Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 429
Filter
1.
Resusc Plus ; 19: 100665, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38974929

ABSTRACT

Aim: Compare heart rate assessment methods in the delivery room on newborn clinical outcomes. Methods: A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283438) Study Selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence. Results: Two randomized controlled trials involving 91 newborns and 1 nonrandomized study involving 632 newborns comparing electrocardiogram (ECG) to auscultation plus pulse oximetry were included. No studies were found that compared any other heart rate measurement methods and reported clinical outcomes. There was no difference between the ECG and control group for duration of positive pressure ventilation, time to heart rate ≥ 100 beats per minute, epinephrine use or death before discharge. In the randomized studies, there was no difference in rate of tracheal intubation [RR 1.34, 95% CI (0.69-2.59)]. No participants received chest compressions. In the nonrandomized study, fewer infants were intubated in the ECG group [RR 0.75, 95% CI (0.62-0.90)]; however, for chest compressions, benefit or harm could not be excluded. [RR 2.14, 95% (CI 0.98-4.70)]. Conclusion: There is insufficient evidence to ascertain clinical benefits or harms associated with the use of ECG versus pulse oximetry plus auscultation for heart rate assessment in newborns in the delivery room.

2.
Front Glob Womens Health ; 5: 1385343, 2024.
Article in English | MEDLINE | ID: mdl-38979032

ABSTRACT

Background: Electronic fetal heart rate monitoring (EFM) has been widely used in obstetric practice for over 40 years to improve perinatal outcomes. Its popularity is growing in Ethiopia and other sub-Saharan African countries to reduce high perinatal morbidity and mortality rates. However, its impact on delivery mode and perinatal outcomes in low-risk pregnancies remains controversial. This study aimed to assess the effect of continuous EFM on delivery mode and neonatal outcomes among low-risk laboring mothers at Debre Markos Comprehensive Specialized Hospital, Northwest Ethiopia. Methods: A prospective follow-up study was conducted from November 20, 2023, to January 10, 2024. All low-risk laboring mothers meeting the inclusion criteria were included. Data were collected via pretested structured questionnaires and observation, then analyzed using Epi-data 4.6 and SPSS. The incidences of cesarean delivery and continuous EFM were compared using the chi-squared test and Fisher's exact test. Results: The study found higher rates of instrumental-assisted vaginal delivery (7% vs. 2.4%) and cesarean sections (16% vs. 2%) due to unsettling fetal heart rate patterns in the continuous EFM group compared to the intermittent auscultation group. However, there were no differences in immediate neonatal outcomes between the groups. Conclusion: When compared to intermittent auscultation with a Pinard fetoscope, the routine use of continuous EFM among low-risk laboring mothers was associated with an increased risk of cesarean sections and instrumental vaginal deliveries, without significantly improving immediate newborn outcomes. However, it is important to note that our study faced significant logistical constraints due to the limited availability of EFM devices, which influenced our ability to use EFM comprehensively. Given these limitations, we recommend avoiding the routine use of continuous EFM for low-risk laboring mothers to help reduce the rising number of operative deliveries, particularly cesarean sections. Our findings should be interpreted with caution, and further research with adequate resources is needed to draw definitive conclusions.

3.
Sex Reprod Healthc ; 41: 101006, 2024 Jul 06.
Article in English | MEDLINE | ID: mdl-38986340

ABSTRACT

OBJECTIVE: To describe intrapartum fetal monitoring methods used in all births in Norway in 2019-2020, assess adherence to national guidelines, investigate variation by women's risk status, and explore associations influencing monitoring practices. METHODS: A nationwide population-based study. We collected data about all pregnancies with a gestational age ≥ 22 weeks during 2019-2020 from the Medical Birth Registry of Norway. We used descriptive analyses, stratified for risk status, to examine fetal monitoring methods used in all deliveries. Univariable and multivariable logistic regression models were used to determine factors associated with monitoring with cardiotocography (CTG) in low-risk, straightforward births. RESULTS: In total, 14 285 (14%) deliveries were monitored with only intermittent auscultation (IA), 46214 (46%) with only CTG, and 33417 (34%) with IA and CTG combined. Four percent (2 067/50 533) of women with risk factors were monitored with IA only. Half (10589/21 282) of the low-risk women with straightforward births were monitored with CTG. Maternal and fetal characteristics, size of the birth unit and regional practices influenced use of CTG monitoring in this group. CONCLUSIONS: Most births are monitored with CTG only, or combined with IA. Half the women with low-risk pregnancies and straightforward births were monitored with CTG although national guidelines recommending IA.

