Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.081
Filter
1.
Surg Radiol Anat ; 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38856943

ABSTRACT

PURPOSE: The suprapatellar bursa is located in the proximal deep layer of the patella and is thought to reduce tissue friction by changing from a single-membrane structure to a double-membrane structure during knee joint motion. However, the dynamics of the suprapatellar bursa have only been inferred from positional relationships, and the actual dynamics have not been confirmed. METHODS: Dynamics of the suprapatellar bursa during knee joint motion were observed in eight knees of four Thiel-fixed cadavers and the angle at which the bursa begins to show a double membrane was revealed. The flexion angles of knee joints were measured when the double-membrane structure of the suprapatellar bursa began to appear during knee joint extension. RESULTS: The suprapatellar bursa changes from a single membrane to a double-membrane structure at 91 ± 4° of flexion, when the knee joint is moved from a flexed position to an extended position. CONCLUSION: The suprapatellar bursa may be involved in limitations to knee joint range of motion and pain at an angle of approximately 90°. Further studies are needed to verify whether the same dynamics are observed in living subjects.

2.
Cureus ; 16(5): e59637, 2024 May.
Article in English | MEDLINE | ID: mdl-38832166

ABSTRACT

INTRODUCTION: Anatomical preservation and functional integrity of the facial nerve (FN) are the main concerns of parotid surgery. Even though a variety of anatomical landmarks have been proposed and widely utilized, temporal or permanent postoperative FN palsy is still a significant comorbidity of parotid surgery. Therefore, the literature must fully elucidate the consistency of the anatomical relationship between the FN and the retromandibular vein (RMV). METHODS: We conducted a cadaveric study of 24 hemifaces to map the relationship between the FN and the RMV. Three distinct patterns were identified. Fourteen of the hemifaces were males, and 10 were females. Thirteen cadaveric dissections were performed on the right side and 11 on the left side. RESULTS: Our study found three distinct patterns and proposed a classification system. Type I (66.7%) is when the nerve lies exclusively lateral to the RMV. Type II (29.2%) is when the FN lies superficial to the RMV, but its mandibular branch lies deep to the anterior branch of the RMV, and type III (4.1%) is when the FN lies exclusively medial to the RMV. CONCLUSION: The FN and RMV relationship is not constant, and surgeons should be aware of every anatomical variation. Especially in cases where the FN is estimated to lie more in-depth to the level of the RMV, a retrograde approach may be required to avoid a FN injury.

3.
Article in English | MEDLINE | ID: mdl-38824006

ABSTRACT

The primary objective of this cadaver study was to assess the feasibility of a novel custom helical distraction system and a patient-specific antral maxillary distractor. The study involved two fresh cadaver heads and followed a systematic procedure. First, virtual planning was conducted for an asymmetric maxillomandibular advancement. Custom patient-specific hardware was then fabricated to enable sequential mandibular advancement and gradual maxillary distraction. The mandibular lengthening procedures were found to be highly accurate, with only minor deviations from the planned results. In terms of maxillary distraction, the patient-specific antral distractors demonstrated favorable outcomes, with two noteworthy exceptions. Ideal forward maxillary advancement was short by a modest 2-3 mm in both cadavers. Additionally, cadaver 2 exhibited an unplanned pitch malrotation. However, an excellent occlusion was achieved in cadaver 1 and an acceptable anterior occlusion in cadaver 2, albeit with bilateral posterior open bites that could be readily corrected with interdental elastics in a clinical setting. This cadaver model study provides compelling evidence for the feasibility of patient-specific antral helical distractors, highlighting their potential to yield positive outcomes. Importantly, the study results suggest that patient-specific antral distractors may offer superior results compared to the current standard of linear distractors.

