Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
JACC Case Rep ; 13: 101805, 2023 May 03.
Article in English | MEDLINE | ID: mdl-37077757

ABSTRACT

Tricuspid valve (TV) surgery carries a high risk of atrioventricular block. In this report, we illustrate several options for managing conduction disorders after TV surgery. The choice of cardiac implantable devices must take account of several parameters such as surgical procedure, patient's rhythm and history, and etiology of TV disease. (Level of Difficulty: Intermediate.).

2.
Front Cardiovasc Med ; 10: 1135233, 2023.
Article in English | MEDLINE | ID: mdl-36998976

ABSTRACT

Introduction: Cardiac lymphoma is a rare but serious disease that is usually located in the right heart. The symptoms (dyspnea, respiratory distress, fatigue, syncope…) are not specific and depend on the mass location. Cardiac magnetic resonance has a crucial role in the diagnostic strategy but biopsy is mandatory to confirm the diagnosis. Case presentation: We report the case of a 63-yeart old man who presented with severe dyspnea and complete atrioventricular block (AVB). A bulky and invasive mass was found in the left atrium extending to the right atrium through the interatrial septum. A cardiac lymphoma was suspected by cardiac magnetic resonance (CMR) imaging and confirmed by transvenous biopsy. The patient was treated with urgent chemotherapy (R-CHOP) and pacemaker implantation. After 4 cycles of R-CHOP the patient was in complete remission with total disappearance of the mass and return of a spontaneous sinus rhythm. Conclusion: lymphoma is a therapeutic emergency as appropriate treatment can lead to complete remission even when the mass is extensive and invasive. Complete AVB is a potentially reversible complication of cardiac lymphoma, and the decision to implant a pacemaker must be carefully weighed.

3.
Front Cardiovasc Med ; 8: 665029, 2021.
Article in English | MEDLINE | ID: mdl-33996948

ABSTRACT

This study assessed the basic working principle to measure aortic annulus resistance during balloon inflation for transcatheter aortic valve implantation (TAVI), by acquisition of pressure-volume curve for a guided semi-automatic implantation. A modular bench-system was used which allows the incremental inflation of valvuloplasty balloons by means of a stepper-motor driven linear axis with simultaneous recording of the pressure changes inside the system. Different porcine aortic xenografts were assessed by use of a non-compliant valvuloplasty balloon. In a second step transcatheter aortic stents were implanted inside target sized xenografts. The recorded pressure volume-curves showed that the system can accurately differentiate between different xenografts and assess the quality of the tissue rendering real-time analysis of pressure-volume curves during balloon-inflation possible, which has the potential to optimize the implantation procedure by direct adaptation to the patient specific anatomy and characteristics. Further investigations and development are warranted.

4.
J Cardiovasc Electrophysiol ; 29(1): 167-176, 2018 01.
Article in English | MEDLINE | ID: mdl-29044787

ABSTRACT

INTRODUCTION: Radiofrequency (RF) ablation is effective for slow pathway ablation, but carries a risk of inadvertent AV block requiring permanent pacing. By comparison, cryoablation with a 4-mm distal electrode catheter has not been reported to cause permanent AV block but has been shown to be less effective than RF ablation. We sought to define the safety and efficacy of a 6-mm distal electrode cryoablation catheter for slow pathway ablation in patients with atrioventricular nodal reentry tachycardia (AVNRT). METHODS AND RESULTS: Twenty-six U.S. and eight Canadian centers participated in the study. Patients with supraventricular tachycardia (SVT) thought likely to be AVNRT were enrolled. If AVNRT was inducible and confirmed to be the clinical SVT, then the slow pathway was targeted with a cryoablation catheter using a standardized protocol of best practices. Acute success was defined as inducibility of no more than one echo beat after cryoablation. Primary efficacy was defined as acute success and the absence of documented recurrent AVNRT over 6 months of follow-up. Primary safety was a composite of serious procedure-related adverse events and/or device-related complications. Note that 397 subjects met enrollment criteria after the EP study and received cryoablation. Mean ablation procedure duration (including a waiting period) was 89 ± 40 minutes, and mean fluoroscopy time was 4.8 ± 5.9 minutes. Isoproterenol was administered before cryoablation in 53% and after the last lesion in 85% of cases. Acute procedural success was realized in 95% (378 of 397) of subjects. No subject received a permanent pacemaker due to AV block. The slow pathway could not be ablated in 19 subjects, including: 12 due to inefficacy, 2 due to transient AV block, and 5 due to both inefficacy and transient AV block. RF ablation was used in the same procedure in 11 of 19 failed subjects, and was ineffective in 3 subjects. Among the group with acute success, 10 subjects (2.7%) had documented recurrent AVNRT over the 6-month follow-up period, and all occurred within 3 months of the index cryoablation. Serious procedure-related adverse events occurred in 4 subjects (1.0%), including one each: tamponade, pulmonary embolism, femoral vein hemorrhage, and diagnostic EP catheter knotting. None of these serious adverse events were related to use of the cryoablation catheter. Overall, 93% of subjects had successful slow pathway ablation at 6 months with the study cryoablation catheter. CONCLUSIONS: Cryoablation for AVNRT using a focal 6-mm catheter was safe and effective. It resulted in a low risk of recurrence over 6 months of follow-up with no incidence of AV block requiring permanent pacing.


