.7%). The average of the median near viewing distance was 23.8 cm (95% CI 20.6 cm-27.0 cm), which corresponded to an ADD of +4.25 D (95% CI + 3.75 D - +4.75 D) spectacle prescription. The height of the child was found to be positively correlated with the median of near viewing distance (r = 0.646, p = 0.001). Age, current ADD, age of cataract extraction surgery and bilaterality or monocularity of the aphakic eyes showed no significant correlation with the aforementioned viewing habits (all p > 0.05). CONCLUSION: By using the novel wearable device, we found the suitable ADD of spectacle prescription for aphakic infants is about +4.25 D. The height of the child was an influencing factor for ADD.

17.
Acta Ophthalmol ; 102(5): e805-e812, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38292001

ABSTRACT

PURPOSE: The purpose of this study was to compare the tilt and decentration of one-piece anti-vaulting haptic intraocular lenses (IOL) and three-piece C-loop haptic IOLs in paediatric eyes undergoing secondary IOL implantation into the ciliary sulcus. METHODS: Paediatric aphakic patients receiving either one-piece anti-vaulting haptic or three-piece C-loop haptic IOL implants into the ciliary sulcus were enrolled in this prospective non-randomized interventional study and followed up for 3 years. IOL decentration and tilt were measured using Scheimpflug images. Preoperative and postoperative information, including demographic data and ocular biometric parameters and complications, were collected and analysed. RESULTS: Among 123 eyes of 79 paediatric patients, there were 72 eyes (58.54%) in the anti-vaulting haptic IOL group and 51 eyes (41.46%) in the C-loop haptic group. The anti-vaulting haptic IOL group had a lower incidence of clinically significant vertical IOL decentration than the C-loop haptic IOL group (23.88% vs. 43.14%, p = 0.037). No intergroup differences were observed in vertical or horizontal tilt or in horizontal decentration (all p > 0.05). One-piece anti-vaulting haptic IOL implantation was associated with a lower risk of clinically significant vertical decentration than three-piece C-loop haptic IOL implantation (odds ratio: 0.42, p = 0.037). There was a higher incidence of IOL dislocation in the C-loop haptic IOL group (15.22% vs. 4.17%, p = 0.046). CONCLUSIONS: In paediatric aphakic eyes undergoing secondary IOL implantation into the ciliary sulcus, one-piece anti-vaulting haptic IOLs can reduce the risk of clinically significant vertical IOL decentration compared with three-piece C-loop haptic IOLs and may favour long-term IOL positional stability.


Subject(s)
Ciliary Body , Lens Implantation, Intraocular , Lenses, Intraocular , Prosthesis Design , Visual Acuity , Humans , Prospective Studies , Male , Female , Lenses, Intraocular/adverse effects , Child, Preschool , Follow-Up Studies , Ciliary Body/surgery , Lens Implantation, Intraocular/methods , Child , Aphakia, Postcataract/physiopathology , Aphakia, Postcataract/surgery , Artificial Lens Implant Migration/diagnosis , Artificial Lens Implant Migration/etiology , Artificial Lens Implant Migration/prevention & control , Artificial Lens Implant Migration/physiopathology , Infant , Refraction, Ocular/physiology , Postoperative Complications/epidemiology , Time Factors
18.
International Eye Science ; (12): 469-472, 2024.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-1011403