4.
Article in English | MEDLINE | ID: mdl-38837465

ABSTRACT

AIM: The aim of this study on native human cadavers was to compare clinical, sonographic, and radiological measurements of fenestrations, dehiscences, and 3-wall bone defects on implants. MATERIALS AND METHODS: The examination was carried out on five human mandibles. After the insertion of 27 implants, dehiscences (n = 14), fenestrations (n = 7) and 3-wall bone defects (n = 6) were prepared in a standardized manner. The direct measurement of the bone defects was carried out with a periodontal probe and the radiological examination was carried out using digital volume tomography (DVT). The ultrasound examination (US) was performed using a clinical 24-MHz US imaging probe. Means and standard deviations of the direct, US, and DVT measurements were calculated. Measurements were statistically compared using the Pearson correlation coefficient and Bland-Altman analysis. RESULTS: Bone defects were on average 3.22 ± 1.58 mm per direct measurement, 2.90 ± 1.47 mm using US, and 2.99 ± 1.52 mm per DVT assessment. Pairwise correlations of these measurements were R = .94 (p < .0001) between direct and US, R = .95 (p < .0001) between DVT and US, and R = .96 (p < .0001) between direct and DVT. The mean differences of the measurements (and 95% CI) between direct and US was 0.41 (-0.47 to 1.29), US and DVT 0.33 (-0.30 to 0.97), and direct and DVT 0.28 (-0.50 to 1.07). CONCLUSION: All peri-implant bone defects could be identified and sonographically measured. US measurements showed a strong correlation with direct and DVT measurements. The sonographic measurement accuracy was highest for dehiscences, followed by fenestrations and 3-wall bone defects.

5.
Surg Radiol Anat ; 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38858315

ABSTRACT

PURPOSE: Our study aims to investigate three parts of the intracranial cavity, their distances to essential anatomical landmarks, and the correlations between these distances with sex, laterality, and surgical significance. METHODS: The cranial nerve foraminae and essential surgical landmarks of each fossa were investigated bilaterally in 30 adult formalin-fixed cadaveric heads. Measurements, including lengths, depths, diameters, and horizontal distances to each other, to the midline of the skull, and to the outer lateral margin of the skull, were recorded on both sides. RESULTS: The optic canal (OC) depth, internal auditory meatus (IAM) width, CNVII and CNIX diameters, and accessory hypoglossal canal (HC) distance were significantly greater on the left side (p < 0.05). CNVI length, CNV diameter, CNXI length, and the distances of the HC and accessory HC from the skull were significantly greater on the right side (p < 0.05). In males, correlations were found between the length of the left CNVIII and the right IAM diameter (r = 0.864, p = 0.001), right CNVIII length (r = 0.709, p = 0.022), right accessory HC length (r = 0.847, p = 0.016), and right-sided skull distance (r = 0.829, p = 0.042). In females, correlations were noted between IAM depth and length, right IAM location relative to the skull, left CNIX and CNX lengths, left CNXII length, left accessory HC location relative to the skull, and accessory HC length. CONCLUSIONS: The findings of the current study indicate inherent asymmetry, sexual dimorphism, and variability in certain cranial nerves among cadaveric heads, which could have implications for surgical procedures, neuroanatomical studies, and clinical assessments. The study revealed side disparities and correlations within cranial fossa formations and essential surgical landmarks in both genders.

6.
Rev Bras Ortop (Sao Paulo) ; 59(3): e409-e414, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38911877

ABSTRACT

Objective To identify the location of the Riché-Cannieu anastomosis (RCA) in relation to the Cardinal Kaplan Line (KCL) and the Y line. Methods A total of 20 hands of 10 recently-deceased adult male cadavers aged between 27 and 66 years were dissected for the investigation of the relationship of the most distal point of the RCA with the KCL and with the Y line, drawn from the axis of the third metacarpal head, following the longitudinal axis of the hand. Results In 20 limbs, the most distal point of the nerve communication was positioned distally in relation to the KCL. The Y line was positioned on the radial side in relation to the most distal point of the RCA in 14 limbs, and it was positioned on the ulnar side in relation to the Y line in 6 limbs. The crossing between the KCL and the Y line occurred proximal to the RCA in 18 limbs; in 1 hand, it was positioned distal to the intersection between these lines; and in another hand, the KCL was positioned exactly on the RCA. Conclusion Knowledge of these anatomical relationships can prevent damage to nerve branches and thus also prevent paralysis of intrinsic muscles in surgical procedures in the palm of the hand.

