Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 404
Filter
1.
Head Face Med ; 20(1): 33, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38760840

ABSTRACT

BACKGROUND: Dental cone beam computed tomography (CBCT) is commonly used to evaluate cancellous bone density before dental implant surgery. However, to our knowledge, no measurement approach has been standardized yet. This study aimed to evaluate the relationship between three different regions of interest (ROI) methods on cancellous bone density at the dental implant site using dental CBCT images. METHODS: Patients' dental CBCT images (n = 300) obtained before dental implant surgery were processed using Mimics (Materialise, Leuven, Belgium). At the potential implant sites, the rectangle, cylinder, and surrounding cylinder ROI methods were used to measure bone density. Repeated measures one-way analysis of variance was performed to compare the three ROI methods in terms of measurement results. Pearson correlation analysis was performed to identify the likely pair-wise correlations between the three ROI methods. RESULTS: The density value obtained using the surrounding cylinder approach (grayscale value [GV],523.56 ± 228.03) was significantly higher than the values obtained using the rectangle (GV, 497.04 ± 236.69) and cylinder (GV,493 ± 231.19) ROI methods in terms of results. Furthermore, significant correlations were noted between the ROI methods (r > 0.965; p < 0.001). CONCLUSIONS: The density measured using the surrounding cylinder method was the highest. The choice of method may not influence the trends of measurement results. TRIAL REGISTRATION: This study was approved by the Institutional Review Board of China Medical University Hospital, No. CMUH111-REC3-205. Informed consent was waived by the Institutional Review Board of China Medical University Hospital, CMUH111-REC3-205, owing to the retrospective nature of the study.


Subject(s)
Bone Density , Cone-Beam Computed Tomography , Humans , Cone-Beam Computed Tomography/methods , Female , Male , Middle Aged , Adult , Aged , Retrospective Studies , Preoperative Care/methods , Dental Implantation/methods , Young Adult , Dental Implants , Dental Implantation, Endosseous/methods
2.
Cureus ; 16(3): e57308, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38690450

ABSTRACT

In this report, we detail a 69-year-old female who sustained a comminuted intra-articular left distal radius fracture that failed to heal with bridge plate fixation. Given the patient's poor subchondral bone stock and refusal of bone autograft, we designed a construct using a dorsal spanning plate and an intramedullary fragment-specific plate as a volarly placed strut in combination with viable bone allograft and cancellous bone chips to treat this nonunion. This case demonstrates an option for distal radius non-union treatment and highlights the importance of ingenuity that orthopedic surgeons should demonstrate when trying to accommodate patients' wishes.

3.
J Stomatol Oral Maxillofac Surg ; : 101862, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38561138

ABSTRACT

This study aimed to subjectively evaluate bone quality in the particulate cancellous bone and marrow (PCBM) graft area and to assess the survival rates of implants. A retrospective review was conducted based on patient age, sex, diagnosis, reconstructed site, number of implants, prosthetic type, and duration of follow-up. Images from computed tomography (CT) before implant insertion were obtained and used in this study. We selected a 4.0-mm diameter × 8.0-mm length region of interest in the implant placement area, and measured the CT attenuation value. No significant correlations were seen between CT attenuation values and implant survival rates in the maxilla and mandible. On the other hand, CT attenuation values and implant survival rates were significantly lower in patients with malignancy than in non-malignant cases. Placing implants in PCBM grafted bone requires a full understanding of bone quality before surgery and drilling to ensure primary stability, along with consideration of soft tissue management and maintenance programs.

4.
Life (Basel) ; 14(4)2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38672738

ABSTRACT

The current protocol used to determine if an individual is osteoporotic relies on assessment of the individual's bone mineral density (BMD), which allows clinicians to judge the condition of a patient with respect to their peers. This, in essence, evaluates a person's fracture risk, because BMD is a good surrogate measure for strength and stiffness. In recent studies, the authors were the first to produce fracture toughness (FT) data from osteoporotic (OP) and osteoarthritic (OA) patients, by using a testing technique which basically analyzes the prerequisite stress conditions for the onset of growth of a major crack through cancellous bone tissue. FT depends mainly on bone quantity (BV/TV, bone volume/tissue volume), but also on bone micro-architecture (mArch), the inner trabecular design of the bone. The working research hypothesis of the present study is that mArch offers added prediction power to BV/TV in determining FT parameters. Consequently, our aim was to investigate the use of predictive models for fracture toughness and also to investigate if there are any significant differences between the models produced from samples loaded across (AC, transverse to) the main trabecular orientation and along (AL, in parallel) the trabeculae. In multilinear regression analysis, we found that the strength of the relationships varied for a crack growing in these two orthogonal directions. Adding mArch variables in the Ac direction helped to increase the R2 to 0.798. However, in the AL direction, adding the mArch parameters did not add any predictive power to using BV/TV alone; BV/TV on its own could produce R2 = 0.730. The present results also imply that the anisotropic layout of the trabeculae makes it more difficult for a major crack to grow transversely across them. Cancellous bone models and remodels itself in a certain way to resist fracture in a specific direction, and thus, we should be mindful that architectural quality as well as bone quantity are needed to understand the resistance to fracture.

5.
J Orthop Sci ; 2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38637192

ABSTRACT

BACKGROUND: When a pilot hole is made prior to a screw's insertion into bone, the same drill bit is used irrespective of the bone quality. However, osteoporotic bone is fragile and this may affect the hole diameter, which is of particular concern in cancellous bone. In this study, the relationship between bone density and drill-hole diameter was investigated assuming a pre-drilling process in screw-only osteosynthesis in the metaphysis and epiphysis. METHODS: Two types of drill bit (triple-flute [T] and quadruple-flute [Q]) with different shapes and diameters were prepared: type T bits with 3.5 mm and 4.4 mm diameters, and type Q bits with 3.5 mm and 4.2 mm diameters. Drilling was performed manually in simulated bones with four densities: 5, 10, 15, and 20 pounds per cubic foot. We measured the hole diameters with a coordinate measuring machine and analyzed the relationship between the drill-hole diameters and the densities of the simulated bones. We then compared the screw pull-out strength between the two 3.5-diameter drill bits. RESULTS: In all cases, the diameters of the drill holes were larger than those of the drill bits. The relationship between the drill-hole diameters and the bone densities was a negative linear correlation. Enlarging the hole diameter decreased the screw pull-out strength. CONCLUSIONS: For cannulated drill bits of 3.5, 4.2 and 4.4 mm diameter, the diameter of the drill hole in cancellous bone obtained by the manual drilling technique tends to be larger in low-density (e.g., osteoporotic) compared to high-density (e.g., healthy) bone.

6.
J Biomed Opt ; 29(Suppl 1): S11526, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38505736

ABSTRACT

Significance: Photoacoustic (PA) technology shows great potential for bone assessment. However, the PA signals in cancellous bone are complex due to its complex composition and porous structure, making such signals challenging to apply directly in bone analysis. Aim: We introduce a photoacoustic differential attenuation spectrum (PA-DAS) method to separate the contribution of the acoustic propagation path to the PA signal from that of the source, and theoretically and experimentally investigate the propagation attenuation characteristics of cancellous bone. Approach: We modified Biot's theory by accounting for the high frequency and viscosity. In parallel with the rabbit osteoporosis model, we build an experimental PA-DAS system featuring an eccentric excitation differential detection mechanism. Moreover, we extract a PA-DAS quantization parameter-slope-to quantify the attenuation of high- and low-frequency components. Results: The results show that the porosity of cancellous bone can be evaluated by fast longitude wave attenuation at different frequencies and the PA-DAS slope of the osteoporotic group is significantly lower compared with the normal group (**p<0.01). Conclusions: Findings demonstrate that PA-DAS effectively differentiates osteoporotic bone from healthy bone, facilitating quantitative assessment of bone mineral density, and osteoporosis diagnosis.


Subject(s)
Cancellous Bone , Osteoporosis , Animals , Rabbits , Cancellous Bone/diagnostic imaging , Ultrasonography/methods , Bone and Bones/diagnostic imaging , Bone Density , Osteoporosis/diagnostic imaging
7.
Bull Math Biol ; 86(4): 37, 2024 03 04.
Article in English | MEDLINE | ID: mdl-38436708

