Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 125
Filter
2.
Med J Aust ; 220(10): 510-516, 2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38711337

ABSTRACT

OBJECTIVES: To quantify the rate of cardiac implantable electronic device (CIED)-related infections and to identify risk factors for such infections. DESIGN: Retrospective cohort study; analysis of linked hospital admissions and mortality data. SETTING, PARTICIPANTS: All adults who underwent CIED procedures in New South Wales between 1 January 2016 and 30 June 2021 (public hospitals) or 30 June 2020 (private hospitals). MAIN OUTCOME MEASURES: Proportions of patients hospitalised with CIED-related infections (identified by hospital record diagnosis codes); risk of CIED-related infection by patient, device, and procedural factors. RESULTS: Of 37 675 CIED procedures (23 194 men, 63.5%), 500 were followed by CIED-related infections (median follow-up, 24.9 months; interquartile range, 11.2-40.8 months), including 397 people (1.1%) within twelve months of their procedures, and 186 of 10 540 people (2.5%) at high risk of such infections (replacement or upgrade procedures; new cardiac resynchronisation therapy with defibrillator, CRT-D). The overall infection rate was 0.50 (95% confidence interval [CI], 0.45-0.54) per 1000 person-months; it was highest during the first month after the procedure (5.60 [95% CI, 4.89-6.42] per 1000 person-months). The risk of CIED-related infection was greater for people under 65 years of age than for those aged 65-74 years (adjusted hazard ratio [aHR], 1.71; 95% CI, 1.32-2.23), for people with CRT-D devices than for those with permanent pacemakers (aHR, 1.46; 95% CI, 1.02-2.08), for people who had previously undergone CIED procedures (two or more v none: aHR, 1.51; 95% CI, 1.02-2.25) or had CIED-related infections (aHR, 11.4; 95% CI, 8.34-15.7), or had undergone concomitant cardiac surgery (aHR, 1.62; 95% CI, 1.10-2.39), and for people with atrial fibrillation (aHR, 1.33; 95% CI, 1.11-1.60), chronic kidney disease (aHR, 1.54; 95% CI, 1.27-1.87), chronic obstructive pulmonary disease (aHR, 1.37; 95% CI, 1.10-1.69), or cardiomyopathy (aHR 1.60; 95% CI, 1.25-2.05). CONCLUSIONS: Knowledge of risk factors for CIED-related infections can help clinicians discuss them with their patients, identify people at particular risk, and inform decisions about device type, upgrades and replacements, and prophylactic interventions.


Subject(s)
Defibrillators, Implantable , Prosthesis-Related Infections , Humans , Male , Retrospective Studies , Female , Aged , New South Wales/epidemiology , Defibrillators, Implantable/adverse effects , Defibrillators, Implantable/statistics & numerical data , Prosthesis-Related Infections/epidemiology , Prosthesis-Related Infections/etiology , Middle Aged , Risk Factors , Aged, 80 and over , Pacemaker, Artificial/adverse effects , Pacemaker, Artificial/statistics & numerical data , Adult , Hospitalization/statistics & numerical data
4.
Circulation ; 149(5): 379-390, 2024 01 30.
Article in English | MEDLINE | ID: mdl-37950738

ABSTRACT

BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Tachycardia, Ventricular , Humans , Cardiac Resynchronization Therapy/adverse effects , Stroke Volume , Ventricular Function, Left , Treatment Outcome , Tachycardia, Ventricular/epidemiology , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/therapy , Ventricular Fibrillation/epidemiology , Ventricular Fibrillation/etiology , Ventricular Fibrillation/therapy , Heart Failure/epidemiology , Heart Failure/therapy , Electrocardiography
5.
Pediatr Rheumatol Online J ; 21(1): 135, 2023 Nov 09.
Article in English | MEDLINE | ID: mdl-37946215

ABSTRACT

BACKGROUND: It has been reported that the complete heart block (CHB) in neonatal lupus (NL) cannot be reversed. This study reported a case of NL-CHB that was reversed by transcutaneous pacing and repeated plasmapheresis. CASE PRESENTATION: A 35+ 6-week male preterm baby was transferred to the neonatal intensive care unit of the Army Medical Center in May 2020 for slight cyanosis around the lips and nose. Two days after birth, a sudden decrease in heart rate was observed during electrocardiogram (EGG) monitoring. Physical examination revealed a bluish-purple discoloration around the lips and an irregular heartbeat. EGG showed the presence of isolated P (142 bpm) and QRS (78 bpm) waves, ventricular escape beats, and a diagnosis of NL-CHB. To reverse the condition, transcutaneous pacing and five sessions of plasmapheresis were performed. At a 1.5-year follow-up, the baby exhibited well-developed cardiac structure and normal neurodevelopment. CONCLUSIONS: Transcutaneous pacing and repeated plasmapheresis might be possible to reverse CHB in NL.