7.
Anat Cell Biol ; 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38916082

ABSTRACT

The 7th cervical vertebra (C7) is described as having the most prominent spinous process (SP) and is characterized as the "vertebra prominens" (VP) of the cervical spine in anatomy textbooks. The VP is an important anatomical landmark of the neck for clinical examination and therapeutic intervention. The present study identifies the level of the most prominent SP of the cervical and uppermost thoracic vertebrae in a cadaveric cohort. Thirty-nine (23 female and 16 male) cadavers of a mean age of 77.5 years were investigated in a prone position and a certain cervical kyphotic bending. The most prominent SP, at the base of the neck, was palpated and marked with a wedging nail into the SP of the vertebra. The cervical region was dissected, and a blind investigator examined whether the nail was placed into the SP of C7 or the SP of another upper or lower vertebra. In 19 out of 39 cadavers (48.7%), the C7 was identified as the VP (typical anatomy), followed by the C6 (in 14 cadavers, 35.9%), C5 (in 4 cadavers, 10.3%). In 2 cadavers (5.1%) the first thoracic vertebra was identified as having the most prominent SP. Although C7 is described as the VP, in the present study the SP of C7 was the most prominent in less than 50%. The high variable projection level of the most prominent SP of the cervical vertebra holds great clinical significance for spine examination, neck surgery, and spinal anesthesia.

8.
J Anaesthesiol Clin Pharmacol ; 40(2): 276-282, 2024.
Article in English | MEDLINE | ID: mdl-38919433

ABSTRACT

Background and Aims: Simulation is increasingly used in medical teaching. Various studies have evaluated different simulation models for training of regional anesthesia (RA). We compared the use of human cadaver and blue phantom models for training of regional anesthesia to novice postgraduate students of anesthesiology. Material and Methods: Fifty students were taught knobology of the ultrasonography (USG) machine. They were divided into two equal groups by computer-generated random number table, and the groups assigned were kept in sealed envelopes. In group BP, students were trained on a blue phantom model, and in group HC, students were trained on human cadaver. After training, a didactic video of sonoanatomy of the supraclavicular block was shown to all participants. The block performance was then judged on patients requiring supraclavicular block. The primary objective of the study was to compare the block performance time, and secondary objectives were the quality of image acquired, orientation of transducer to the target, identification of ultrasound artifacts, errors committed, complications, and success rate. Results: The mean block performance time was shorter in group HC compared to group BP (451.96 ± 50.25 and 526.48 ± 43.486 s, respectively; P < 0.001). The image quality score, transducer orientation to the target, and identification of USG artifacts were better in group HC compared to group BP, with lesser number of needle passes. Conclusion: Cadaver-based training produced better results compared to blue phantom simulator model for teaching of ultrasound-guided RA to novice postgraduate trainees of anesthesiology.

9.
Ann Biomed Eng ; 2024 Jun 23.
Article in English | MEDLINE | ID: mdl-38910203

ABSTRACT

Instrumented mouthguard systems (iMGs) are commonly used to study rigid body head kinematics across a variety of athletic environments. Previous work has found good fidelity for iMGs rigidly fixed to anthropomorphic test device (ATD) headforms when compared to reference systems, but few validation studies have focused on iMG performance in human cadaver heads. Here, we examine the performance of two boil-and-bite style iMGs in helmeted cadaver heads. Three unembalmed human cadaver heads were fitted with two instrumented boil-and-bite mouthguards [Prevent Biometrics and Diversified Technical Systems (DTS)] per manufacturer instructions. Reference sensors were rigidly fixed to each specimen. Specimens were fitted with a Riddell SpeedFlex American football helmet and impacted with a rigid impactor at three velocities and locations. All impact kinematics were compared at the head center of gravity. The Prevent iMG performed comparably to the reference system up to ~ 60 g in linear acceleration, but overall had poor correlation (CCC = 0.39). Prevent iMG angular velocity and BrIC generally well correlated with the reference, while underestimating HIC and overestimating HIC duration. The DTS iMG consistently overestimated the reference across all measures, with linear acceleration error ranging from 10 to 66%, and angular acceleration errors greater than 300%. Neither iMG demonstrated consistent agreement with the reference system. While iMG validation efforts have utilized ATD testing, this study highlights the need for cadaver testing and validation of devices intended for use in-vivo, particularly when considering realistic (non-idealized) sensor-skull coupling, when accounting for interactions with the mandible and when subject-specific anatomy may affect device performance.

