Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
World J Pediatr Congenit Heart Surg ; 9(6): 710-713, 2018 11.
Article in English | MEDLINE | ID: mdl-28055329

ABSTRACT

We report the case of an 11-year-old girl with heterotaxy syndrome, dextrocardia, and azygos continuation of an interrupted inferior vena cava who had developed pulmonary arteriovenous fistulas after a Kawashima procedure consisting of bilateral superior cavopulmonary anastomoses. She presented with profound cyanosis, fatigue, and failure to thrive. An operative procedure to direct hepatic vein effluent to the pulmonary circulation was performed with placement of an extracardiac conduit between the hepatic veins and the left pulmonary artery. Persistence of cyanosis led to investigation, which led to the discovery of an unintentionally excluded right hepatic vein. A percutaneous transhepatic catheter intervention was performed in which a vascular plug was implanted to occlude the "missed" right hepatic vein, redirecting the flow through intrahepatic venovenous channels to the conduit. Clinical condition and arterial oxygen saturation were substantially improved one year after the two-step hepatic vein inclusion procedure.


Subject(s)
Heart Bypass, Right/methods , Heart Defects, Congenital/surgery , Hepatic Veins/surgery , Vena Cava, Inferior/surgery , Child , Female , Heart Defects, Congenital/physiopathology , Humans , Pulmonary Circulation
2.
Interact Cardiovasc Thorac Surg ; 17(6): 1048-50, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23996734

ABSTRACT

A 60-year old male patient with multiple risk factors and two previous interventions over the mitral valve was admitted to the emergency unit with symptoms of cardiac failure. Initial examination revealed a competent mitral bioprosthesis with severe perivalvular mitral insufficiency. Based on previous experiences with transapical procedures, a transapical transcatheter closure of the perivalvular leak was performed. The apex was punctured with a 7 French introducer sheath, and a hydrophilic guidewire was advanced with the aid of a right Judkins catheter and positioned across the defect in the left atrium. Fluoroscopic and tridimensional transoesophageal echocardiography was used to guide the manoeuvre. Next, a long introducer sheath was advanced through the guidewire and positioned inside the left atrium. Two Amplatzer Vascular Plug II (St Jude Medical) were deployed, resulting in a significant reduction in the perivalvular leak. The procedure was considered to be successful. The patient regained consciousness, and the orotracheal tube was removed in the operating theatre. No neurological deficits were detected, and the patient was transferred to the intensive care unit. The patient recovered well and was transferred to the ward after 1 day. Discharge was accomplished after 4 days.


Subject(s)
Bioprosthesis , Cardiac Catheterization , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Mitral Valve Insufficiency/therapy , Mitral Valve/surgery , Prosthesis Failure , Cardiac Catheterization/instrumentation , Echocardiography, Doppler, Color , Echocardiography, Three-Dimensional , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Middle Aged , Mitral Valve Insufficiency/diagnosis , Mitral Valve Insufficiency/etiology , Prosthesis Design , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL