Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Neurointervention ; 7(2): 93-101, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22970418

ABSTRACT

PURPOSE: The optimal management of geometrically complex aneurysms remains challenging. The aim of this retrospective study was to evaluate the safety and feasibility of branch-selective technique (BT) in wide-necked aneurysms with an acute angle branch incorporated into the sac. MATERIALS AND METHODS: Eight consecutive patients harboring wide-necked cerebral aneurysms with an incorporated, acute angle branch (mean, 30.4°) underwent coiling over an 18-month period. Dome-to-neck ratio ranged from 0.9 to 1.8 (mean, 1.2). Every procedure utilized BT, i.e., stent- or catheter-assisted coiling through the incorporated branch. RESULTS: Technical success was achieved in all cases. With the aim to avoid the risk of aneurysmal rupture during struggling intraaneurysmal wire navigation, a 'looping method' and retrograde approach of a preshaped 0.014' microcatheter (C or J) was used for branch access in five cases and a 'looping method' and antegrade approach in one case. In the remaining one, just the C-preshape was enough to directly enter the branch without intraaneurysmal wire navigation. Overall, stent-assisted coiling was performed in seven cases, while catheter-assisted coiling was undertaken in one. The only complication was thrombotic posterior inferior cerebellar artery occlusion in one case, which was recanalized after tirofiban infusion. New neurological deficits were not identified in any cases. CONCLUSION: BT seems safe and feasible for wide-necked aneurysms with an acute angle branch incorporated into the sac. The looping method may offer safe access to the incorporated, acute angle branch and should be considered for replacement of the fearful intra-aneurysmal wire navigation.

2.
Neurointervention ; : 93-101, 2012.
Article in English | WPRIM (Western Pacific) | ID: wpr-730231

ABSTRACT

PURPOSE: The optimal management of geometrically complex aneurysms remains challenging. The aim of this retrospective study was to evaluate the safety and feasibility of branch-selective technique (BT) in wide-necked aneurysms with an acute angle branch incorporated into the sac. MATERIALS AND METHODS: Eight consecutive patients harboring wide-necked cerebral aneurysms with an incorporated, acute angle branch (mean, 30.4degrees) underwent coiling over an 18-month period. Dome-to-neck ratio ranged from 0.9 to 1.8 (mean, 1.2). Every procedure utilized BT, i.e., stent- or catheter-assisted coiling through the incorporated branch. RESULTS: Technical success was achieved in all cases. With the aim to avoid the risk of aneurysmal rupture during struggling intraaneurysmal wire navigation, a 'looping method' and retrograde approach of a preshaped 0.014' microcatheter (C or J) was used for branch access in five cases and a 'looping method' and antegrade approach in one case. In the remaining one, just the C-preshape was enough to directly enter the branch without intraaneurysmal wire navigation. Overall, stent-assisted coiling was performed in seven cases, while catheter-assisted coiling was undertaken in one. The only complication was thrombotic posterior inferior cerebellar artery occlusion in one case, which was recanalized after tirofiban infusion. New neurological deficits were not identified in any cases. CONCLUSION: BT seems safe and feasible for wide-necked aneurysms with an acute angle branch incorporated into the sac. The looping method may offer safe access to the incorporated, acute angle branch and should be considered for replacement of the fearful intra-aneurysmal wire navigation.


Subject(s)
Humans , Aneurysm , Arteries , Endovascular Procedures , Intracranial Aneurysm , Retrospective Studies , Rupture , Tyrosine
SELECTION OF CITATIONS
SEARCH DETAIL
...