ABSTRACT

AIM: To observe the clinical efficacy of 8-0 polypropylene scleral-sutured fixed intraocular lens(IOL)suspension implantation with the double knots technique in aphakic eyes.METHODS: Retrospective case series study. The data of 30 aphakic cases(31 eyes, 22 males)that underwent IOL suspension in our hospital from January 2021 to November 2022 were collected. The suspension of IOL(AcrySof IQ or Tecnis ZCB00)was performed by 8-0 polypropylene scleral-sutured with the double knots technique. The visual acuity, intraocular pressure(IOP), IOL position and complications with at least 6 mo of follow-up were observed.RESULTS: The mean preoperative uncorrected visual acuity(UCVA, LogMAR)and best-corrected visual acuity(BCVA, LogMAR)were 2.53±0.78 and 0.35±0.26, respectively, which were 0.58±0.26 and 0.36±0.27 at 6 mo postoperatively, respectively. And the differences in UCVA were statistically significant(t=15.408, P&#x003C;0.01), whereas the difference in BCVA was not(t=-1.677, P=0.104). There were no intraoperative complications, with IOL position all centered, but 3 eyes had IOL tilt, 2 eyes had intraocular hypertension, 5 eyes had corneal edema, and 1 eye had suture exposure postoperatively. There were no complications such as hyphema, vitreous hemorrhage, macular edema, corneal endothelial decompensation, hypotony, choroidal detachment, retinal detachment, fulminant superior choroidal hemorrhage, endophthalmitis, or others.CONCLUSION: The 8-0 polypropylene scleral-sutured fixed intraocular lens suspension implantation with the double knots technique can improve the postoperative visual acuity of aphakic patients, and fewer complications, which is an option for the treatment of aphakia, dislocation of the lens and ligament abnormalities.

19.
BMC Ophthalmol ; 23(1): 493, 2023 Dec 06.
Article in English | MEDLINE | ID: mdl-38053049

ABSTRACT

BACKGROUND: Sutureless scleral fixed intraocular lens implantation (SF-IOL) has become one of the mainstream schemes in clinical treatment of aphakic eyes because of its advantages, such as avoiding dislocation of intraocular lens or subluxation caused by suture degradation or fracture and significant improvement of postoperative visual acuity. However, a consensus on the relative effectiveness and safety of this operation and other methods is still lacking. This study aimed to compare the efficacy and safety of sutureless SF-IOL with other methods. Aphakia means that the lens leaves the normal position and loses its original function, including absence or complete dislocation and subluxation of the lens which could cause anisometropic amblyopia, strabismus, and loss of binocular function in children and adolescents. For adults, the loss of the lens could lead to high hyperopia and affect vision. Above all this disease can seriously affect the quality of life of patients. METHODS: Literature about sutureless SF-IOL in PubMed, Cochrane Library, Embase, Web of Science, China National Knowledge Infrastructure, China Technical Journal VIP database, and Wanfang database published from 2000 to 2022 was reviewed. The weighted average difference was calculated by RevMan5.3 software for analysis. Two researchers independently selected the study and used the Cochrane collaboration tool to assess the risk of errors. Cochrane bias risk tool was used to evaluate the quality of evidence. This study is registered on PROSPERO (CRD42022363282). RESULTS: The postoperative IOL-related astigmatism of sutureless SF-IOL was lower than that of suture SF-IOL, and there was statistical difference when we compared the absolute postoperative spherical equivalent after sutureless SF-IOL and suture SF-IOL. Indicating that the degree of refractive error after sutureless SF-IOL was lower. Meanwhile, the operation time of sutureless SF-IOL was shorter than that of suture SF-IOL. The subgroup analysis showed that the absolute postoperative spherical equivalent and astigmatism values in Yamane technique were lower than those in suture SF-IOL. CONCLUSION: Sutureless SF-IOL has the advantages of stable refraction, short operation time, and less postoperative complications. However, high-quality literature to compare these technologies is lacking. Some long-term follow-up longitudinal prospective studies are needed to confirm the findings.


Subject(s)
Aphakia , Astigmatism , Lenses, Intraocular , Adolescent , Adult , Child , Humans , Aphakia/surgery , Lens Implantation, Intraocular/methods , Postoperative Complications/surgery , Quality of Life , Retrospective Studies , Sclera/surgery , Suture Techniques
20.
J Binocul Vis Ocul Motil ; 73(4): 97-98, 2023 Oct 02.
Article in English | MEDLINE | ID: mdl-37931123

ABSTRACT

Infantile cataract is one of the major causes of visual impairment in children. This article will discuss some of the techniques, challenges, complications, and compliance issues with aphakic contact lenses.


Subject(s)
Aphakia, Postcataract , Cataract Extraction , Cataract , Contact Lenses , Vision, Low , Child , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...