Subject(s)
Electrocardiography , Heart Block , Infant, Newborn , Humans , Male , Heart Block/etiology , Heart Block/therapy , Plasmapheresis/adverse effects
6.
HU rev ; 4920230000.
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1562873

ABSTRACT

Introdução: Pacientes com insuficiência cardíaca e doenças do sistema de condução necessitam de dispositivos para monitoramento dos batimentos cardíacos, como marcapassos permanentes, dispositivos de ressincronização cardíaca ou cardiodesfibriladores implantáveis. A estimulação ventricular direita (EVD) é tradicionalmente o tratamento de escolha. No entanto, estudos demonstraram evidências de dissincronia ventricular, redução da função cardíaca, recorrência de fibrilação atrial e aumento da mortalidade associadas a esta abordagem. O conhecimento dos efeitos adversos das técnicas convencionais justifica a realização de pesquisas para determinar se a estimulação hissiana (EH) é uma técnica que produz maior ativação fisiológica e ventricular mais sincronizada. Objetivo: Avaliar a eficácia da estimulação hissiana comparada à EVD em relação aos parâmetros eletrocardiográficos, ecocardiográficos e clínicos.Material e Métodos: Os critérios de elegibilidade seguiram a estratégia PICOS: P ­ pacientes com indicação de dispositivos cardíacos eletrônicos implantáveis; I ­ estimulação hissiana; C ­ estimulação ventricular direita; O ­ duração do complexo QRS, fração de ejeção, diâmetro ventricular ou classe funcional da New York Heart Association (NYHA); S ­ ensaios clínicos controlados randomizados (ECR) e não randomizados. As buscas foram realizadas nas bases Medline via PubMed, Embase, LILACS e Cochrane Library, realizadas em março de 2023 por três revisores independentes. Resultados: Foram incluídos sete ensaios clínicos comparando as técnicas EH versus EVD quanto aos desfechos investigados. Para a duração do complexo QRS, três estudos encontraram resultado significativamente melhor no grupo intervenção. Para fração de ejeção e classe funcional da NYHA, dois estudos apresentaram resultados significativamente melhores no grupo EH. Quanto ao risco de viés, apenas dois apresentaram risco baixo e médio, quatro apresentaram risco alto em um, dois ou três dos itens avaliados. Conclusões: A técnica EH demonstrou superioridade à técnica convencional, entretanto são necessários ECR de maior qualidade metodológica e meta-análises para verificar a eficácia clínica da técnica, envolvendo maior número de pacientes e tempo de seguimento.


Introduction: Patients with heart failure and cardiac conditions require devices for monitoring the heartbeat, such as permanent pacemakers, cardiac resynchronization devices, or implantable cardioverter defibrillators. Right ventricular stimulation (RVP) has traditionally been the treatment of choice. However, studies have shown evidence of ventricular dyssynchrony, reduced cardiac function, recurrence of atrial fibrillation, and increased mortality associated with this approach. Recognizing the adverse effects of conventional techniques justifies conducting research to determine whether Hissian or His bundle pacing (HPB) stimulation can provide more physiologically synchronized ventricular activation. Objective: The aim is to assess the efficacy of Hissian stimulation compared to right ventricular pacing (RVP) in relation to electrocardiographic, echocardiographic and clinical parameters. Material and Methods: The eligibility criteria will follow the PICOS strategy: P ­ Patients with indication for implantable electronic cardiac devices; I ­ Hissan Stimulation; C ­ Right Ventricular Stimulation; O ­ QRS complex duration, ejection fraction, ventricular diameter and New York Heart Association (NYHA) functional class; S ­ Controlled Trials. Searches were conducted on the Medline via PubMed, Embase, Latin America and Caribbean Health Science Literature Database (LILACS) and Cochrane Library platforms. The searches were performed in March 2023 by three independent reviewers. Results: Seven clinical trials were included, comparing HPB versus RVP techniques regarding the investigated outcomes. For the QRS complex duration, three studies found a significantly better result in the intervention group. For ejection fraction and NYHA functional class, two studies had significantly better results in the HPB group too. Concerning the risk of bias, out of the seven studies included, only two presented low and medium risk, four presented high risk in one, two or three of the items evaluated. Conclusions: The HPB technique has demonstrated superiority to the conventional technique, however, RCT of higher methodological quality and meta-analysis are needed to verify the clinical effectiveness of the technique, involving more patients and longer follow-up time.