Subject(s)
Cardiac Catheterization/instrumentation , Cardiac Catheters , Cryosurgery/instrumentation , Heart Conduction System/surgery , Tachycardia, Atrioventricular Nodal Reentry/surgery , Tachycardia, Supraventricular/surgery , Action Potentials , Adult , Aged , Atrioventricular Block/etiology , Atrioventricular Block/physiopathology , Cardiac Catheterization/adverse effects , Cryosurgery/adverse effects , Equipment Design , Female , Heart Conduction System/physiopathology , Heart Rate , Humans , Male , Middle Aged , North America , Prospective Studies , Recurrence , Risk Factors , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/physiopathology , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Time Factors , Treatment Outcome
5.
Korean Circ J ; 46(2): 260-3, 2016 Mar.
Article in English | MEDLINE | ID: mdl-27014358

ABSTRACT

We described a case of a 54-year-old male who presented with dizziness and dyspnea due to cardiac metastasis of leiomyosarcoma. Cardiac metastasis of leiomyosarcoma caused both bradyarrhythmia and tachyarrhythmia in the patient. He was treated with implantation of a permanent pacemaker for management of complete atrio-ventricular block and anti-arrhythmic drug that suppressed ventricular tachycardia successfully.

6.
Korean Circulation Journal ; : 260-263, 2016.
Article in English | WPRIM (Western Pacific) | ID: wpr-221719

ABSTRACT

We described a case of a 54-year-old male who presented with dizziness and dyspnea due to cardiac metastasis of leiomyosarcoma. Cardiac metastasis of leiomyosarcoma caused both bradyarrhythmia and tachyarrhythmia in the patient. He was treated with implantation of a permanent pacemaker for management of complete atrio-ventricular block and anti-arrhythmic drug that suppressed ventricular tachycardia successfully.


Subject(s)
Humans , Male , Middle Aged , Bradycardia , Dizziness , Dyspnea , Heart , Leiomyosarcoma , Neoplasm Metastasis , Tachycardia , Tachycardia, Ventricular
7.
J Electrocardiol ; 47(5): 734-7, 2014.
Article in English | MEDLINE | ID: mdl-25060130

ABSTRACT

Vagally mediated paroxysmal atrial fibrillation is typically described to occur in otherwise healthy young-to-middle aged males during periods of high vagal tone. We report a case of cardioinhibitory type neurocardiogenic syncope associated with atrial fibrillation in an elderly female during episodes of nausea. This was replicated during tilt-table testing. The atrial fibrillation was part of a unique snap shot of the entire electrophysiological spectrum of the vagal response captured in detail in this index patient.


Subject(s)
Atrial Fibrillation/diagnosis , Atrial Fibrillation/physiopathology , Electrocardiography , Syncope, Vasovagal/diagnosis , Syncope, Vasovagal/physiopathology , Aged , Female , Humans , Recurrence , Tilt-Table Test
SELECTION OF CITATIONS
SEARCH DETAIL
...