ABSTRACT

A two-stage model is proposed for investigating remodelling characteristics in bone over time and distance to the growth plate. The first stage comprises a partial differential equation (PDE) for bone density as a function of time and distance from the growth plate. This stage clarifies the contributions to changes in bone density due to remodelling and growth processes and tracks the rate at which new bone emanates from the growth plate. The second stage consists of simulating the remodelling process to determine remodelling characteristics. Implementing the second stage requires the rate at which bone moves away from the growth plate computed during the first stage. The second stage is also needed to confirm that remodelling characteristics predicted by the first stage may be explained by a realistic model for remodelling and to compute activation frequency. The model is demonstrated on microCT scans of tibia of juvenile female rats in three experimental groups: sham-operated control, oestrogen deprived, and oestrogen deprived followed by treatment. Model predictions for changes in bone density and remodelling characteristics agree with the literature. In addition, the model provides new insight into the role of treatment on the density of new bone emanating from the growth plate and provides quantitative descriptions of changes in remodelling characteristics beyond what has been possible to ascertain by experimentation alone.


Subject(s)
Cancellous Bone , Mathematical Concepts , Female , Animals , Rats , Models, Biological , Estrogens , Research Design
8.
Orthop Surg ; 16(5): 1215-1229, 2024 May.
Article in English | MEDLINE | ID: mdl-38520122

ABSTRACT

OBJECTIVE: The biomechanical characteristics of proximal femoral trabeculae are closely related to the occurrence and treatment of proximal femoral fractures. Therefore, it is of great significance to study its biomechanical effects of cancellous bone in the proximal femur. This study examines the biomechanical effects of the cancellous bone in the proximal femur using a controlled variable method, which provide a foundation for further research into the mechanical properties of the proximal femur. METHODS: Seventeen proximal femoral specimens were selected to scan by quantitative computed tomography (QCT), and the gray values of nine regions were measure to evaluated bone mineral density (BMD) using Mimics software. Then, an intact femur was fixed simulating unilateral standing position. Vertical compression experiments were then performed again after removing cancellous bone in the femoral head, femoral neck, and intertrochanteric region, and data were recorded. According to the controlled variable method, the femoral head, femoral neck, and intertrochanteric trabeculae were sequentially removed based on the axial loading of the intact femur, and the displacement and strain changes of the femur samples under axial loading were recorded. Gom software was used to measure and record displacement and strain maps of the femoral surface. RESULTS: There was a statistically significant difference in anteroposterior displacement of cancellous bone destruction in the proximal femur (p < 0.001). Proximal femoral bone mass explained 77.5% of the strength variation, in addition proximal femoral strength was mainly affected by bone mass at the level of the upper outer, lower inner, lower greater trochanter, and lesser trochanter of the femoral head. The normal stress conduction of the proximal femur was destroyed after removing cancellous bone, the stress was concentrated in the femoral head and lateral femoral neck, and the femoral head showed a tendency to subside after destroying cancellous bone. CONCLUSION: The trabecular removal significantly altered the strain distribution and biomechanical strength of the proximal femur, demonstrating an important role in supporting and transforming bending moment under the vertical load. In addition, the strength of the proximal femur mainly depends on the bone density of the femoral head and intertrochanteric region.


Subject(s)
Bone Density , Cancellous Bone , Tomography, X-Ray Computed , Humans , Biomechanical Phenomena , Cancellous Bone/diagnostic imaging , Cancellous Bone/physiology , Female , Male , Femur/physiology , Femur/diagnostic imaging , Aged , Middle Aged , Femur Head/diagnostic imaging , Femur Head/physiology , Cadaver
9.
Diagnostics (Basel) ; 14(5)2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38472970