8.
Arq. bras. cardiol ; 120(2): e20210941, 2023. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1420185

ABSTRACT

Resumo Há uma enorme disparidade entre os países de alta renda e outros em termos de acesso a dispositivos médicos cardíacos, como marca-passos e desfibriladores implantáveis. Os custos são uma das principais barreiras ao uso de dispositivos cardíacos nesses países. Existem iniciativas internacionais que visam reduzir essa disparidade, e o reuso de marca-passos tem sido discutido como uma possível alternativa. O conceito de reutilização de marca-passos não é novo; entretanto, estudos recentes têm se mostrado seguros, éticos e eficazes para aqueles que precisam de dispositivos eletrônicos cardíacos implantáveis e não tem como adquiri-los. Parte dos países de língua portuguesa, especialmente na África, precisam de uma resposta imediata que beneficie seus inúmeros pacientes que sofrem de arritmias tratáveis.


Abstract There is a gap between high-income countries and others in terms of access to medical cardiac devices, such as pacemakers and implantable cardioverter defibrillators. Costs are one of the main barriers to the use of cardiac devices in these countries. There are international initiatives that aim to reduce the gap. The reuse of pacemakers has been discussed as a possible alternative to this problem. The concept of reusing pacemakers is not new; however, recent studies have proven to be safe, ethical, and effective for those who need cardiac implantable electronic devices and cannot afford them. Part of the Portuguese-speaking countries, especially in Africa, need an immediate response that benefits their countless patients who suffer from treatable arrhythmias.

9.
J Cardiovasc Imaging ; 30(1): 62-75, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35086172

ABSTRACT

BACKGROUND: Due to its location very close to the bundle of His, mitral annulus calcification (MAC) might be associated with the development of atrioventricular (AV) conduction disturbances. This study assessed the association between MAC and AV conduction disturbances identified by cardiac implantable electronic device (CIED) use and electrocardiographic parameters. The association between MAC and traditional cardiovascular risk factors was also assessed. METHODS: This cross-sectional study analyzed 14,771 participants, predominantly men aged 60-75 years, from the population-based Danish Cardiovascular Screening trial. Traditional cardiovascular risk factors were obtained. Using cardiac non-contrast computed tomography imaging, MAC scores were measured using the Agatston method and divided into absent versus present and score categories. CIED implantation data were obtained from the Danish Pacemaker and Implantable Cardioverter Defibrillator Register. A 12-lead electrocardiogram was available for 2,107 participants. Associations between MAC scores and AV conduction disturbances were assessed using multivariate regression analyses. RESULTS: MAC was present in 22.4% of the study subjects. Participants with pacemakers for an AV conduction disturbance had significantly higher MAC scores (odds ratio [OR], 1.11; 95% confidence interval [CI], 1.01-1.23) than participants without a CIED, whereas participants with a CIED for other reasons did not. Prolonged QRS-interval was significantly associated with the presence of MAC (OR, 1.45; 95% CI, 1.04-2.04), whereas prolonged PQ-interval was not. Female sex and most traditional cardiovascular risk factors were significantly associated with high MAC scores. CONCLUSIONS: MAC was associated with AV conduction disturbances, which could improve our understanding of the development of AV conduction disturbances.

10.
Arch Peru Cardiol Cir Cardiovasc ; 3(4): 210-214, 2022.
Article in Spanish | MEDLINE | ID: mdl-37284564

ABSTRACT

Left bundle branch stimulation is a second-line strategy in patients where His bundle stimulation is not optimal. Currently, no cases of left bundle branch stimulation have been reported in patients with diffuse electrical cardiac disease or in the pediatric population.