10.
Clin Anat ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38845406

ABSTRACT

This study aimed to evaluate the superficial medial collateral ligament distal tibial attachment (sMCL-dTA) morphologically and morphometrically. Seventeen unpaired formalin-fixed cadaveric knees were used. The sMCL was divided into anterior and posterior sections in the paracoronal plane along the midline of the sMCL. The distance from the medial edge of the tibial plateau and the joint line to the proximal margin, center, and distal margin of the sMCL-dTA and the length of the sMCL-dTA were measured in the anterior section, respectively. The sMCL-dTA was histologically observed in the posterior section with hematoxylin and eosin and Masson's trichrome staining. The distance from the medial edge of the tibial plateauto the proximal margin, center, and distal margin of the sMCL-dTA were 38.1 ± 4.2, 49.7 ± 4.4, and 61.5 ± 5.1 mm, respectively. The perpendicular distance from the joint line to the proximal margin, center, and distal margin of the sMCL-dTA were 36.1 ± 4.0, 47.4 ± 4.2, and 59.1 ± 4.8 mm, respectively. The length of the sMCL-dTA was 23.6 ± 3.2 mm. Histologically, the sMCL-dTA was formed by two layers of collagen fibers: the unidirectional fibrous layer and the multidirectional fibrous layer. The respective thicknesses of the two layers both decreased distally. The anatomical location, the length, and the attachment morphology of sMCL-dTA have been clarified using human cadaveric knees. Anatomical data in the present study contribute to the quality of surgery associated with sMCL-dTA.

11.
JSES Int ; 8(3): 546-550, 2024 May.
Article in English | MEDLINE | ID: mdl-38707574

ABSTRACT

Background: The deltoid is a trisegmented muscle with anterior, middle, and posterior components. While the clinical relevance of the presence of anatomic variations of the deltoid origin and insertion continues to be debated, the architecture of the deltoid muscle is more complex than initially believed. This study aimed to evaluate the gross anatomy of the deltoid muscle insertion by qualitatively and quantitatively characterizing the insertion and location of the deltoid muscle's anterior, middle, and posterior components. This information is valuable to surgeons as it raises awareness of potential variants that could be encountered during surgery, promotes mindfulness of neurovascular proximities, and reduces the likelihood of confusion between adjacent muscle fibers. Methods: Eight nonpaired, fresh-frozen clavicle-to-fingertip cadaveric shoulders were acquired for the study (6 left, 2 right). The average age of the cadavers was 79.5 years (range: 64-92). The standard deltopectoral approach was carried out on all specimens. The planes dividing the anterior, middle, and posterior deltoid were identified and marked. Once complete exposure had been achieved, digital calipers were used to record the size of the deltoid insertion. The specimens were qualitatively assessed to characterize the style of insertion they demonstrated. Results: The average length of the deltoid insertion was 39.45 ± 9.33 mm (n = 8). Six of the eight shoulders demonstrated an insertion style previously characterized in the literature. The remaining two shoulders highlighted an insertion pattern not previously described. Conclusion: The current study demonstrates a novel insertion pattern for the deltoid muscle that has not been previously characterized. This "step-off" insertion pattern shows that the anterior, middle, and posterior tendons are inserted superior-medial, directly on, and inferior-lateral to the deltoid tuberosity and was found in 2/8 of our cadaveric specimens.

12.
J Neurol Surg B Skull Base ; 85(3): 221-226, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38721367

ABSTRACT

Objective We completed a prospective human cadaveric study to determine the ability of a ball bearing (BB) pellet to penetrate the orbit and/or surrounding structures. Methods A single trained sergeant officer discharged an alloy steel air rifle to eight cadaver orbits from four adult human cadaver heads. Five BB pellets each were aimed at three locations (caruncle, upper eyelid, or lower eyelid) at 10 cm and 1 m, and then less specifically, at the orbital region for 3- and 5-m distances. Computed tomography (CT) of the cadaver heads was performed. Final locations of BB pellets are divided into three categories: intracranial, surrounding orbital structures including the pterygopalatine fossa and infratemporal fossa, and orbit. Results Of 40 BB pellets, 37 penetrated soft tissue and were visualized on CT: 19 (51%) rested in the intracranial space, 17 (46%) in surrounding orbital structures, and 1 (3%) within the orbit. The deepest position of a pellet was in the parietal lobe, and most superficial location anterior to the frontal bone. Pellets discharged from 1 m were more likely to rest in the intracranial space compared with those from 10 cm ( p < 0.001), 3 m ( p = 0.011), and 5 m ( p = 0.004). The distance of discharge was associated with final pellet location ( p = 0.001). Conclusion BB guns should be considered dangerous and potentially deadly when aimed at the orbit. Although the thick calvarium can protect the intracranial space from BB penetration, the orbit may be a vulnerable entry point with relatively low resistance, allowing penetration of the intracranial and periorbital spaces.