4.
Animals (Basel) ; 14(12)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38929440

ABSTRACT

BACKGROUND: Heart murmurs in puppies can be innocent or pathologic; the latter is almost always related to a congenital heart disease. Differentiating between these murmurs can be challenging for practicing veterinarians, but this differentiation is essential to ensure the best prognosis for puppies having a congenital heart disease. Our study aimed to reveal how veterinarians manage puppies with a heart murmur. METHODS: A web-based questionnaire was sent to Dutch and Belgian veterinary practices. RESULTS: Data from 452 respondents were analyzed. Though 88% of the respondents find detecting a heart murmur easy, only 9% find differentiating innocent murmurs from pathologic murmurs in puppies easy. Of the respondents, only 80% recommend immediate additional examination when detecting a loud heart murmur during the first veterinary health check at 6 weeks of age. Most of the respondents are aware that normal growth and the absence of clinical signs do not exclude severe congenital heart disease. Of the respondents, 31% were uncertain whether early surgical intervention could lead to improved outcomes. CONCLUSIONS: Veterinarians are aware of the importance of echocardiography for puppies with a loud heart murmur, and recognize their limitations when differentiating an innocent from a pathological heart murmur in a puppy.

5.
Nurse Educ Pract ; 78: 104016, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38889525

ABSTRACT

AIM: This study evaluated the effect of simulation on auscultation skills, self-confidence and anxiety levels. BACKGROUND: Auscultation is an essential topic in nursing education and patient care. Simulation is efficacious in improving auscultation skills and self-confidence and reducing anxiety levels. It is a valuable educational approach whose effects should be evaluated and disseminated in the context of auscultation. DESIGN: This study had a randomised controlled trial design. METHODS: The study was conducted with second-year nursing students enrolled at a university in Turkey. One group of students studied auscultation of heart, lung and bowel sounds with a simulated patient (n = 28), the second group with a high fidelity simulator (n = 30) and the third group with traditional education (n = 28). Data were collected using a demographic information form, auscultation control list and Nursing Anxiety and Self-Confidence with Clinical Decision Making Scale. The students' psychomotor auscultation skills, self-confidence and anxiety levels were evaluated. Data on auscultation skills were assessed after the intervention, while data on self-confidence and anxiety levels were collected at baseline, after the intervention and after clinical practices throughout the academic year. RESULTS: Anxiety and self-confidence levels showed statistically significant differences in intragroup evaluation. The self-confidence levels of the groups working with simulation did not change much in the follow-up test conducted after the end of clinical practices. The mean skill scores in the auscultation control list showed a statistically significant difference between the groups. CONCLUSIONS: Simulation and traditional approaches are effective in learning auscultation skills. However, the positive effects of simulation, particularly in enhancing students' self-confidence and reducing anxiety levels, appear to be more permanent and impactful than traditional education. Therefore, it is recommended that simulation be prioritized for teaching auscultation skills.


Subject(s)
Anxiety , Auscultation , Clinical Competence , Education, Nursing, Baccalaureate , Students, Nursing , Humans , Students, Nursing/psychology , Students, Nursing/statistics & numerical data , Clinical Competence/standards , Female , Anxiety/diagnosis , Male , Turkey , Self Concept , Young Adult , Simulation Training/methods , Adult , Patient Simulation
6.
Resusc Plus ; 19: 100668, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38912532