ABSTRACT

BACKGROUND: Trabeculae in vertebral bodies are unequally distributed within the cervical spine (CS), the thoracic spine (TS), and lumbar spine (LS). Such structures are also unequally distributed within the individual vertebrae. Exact knowledge of the microstructure of these entities could impact our understanding and treatment of fractures caused by osteoporosis and possibly improve surgical approaches. Appropriate investigations could help clarify the pathomechanisms of different forms of osteoporotic vertebral fractures, as well as different changes in morphological findings like the trabecular bone score (TBS). In the present study, we applied punctures to the craniocaudal and ventrocaudal directions and obtained cylinders of cancellous bone from the central portions and marginal regions of cervical vertebrae 5 and 6, thoracic vertebrae 8 and 12, and lumbar vertebrae 1 and 3. We systematically analyzed these samples to determine the bone volume fraction, trabecular thickness, separation, connectivity density, degree of anisotropy, and structure model index. METHODS: Using an 8-gauge Jamshidi needle, we obtained samples from three quadrants (Q I: right margin; Q II: central; Q III: left margin) in the frontal and transverse plane and prepared these samples with a moist cloth in a 1.5 mL Eppendorf reaction vessel. The investigations were performed on a micro-CT device (SKYSCAN 1172, RJL Micro & Analytic Company, Karlsdorf-Neuthard, Germany). All collected data were analyzed using the statistical software package SPSS (version 24.0, IBM Corp., Armonk, NY, USA). Student's t test, the Wilcoxon-Mann-Whitney test, the Chi-squared test, and univariate analysis were used for between-group comparisons. The selection of the test depended on the number of investigated groups and the result of the Shapiro-Wilk test of normal distribution. In the case of statistically significant results, a post hoc LSD test was performed. RESULTS: In total, we obtained 360 bone samples from 20 body donors. The craniocaudal puncture yielded data of similar magnitudes for all investigated parameters in all three quadrants, with the highest values observed in the CS. Comparisons of the ventrodorsal and craniocaudal microstructure revealed a significantly lower trabecular density and a significantly higher degree of anisotropy in the craniocaudal direction. CONCLUSIONS: The results presented different distributions and behaviors of trabecular density, with lower density in the mid-vertebral region over the entire breadth of the vertebrae. Reduced trabecular density caused a higher degree of anisotropy and was, therefore, associated with a lower capacity to sustain biomechanical loads. Fractures in fish vertebrae were easily explained by this phenomenon. The different changes in these structures could be responsible, in part, for the changes in the TBS determined using dual-energy X-ray absorptiometry. These results confirm the clinical relevance of the TBS.

10.
Comput Biol Med ; 171: 108237, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38422966

ABSTRACT

Lumbar vertebral body cancellous bone location and segmentation is crucial in an automated lumbar spine processing pipeline. Accurate and reliable analysis of lumbar spine image is expected to advantage practical medical diagnosis and population-based analysis of bone strength. However, the design of automated algorithms for lumbar spine processing is demanding due to significant anatomical variations and scarcity of publicly available data. In recent years, convolutional neural network (CNN) and vision transformers (Vits) have been the de facto standard in medical image segmentation. Although adept at capturing global features, the inherent bias of locality and weight sharing of CNN constrains its capacity to model long-range dependency. In contrast, Vits excel at long-range dependency modeling, but they may not generalize well with limited datasets due to the lack of inductive biases inherent to CNN. In this paper, we propose a deep learning-based two-stage coarse-to-fine solution to address the problem of automatic location and segmentation of lumbar vertebral body cancellous bone. Specifically, in the first stage, a Swin-transformer based model is applied to predict the heatmap of lumbar vertebral body centroids. Considering the characteristic anatomical structure of lumbar spine, we propose a novel loss function called LumAnatomy loss, which enforces the order and bend of the predicted vertebral body centroids. To inherit the excellence of CNN and Vits while preventing their respective limitations, in the second stage, we propose an encoder-decoder network to segment the identified lumbar vertebral body cancellous bone, which consists of two parallel encoders, i.e., a Swin-transformer encoder and a CNN encoder. To enhance the combination of CNNs and Vits, we propose a novel multi-scale attention feature fusion module (MSA-FFM), which address issues that arise when fusing features given at different encoders. To tackle the issue of lack of data, we raise the first large-scale lumbar vertebral body cancellous bone segmentation dataset called LumVBCanSeg containing a total of 185 CT scans annotated at voxel level by 3 physicians. Extensive experimental results on the LumVBCanSeg dataset demonstrate the proposed algorithm outperform other state-of-the-art medical image segmentation methods. The data is publicly available at: https://zenodo.org/record/8181250. The implementation of the proposed method is available at: https://github.com/sia405yd/LumVertCancNet.


Subject(s)
Cancellous Bone , Vertebral Body , Lumbar Vertebrae/diagnostic imaging , Algorithms , Lumbosacral Region , Image Processing, Computer-Assisted
11.
J Mech Behav Biomed Mater ; 152: 106443, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38308976

