Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.592
Filter
1.
Cureus ; 16(6): e62021, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38989363

ABSTRACT

Maintenance of biological width serves as a primary factor in periodontal-restorative relationships. Crown lengthening (CL) is a technique to prevent violation of biological width, with the laser method offering the advantage of surgical and patient-related outcomes. Laser CL with retraction helps with the excision of tissues, increasing the CL, maintaining the gingival contour with adequate exposure to the finish line to record the tooth preparation features. This helps to achieve the functional and esthetic outcomes essential for restorative dentistry. The marginal fit, contour, and adaptation of the crown can be further enhanced by computer-aided design and computer-aided manufacturing (CAD/CAM) technology improving patient and clinical outcomes. Hence, this case report aims to indulge the laser-assisted procedures and CAD/CAM technology to fabricate and deliver a zirconia crown maintaining the periodontal-restorative factors.

2.
J Esthet Restor Dent ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963682

ABSTRACT

OBJECTIVE: To evaluate the effect of the deterioration of computer aided design/computer aided manufacturing (CAD/CAM) burs during zirconia milling, on surface roughness, contact angle, and fibroblast viability. MATERIALS AND METHODS: Ceramic blocks were milled and 75 ceramic disks (8 × 1.5 mm) made and allocated into three groups (n = 25): G1-brand new 2L and 1L burs, G2-2L bur at the end of lifetime and brand new 1L bur and G3-both burs at the end of their lifetimes. Roughness (Ra, Rq, and Rz) was evaluated using a 3D optical profilometer, the contact angle by the sessile drop method and the cell viability of the mouse NIH/3T3 fibroblast, using the Alamar Blue assay at intervals of 24, 48, and 72 h (ISO 10993-5). Data were analyzed by one-way ANOVA and Kruskal-Wallis tests (p ≤ 0.05). RESULTS: Roughness increased as the burs deteriorated and G3 (0.27 ± 0.04) presented a higher value for Ra (p < 0.001). The highest contact angle was observed in G3 (86.2 ± 2.66) when compared with G1 (63.7 ± 12.49) and G2 (75.3 ± 6.36) (p < 0.001). Alamar Blue indicated an increase in cell proliferation, with no significant differences among the groups at 24 and 72 h (p > 0.05). CONCLUSIONS: The deterioration of the burs increased the surface roughness and decreased the wettability, but did not interfere in cell viability and proliferation. CLINICAL SIGNIFICANCE: The use of custom zirconia abutments represents an effective strategy for single crowns restorations. Our findings suggest that these abutments can be efficiently milled using CAD/CAM burs within their recommended lifetime.

3.
Jpn Dent Sci Rev ; 60: 190-197, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38974884

ABSTRACT

Most reports on duplicate dentures are introduction to fabrication methods or clinical case reports. Only a few studies have verified their clinical effectiveness; hence, evidence to construct useful clinical guidelines for duplicate denture use is lacking. This review aimed to comprehensively investigate reports on duplicate dentures to accumulate evidences that will contribute to the formulation of clinical practice guidelines. Duplicate dentures are effectively used for impression making and bite registration when fabricating new dentures, thereby reducing the number of clinic visits and treatment time. Duplicate denture can also be used as temporary or new dentures. Older people in whom various adaptive abilities have declined, may find it difficult to adjust to new dentures and experience stress, even if the shape is appropriate. Duplicate dentures, which reproduces the shape of old dentures that they are used to, have the advantage of being more familiar to older people and less stressful. When manufacturing duplicate dentures, digital methods such as milling and three-dimensional printing are superior to conventional methods regarding working time and cost. A notable advantage of the digital method is that the denture shape can be saved as digital data, and the denture can be easily duplicated if lost.