ABSTRACT

Aim: To examine speed and accuracy of newborn heart rate measurement by various assessment methods employed at birth. Methods: A search of Medline, SCOPUS, CINAHL and Cochrane was conducted between January 1, 1946, to until August 16, 2023. (CRD 42021283364) Study selection was based on predetermined criteria. Reviewers independently extracted data, appraised risk of bias and assessed certainty of evidence. Results: Pulse oximetry is slower and less precise than ECG for heart rate assessment. Both auscultation and palpation are imprecise for heart rate assessment. Other devices such as digital stethoscope, Doppler ultrasound, an ECG device using dry electrodes incorporated in a belt, photoplethysmography and electromyography are studied in small numbers of newborns and data are not available for extremely preterm or bradycardic newborns receiving resuscitation. Digital stethoscope is fast and accurate. Doppler ultrasound and dry electrode ECG in a belt are fast, accurate and precise when compared to conventional ECG with gel adhesive electrodes. Limitations: Certainty of evidence was low or very low for most comparisons. Conclusion: If resources permit, ECG should be used for fast and accurate heart rate assessment at birth. Pulse oximetry and auscultation may be reasonable alternatives but have limitations. Digital stethoscope, doppler ultrasound and dry electrode ECG show promise but need further study.

7.
JMIR Cardio ; 8: e57111, 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38924781

ABSTRACT

BACKGROUND: Heart failure (HF) contributes greatly to morbidity, mortality, and health care costs worldwide. Hospital readmission rates are tracked closely and determine federal reimbursement dollars. No current modality or technology allows for accurate measurement of relevant HF parameters in ambulatory, rural, or underserved settings. This limits the use of telehealth to diagnose or monitor HF in ambulatory patients. OBJECTIVE: This study describes a novel HF diagnostic technology using audio recordings from a standard mobile phone. METHODS: This prospective study of acoustic microphone recordings enrolled convenience samples of patients from 2 different clinical sites in 2 separate areas of the United States. Recordings were obtained at the aortic (second intercostal) site with the patient sitting upright. The team used recordings to create predictive algorithms using physics-based (not neural networks) models. The analysis matched mobile phone acoustic data to ejection fraction (EF) and stroke volume (SV) as evaluated by echocardiograms. Using the physics-based approach to determine features eliminates the need for neural networks and overfitting strategies entirely, potentially offering advantages in data efficiency, model stability, regulatory visibility, and physical insightfulness. RESULTS: Recordings were obtained from 113 participants. No recordings were excluded due to background noise or for any other reason. Participants had diverse racial backgrounds and body surface areas. Reliable echocardiogram data were available for EF from 113 patients and for SV from 65 patients. The mean age of the EF cohort was 66.3 (SD 13.3) years, with female patients comprising 38.3% (43/113) of the group. Using an EF cutoff of ≤40% versus >40%, the model (using 4 features) had an area under the receiver operating curve (AUROC) of 0.955, sensitivity of 0.952, specificity of 0.958, and accuracy of 0.956. The mean age of the SV cohort was 65.5 (SD 12.7) years, with female patients comprising 34% (38/65) of the group. Using a clinically relevant SV cutoff of <50 mL versus >50 mL, the model (using 3 features) had an AUROC of 0.922, sensitivity of 1.000, specificity of 0.844, and accuracy of 0.923. Acoustics frequencies associated with SV were observed to be higher than those associated with EF and, therefore, were less likely to pass through the tissue without distortion. CONCLUSIONS: This work describes the use of mobile phone auscultation recordings obtained with unaltered cellular microphones. The analysis reproduced the estimates of EF and SV with impressive accuracy. This technology will be further developed into a mobile app that could bring screening and monitoring of HF to several clinical settings, such as home or telehealth, rural, remote, and underserved areas across the globe. This would bring high-quality diagnostic methods to patients with HF using equipment they already own and in situations where no other diagnostic and monitoring options exist.