11.
Medisur ; 19(6)dic. 2021.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1405850

ABSTRACT

RESUMEN En Cuba, el primer implante de marcapasos se realizó el 6 de julio de 1964, mientras que en Cienfuegos se inicia esta actividad en 1979, por un grupo de profesionales liderados por el Dr. Francisco Riverón Mena, quien se mantuvo durante más de diez años al frente de la estimulación cardíaca, en el Hospital Dr. Gustavo Aldereguía Lima. El presente trabajo se propone describir el método para el implante de marcapasos permanente aplicado en dicha institución, introducido por el Dr. Riverón, como alternativa al modo convencional. Esta técnica requiere muy poca utilización de radiaciones ionizantes; resulta eficaz y más segura, tanto para el paciente como para el personal de salud, pues se emplea radioscopia solo en el último momento del procedimiento, lo cual la diferencia del método convencional. Aunque en la actualidad no se practica, durante la etapa que se aplicó en el hospital, brindó seguridad a pacientes y personal de salud, por lo que debería retomarse su uso.


ABSTRACT In Cuba, the first pacemaker implant was carried out on July 6, 1964, while in Cienfuegos this activity began in 1979, by a group of professionals led by Dr. Francisco Riverón Mena, who stayed for more than ten years in charge of cardiac stimulation, at the Dr. Gustavo Aldereguía Lima Hospital. The present work aims to describe the method for permanent pacemaker implantation applied in said institution, introduced by Dr. Riverón, as an alternative to the conventional mode. This technique requires very little use of ionizing radiation; It is effective and safer, both for the patient and for the health personnel, since fluoroscopy is used only at the last moment of the procedure, which differentiates it from the conventional method. Although it is not currently practiced, during the stage that it was applied in the hospital, it provided security to patients and health personnel, so its use should be resumed.

13.
Tex Heart Inst J ; 48(2)2021 06 04.
Article in English | MEDLINE | ID: mdl-34086954

ABSTRACT

Congenital complete heart block is a potentially fatal complication that can occur in neonates whose mothers have autoimmune disorders; it has rarely been reported in the presence of Sjögren syndrome. Pacemaker implantation is recommended to treat rhythm abnormalities in these neonates. We report the case of a late-preterm infant with Sjögren-syndrome-antibody-induced complete heart block who underwent temporary bipolar epicardial pacing as a bridge to permanent pacemaker implantation. Soon after the pacemaker was implanted, takotsubo cardiomyopathy developed. To our knowledge, this is the first report of reversible cardiomyopathy after pacemaker implantation in an infant.


Subject(s)
Atrioventricular Block , Cardiomyopathies , Pacemaker, Artificial , Atrioventricular Block/diagnosis , Atrioventricular Block/etiology , Atrioventricular Block/therapy , Cardiac Pacing, Artificial/adverse effects , Heart Block/congenital , Humans , Infant , Infant, Newborn , Infant, Premature , Pacemaker, Artificial/adverse effects
14.
Arch Peru Cardiol Cir Cardiovasc ; 2(2): 112-120, 2021.
Article in Spanish | MEDLINE | ID: mdl-38274564

ABSTRACT

The presence of mitral regurgitation (MR) in patients with right ventricular apical pacing can be the result of multiple phenomena. On the one hand, this stimulation causes an asynchronous activation of the left ventricle (LV) and the papillary muscles, leading to a deterioration of the LV ejection fraction and causing an inadequate closure of the valve apparatus. However, there is a wide heterogeneity of ischemic and non-ischemic myocardial conditions that can coexist with mechanical alteration of the LV and the mitral valve leading to or worsening MR in these patients, which can make the etiological determination of valvular regurgitation difficult. Transthoracic echocardiography study allows comprehensive evaluation of mitral valve regurgitation and ventricular function parameters and mechanical asynchrony as a result of artificial pacing. The comprehensive study of these phenomena is relevant in clinical decision-making to define those patients who benefit from cardiac resynchronization therapy to alleviate symptomatic MR.