4.
J Esthet Restor Dent ; 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38979970

ABSTRACT

OBJECTIVE: In oral rehabilitation, a full mouth minimal invasive treatment can represent a major challenge for the patient and the dentist. The purpose of this article is to present a new technique to restore eroded teeth and recover the vertical dimension with a simple and predictable technique. CLINICAL CONSIDERATIONS: Occlusal tabletop restorations are a suitable conservative option to restore anatomy and vertical dimension augmentation but highly sensitive. The cementation of those restorations without stable landmarks, the cement excess removal, the insertion path, or the time needed are some of the difficulties can be faced. Now a days with the new CAD-CAM techniques is possible to develop a new occlusal tabletop manufacturing alternative utilizing 3D-printed technology by unifying the restorations with a customized connector that allows us to print several onlays at same time, as a single object, also being cemented at once. CONCLUSIONS: This protocol reduces the technique sensitivity of a vertical dimension oral rehabilitation process, reduce the chair time, enhancing the patient-comfort and delivers a unique way to restore dental lost anatomy as a definitive or temporary way with printing materials. CLINICAL SIGNIFICANCE: With the advent of new CAD-CAM 3D printing materials, which are increasingly versatile and gaining favor among clinicians, it is now possible to address complex clinical situations with greater predictability. This technology enables the development of treatment solutions that are both effective and efficient, consequently reducing clinical time for the patient.

5.
Clin Oral Investig ; 28(8): 417, 2024 Jul 08.
Article in English | MEDLINE | ID: mdl-38972945

ABSTRACT

OBJECTIVES: The treatment of fractures prioritizes the restoration of functionality through the realignment of fractured segments. Conventional methods, such as titanium plates, have been employed for this purpose; however, certain limitations have been observed, leading to the development of patient-specific plates. Furthermore, recent advancements in digital technology in dentistry enable the creation of virtual models and simulations of surgical procedures. The aim was to assess the clinical effectiveness of patient-specific plates utilizing digital technology in treating mandibular fractures compared to conventional titanium plates. MATERIALS AND METHODS: Twenty patients diagnosed with mandibular fractures were included and randomly assigned to either the study or control groups. The surgical procedure comprised reduction and internal fixation utilizing patient-specific plates generated through virtual surgery planning with digital models for the study group, while the control group underwent the same procedure with conventional titanium plates. Assessment criteria included the presence of malunion, infection, sensory disturbance, subjective occlusal disturbance and occlusal force in functional maximum intercuspation (MICP). Statistical analysis involved using the Chi-square test and one-way repeated measures analysis of variance. RESULTS: All parameters showed no statistically significant differences between the study and control groups, except for the enhancement in occlusal force in functional MICP, where a statistically significant difference was observed (p = 0.000). CONCLUSION: Using patient-specific plates using digital technology has demonstrated clinical effectiveness in treating mandibular fractures, offering advantages of time efficiency and benefits for less experienced surgeons. CLINICAL RELEVANCE: Patient-specific plates combined with digital technology can be clinically effective in mandibular fracture treatment.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Mandibular Fractures , Titanium , Humans , Mandibular Fractures/surgery , Titanium/chemistry , Male , Female , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Adult , Treatment Outcome , Middle Aged , Computer-Aided Design , Surgery, Computer-Assisted/methods
6.
Clin Oral Investig ; 28(7): 413, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38965139

ABSTRACT

OBJECTIVES: This study compares the biofilm inhibition effects of denture cleaning tablets, carvacrol, and their combined use against Candida albicans on denture bases produced with different techniques. Additionally, the surface roughness and contact angles of these denture bases were evaluated. MATERIALS AND METHODS: Test samples were prepared from four different denture base materials (cold-polymerized, heat-polymerized, CAD/CAM milling, and 3D-printed). The surface roughness and contact angles of the test samples were measured using a profilometer and goniometer, respectively. For the evaluation of biofilm inhibition, samples were divided into 5 subgroups: Corega and carvacrol, separately and combined treatments, positive (inoculated with C. albicans) and negative control (non-inoculated with C. albicans, only medium). Biofilm mass was determined using the crystal violet method. An additional prepared test sample for each subgroup was examined under scanning electron microscopy (SEM). RESULTS: The surface roughness values of the 3D-printed test samples were found to be statistically higher than the other groups (P < .001). The water contact angle of all test materials was not statistically different from each other (P > .001). Corega and carvacrol, separately and combined, significantly decreased the amount of biofilm on all surfaces (P < .0001). Treatment of corega alone and in combination with carvacrol to the 3D-printed material caused less C. albicans inhibition than the other groups (P < .001; P < .05). CONCLUSIONS: The surface roughness values of all test groups were within the clinically acceptable threshold. Although Corega and carvacrol inhibited C. albicans biofilms, their combined use did not show a synergistic effect. CLINICAL RELEVANCE: Carvacrol may be used as one of the disinfectant agents for denture cleaning due to its biofilm inhibition property.


Subject(s)
Biofilms , Candida albicans , Cymenes , Denture Bases , Denture Cleansers , Materials Testing , Microscopy, Electron, Scanning , Surface Properties , Biofilms/drug effects , Candida albicans/drug effects , Denture Bases/microbiology , Cymenes/pharmacology , Denture Cleansers/pharmacology , Printing, Three-Dimensional , Tablets
7.
Dent Mater ; 2024 May 31.
Article in English | MEDLINE | ID: mdl-38824001

ABSTRACT

OBJECTIVE: Achieving a strong bond between Polyetheretherketone (PEEK) and veneering composites is challenging due to PEEKs low surface energy. This study examined the effects of sandblasting and bonding on the shear bond strength (SBS) between veneering composite and pigmented PEEK, considering artificial aging. METHODS: Of three pigmented PEEK compounds (DC4420R, DC4450R, DC4470R; Evonic Operations GmbH, Marl, Germany), 40 specimens each were milled and polished up to 2500 grit. Prior to veneering, specimens were divided into 4 subgroups: Subgroup 1: Polishing; 2: Polishing + bonding; 3: Sandblasting; 4: Sandblasting + bonding. Sandblasting was performed using Al2O3. Adhesive was an agent containing MMA (Signum Universal Bond, Kulzer GmbH, Hanau, Germany). After veneering (Composite, Kulzer GmbH) the subgroups were divided into 2 subgroups. One subgroup was immersed in 37 °C warm distilled water for 24 h. The second subgroup was artificially aged by thermocycling (TCL) with 5000 cycles in distilled water (5 °C / 55 °C; 30 s). Surface roughness, water contact angles and failure modes were recorded. SBS was measured using a universal testing machine. RESULTS: Results demonstrated that the combination of sandblasting and bonding significantly improved the SBS compared to polishing alone. PEEK color did not significantly influence the SBS. Aging by TCL had a negative effect on the SBS. SIGNIFICANCE: Sandblasting and the use of an adhesive containing MMA were found to be effective in achieving satisfactory SBS between veneering composite and pigmented PEEK surfaces. These pretreatment methods demonstrate their potential for establishing durable and reliable bonding in clinical applications.

8.
J Clin Med ; 13(12)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38930111

ABSTRACT

Dental implants have always played an important role in dentistry and have been used to replace missing teeth since around 600 AD. They can be classified into three groups: endosteal, subperiosteal, and transosteal. Over time, different materials have been used to manufacture dental implants and these, in turn, can be divided into three groups: metals, ceramics, and polymers. Today, the most commonly used treatment for edentulism is the use of endosteal implants. However, such an approach cannot be used in patients with severe alveolar ridge atrophy and, in such cases, custom subperiosteal implants are an alternative. This review article focuses on historical developments and improvements that have been made over recent years in treatment options for patients suffering from edentulism and significant resorption of the alveolar ridge. These treatment options involve the utilization of custom subperiosteal implants. This paper looks at the historical evolution of these implants, the significance of diagnostic imaging, and the application of the contemporary methods of production, such as CAD-CAM and additive manufacturing. The research emphasizes the importance of accuracy and personalization provided by these emerging technologies that have rendered subperiosteal implants a more feasible and less intrusive alternative for patients suffering from significant bone loss.

9.
Materials (Basel) ; 17(12)2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38930350

ABSTRACT

Although advancements in CAD/CAM technology allow for more personalized treatments, it is not clear how modifications in the CAD/CAM milling process could affect the restoration surface conditions and their mechanical behavior. The objective of this study was to evaluate the effect of different CAD/CAM milling protocols on the topography and fracture behavior of zirconia monolithic crowns (3Y-PSZ) subjected to a chewing simulation. Monolithic 3Y-PSZ premolar crowns were milled using three protocols (n = 13) (slow (S), normal (N), and fast (F)). Crowns were cemented on a dentin analog abutment and subjected to mechanical aging (200 N, 2 Hz, 1,500,000 cycles, 37 °C water). Surviving crowns were subjected to compressive load test and analyzed using fractography. Fracture load data were analyzed with two-parameter Weibull analysis. The surface topography of the crowns was examined with a stereomicroscope and a 3D non-contact profiler. All crowns survived the chewing simulation. Crowns milled using the F protocol had the greatest characteristic fracture load, while crowns produced with the S protocol showed high Weibull modulus. Groups N and S had a more uniform surface and detailed occlusal anatomy than group F. The CAD/CAM milling protocol affected the topography and mechanical behavior of 3Y-PSZ monolithic crowns.