8.
Postgrad Med ; 136(4): 417-421, 2024 May.
Article in English | MEDLINE | ID: mdl-38805321

ABSTRACT

OBJECTIVE: This study aimed to assess physicians' approach to cardiac murmurs and their level of knowledge about this sign, which is a crucial finding in childhood cardiac anomalies. METHODS: The study intended to include all family physicians in the Adiyaman province of Turkey, but ultimately 150 out of 210 physicians participated and was completed with a percentage response rate of 71%. Participants were asked about their approach to cardiac murmurs, answered knowledge questions, and completed a questionnaire on demographic characteristics. Subsequently, eight heart sounds were played, and participants were asked to identify the nature of each sound. RESULTS: Family medicine specialists (all scores were p < 0.001) and physicians who completed a pediatric internship lasting over a month (knowledge score p = 0.012, behavioral score p = 0.021, recording score p = 0.01) demonstrated significantly higher knowledge, approach, and recording scores. Age and years in the profession showed a negative correlation with recording scores. CONCLUSIONS: The study highlights the significant impact of various factors such as gender, specialization, internship duration, experience, and theoretical knowledge on the ability to recognize and approach cardiac murmurs. These findings underscore the importance of incorporating these factors into medical education and development programs, especially those aimed at improving cardiac examination skills.


Subject(s)
Clinical Competence , Heart Murmurs , Humans , Male , Female , Heart Murmurs/diagnosis , Turkey , Adult , Surveys and Questionnaires , Child , Middle Aged , Health Knowledge, Attitudes, Practice
9.
BMC Med Educ ; 24(1): 560, 2024 May 23.
Article in English | MEDLINE | ID: mdl-38783278

ABSTRACT

BACKGROUND: Cardiac auscultation is an efficient and effective diagnostic tool, especially in low-income countries where access to modern diagnostic methods remains difficult. This study aimed to evaluate the effect of a digitally enhanced cardiac auscultation learning method on medical students' performance and satisfaction. METHODS: We conducted a double-arm parallel controlled trial, including newly admitted 4th -year medical students enrolled in two medical schools in Yaoundé, Cameroon and allocated into two groups: the intervention group (benefiting from theoretical lessons, clinical internship and the listening sessions of audio recordings of heart sounds) and the control group (benefiting from theoretical lessons and clinical internship). All the participants were subjected to a pretest before the beginning of the training, evaluating theoretical knowledge and recognition of cardiac sounds, and a post-test at the eighth week of clinical training associated with the evaluation of satisfaction. The endpoints were the progression of knowledge score, skills score, total (knowledge and skills) score and participant satisfaction. RESULTS: Forty-nine participants (27 in the intervention group and 22 in the control group) completed the study. The knowledge progression (+ 26.7 versus + 7.5; p ˂0.01) and the total progression (+ 22.5 versus + 14.6; p ˂ 0.01) were higher in the intervention group with a statistically significant difference compared to the control group. There was no significant difference between the two groups regarding skills progression (+ 25 versus + 17.5; p = 0.27). Satisfaction was higher in general in the intervention group (p ˂ 0.01), which recommended this method compared to the control group. CONCLUSION: The learning method of cardiac auscultation reinforced by the listening sessions of audio recordings of heart sounds improves medical students' performances (knowledge and global - knowledge and skills) who find it satisfactory and recommendable. TRIAL REGISTRATION: This trial has been registered the 29/11/2019 in the Pan African Clinical Trials Registry ( http://www.pactr.org ) under unique identification number PACTR202001504666847 and the protocol has been published in BMC Medical Education.


Subject(s)
Clinical Competence , Heart Auscultation , Students, Medical , Humans , Cameroon , Male , Female , Educational Measurement/methods , Education, Medical, Undergraduate/methods , Young Adult , Computer-Assisted Instruction/methods
10.
PeerJ ; 12: e17368, 2024.
Article in English | MEDLINE | ID: mdl-38803582

ABSTRACT

Objective: During the COVID-19 pandemic, universal mask-wearing became one of the main public health interventions. Because of this, most physical examinations, including lung auscultation, were done while patients were wearing surgical face masks. The aim of this study was to investigate whether mask wearing has an impact on pulmonologist assessment during auscultation of the lungs. Methods: This was a repeated measures crossover design study. Three pulmonologists were instructed to auscultate patients with previously verified prolonged expiration, wheezing, or crackles while patients were wearing or not wearing masks (physician and patients were separated by an opaque barrier). As a measure of pulmonologists' agreement in the assessment of lung sounds, we used Fleiss kappa (K). Results: There was no significant difference in agreement on physician assessment of lung sounds in all three categories (normal lung sound, duration of expiration, and adventitious lung sound) whether the patient was wearing a mask or not, but there were significant differences among pulmonologists when it came to agreement of lung sound assessment. Conclusion: Clinicians and health professionals are safer from respiratory infections when they are wearing masks, and patients should be encouraged to wear masks because our research proved no significant difference in agreement on pulmonologists' assessment of auscultated lung sounds whether or not patients wore masks.


Subject(s)
Auscultation , COVID-19 , Cross-Over Studies , Masks , Respiratory Sounds , SARS-CoV-2 , Humans , Masks/adverse effects , COVID-19/prevention & control , COVID-19/diagnosis , Auscultation/methods , Male , Female , Middle Aged , Adult , Pandemics/prevention & control , Pulmonologists , Aged
11.
JMIR Pediatr Parent ; 7: e52540, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38602309

ABSTRACT

Background: The use of a smartphone built-in microphone for auscultation is a feasible alternative to the use of a stethoscope, when applied by physicians. Objective: This cross-sectional study aims to assess the feasibility of this technology when used by parents-the real intended end users. Methods: Physicians recruited 46 children (male: n=33, 72%; age: mean 11.3, SD 3.1 y; children with asthma: n=24, 52%) during medical visits in a pediatric department of a tertiary hospital. Smartphone auscultation using an app was performed at 4 locations (trachea, right anterior chest, and right and left lung bases), first by a physician (recordings: n=297) and later by a parent (recordings: n=344). All recordings (N=641) were classified by 3 annotators for quality and the presence of adventitious sounds. Parents completed a questionnaire to provide feedback on the app, using a Likert scale ranging from 1 ("totally disagree") to 5 ("totally agree"). Results: Most recordings had quality (physicians' recordings: 253/297, 85.2%; parents' recordings: 266/346, 76.9%). The proportions of physicians' recordings (34/253, 13.4%) and parents' recordings (31/266, 11.7%) with adventitious sounds were similar. Parents found the app easy to use (questionnaire: median 5, IQR 5-5) and were willing to use it (questionnaire: median 5, IQR 5-5). Conclusions: Our results show that smartphone auscultation is feasible when performed by parents in the clinical context, but further investigation is needed to test its feasibility in real life.

12.
Respir Res ; 25(1): 177, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38658980

ABSTRACT

BACKGROUND: Computer Aided Lung Sound Analysis (CALSA) aims to overcome limitations associated with standard lung auscultation by removing the subjective component and allowing quantification of sound characteristics. In this proof-of-concept study, a novel automated approach was evaluated in real patient data by comparing lung sound characteristics to structural and functional imaging biomarkers. METHODS: Patients with cystic fibrosis (CF) aged > 5y were recruited in a prospective cross-sectional study. CT scans were analyzed by the CF-CT scoring method and Functional Respiratory Imaging (FRI). A digital stethoscope was used to record lung sounds at six chest locations. Following sound characteristics were determined: expiration-to-inspiration (E/I) signal power ratios within different frequency ranges, number of crackles per respiratory phase and wheeze parameters. Linear mixed-effects models were computed to relate CALSA parameters to imaging biomarkers on a lobar level. RESULTS: 222 recordings from 25 CF patients were included. Significant associations were found between E/I ratios and structural abnormalities, of which the ratio between 200 and 400 Hz appeared to be most clinically relevant due to its relation with bronchiectasis, mucus plugging, bronchial wall thickening and air trapping on CT. The number of crackles was also associated with multiple structural abnormalities as well as regional airway resistance determined by FRI. Wheeze parameters were not considered in the statistical analysis, since wheezing was detected in only one recording. CONCLUSIONS: The present study is the first to investigate associations between auscultatory findings and imaging biomarkers, which are considered the gold standard to evaluate the respiratory system. Despite the exploratory nature of this study, the results showed various meaningful associations that highlight the potential value of automated CALSA as a novel non-invasive outcome measure in future research and clinical practice.


Subject(s)
Biomarkers , Cystic Fibrosis , Respiratory Sounds , Humans , Cross-Sectional Studies , Male , Female , Prospective Studies , Adult , Cystic Fibrosis/physiopathology , Cystic Fibrosis/diagnostic imaging , Young Adult , Adolescent , Auscultation/methods , Tomography, X-Ray Computed/methods , Lung/diagnostic imaging , Lung/physiopathology , Child , Proof of Concept Study , Diagnosis, Computer-Assisted/methods , Middle Aged
13.
Int J Med Educ ; 15: 37-43, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38581237

ABSTRACT

Methods:   A pilot randomized controlled trial was conducted at our institution's simulation center with 32 first year medical students from a single medical institution. Participants were randomly divided into two equal groups and completed an educational module the identification and pathophysiology of five common cardiac sounds. The control group utilized traditional education methods, while the interventional group incorporated multisensory stimuli. Afterwards, participants listened to randomly selected cardiac sounds and competency data was collected through a multiple-choice post-assessment in both groups. Mann-Whitney U test was used to analyze the data. Results: Data were analyzed using the Mann-Whitney U test. Diagnostic accuracy was significantly higher in the multisensory group (Mdn=100%) compared to the control group (Mdn=60%) on the post-assessment (U=73.5, p<0.042). Likewise, knowledge acquisition was substantially better in the multisensory group (Mdn=80%) than in the control group (Mdn=50%) (U= 49, p<0.031). Conclusions: These findings suggest the incorporation of multisensory stimuli significantly improves cardiac auscultation competency. Given its cost-effectiveness and simplicity, this approach offers a viable alternative to more expensive simulation technologies like the Harvey simulator, particularly in settings with limited resources. Consequently, this teaching modality holds promise for global applicability, addressing the worldwide deterioration in cardiac auscultation skills and potentially leading to better patient outcomes. Future studies should broaden the sample size, span multiple institutions, and investigate long-term retention rates.


Subject(s)
Heart Sounds , Students, Medical , Humans , Heart Auscultation , Clinical Competence , Heart Sounds/physiology , Educational Measurement/methods
14.
Front Cardiovasc Med ; 11: 1372543, 2024.
Article in English | MEDLINE | ID: mdl-38628311

ABSTRACT

Background: Auscultatory features of heart sounds (HS) in patients with heart failure (HF) have been studied intensively. Recent developments in digital and electrical devices for auscultation provided easy listening chances to recognize peculiar sounds related to diastolic HS such as S3 or S4. This study aimed to quantitatively assess HS by acoustic measures of intensity (dB) and audio frequency (Hz). Methods: Forty consecutive patients aged between 46 and 87 years (mean age, 74 years) with chronic cardiovascular disease (CVD) were enrolled in the present study after providing written informed consent during their visits to the Kitasato University Outpatient Clinic. HS were recorded at the fourth intercostal space along the left sternal border using a highly sensitive digital device. Two consecutive heartbeats were quantified on sound intensity (dB) and audio frequency (Hz) at the peak power of each spectrogram of S1-S4 using audio editing and recording application software. The participants were classified into three groups, namely, the absence of HF (n = 27), HF (n = 8), and high-risk HF (n = 5), based on the levels of NT-proBNP < 300, ≥300, and ≥900 pg/ml, respectively, and also the levels of ejection fraction (EF), such as preserved EF (n = 22), mildly reduced EF (n = 12), and reduced EF (n = 6). Results: The intensities of four components of HS (S1-S4) decreased linearly (p < 0.02-0.001) with levels of body mass index (BMI) (range, 16.2-33.0 kg/m2). Differences in S1 intensity (ΔS1) and its frequency (ΔfS1) between two consecutive beats were non-audible level and were larger in patients with HF than those in patients without HF (ΔS1, r = 0.356, p = 0.024; ΔfS1, r = 0.356, p = 0.024). The cutoff values of ΔS1 and ΔfS1 for discriminating the presence of high-risk HF were 4.0 dB and 5.0 Hz, respectively. Conclusions: Despite significant attenuations of all four components of HS by BMI, beat-to-beat alterations of both intensity and frequency of S1 were associated with the severity of HF. Acoustic quantification of HS enabled analyses of sounds below the audible level, suggesting that sound analysis might provide an early sign of HF.

16.
Midwifery ; 132: 103952, 2024 May.
Article in English | MEDLINE | ID: mdl-38442530

ABSTRACT

AIM: This study aimed to explore student midwives' theoretical knowledge of intrapartum intermittent auscultation, their confidence in, and their experience of this mode of fetal monitoring. DESIGN AND SETTING: An online cross-section survey with closed and open questions. Descriptive statistics were used to analyse participants' intermittent auscultation knowledge, confidence, and experience. Reflexive thematic analysis was used to identify patterns within the free text about participants' experiences. PARTICIPANTS: Undergraduate midwifery students (n = 303) from Nursing and Midwifery Council-approved educational institutions within the United Kingdom. FINDINGS: Most participants demonstrated good theoretical knowledge. They had witnessed the technique being used in clinical practice, and when performed, the practice was reported to be in line with national guidance. In closed questions, participants reported feeling confident in their intermittent auscultation skills; however, these data contrasted with free-text responses. CONCLUSION: This cross-sectional survey found that student midwives possess adequate knowledge of intermittent auscultation. However, reflecting individual clinical experiences, their confidence in their ability to perform intermittent auscultation varied. A lack of opportunity to practice intermittent auscultation, organisational culture, and midwives' preferences have caused student midwives to question their capabilities with this essential clinical skill, leaving some with doubt about their competency close to registration.


Subject(s)
Clinical Competence , Students, Nursing , Humans , Cross-Sectional Studies , Female , United Kingdom , Students, Nursing/statistics & numerical data , Students, Nursing/psychology , Surveys and Questionnaires , Adult , Clinical Competence/standards , Clinical Competence/statistics & numerical data , Pregnancy , Nurse Midwives/statistics & numerical data , Nurse Midwives/education , Nurse Midwives/psychology , Heart Rate, Fetal/physiology , Midwifery/education , Midwifery/methods , Midwifery/statistics & numerical data , Education, Nursing, Baccalaureate/methods , Auscultation/methods , Auscultation/statistics & numerical data , Auscultation/standards
17.
Sensors (Basel) ; 24(5)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38475162

ABSTRACT

An educational augmented reality auscultation system (EARS) is proposed to enhance the reality of auscultation training using a simulated patient. The conventional EARS cannot accurately reproduce breath sounds according to the breathing of a simulated patient because the system instructs the breathing rhythm. In this study, we propose breath measurement methods that can be integrated into the chest piece of a stethoscope. We investigate methods using the thoracic variations and frequency characteristics of breath sounds. An accelerometer, a magnetic sensor, a gyro sensor, a pressure sensor, and a microphone were selected as the sensors. For measurement with the magnetic sensor, we proposed a method by detecting the breathing waveform in terms of changes in the magnetic field accompanying the surface deformation of the stethoscope based on thoracic variations using a magnet. During breath sound measurement, the frequency spectra of the breath sounds acquired by the built-in microphone were calculated. The breathing waveforms were obtained from the difference in characteristics between the breath sounds during exhalation and inhalation. The result showed the average value of the correlation coefficient with the reference value reached 0.45, indicating the effectiveness of this method as a breath measurement method. And the evaluations suggest more accurate breathing waveforms can be obtained by selecting the measurement method according to breathing method and measurement point.


Subject(s)
Augmented Reality , Stethoscopes , Humans , Auscultation , Respiration , Exhalation , Respiratory Sounds
18.
Cureus ; 16(1): e53013, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38410315

ABSTRACT

One of the many physical exam skills introduced to medical students during their pre-clerkship education is cardiac auscultation, one purpose of which is to teach the detection and identification of heart murmurs. Cardiac auscultation with a stethoscope has been the standard method of teaching. Another method, point-of-care ultrasound (POCUS), has been recently introduced as another modality by which students learn to detect and identify murmurs. The emerging popularity of POCUS in undergraduate medical curricula has led many institutions to include it in their curricula; however, doing so is challenging. Not only is cost a major factor, but reorganizing curricula to allow sufficient time for POCUS training has proven to be difficult. Additionally, the presence of notable gaps in the literature regarding the efficacy of POCUS for teaching the detection and identification of heart murmur has increased scrutiny of its value. Studies that assessed teaching cardiac auscultation to medical students in their pre-clinical years via stethoscope have used different teaching methods. However, evaluation of these studies identified numerous limitations, one being little long-term retention of cardiac auscultation knowledge. Furthermore, several barriers to integration of POCUS in undergraduate medical education were identified. The purpose of this review is to synthesize the literature comparing the effectiveness of these different tools of a cardiac exam for detection of heart murmurs in undergraduate medical education and identify gaps in literature requiring future exploration.

