Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
Gac Med Mex ; 157(4): 397-403, 2021.
Article in English | MEDLINE | ID: mdl-35133337

ABSTRACT

INTRODUCTION: Fundus autofluorescence (FAF) has shown sensitivity in the detection of macular edema. OBJECTIVES: To evaluate indices formed with FAF and retinal anatomical-functional variables in patients with diabetic macular edema (DME) treated with ziv-aflibercept (ziv-AFL). METHODS: Twenty-nine eyes of 15 DME patients who received ziv-AFL intravitreal injections were included in the study. Best-corrected visual acuity (BCVA), contrast sensitivity (CS), optical coherence tomography (OCT) and FAF were evaluated before treatment and at one and two months. OCT variables were central subfield thickness (CST), macular volume (MV) and macular cube average thickness (MCAT). FAF/BCVA, FAF/CS, FAF/CST, FAF/MV and AF/MCAT indices baseline values were obtained. Analysis was performed with Spearman's rank correlation coefficient and linear regression analysis. RESULTS: There was a significant correlation between baseline FAF/BCVA index and BCVA at second month (rs = - 0.78, p = 0.000), between baseline FAF/CS index and BCVA at second month (rs = -0.68, p = 0.0009) and between baseline FAF/CS index and MV at first month of follow-up (rs = 0.64, p = 0.002). CONCLUSIONS: In DME, composite indices with baseline FAF predict variables such as BCVA in the follow-up of patients receiving ziv-AFL.


INTRODUCCIÓN: La autofluorescencia retiniana (AF) ha mostrado sensibilidad en la detección del edema macular. OBJETIVOS: Evaluar índices formados con la AF y variables anatomofuncionales retinianas en pacientes con edema macular diabético (EMD) tratados con ziv-aflibercept (ziv-AFL). MÉTODOS: Fueron incluidos 29 ojos de 15 pacientes con EMD que recibieron inyecciones intravítreas de ziv-AFL. Se evaluó agudeza visual mejor corregida (AVMC), sensibilidad al contraste (SC), tomografía de coherencia óptica (TCO) y AF, antes del tratamiento, así como al primer y segundo mes de iniciado este. Las variables de la TCO fueron grosor foveal central (GFC), volumen macular (VM) y grosor promedio macular (GPM). Se obtuvieron los valores basales de AF/AVMC, AF/SC, AF/GFC, AF/VM y AF/GPM. Se realizó análisis con el coeficiente de correlación de rangos de Spearman y análisis de regresión lineal. RESULTADOS: Hubo una correlación significativa entre el índice AF/AVMC basal y la AVMC en el segundo mes (rs = −0.78, p = 0.000), entre el índice AF/SC basal y la AVMC en el segundo mes (rs = −0.68, p = 0.0009) y entre AF/SC basal y el VM en el primer mes de seguimiento (rs = 0.64, p = 0.002). CONCLUSIONES: En el EMD, los índices compuestos con AF basales predicen variables como AVMC en el seguimiento de pacientes que reciben ziv-AFL.


Subject(s)
Diabetes Mellitus , Diabetic Retinopathy , Macular Edema , Diabetic Retinopathy/diagnostic imaging , Follow-Up Studies , Fundus Oculi , Humans , Macular Edema/diagnostic imaging , Macular Edema/etiology , Tomography, Optical Coherence , Treatment Outcome , Visual Acuity
2.
Gac Med Mex ; 155(5): 493-498, 2019.
Article in English | MEDLINE | ID: mdl-31695225

ABSTRACT

INTRODUCTION: Patients with diabetic macular edema can develop fundus autofluorescence alterations; thus far, these alterations have been more widely studied with scanning or confocal laser systems. OBJECTIVE: To describe and classify fundus autofluorescence abnormal patterns in patients with diabetic macular edema using the fundus autofluorescence system with a flash camera. METHOD: Observational, retrospective, cross-sectional, descriptive study. Fundus autofluorescence digital images of non-comparative cases with untreated diabetic macular edema, obtained and stored with a flash camera system, were assessed. Inter-observer variability was evaluated. RESULTS: 37 eyes of 20 patients were included. Lens opacity was the most common cause of inadequate image quality. Five different fundus autofluorescence patterns were observed: decreased (13%), normal (40%), focal hyper-autofluorescent (17%), multi-focal hyper-autofluorescent (22%) and plaque-like hyper-autofluorescent (8%). The kappa coefficient was 0.906 (p = 0.000). CONCLUSIONS: Different fundus autofluorescence phenotypic patterns are observed with flash camera systems in patients with diabetic macular edema. A more accurate phenotypic classification could help establish prognostic factors for visual loss or for the design of clinical trials for diabetic macular edema.