10.
J Funct Biomater ; 15(6)2024 May 28.
Article in English | MEDLINE | ID: mdl-38921521

ABSTRACT

Computer-aided design and computer-aided manufacturing (CAD/CAM) techniques are based on either subtractive (milling prefabricated blocks) or additive (3D printing) methods, and both are used for obtaining dentistry materials. Our in vitro study aimed to investigate the behavior of human gingival fibroblasts exposed to methacrylate (MA)-based CAD/CAM milled samples in comparison with that of MA-based 3D-printed samples to better elucidate the mechanisms of cell adaptability and survival. The proliferation of human gingival fibroblasts was measured after 2 and 24 h of incubation in the presence of these samples using a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay, and the membrane integrity was assessed through the lactate dehydrogenase release. The level of reactive oxygen species, expression of autophagy-related protein LC3B-I, and detection of GSH and caspase 3/7 were evaluated by fluorescence staining. The MMP-2 levels were measured using a Milliplex MAP kit. The incubation with MA-based 3D-printed samples significantly reduced the viability, by 16% and 28% from control after 2 and 24 h, respectively. There was a 25% and 55% decrease in the GSH level from control after 24 h of incubation with the CAD/CAM milled and 3D-printed samples, respectively. In addition, higher levels of LC3B-I and MMP-2 were obtained after 24 h of incubation with the MA-based 3D samples compared to the CAD/CAM milled ones. Therefore, our results outline that the MA-CAD/CAM milled samples displayed good biocompatibility during 24-h exposure, while MA-3D resins are proper for short-term utilization (less than 24 h).

11.
Clin Oral Investig ; 28(7): 402, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38940942

ABSTRACT

OBJECTIVES: Evaluate the efficacy of denture cleaners on the adhesion of Candida albicans and their effects on the surface, optical, and mechanical properties of resins for conventional, milled, and 3D-printed denture bases. MATERIALS AND METHODS: A total of 240 resin samples were made, 120 for testing Candida albicans adhesion, optical stabilities (ΔE00), roughness (Ra), hydrophilicity (°), surface free energy (Owens-Wendt) and 120 samples for testing Candida albicans adhesion, surface microhardness (Knoop), flexural strength and modulus of elasticity in a three-point test, in which they were divided into 3 groups of denture resin (n = 40) and subdivided into 5 cleaners of dentures (n = 8). Data were evaluated by two-way ANOVA and Tukey's test for multiple comparisons (α = 0.05). RESULTS: Denture cleaners with an alkaline solution and dilute acid composition were those that showed the greatest effectiveness in reducing Candida albicans (P < 0.001), however 1% NaOCl significantly affected the properties of the resins (P < 0.05). Denture 3D-printed showed that the surface microhardness was significantly lower for all cleansers (P < 0.05). CONCLUSIONS: Listerine demonstrated superior efficacy in reducing Candida albicans with minimal effect on denture properties, whereas 1% NaOCl had a significant negative impact on the properties. The mechanical properties were significantly lower in 3D-printed resin than in other resins for all denture cleansers. CLINICAL RELEVANCE: Denture base materials are being sold to adapt to the CAD/CAM system, increasing the number of users of dentures manufactured with this system. Despite this, there is little investigation into denture cleaners regarding the adhesion capacity of microorganisms and the optical, surface and mechanical properties of dentures, thus requiring further investigation.


Subject(s)
Candida albicans , Computer-Aided Design , Denture Bases , Denture Cleansers , Materials Testing , Printing, Three-Dimensional , Surface Properties , Candida albicans/drug effects , Denture Bases/microbiology , Denture Cleansers/pharmacology , Hardness , Flexural Strength , Dental Materials/chemistry
12.
Dent Mater ; 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38926014