ABSTRACT

The macro scale physical properties of cancellous bone materials are governed by the microstructural features, which is of great significance for the multi-scale research of cancellous bone and the inverse design of bone-mimicking materials. Therefore, it is essential to characterize the natural cancellous bone samples, and reconstruct the microstructures with the biomimetic osteointegration and mechanical properties. In this research, a novel approach for the characterization and reconstruction of cancellous bone was proposed, based on the medical image analysis and anisotropic three-dimensional Gaussian random field (GRF). The geometric similarity, i.e. the interface curvature distribution (ISD), was meticulously studied, which is important to the osteointegration ability. And the mechanical properties were validated by the stress-strain curves under the large compressive strain simulated by the smoothed particle hydrodynamic (SPH) method. In addition, the effects of the generation parameters of GRF-based biomimetic microstructures on the apparent properties were analyzed. The ISD results demonstrated that both GRF and micro-CT groups had the similar columnar morphological properties, while the latter had more hyperbolic features. And it was found that the GRF-based biomimetic microstructures and the natural bone samples based on micro-CT (MCT) had the similar failure mode. The concordance correlation coefficient between MCT and GRF pairs was 0.8685, with a Pearson ρ value of 0.8804, and significance level p<0.0001. The Bland-Altman LoA was 0.1647 MPa with 95 % (1.96SD) lower and upper bound value between -0.2892 and 0.6185 MPa. The two groups had almost the same elastic modulus with the mean absolute percentage error (MAPE) of 7.84 %. While the yield stress and total conversion energy of the GRF-based samples were lower than those of the natural bone samples, and the MAPE were 16.99 % and 16.27 %, respectively. Although it meant the lower structural efficiency, the huge design space of this approach and advanced 3D printing technology can provide great potential for the design of orthopedic implants.


Subject(s)
Bone and Bones , Cancellous Bone , Stress, Mechanical , Elastic Modulus , Prostheses and Implants
12.
Am J Biol Anthropol ; 183(3): e24695, 2024 Mar.
Article in English | MEDLINE | ID: mdl-36790736

ABSTRACT

OBJECTIVES: Recent studies have associated subarticular trabecular bone distribution in the extant hominid first metacarpal (Mc1) with observed thumb use, to infer fossil hominin thumb use. Here, we analyze the entire Mc1 to test for interspecific differences in: (1) the absolute volume of trabecular volume fraction, (2) the distribution of the deeper trabecular network, and (3) the distribution of trabeculae in the medullary cavity, especially beneath the Mc1 disto-radial flange. MATERIALS AND METHODS: Trabecular bone was imaged using micro-computed tomography in a sample of Homo sapiens (n = 11), Pan paniscus (n = 10), Pan troglodytes (n = 11), Gorilla gorilla (n = 10) and Pongo sp., (n = 7). Using Canonical Holistic Morphometric Analysis (cHMA), we tested for interspecific differences in the trabecular bone volume fraction (BV/TV) and its relative distribution (rBV/TV) throughout the Mc1, including within the head, medullary cavity, and base. RESULTS: P. paniscus had the highest, and H. sapiens the lowest, BV/TV relative to other species. rBV/TV distribution statistically distinguished the radial concentrations and lack of medullary trabecular bone in the H. sapiens Mc1 from all other hominids. H. sapiens and, to a lesser extent, G. gorilla also had a significantly higher trabecular volume beneath the disto-radial flange relative to other hominids. DISCUSSION: These results are consistent with differences in observed thumb use in these species and may also reflect systemic differences in bone volume fraction. The trabecular bone extension into the medullary cavity and concentrations beneath the disto-radial flange may represent crucial biomechanical signals that will aid in the inference of fossil hominin thumb use.


Subject(s)
Hominidae , Metacarpal Bones , Humans , Animals , Metacarpal Bones/diagnostic imaging , Thumb , X-Ray Microtomography , Pan troglodytes , Gorilla gorilla , Pongo , Pan paniscus
13.
Int Orthop ; 48(2): 487-493, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37796332

ABSTRACT

PURPOSE: Cancellous bone harvested from the distal radius has been used in various hand surgeries, but studies on its use in scaphoid waist nonunions are insufficient. We investigated the usefulness of cancellous bone graft from the distal radius and headless screw fixation in unstable scaphoid waist nonunion. METHODS: Thirty-one patients who underwent cancellous bone graft from the distal radius and headless screw fixation for unstable scaphoid waist nonunion with follow-up for at least 1 year were included. Bone union time, the number of patients with bone union at six and 12 weeks, total number of patients with bone union at last follow-up, and bone union on the computed tomography (CT) image at postoperative six weeks were evaluated. Further, pre- and postoperative radiological measurements, such as scaphoid length and height, lateral intra-scaphoid angle, and height-to-length ratio, and functional outcomes were compared. Additionally, inter-observer reliability of radiologic parameters was checked. RESULTS: Bone union was achieved in 29 patients. There were two nonunions (6.5%). Bone union time was 10.7 (range, 6-26) weeks. Eighteen (58%) and 25 patients (80.6%) were diagnosed with bone union on the plain radiographs at six and 12 weeks, respectively. Twenty-two patients (71%) were diagnosed with bone union on CT performed at six weeks. Radiological measurements and functional outcomes improved postoperatively. The scaphoid length showed good inter-observer agreement. CONCLUSIONS: In treating unstable scaphoid waist nonunion, cancellous bone graft from the distal radius and headless screw fixation achieved 93.5% union and improved radiological measurements as well as functional outcomes.