19.
Pflege ; 2024 Feb 06.
Article in German | MEDLINE | ID: mdl-38319307

ABSTRACT

Critical care nurses' decision-making regarding verification of blindly inserted gastric tubes: A cross-sectional questionnaire study Abstract: Background: The placement and verification of the correct position of blindly applied gastric tubes is regularly performed by nurses in clinical practice. International guidelines recommend a radiological verification as a "first-line" method or if pH measurement is not possible. For Germany, neither evidence-based recommendations nor current data are available. Question: Which methods are used by nurses in German intensive care units for verification of the correct position of blindly applied gastric tubes and how do they assess the reliability of different methods? Methods: Multicenter questionnaire survey. Intensive care units in a non-probability, citeria-based sampling of hospitals in and around Cologne, Germany were included. One nurse was included per participating ward. Analyses were mostly descriptive. Results: In 22 hospitals, 38 wards agreed to participate and 32 (84%) responded to the survey. Auscultation of the upper abdomen with simultaneous air insufflation and aspiration of gastric secretions are frequently used methods for determining the position of gastric tubes. Participants consider auscultation, aspiration of gastric secretions, and radiological control as reliable methods. Conclusions: The findings are in contrast to international recommendations and support the need for evidence-based best practice recommendations and training. Likewise, there is a need for research on feasible bedside methods.

20.
J Vet Intern Med ; 38(1): 495-504, 2024.
Article in English | MEDLINE | ID: mdl-38192117

ABSTRACT

BACKGROUND: Standard thoracic auscultation suffers from limitations, and no systematic analysis of breath sounds in asthmatic horses exists. OBJECTIVES: First, characterize breath sounds in horses recorded using a novel digital auscultation device (DAD). Second, use DAD to compare breath variables and occurrence of adventitious sounds in healthy and asthmatic horses. ANIMALS: Twelve healthy control horses (ctl), 12 horses with mild to moderate asthma (mEA), 10 horses with severe asthma (sEA) (5 in remission [sEA-], and 5 in exacerbation [sEA+]). METHODS: Prospective multicenter case-control study. Horses were categorized based on the horse owner-assessed respiratory signs index. Each horse was digitally auscultated in 11 locations simultaneously for 1 hour. One-hundred breaths per recording were randomly selected, blindly categorized, and statistically analyzed. RESULTS: Digital auscultation allowed breath sound characterization and scoring in horses. Wheezes, crackles, rattles, and breath intensity were significantly more frequent, higher (P < .001, P < .01, P = .01, P < .01, respectively) in sEA+ (68.6%, 66.1%, 17.7%, 97.9%, respectively), but not in sEA- (0%, 0.7%, 1.3%, 5.6%) or mEA (0%, 1.0%, 2.4%, 1.7%) horses, compared to ctl (0%, 0.6%, 1.8%, -9.4%, respectively). Regression analysis suggested breath duration and intensity as explanatory variables for groups, wheezes for tracheal mucus score, and breath intensity and wheezes for the 23-point weighted clinical score (WCS23). CONCLUSIONS AND CLINICAL IMPORTANCE: The DAD permitted characterization and quantification of breath variables, which demonstrated increased adventitious sounds in sEA+. Analysis of a larger sample is needed to determine differences among ctl, mEA, and sEA- horses.


Subject(s)
Asthma , Horse Diseases , Horses , Animals , Respiratory Sounds/veterinary , Respiratory Sounds/diagnosis , Case-Control Studies , Prospective Studies , Asthma/diagnosis , Asthma/veterinary , Auscultation/veterinary , Horse Diseases/diagnosis
SELECTION OF CITATIONS
SEARCH DETAIL
...