ABSTRACT

PURPOSE: This study aimed to reproduce and translate clinical presentations in an in vitro set-up and evaluate laboratory outcomes of mechanical properties (flexural strength, fatigue resistance, wear resistance) and link them to the clinical outcomes of the employed materials in the Radboud Tooth Wear Project (RTWP). MATERIALS AND METHODS: Four dental resin composites were selected. 30 discs (Ø12.0 mm, 1.2 mm thick) were fabricated for each of Clearfil TM AP-X (AP), Filtek TM Supreme XTE (FS), Estenia TM C&B (ES), and Lava Ultimate (LU). Cyclic loading (200 N, 2 Hz frequency) was applied concentrically to 15 specimens per group with a spherical steatite indenter (r = 3.18 mm) in water in a contact-load-slide-liftoff motion (105 cycles). The wear scar was analysed using profilometry and the volume loss was digitally computed. Finally, all specimens were loaded (fatigued specimens with their worn surface loaded in tension) until fracture in a biaxial flexure apparatus. The differences in volume loss and flexural strength were determined using regression analysis. RESULTS: Compared to AP and FS, ES and LU showed a significantly lower volume loss (p < 0.05). Non-fatigued ES specimens had a similar flexural strength compared to nonfatigued AP, while non-fatigued FS and LU specimens had a lower flexural strength (p < 0.001; 95 %CI: -80.0 - 51.8). The fatigue test resulted in a significant decrease of the flexural strength of ES specimens, only (p < 0.001; 95 %CI: -96.1 - -54.6). CLINICAL RELEVANCE: These outcomes concur with the outcomes of clinical studies on the longevity of these composites in patients with tooth wear. Therefore, the employed laboratory test seems to have the potential to test materials in a clinically relevant way.

13.
Prim Dent J ; 13(2): 53-57, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38888075

ABSTRACT

A technique is outlined for utilising a polymeric composite reinforced with glass fibres in a three-dimensional mesh as a post-core in aesthetic cases. The clinical procedure involves obtaining an impression of the root canal space, scanning the definitive cast, and milling a fibre-reinforced composite post-core. Subsequently, the intra-radicular post-core is cemented using an adhesive resin cement. The use of custom-made computer-aided design-computer-aided manufacturing (CAD-CAM) fibre-reinforced composite post-core facilitates repairability, provides better adaptation to the root canal space, avoids uneven cement thickness, ensures chemical adhesion to resin cement, and promotes favourable aesthetics when combined with all-ceramic crowns.


Subject(s)
Composite Resins , Computer-Aided Design , Dental Prosthesis Design , Glass , Post and Core Technique , Humans , Composite Resins/chemistry , Glass/chemistry , Resin Cements/chemistry , Crowns , Esthetics, Dental , Dental Prosthesis Retention , Dental Materials/chemistry , Cementation
14.
J Clin Med ; 13(11)2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38893040

ABSTRACT

Background: In everyday dentistry, monolithic single crowns can be cemented with self-adhesive resin cements. The aim of this in vitro study was to evaluate how the marginal adaptation of full monolithic zirconia-reinforced lithium silicate (ZLS) single crowns is influenced by three different self-adhesive resin cements. Methods: Forty-five typodont teeth fully prepared for full monolithic crowns were divided into three groups (fifteen each) for the use of three different self-adhesive resin cements. A fourth control group (Temp-bond) was created by taking five teeth from each group before cementation with self-adhesive resin cements. All forty-five abutments were scanned using a Primescan intra-oral scanner (IOS), followed by computer-aided design (CAD) and computer-aided manufacturing (CAM) of zirconia-reinforced lithium silicate (ZLS) full crowns using a four-axis machine. Initially, the crowns of the control group were fixed to the abutments using Temp-bond, and the marginal gap was evaluated using a scanning electron microscope (SEM). After removing the control group crowns from the abutments, fifteen crowns in each group were cemented using a different self-adhesive resin cement and observed under SEM for evaluation of the marginal gap. A Kolmogorov-Smirnov test was performed, indicating no normal distribution (p < 0.05), followed by Mann-Whitney tests (α = 0.05). Results: The total mean marginal gap of the temp-bond control group was significantly lower compared to all three groups of self-adhesive resin cement (p < 0.0005). The total mean marginal gap of the G-cem ONE group was significantly lower compared to the TheraCem group (p < 0.026) and RelyX U200 group (p < 0.008). The total mean marginal gap of the TheraCem group was significantly higher than the G-cem ONE group (p < 0.026) but showed no significant difference with the RelyX U200 group (p > 0.110). Conclusions: All four groups showed a clinically acceptable marginal gap (<120 microns). Although all three groups of self-adhesive resin cement showed a significant increase in the marginal gap compared to the temp-bond control group, they were within the limits of clinical acceptability. Regarding the marginal gap, in everyday dentistry, it is acceptable to use all three self-adhesive resin cements, although the G-cem ONE group exhibited the lowest marginal gap for ZLS single crowns.