Subject(s)
Fractures, Ununited , Scaphoid Bone , Humans , Radius/diagnostic imaging , Radius/surgery , Cancellous Bone/transplantation , Reproducibility of Results , Retrospective Studies , Fractures, Ununited/diagnostic imaging , Fractures, Ununited/surgery , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Scaphoid Bone/diagnostic imaging , Scaphoid Bone/surgery , Bone Screws , Bone Transplantation/methods
14.
Eur J Radiol ; 170: 111209, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37992609

ABSTRACT

PURPOSE: To investigate the metal artifact suppression potential of combining tin prefiltration and virtual monoenergetic imaging (VMI) for osseous microarchitecture depiction in ultra-high-resolution (UHR) photon-counting CT (PCCT) of the lower extremity. METHOD: Derived from tin-filtered UHR scans at 140 kVp, polychromatic datasets (T3D) and VMI reconstructions at 70, 110, 150, and 190 keV were compared in 117 patients with lower extremity metal implants (53 female; 62.1 ± 18.0 years). Three implant groups were investigated (total arthroplasty [n = 48], osteosynthetic material [n = 43], and external fixation [n = 26]). Image quality was assessed with regions of interest placed in the most pronounced artifacts and adjacent soft tissue, measuring the respective attenuation. Additionally, artifact extent, bone-metal interface interpretability and overall image quality were independently evaluated by three radiologists. RESULTS: Artifact reduction was superior with increasing keV level of VMI. While T3D was superior to VMI70keV (p ≥ 0.117), artifacts were more severe in T3D than in VMI ≥ 110 keV (all p ≤ 0.036). Image noise was highest for VMI70keV (all p < 0.001) and lowest for VMI110keV with comparable results for VMI110keV - VMI190keV. Subjective image quality regarding artifacts was superior for VMI ≥ 110 keV (all p ≤ 0.042) and comparable for VMI110keV - VMI190keV. Bone-metal interface interpretability was superior for VMI110keV (all p ≤ 0.001), while T3D, VMI150keV and VMI190keV were comparable. Overall image quality was deemed best for VMI110keV and VMI150keV. Interreader reliability was good in all cases (ICC ≥ 0.833). CONCLUSIONS: Tin-filtered UHR-PCCT scans of the lower extremity combined with VMI reconstructions allow for efficient artifact reduction in the vicinity of bone-metal interfaces.


Subject(s)
Tin , Tomography, X-Ray Computed , Humans , Female , Reproducibility of Results , Tomography, X-Ray Computed/methods , Prostheses and Implants , Image Processing, Computer-Assisted/methods , Metals , Artifacts , Radiographic Image Interpretation, Computer-Assisted/methods , Signal-To-Noise Ratio , Retrospective Studies
15.
Am J Biol Anthropol ; 183(3): e24824, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37493308

