Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Angiol. (Barcelona) ; 75(4): 218-227, Juli-Agos. 2023. ilus, tab
Article in English, Spanish | IBECS | ID: ibc-223702

ABSTRACT

Introducción: los dispositivos liberadores de energía permiten la hemostasia de los vasos mediante generación de calor y la coagulación de las proteínas de la pared. Sin embargo, se desconoce su comportamiento a medio plazo en la cirugía arterial con injertos venosos. Objetivos: desarrollar un modelo animal que permita evaluar la eficacia y seguridad del sellado a medio plazo tras el proceso de cicatrización. Comparar y evaluar qué modelo in vivo presenta menor morbilidad y mayor supervivencia a las 4 semanas. Material y métodos: estudio experimental animal de 16 conejos New Zealand a los que se interpuso un fragmento de vena safena humana (VS) con una colateral. Se desarrollaron dos modelos arteriales: bypass termino-terminal de VS en aorta infrarrenal (n = 5) y plastia de aorta con parche de VS (n = 11). La colateral venosa fue sellada, previa aleatorización, con electrocoagulación bipolar controlada por temperatura (EB) o bisturí armónico (BA). Todos los animales recibieron inmunosupresión y profilaxis antitrombótica. Se registró la tasa de paraplejia, de infección, de hemorragia y de supervivencia. Resultados: la supervivencia a los 7 días fue del 50 % (2/4) en el modelo de injerto de interposición. Sin embargo, ningún animal sobrevivió a las 4 semanas de seguimiento en este modelo. En el grupo de plastia de aorta, la supervivencia a los 7 días fue del 55,56 % (5/9) y del 44,44 % (4/9) a las 4 semanas (p = 0,5). La tasa de paraplejia en el grupo de interposición fue del 100 % e inferior en el modelo de plastia de aorta (25 %) (p = 0,03). El tiempo medio de isquemia en el modelo de plastia de aorta (37,11 ± 8,1 min) fue inferior al del grupo del bypass (42 ± 10,61 min) (p = 0,414). En ningún caso se objetivó hemorragia intraabdominal ni reacción adversa a la inmunosupresión. Conclusiones: el modelo arterial de plastia de aorta con parche de VS presentó menor tasa de paraplejia, así como menor mortalidad posoperatoria a los 7 días...(AU)


Introduction: energy sealing devices achieve hemostasis of the vessels through the heat generated and coagula-tion of the vascular wall proteins. However, the mid-term efficacy profile for venous graft sealing in arterial bypasssurgery remains unknown.Objectives: to create an animal model to compare the mid-term efficacy and safety profile at the sealing areaafter the healing process. To compare and assess which in vivo arterial models show lower morbidity and highersurvival rates after 4 weeks.Material and methods: this was an in vivo experimental study of 16 New Zealand rabbits. In each rabbit a humansaphenous vein (SV) with, at least, 1 venous collateral was implanted. Two arterial models were developed: infrarre-nal aorta bypass with SV (n = 5) and aortoplasty with SV patch (n = 11). In both models the collateral was randomizedand sealed with either 1 these 2 energy sealing devices: electrothermal bipolar vessel sealing (EBVS) or Harmonicscalpel (HS). Every animal was treated with antithrombotic prophylaxis and immunosuppressive medication. Therates of intraoperative mortality, paraplegia, infection, bleeding, and survival were all studied.Results: two animals (50 %) survive 7 days after surgery in the bypass model. However, no animal survived 4 daysafter surgery in this model. In the aortoplasty group, the 7-day survival rate was 55.56 % (5/9) while the 4-weeksurvival rate was 44.44 % (4/9) (p = 0.05). The rate of paraplegia was 100 % for the bypass model and much lowerfor the patch group (25 %) (p = 0.03). The mean ischemic time was lower for the aortoplasty model (37.11 ± 8.1 min)compared to the bypass group (42 ± 10.61 min) (p = 0.414). No animal showed intrabdominal hemorrhages oradverse drug reactions associated with the immunosuppressive medication.Conclusion: aortoplasty with the SV patch model showed lower rates of paraplegia and 7-day mortality in theanimal model...(AU)


Subject(s)
Animals , Rabbits , Amputation, Surgical , Arteries/surgery , Saphenous Vein , Electrocoagulation
2.
Article in English, Spanish | MEDLINE | ID: mdl-31594557

ABSTRACT

INTRODUCTION: Surgical techniques for extirpation of tumours of the parotid gland have evolved significantly in recent years. Previous data suggest the use of Harmonic Scalpel reduced operative time, intraoperative blood loss, postoperative drain production, and incidence of facial nerve injury, in comparison to cold scalpel dissection MATERIAL AND METHODS: retrospective analysis of 2group of patients operated using harmonic scalpel versus cold knife dissection and bipolar diathermy and compare operative time and post-surgical complication rate:, facial nerve injury, sialocele or salivary fístula formation, after parotidectomy for benign parotid tumours. RESULTS: 108 patients were included. Regarding surgical time, the mean time to using Harmonic Scalpel was 114±39 (Min: 60/Max: 240), and the mean time using bipolar diathermy was 135±38 (Min: 90/Max: 285) and this was the only significant difference between the 2techniques (p=.049). CONCLUSIONS: Harmonic scalpel is a safe and effective tool to perform parotid surgery in benign tumours. However, a shorter surgical time was the only advantage found over the traditional cold dissection and bipolar dissection method.


Subject(s)
Diathermy/methods , Dissection/methods , Parotid Neoplasms/surgery , Surgical Instruments , Ultrasonic Therapy/instrumentation , Adenolymphoma/surgery , Adenoma, Pleomorphic/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Diathermy/adverse effects , Dissection/adverse effects , Dissection/instrumentation , Female , Humans , Male , Middle Aged , Operative Time , Postoperative Complications/epidemiology , Retrospective Studies , Ultrasonic Therapy/methods , Young Adult
3.
Rev. med. Rosario ; 83(3): 123-127, sep.-dic. 2017.
Article in Spanish | LILACS | ID: biblio-973316

ABSTRACT

El trabajo repasa la evolución histórica en el entendimiento y en el manejo de la cirugía tiroidea. Describe los orígenes de esta cirugía y su ejecución, mucho antes de que se entendiera el funcionamiento de la glándula. Enumera los personajes más trascendentes de esta historia y cómo otras técnicas aplicadas en la cirugía oncológica general se adaptaron a la cirugía de cabeza y cuello. Se mencionan las innovaciones tecnológicas en cirugía tiroidea.


This work reviews the historical evolution of thyroid surgery, its understanding and management. It mentions the origins of this surgical procedure and its execution well before the understanding of the glandular function. The leading persons in this historical field are enumerated; and a review is made of how other techniques applied in surgical oncology were adapted in head and neck surgery. Technological innovations in thyroid surgery are enumerated.


Subject(s)
Humans , Diagnostic Techniques and Procedures/trends , Review Literature as Topic , Thyroid Neoplasms/history , Thyroid Neoplasms/surgery , Endocrinology/history , History of Medicine , Technological Development
4.
Cir Esp ; 91(10): 664-71, 2013 Dec.
Article in Spanish | MEDLINE | ID: mdl-23473435

ABSTRACT

OBJECTIVE: To analyse the potential advantages and outcomes of the new Harmonic Focus™ (Focus) device compared to the Harmonic Scalpel™ ACS-14C in benign thyroid surgery. METHODS: A controlled randomised study was conducted in which the Focus was compared to former ACS-14C device in patients undergoing total thyroidectomy for multinodular goitre. The primary endpoint was time of surgery. The secondary endpoints were time of use of the device, number of ligatures, blood loss, hypocalcaemia, laryngeal nerve impairment, postoperative pain and quality of life. RESULTS: Two groups of patients were included, 26 patients in group i (ACS-14C) and 28 in group ii (Focus). There was a 16% reduction in surgical time (78.7 ± 22.01 vs. 66 ± 17.0 min; P<.05) between group i and ii respectively. The Focus was used longer than ACE-14S, both in absolute time (26.0 ± 7.7 vs. 10.0 ± 3.5 minutes; P<.05), as well as in relative time (40.7 ± 11.8% vs. 13.1 ± 4.1%; P<.05), respectively. A significant reduction in number of ligatures in Focus patients was also observed (0,3 ± 0,8 vs. 2.9 ± 3.6; P<.05). Budget impact analysis showed an additional average savings per procedure of 179.74 €. CONCLUSIONS: Focus ergonomics significantly improved the operation time in thyroidectomy causing a positive impact on the budget. Focus also adds further benefits to those previously achieved by Harmonic technology, and it is by itself more cost-effective in total thyroidectomy than ACS-14C.


Subject(s)
Goiter, Nodular/surgery , Thyroidectomy , Budgets , Female , Humans , Male , Middle Aged , Prospective Studies , Single-Blind Method , Surgical Instruments , Thyroidectomy/instrumentation , Thyroidectomy/methods
5.
Rev. venez. cir ; 62(1): 16-22, mar. 2009. tab, graf
Article in Spanish | LILACS | ID: lil-539980