15.
BMC Oral Health ; 24(1): 671, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38851680

ABSTRACT

The latest generation of intraoral scanners can record the prosthetic field with relative ease, high accuracy and comfort for the patient, and have enabled fully digital protocols for designing and manufacturing complete dentures. The present study aims to examine the intaglio surface trueness of 3D printed maxillary dentures produced by fully digital workflow in comparison with dentures produced by analogue clinical and laboratory prosthetic workflow. The edentulous maxillary arch of 15 patients was scanned with an intraoral scanner as well as the intaglio of the delivered conventional denture. The scan of the edentulous arch was imported into a dental design software to produce the denture base which was then 3D printed. The intaglio surface of the finished 3D printed denture bases was digitized and used to assess the trueness of the printed denture bases compared to the intaglio surface of the conventional dentures as well as performing a trueness comparison in relation to the scanned edentulous arches. The dataset (n = 30) was subjected to Kruskal-Wallis test analysis, the significance level being established at α = 0.05. The results of the study showed that the printed group displayed better trueness values with a median of 176.9 µm while the analogue group showed a median of 342 µm. Employing a fully digital workflow to produce 3D-printed denture bases yields a consistent and precise manufacturing method when accounting for the intaglio surface of the denture.


Subject(s)
Denture Bases , Denture Design , Printing, Three-Dimensional , Workflow , Humans , Denture Design/methods , Computer-Aided Design , Female , Jaw, Edentulous , Denture, Complete, Upper
16.
Cureus ; 16(5): e59936, 2024 May.
Article in English | MEDLINE | ID: mdl-38854191

ABSTRACT

In layered zirconia prosthesis, the choice of zirconia composition, framework design, and shade is closely related to the properties of the abutments. This interdependence emphasizes how crucial it is to take a deliberate and tailored approach to meet the unique needs of every therapeutic circumstance. To successfully treat anterior teeth and achieve restorations that look natural, challenges such as incorrect size and shape, atypical gingival contour, and unsightly hues need to be resolved. Ceramodetal restorations have occasionally allowed for the most appealing, authentic replication of natural teeth, despite its proven strength, endurance, and improved aesthetics. Due to their superior cosmetic results, metal-free materials have been used for anterior rehabilitation. Materials like dental zirconia, which offers excellent aesthetics and desired mechanical characteristics, have emerged in response to the increased need for visually appealing and metal-free alternatives. In this case study context, experiences in the clinic using multilayer zirconia prostheses intended exclusively for anterior teeth are discussed.

17.
Article in English | MEDLINE | ID: mdl-38864592

ABSTRACT

Restorative material selection has become increasingly challenging due to the speed of new developments in the field of dental material science. The present narrative review gives an overview of the current indications for implant abutments and restoration materials for provisional and definitive implant-supported fixed dental prostheses in partially edentulous patients. For single implant restorations, titanium base abutments for crowns are suggested as an alternative to the conventional stock- and customized abutments made out of metal or zirconia. They combine the mechanical stability of a metallic connection with the esthetic potential of ceramics. For multiple-unit restorations, conical titanium bases especially designed for bridges are recommended, to compensate for deviating implant insertion axes and angulations. Even though titanium base abutments with different geometries and heights are available, certain clinical scenarios still benefit from customized titanium abutments. Indications for the definitive material in fixed implant restorations depend on the region of tooth replacement. In the posterior (not esthetically critical) zone, ceramics such as zirconia (3-5-Ymol%) and lithium-disilicate are recommended to be used in a monolithic fashion. In the anterior sector, ceramic restorations may be buccally micro-veneered for an optimal esthetic appearance. Lithium-disilicate is only recommended for single-crowns, while zirconia (3-5-Ymol%) is also recommended for multiple-unit and cantilever restorations. Attention must be given to the specific mechanical properties of different types of zirconia, as some feature reduced mechanical strengths and are therefore not indicated for all regions and restoration span lengths. Metal-ceramics remain an option, especially for cantilever restorations.