ABSTRACT

OBJECTIVES: This research examines whether the distribution of trabecular bone in the proximal capitates of extant hominids, as well as several fossil hominin taxa, is associated with the oblique path of the midcarpal joint known as the dart-thrower's motion (DTM). MATERIALS AND METHODS: We analyzed proximal capitates from extant (Pongo n = 12; Gorilla n = 11; Pan n = 10; fossil and recent Homo sapiens n = 29) and extinct (Australopithecus sediba n = 2; Homo naledi n = 1; Homo floresiensis n = 2; Neandertals n = 3) hominids using a new canonical holistic morphometric analysis, which quantifies and visualizes the distribution of trabecular bone using relative bone volume as a fraction of total volume (rBV/TV). RESULTS: Homo sapiens and Neandertals had a continuous band of high rBV/TV that extended across the scaphoid, lunate, and hamate subarticular regions, but other fossil hominins and extant great apes did not. A. sediba expressed a distinct combination of human-like and Pan-like rBV/TV distribution. Both H. floresiensis and H. naledi had high rBV/TV on the ulnar-side of the capitate but low rBV/TV on the radial-side. CONCLUSION: The proximal capitates of H. sapiens and Neandertals share a distinctive distribution of trabecular bone that suggests that these two species of Homo regularly load(ed) their midcarpal joints along the full extent of the oblique path of the DTM. The observed pattern in A. sediba suggests that human-like stress at the capito-scaphoid articular surface was combined with Pan-like wrist postures, whereas the patterns in H. floresiensis and H. naledi suggest their midcarpal joints were loaded differently from that of H. sapiens and Neandertals.


Subject(s)
Carpal Joints , Hominidae , Neanderthals , Animals , Humans , Cancellous Bone/anatomy & histology , Fossils , Gorilla gorilla , Pongo
16.
Cureus ; 15(11): e48111, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38046749

ABSTRACT

Alveolar bone grafting (ABG) in cleft lip and palate patients allows for the facilitation of eruption of the canine and sometimes eruption of the lateral incisor. It provides bony support to the cleft raising the alar base of the nose and also facilitates the closure of an oro-nasal fistula. Many report at a time when late alveolar bone grafting is the only option to overcome the bony defect mainly due to their socioeconomic concern. Autologous bone graft for alveolar bone grafting harvested from the anterior iliac crest using the medial trap door technique has many advantages over other techniques of harvesting bone graft from the anterior iliac crest. In this case report we have discussed a case of bone graft harvesting from the anterior iliac crest using the medial trap door technique for late secondary alveolar bone grafting.

17.
Materials (Basel) ; 16(23)2023 Nov 29.
Article in English | MEDLINE | ID: mdl-38068170

ABSTRACT

Orthodontic treatment was accompanied by the remodeling of cancellous bone in alveolar bone (CBAB), which manifested as the increase or decrease in bone mineral density (BMD). BMD is closely related to the mechanical properties of the alveolar bone. Therefore, the aim of this study was to quantify the effect of BMD on its viscoelastic behavior and to assess orthodontic forces at different BMDs. A total of nine CBAB samples were cut from the cervical, middle, and apical regions of the right mandible between canine, premolars, and molars. After scanning with micro-computed tomography (micro-CT). The BMD of samples was measured and dynamic mechanical analysis (DMA) was performed. Based on the fourth-order generalized Maxwell model, a viscoelastic constitutive model characterizing the BMD variation was constructed. The BMD exhibited variations within different regions of the CBAB. The storage modulus is positively correlated with BMD, and the loss modulus is negatively correlated with BMD.

18.
J Clin Med ; 12(24)2023 Dec 06.
Article in English | MEDLINE | ID: mdl-38137607

ABSTRACT

Hemifacial Microsomia (HFM) is the second most common congenital craniofacial malformation syndrome, and the complexity of HFM makes its treatment challenging. The present study aimed to introduce a new approach of utilization of virtual surgical planning (VSP) and 3D-printed surgical adjuncts for maxillofacial reconstruction. Five HFM patients were included in this study. All participants were provided with a full VSP, including the design of osteotomy lines, the design and fabrication of 3D-printed cutting guides, fixation plates, and titanium mesh for implantation. With the assistance of 3D-printed cutting guides and fixation plates, the orbital deformities were corrected, and a 3D-printed titanium mesh combined with iliac cancellous bone graft was applied to reconstruct the zygomatic arch. The surgical accuracy, effectiveness, and bone absorption rate were evaluated. All patients completed the entirely digital treatment process without experiencing severe complications. The surgical adjuncts were effective in aligning the movement of the bone segments with the surgical plan, resulting in mean 3D deviations (1.0681 ± 0.15 mm) and maximum 3D deviations (3.1127 ± 0.44 mm). The image fusion results showed that the patients' postoperative position of the maxilla, zygoma, and orbital rim was consistent with the virtual surgical plan, with only a slight increase in the area of bone grafting. The postoperative measurements showed significant improvement in the asymmetry indices of Er (AI of Er: from 17.91 ± 3.732 to 5.427 ± 1.389 mm, p = 0.0001) and FZ (AI of FZ: from 7.581 ± 1.435 to 4.070 ± 1.028 mm, p = 0.0009) points. In addition, the observed bone resorption rate at the 6-month follow-up across the five patients was 45.24% ± 3.13%. In conclusion, the application of VSP and 3D-printed surgical adjuncts demonstrates significant value in enhancing the precision and effectiveness of surgical treatments for HFM. A 3D-printed titanium mesh combined with iliac cancellous bone graft can be considered an ideal alternative for the reconstruction of the zygomatic arch.

19.
Front Bioeng Biotechnol ; 11: 1264409, 2023.
Article in English | MEDLINE | ID: mdl-38026873

ABSTRACT

In musculoskeletal surgery, the treatment of large bone defects is challenging and can require the use of bone graft substitutes to restore mechanical stability and promote host-mediated regeneration. The use of bone allografts is well-established in many bone regenerative procedures, but is associated with low rates of ingrowth due to pre-therapeutic graft processing. Cold physical plasma (CPP), a partially ionized gas that simultaneously generates reactive oxygen (O2) and nitrogen (N2) species, is suggested to be advantageous in biomedical implant processing. CPP is a promising tool in allograft processing for improving surface characteristics of bone allografts towards enhanced cellularization and osteoconduction. However, a preclinical assessment regarding the feasibility of pre-therapeutic processing of allogeneic bone grafts with CPP has not yet been performed. Thus, this pilot study aimed to analyze the bone morphology of CPP processed allografts using synchrotron radiation-based microcomputed tomography (SR-µCT) and to analyze the effects of CPP processing on human bone cell viability and function. The analyzes, including co-registration of pre- and post-treatment SR-µCT scans, revealed that the main bone morphological properties (total volume, mineralized volume, surface area, and porosity) remained unaffected by CPP treatment if compared to allografts not treated with CPP. Varying effects on cellular metabolic activity and alkaline phosphatase activity were found in response to different gas mixtures and treatment durations employed for CPP application. It was found that 3 min CPP treatment using a He + 0.1% N2 gas mixture led to the most favourable outcome regarding a significant increase in bone cell viability and alkaline phosphatase activity. This study highlights the promising potential of pre-therapeuthic bone allograft processing by CPP prior to intraoperative application and emphasizes the need for gas source and treatment time optimization for specific applications.

20.
BMC Oral Health ; 23(1): 681, 2023 09 20.
Article in English | MEDLINE | ID: mdl-37730602

ABSTRACT

BACKGROUND: The reconstruction of large mandibular defects is a challenge, and free vascularized bone flaps are most commonly used. However, the precision and symmetry of this repair are deficient, and patients have a risk of vascular embolism, flap necrosis, and donor site complications. Therefore, to explore an ideal alternative in mandibular reconstruction with high surgical accuracy and low complications is indispensable. METHODS: Seven patients with recurrent or large-scope ameloblastoma were enrolled in this study. All patients were provided with a fully digital treatment plan, including the design of osteotomy lines, surgical guides, and three-dimensional printed titanium mesh for implantation. With the assistance of surgical guide, ameloblastomas were resected, and custom 3D printed titanium mesh combined with posterior iliac bone harvest was used in mandibular reconstruction. A comparison was made between the discrepant surgical outcomes and the intended surgical plan, as well as the average three-dimensional deviation of the mandible before and after the surgery. At the same time, the resorption rate of the implanted bone was evaluated. RESULTS: All patients completed the fully digital treatment process successfully without severe complications. Image fusion showed that the postoperative contour of the mandible was basically consistent with surgical planning, except for a slight increase in the inferior border of the affected side. The mean three-dimensional deviation of the mandible between the preoperative and postoperative periods was 0.78 ± 0.41 mm. The mean error between the intraoperative bone volume and the digital planning bone volume was 2.44%±2.10%. Furthermore, the bone resorption rates of the harvested graft 6 months later were 32.15%±6.95%. CONCLUSIONS: The use of digital surgical planning and 3D-printed templates can assist surgeons in performing surgery precisely, and the 3D-printed titanium mesh implant can improve the patient's facial symmetry. 3D printed titanium mesh combined with posterior iliac cancellous bone graft can be regarded as an ideal alternative in extensive mandibular reconstruction.


Subject(s)
Ameloblastoma , Dental Implants , Humans , Ameloblastoma/surgery , Titanium , Cancellous Bone , Surgical Mesh , Mandible/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...