ABSTRACT

Determinar la utilidad del bisturi armónico en la realización de la colecistectomía laparoscópica. El tipo de estudio es descriptivo, prospectivo. La muestra fue de 25 pacientes con diagnóstico de litiasis vesicular, la distribución según el sexo y la edad, fue veinte (20) pacientes femeninas y cinco (5) maculinos con una media de edad de 45 años (18-69 años). El tiempo quirúrgico total con una media de 56,7 min; un tiempo de armónico minimo con una media de 30,5 min. Hubo una complicación que representa el 4 por ciento de la muestra, la misma estuvo representada por una fuga biliar. En vista de la complicación presentada se colocó dren a los 13 pacientes restantes, que se retiró a las 24 horas del postoperatorio. El tiempo de hospitalización fue de 24 horas en 21 pacientes y de 48 horas en 4 pacientes que representa 84 por ciento y 16 por ciento de la muestra respectivamente. La colecistectomía laparoscópica con el uso del bisturi armónico para la ligadura del conducto y la arteria císticos es un procedimiento que es factible y seguro con bajas tasas de morbimortalidad.


Subject(s)
Humans , Male , Adolescent , Adult , Female , Middle Aged , Cholecystectomy, Laparoscopic/methods , Cystic Duct/surgery , Urinary Bladder Calculi/surgery , Urinary Bladder Calculi/diagnosis , Urinary Bladder Calculi/pathology , Ultrasonography , Medical Records , Incidence , Ligation/methods
6.
Rev. venez. oncol ; 18(4): 215-220, oct.-dic. 2006. ilus
Article in Spanish | LILACS | ID: lil-549448

ABSTRACT

El propósito de este estudio, es investigar la utilidad del uso del bisturí armónico en el tratamiento de la patología tiroidea. Aunado a los avances existentes en los estudios imaginológicos, sobre todo el ultrasonido, ultrasonido Doppler y, la instauración de la punción aspiración con aguja fina en los pacientes con nódulos tiroideos, el bisturí armónico permite no sólo ahorrar tiempo quirúrgico, sino que disminuye significativamente la posibilidad de complicaciones. El uso de este equipo ha evolucionado a la par del desarrollo de la cirugía laparoscópica, que ha permitido el uso de técnicas novedosas el desarrollo de la cirugía mínimamente invasiva. La tiroidectomía efectuada con bisturí armónico es un procedimiento factible, con escasas complicaciones y que permite principalmente ahorrar tiempo quirúrgico, lo cual redundará en los costos finales de la cirugía.


The purpose of this study is to investigate the utility of the use of the harmonic scalpel in the treatment of the thyroid pathology. Joined to the existent advances in the imaginologic studies, ultrasound and Doppler and setting-up of the fine-needle aspiration in patients with thyroid nodules, the harmonic scalpel only allows not to save surgical time, but rather it diminishes the possibility of complications significantly. The use of this scalpel has evolved at same time of the development of the laparoscopic surgery, which has allowed the use of technical novel the development of the minimally invasive thyroidectomy. The thyroidectomy made with harmonic scalpel is a feasible procedure, with low complications and that allows mainly saving surgical time, that which will redound in the final costs of the surgery.


Subject(s)
Humans , Female , Ultrasonography, Doppler , Thyroid Neoplasms/surgery , Thyroid Neoplasms/pathology , Thyroidectomy/methods , Biopsy/methods , Medical Oncology
7.
Rev. venez. cir ; 58(2): 53-57, jun. 2005. graf
Article in Spanish | LILACS | ID: lil-540035

ABSTRACT

Presentar la experiencia obtenida por los autores en el uso del bisturí armónico en pacientes con hemorroides grado III y IV, a quienes se les practicó hemorroidectomía por nuestro equipo quirúrgico del Centro Policlínico La Viña, Valencia. Es un estudio retrospectivo donde se revisaron las historias de 40 pacientes que acudieron a la consulta quirúrgica entre enero del año 2000 y agosto de 2003 con diagnóstico de hemorroides grado III y IV, a quienes se les practicó hemorroidectomía. Centro Policlínico La Viña, Valencia hospital privado. La técnica de hemorroidectomía con bisturí armónico resultó satisfactoria: redujo el tiempo quirúrgico y el sangrado intraoperatorio minimizando el daño tisular, permitió menor estancia hospitalaria y rápido retorno a las actividades cotidianas. Se presentaron dos sangramientos posoperatorios leves, uno por actividad física prescoz. No se evidenciaron complicaciones tardias como estenosis anal ni ectropión. Los autores concluyen que la hemorroidectomía con el uso del bisturí armónico es una alternativa favorable en la técnica quirúrgica, asociada a un mínimo de complicaciones intra y postoperatorias, considerando el instrumento como una opción factible y casi ideal para dicho procedimiento.


Subject(s)
Humans , Male , Adult , Female , Middle Aged , Hemorrhage/etiology , Hemorrhoids/surgery , Hemorrhoids/pathology , Diagnostic Techniques, Surgical/instrumentation , Anal Canal/surgery , Medical Records , Surgical Instruments , Prone Position
SELECTION OF CITATIONS
SEARCH DETAIL
...