18.
Cureus ; 16(5): e60389, 2024 May.
Article in English | MEDLINE | ID: mdl-38883050

ABSTRACT

BACKGROUND: Digital dentistry has revolutionized the field of implant dentistry, offering enhanced accuracy and precision in implant placement and prosthesis fabrication. This study aims to evaluate the effect of digital dentistry on the accuracy of implant placement and prosthesis fit through a comprehensive in-vitro assessment. METHODS: In this in-vitro study, a Digital Dentistry Group and a Conventional Group were compared regarding implant placement accuracy and prosthesis fit. Measurements of coronal deviation, apical deviation, global deviation, angulation deviation, and depth deviation were obtained for implant placement accuracy, while marginal fit and internal fit were assessed for prosthesis fit. Statistical analysis was performed to determine significant differences between the two groups. RESULTS: The Digital Dentistry Group demonstrated significantly lower values of coronal deviation, apical deviation, global deviation, angulation deviation, and depth deviation compared to the Conventional Group (p < 0.001). Similarly, the Digital Dentistry Group exhibited superior marginal fit and internal fit (p < 0.001) when compared to the Conventional Group. CONCLUSION: This in-vitro study provides evidence supporting the superior accuracy of implant placement and improved prosthesis fit achieved through digital dentistry techniques. The use of intraoral scanners, computer-aided design/computer-aided manufacturing (CAD/CAM) systems, and three-dimensional (3D) imaging enables precise digital impressions, virtual planning, and custom-made prostheses with superior fit and esthetics. Incorporating digital dentistry into clinical practice can enhance treatment outcomes and patient satisfaction in implant dentistry.

19.
Saudi Dent J ; 36(6): 920-925, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38883892

ABSTRACT

Background: Comparative studies of interim veneer restorations crafted using subtractive computer-aided manufacturing (s-CAM) milling technology and traditional direct hand-made approaches are needed. Purpose: This comparative in vitro study evaluated the fracture resistance of two types of provisional veneer restorations for maxillary central incisors: milled (s-CAM) and traditional direct hand-made bis-acryl veneers. Materials and methods: Fifty maxillary right central incisor veneers (25 specimens per group) were fabricated and divided according to the fabrication method: (1) s-CAM milled (Structure CAD, VOCO Dental); and (2) hand-made (Protemp Plus, 3M). The restorations were cemented onto 3D-printed resin dies using temporary cement and subjected to 1000 cycles of thermal cycling between 5° and 55 °C. These restorations subsequently were subjected to compressive loading until fracture occurred. Images of the fractured samples were captured using a scanning electron microscope (SEM). Statistical analysis was performed using the one-way ANOVA test and the Mann-Whitney U test. Results: Significant differences (p < 0.001) in the fracture resistance were observed between the two groups. s-CAM milled interim veneers displayed higher fracture resistance values (439.60 ± 26 N) compared to the traditional method (149.15 ± 10 N). Conclusion: The manufacturing method significantly influences the fracture resistance of interim veneer restorations. s-CAM interim laminate veneer restorations for maxillary central incisors exhibit a fracture resistance superior to that of the traditional method using bis-acryl.Clinical relevanceClinicians should consider CAD/CAM milled veneers for scenarios demanding long-term interim restoration and the withstanding of high occlusal forces.

20.
Dent Mater J ; 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38825451

ABSTRACT

Highly polished 3, 4, and 5 mol% yttria-stabilized zirconia and CAD/CAM composite resin samples were prepared, and the influence of surface roughness (Ra and Sa, 21 areas/group), wettability (contact angle and surface energy, 3 samples/group), and surface chemical composition (2 samples/group) on single-strain bacterial adhesion models (Porphyromonas gingivalis, Streptococcus oralis, Streptococcus sanguinis, Streptococcus gordonii, and Streptococcus mutans) were compared via fluorescent staining with graphical analysis (21 areas/group). Statistical analysis was performed using the Shapiro-Wilk test followed by one-way analysis of variance with Tukey's test or the Kruskal-Wallis test with Dunn's test (α=0.05) and linear regression. For dental zirconia with the same surface roughness, the yttria content did not significantly influence the initial bacterial adhesion. However, higher bacterial adhesion was detected for the composite resin owing to its high C, O, and Si contents. There was no correlation between surface energy and bacterial adhesion for any bacterial strain (p<0.005).

SELECTION OF CITATIONS
SEARCH DETAIL
...