INTRODUCCIÓN: Los pacientes con edema macular diabético pueden presentar alteraciones en la autofluorescencia retiniana, que hasta el momento han sido analizadas más con sistemas de láser de barrido o confocales. OBJETIVO: Describir y clasificar los patrones anormales de autofluorescencia retiniana en pacientes con edema macular diabético mediante el sistema de autofluorescencia retiniana con cámara de flash. MÉTODO: Estudio observacional, retrospectivo, transversal y descriptivo. Se evaluaron imágenes digitales de autofluorescencia retiniana de casos no comparativos con edema macular diabético no tratado, obtenidas y almacenadas con el sistema de cámara de flash.Se evaluó la variabilidad interobservador. RESULTADOS: Se incluyeron 37 ojos de 20 pacientes. La opacidad de medios fue la causa más común de calidad inadecuada de imagen. Se observaron cinco diferentes patrones de autofluorescencia retiniana: disminuida (13 %), normal (40 %), hiperautofluorescente unifocal (17 %), hiperautofluorescente multifocal (22 %) e hiperautofluorescente en placa (8 %). El coeficiente kappa fue de 0.906 (p = 0.000). CONCLUSIONES: En pacientes con edema macular diabético se presentan diferentes patrones fenotípicos de autofluorescencia retiniana con los sistemas de cámara de flash. Una clasificación fenotípica más precisa pudiera ayudar a establecer factores pronósticos de pérdida visual o al diseño de ensayos clínicos relativos a edema macular diabético.


Subject(s)
Diabetic Retinopathy/diagnostic imaging , Macular Edema/diagnostic imaging , Optical Imaging/instrumentation , Cataract , Cross-Sectional Studies , Female , Fundus Oculi , Humans , Male , Middle Aged , Observer Variation , Optical Imaging/classification , Optical Imaging/methods , Phenotype , Retrospective Studies
3.
Rev. bras. oftalmol ; 78(4): 260-263, July-Aug. 2019. graf
Article in Portuguese | LILACS | ID: biblio-1013684

ABSTRACT

Resumo A distrofia macular anular concêntrica benigna (DMACB) é uma patologia retiniana rara e provavelmente subdiagnosticada em nosso meio, que se caracteriza por um defeito retiniano em bull's eye sem uso prévio de antimaláricos, associado à preservação relativa da acuidade visual. Devido à escassez de publicações sobre o tema, existem poucos dados referentes aos resultados dos exames complementares nesta patologia. No presente artigo, apresenta-se a descrição da autofluorescência em um caso clássico de DMACB, ainda inédita na literatura, podendo acrescentar achados importantes para auxiliar no diagnóstico e seguimento da doença.


Abstract The benign concentric annular macular dystrophy (BCAMD) is a very rare and probably underdiagnosed eye disease, characterized by a retinal fault in bull's eye pattern, without the association with antimalarial use, but related with good visual acuity. Since there aren't many publications about this condition, is hard to find data regarding the results of complementary examination. In this article, is presented the description of fundus autofluorescence in a classic BCAMD case, yet unpublished, and capable of helping the diagnosis and follow-up of this pathology.


Subject(s)
Humans , Male , Aged , Retina/physiopathology , Fluorescein Angiography/methods , Hypopigmentation/diagnosis , Macular Degeneration/diagnosis , Ophthalmoscopy/methods , Atrophy , Tomography, Optical Coherence , Retinal Pigment Epithelium/pathology , Optical Imaging/methods , Fundus Oculi , Lipofuscin/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...