13.
Indian J Anaesth ; 68(5): 500-503, 2024 May.
Article in English | MEDLINE | ID: mdl-38764959

ABSTRACT

Dermatomal analgesia achieved with quadratus lumborum blocks is site-dependent and inconsistent. Cadaveric and clinical studies reveal multiple mechanisms of action. We dissected six fresh human cadavers bilaterally and thoroughly studied their neurological linkages to the quadratus lumborum muscle (QLM) to identify neural structures and block targets. At the end of the investigation, only the subcostal nerve (anterolateral) and the ilioinguinal nerves were found near the QLM in all specimens. The iliohypogastric nerve was found in only two specimens. No further neural targets were found in the fascial planes before and posterior to the QLM.

14.
J Man Manip Ther ; : 1-7, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38768018

ABSTRACT

OBJECTIVES: To assess needle placement accuracy in the rectus abdominis (RA) muscle during dry needling (DN) without entering the peritoneum. METHODS: Two physical therapists performed DN on a cadaver, making 10 attempts each to needle the RA without entering the peritoneum. Techniques followed two common DN approaches. Ultrasound verified needle depth and safety. RESULTS: Seventy percent of attempts were recorded as safe needle placement, while 30% were unsafe. Accurate RA needle placement without peritoneal entry occurred in 55% of attempts. DISCUSSION/CONCLUSION: Inadvertent peritoneal needle placement during RA DN poses risks regardless of experience. Ultrasound guidance may enhance safety and precision in clinical practice.

15.
Foot Ankle Surg ; 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38692981

ABSTRACT

BACKGROUND: Insertional Achilles tendinopathy (IAT) is a common pathology with multiple surgical interventions available for treatment. The Zadek, dorsal closing wedge calcaneal osteotomy (ZO) has been demonstrated to be effective treatment of IAT. There have been various recommendations in the literature as to what measurement of wedge removal should be considered ideal to produce greatest postoperative range of motion (ROM), thus postoperative biomechanical potential. Accordingly, the purpose of this cadaveric study was to assess the range of motion achieved after various measurements of wedge removal by ZO. METHODS: The ZO was performed on six cadaveric specimens. A 7.5 mm and 15 mm wedge osteotomy was marked and sequentially completed on each specimen. Lateral fluoroscopic imaging was utilized to take preoperative and postoperative ROM measurements for each osteotomy. Dorsiflexion (DF) and plantarflexion (PF) ROM arcs were measured for each wedge size and compared by t-test. Effect sizes were calculated by Cohen's d analysis. RESULTS: Maximal DF was 110.87 ± 12.97 deg in the pre-osteotomy state. Removal of a 7.5 mm wedge improved DF by 8 deg to a mean 102.93 ± 13.81 deg (p = 0.08). Removal of a 15 mm wedge improved DF by 16 deg to a mean 95.96 ± 11.41 deg (p = 0.003). Cohen's d and effect size calculation demonstrated a 7.5 mm wedge to have a small effect on DF, while a 15 mm wedge had a medium effect (0.29, 0.52 respectively). Maximal PF did not change significantly amongst the pre-osteotomy, 7.5 mm wedge, or 15 mm wedge positions. ICC was 0.96. CONCLUSION: Based on the results presented in this study, removal of a 15 mm wedge with ZO yields significant and greater improvement in ROM than a 7.5 mm wedge. We hope the current study will better inform preoperative planning for ZO. STUDY TYPE: Prospective Cadaver Study. LEVEL OF EVIDENCE: V.

16.
North Clin Istanb ; 11(2): 127-132, 2024.
Article in English | MEDLINE | ID: mdl-38757109

ABSTRACT

OBJECTIVE: Early and accurate diagnosis of brain death in intensive care units (ICU) is essential for organ transplantation. This study aimed to evaluate the cases diagnosed with brain death in the ICU of a tertiary center in Istanbul. METHODS: The cases diagnosed as brain death in the ICU during the ten years between January 2013 and September 2022 were evaluated retrospectively. The demographic characteristics of the patients, the diagnosis of hospitalization in the ICU, the time from arrival to the ICU until the diagnosis of brain death, the somatic survival time after the diagnosis of brain death, the acceptance rate of organ donation by the families and the organs removed were evaluated. RESULTS: A total of 44 patients were diagnosed with brain death. The mean age of the cases was 39.7±17.4 years, and 63% were male. The most common hospitalization diagnosis was intracranial hemorrhage (81.8%). Traffic accidents, hypertensive and aneurysm-related hemorrhages, gunshot wounds, and falls from height were the most common causes of intracranial hemorrhage. Patients were admitted to the ICU most frequently from the emergency department (54%). The mean time to brain death was 7.9±6.2 days, and the somatic survival time was 1.9±1.9 days in patients who did not receive organ transplantation. While the apnea test was positive in 91% of the cases, the apnea test could not be completed in 9% of the cases. While relatives of 7% (n=3) of the cases accepted organ donation, a patient was not allowed to be an organ donor for medical reasons. Organ transplantation was performed in two patients (5%). CONCLUSION: As in the whole world, getting treatment as soon as possible for the patients waiting on the organ transplant list in Turkiye by increasing the number of organs to be obtained from cadavers. In cases with suspected brain death in the ICU, diagnosing brain death as soon as possible and conducting family interviews with trained organ transplant coordinators will increase the number of cadaver donors. However, we think policies should be developed to ensure that society is informed and encouraged about brain death and organ donation.

17.
J Hand Surg Glob Online ; 6(3): 355-362, 2024 May.
Article in English | MEDLINE | ID: mdl-38817753

ABSTRACT

Purpose: Repair of perilunate dislocations requires stabilization of the carpal bones, although there is limited research on the preferred method(s) of stabilization. We compared the biomechanical characteristics of K-wire versus staple fixation of scapholunate (SL) and lunotriquetral (LT) intervals in the wrist. Methods: After creating a grade IV instability model, 20 cadaver wrists were randomized into 2 stabilization model groups using K-wires or surgical staples across the SL and LT intervals. For each ligament, two K-wires or one surgical staple was used to stabilize the proximal carpal row. Each wrist was loaded with 15 N of force and cycled 5,000 times at an angular velocity of 10 rpm. Displacement between bones was measured at different cycles (10, 100, 500, 1,000, 2,000, 3,000, 4,000, and 5,000). A t test was used for comparisons. Results: For the LT K-wire group, the average displacement at 10 cycles was 0.08 mm, and at 5,000 cycles, 0.163 mm. For the SL K-wire group, the average displacement at 10 cycles was 0.025 mm, and at 5,000 cycles, 0.129 mm. For the LT and SL staple fixation models, the average shifts at 10 cycles were 0.029 and 0.063 mm, and at 5,000 cycles, 0.098 and 0.176 mm, respectively. No significant difference between the fixation models was found at any interval. Notably, in each group, a similar number of small outliers with higher amounts of displacement was observed. Conclusions: Either K-wire or surgical staple stabilization is suitable for perilunate dislocations. The surgical method should be selected based on patient-specific circumstances and the provider's judgment. Type of study/level of evidence: Therapeutic III.

18.
J Hand Surg Asian Pac Vol ; 29(3): 179-183, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38726491

ABSTRACT

Background: Bennett fractures are traditionally fixed with percutaneous K-wires from dorsal to volar, or with a volar to dorsal screw via a volar open approach. While volar to dorsal screw fixation is biomechanically advantageous, an open approach requires extensive soft tissue dissection, thus increasing morbidity. This study aims to investigate the practicality and safety of Bennett fracture fixation using a percutaneous, volar to dorsal screw, particularly with regard to the median nerve and its motor branch during wire and screw insertion. Methods: Fifteen fresh frozen forearm and hand specimens were obtained from the University of Auckland human cadaver laboratory. A guidewire is placed under image intensifier from volar to dorsal with the thumb held in traction, abduction and pronation. The wire is passed through the skin volarly under image intensifier, then the median nerve is dissected from the carpal tunnel and the motor branch of the median nerve (MBMN) is dissected from its origin to where it supplies the thenar musculature. The distance between the K-wire to the MBMN is measured. Results: In 14 of 15 specimens, the wire was superficial and radial to the carpal tunnel. The mean distance to the origin of the MBMN is 6.2 mm (95% CI 4.1-8.3) with the closest specimen 1 mm away. The mean closest distance the wire gets to any part of the MBMN is 3.7 mm (95% CI 1.6-5.8); in two specimens, the wire was through the MBMN. Conclusions: Wire placement, although done under image intensifier, is subject to significant variation in exiting location. While research has shown the thenar portal in arthroscopic thumb surgery is safe, our guidewire needs to exit further ulnar to capture the Bennett fracture fragment, placing the MBMN at risk. This cadaveric study has demonstrated the proposed technique is unsafe for use.


Subject(s)
Bone Screws , Cadaver , Fracture Fixation, Internal , Humans , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/adverse effects , Bone Screws/adverse effects , Bone Wires/adverse effects , Fracture Dislocation/surgery , Fracture Dislocation/diagnostic imaging , Median Nerve/injuries , Median Nerve/surgery , Fractures, Bone/surgery
19.
Anat Sci Int ; 99(3): 326-330, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38733476

ABSTRACT

The extensor digitorum profundus complex underwent degeneration of the ulnar segments during primate adaptation and evolution. This process resulted in the preservation of only the extensor pollicis longus and extensor indicis in some apes, including humans. Consequently, anatomical variations within the digitorum profundus complex in modern humans have been well-documented, with detailed reports on their frequency and patterns in previous studies. Here, we report an unusual arrangement involving two anomalies in the extensor digitorum profundus complex, identified in a 66-year-old Japanese male cadaver. In this cadaver, two accessory muscles differentiated from both the extensor pollicis longus and extensor indicis. Notably, the latter muscle featured a tendon bifurcating towards both the thumb and index fingers, referred to as the extensor pollicis et indicis communis. Under the extensor retinaculum, the tendon of the accessory extensor pollicis longus passed through an independent compartment, whereas that of the extensor pollicis et indicis communis traversed a compartment shared by the extensor indicis and the extensor digitorum communis. Both muscles were innervated by the posterior interosseous nerve. Previous studies have reported that the accessory slip of the extensor pollicis longus and extensor pollicis et indicis communis appear at frequencies of 0.6% and 0.4-1.4%, respectively. However, to the best of our knowledge, a configuration in which both appear simultaneously has not been reported. The data from this case could provide essential insights into the variations in the extensor digitorum profundus complex in humans and non-human primates.


Subject(s)
Cadaver , Muscle, Skeletal , Tendons , Humans , Male , Aged , Muscle, Skeletal/abnormalities , Muscle, Skeletal/anatomy & histology , Tendons/abnormalities , Tendons/anatomy & histology , Fingers/abnormalities , Fingers/anatomy & histology , Anatomic Variation , Thumb/abnormalities
20.
Strabismus ; 32(2): 85-90, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38708857

ABSTRACT

INTRODUCTION: The Spiral of Tillaux describes the historically accepted insertion distances of the medial rectus, inferior rectus, lateral rectus, and superior rectus from the limbus: 5.5 mm, 6.5 mm, 6.9 mm, and 7.7 mm, respectively. The corneal diameters are historically accepted to be 11.7 mm horizontally and 10.6 mm vertically in adults. We investigated the variability of the insertion distances of the extraocular rectus muscles from the limbus as well as the corneal diameters using eyes from human cadavers and compared our measurements to these historically accepted measurements. METHODS: A sample of 60 eyes were included. For each eye, a 360 peritomy was conducted and the conjunctiva bluntly dissected to view the sclera. Muscle hooks were utilized to isolate the extraocular rectus muscles. Calipers were used to measure the insertion distances of the rectus muscles as well as the corneal diameters. RESULTS: The mean rectus muscle insertions distances from the limbus were medial 5.28 mm, inferior 5.72 mm, lateral 6.40 mm, and superior 6.78 mm. These insertion distances were shorter than the historical benchmarks (p < .01). However, observed maximum distances of the rectus muscles were all greater than the historically accepted benchmarks, with the medial, inferior, lateral, and superior rectus muscles being 6.4 mm, 7.3 mm, 7.4 mm, and 7.8 m from the limbus, respectively. The mean width and height of the cornea were 11.7 mm and 10.7 mm, respectively, and similar to the expected ranges. CONCLUSION: This study concludes that variability does exist from the historically accepted Spiral of Tillaux measurements. In addition, significant variation exists between male and female rectus muscle insertions. However, we did confirm that the rectus muscles followed the same spiral pattern described by the Spiral of Tillaux and concluded that the corneal diameters are consistent with previously accepted values.


Subject(s)
Cadaver , Cornea , Oculomotor Muscles , Humans , Female , Male , Oculomotor Muscles/anatomy & histology , Aged , Cornea/anatomy & histology , Middle Aged , Aged, 80 and over , Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...