15.
Arq. bras. cardiol ; 115(6): 1114-1124, dez. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1152928

ABSTRACT

Resumo Fundamento Remoção de cabos-eletrodos de dispositivos cardíacos eletrônicos implantáveis (DCEI) é procedimento pouco frequente e sua realização exige longo treinamento profissional e infraestrutura adequada. Objetivos Avaliar a efetividade e a segurança da remoção de cabos-eletrodos de DCEI e determinar fatores de risco para complicações cirúrgicas e mortalidade em 30 dias. Métodos Estudo prospectivo com dados derivados da prática clínica. De janeiro/2014 a abril/2020, foram incluídos, consecutivamente, 365 pacientes submetidos à remoção de cabos-eletrodos, independentemente da indicação e técnica cirúrgica utilizada. Os desfechos primários foram: taxa de sucesso do procedimento, taxa combinada de complicações maiores e morte intraoperatória. Os desfechos secundários foram: fatores de risco para complicações intraoperatórias maiores e morte em 30 dias. Empregou-se análise univariada e multivariada, com nível de significância de 5%. Resultados A taxa de sucesso do procedimento foi de 96,7%, sendo 90,1% de sucesso completo e 6,6% de sucesso clínico. Complicações maiores intraoperatórias ocorreram em 15 (4,1%) pacientes. Fatores preditores de complicações maiores foram: tempo de implante dos cabos-eletrodos ≥ 7 anos (OR= 3,78, p= 0,046) e mudança de estratégia cirúrgica (OR= 5,30, p= 0,023). Classe funcional III-IV (OR= 6,98, p<0,001), insuficiência renal (OR= 5,75, p=0,001), infecção no DCEI (OR= 13,30, p<0,001), número de procedimentos realizados (OR= 77,32, p<0,001) e complicações maiores intraoperatórias (OR= 38,84, p<0,001) foram fatores preditores para mortalidade em 30 dias. Conclusões Os resultados desse estudo, que é o maior registro prospectivo de remoção de cabos-eletrodos da América Latina, confirmam a segurança e a efetividade desse procedimento no cenário da prática clínica real. (Arq Bras Cardiol. 2020; 115(6):1114-1124)


Abstract Background Transvenous lead extraction (TLE) of cardiac implantable electronic devices (CIED) is an uncommon procedure and requires specialized personnel and adequate facilities. Objectives To evaluate the effectiveness and safety of the removal of CIED leads and to determine risk factors for surgical complications and mortality in 30 days. Methods Prospective study with data derived from clinical practice. From January 2014 to April 2020, we included 365 consecutive patients who underwent TLE, regardless of the indication and surgical technique used. The primary outcomes were: success rate of the procedure, combined rate of major complications and intraoperative death. Secondary outcomes were: risk factors for major intraoperative complications and death within 30 days. Univariate and multivariate analysis were used, with a significance level of 5%. Results Procedure success rate was 96.7%, with 90.1% of complete success and 6.6% of clinical success. Major intraoperative complications occurred in 15 (4.1%) patients. Predictors of major complications were: lead dwelling time ≥ 7 years (OR = 3.78, p = 0.046) and change in surgical strategy (OR = 5.30, p = 0.023). Functional class III-IV (OR = 6.98, p <0.001), renal failure (OR = 5.75, p = 0.001), CIED infection (OR = 13.30, p <0.001), number of procedures performed (OR = 77.32, p <0.001) and major intraoperative complications (OR = 38.84, p <0.001) were predictors of 30-day mortality. Conclusions The results of this study, which is the largest prospective registry of consecutive TLE procedures in Latin America, confirm the safety and effectiveness of this procedure in the context of real clinical practice. (Arq Bras Cardiol. 2020; 115(6):1114-1124)


Subject(s)
Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Prospective Studies , Retrospective Studies , Treatment Outcome , Device Removal
18.
Zhonghua Er Ke Za Zhi ; 58(2): 107-112, 2020 Feb 02.
Article in Chinese | MEDLINE | ID: mdl-32102146

ABSTRACT

Objective: To explore the safety and effectiveness of left bundle branch area pacing (LBBAP) in children. Methods: Clinical data, pacing electrocardiogram and parameters of 6 patients (5 females and 1 male) who underwent permanent pacemaker implantation and LBBAP from January to June 2019 in the Department of Pediatric Cardiology of Anzhen Hospital were retrospectively analyzed. Results: The weight of the 6 patients aged between 9 and 14 years ranged from 26 to 48 kg. Five patients were diagnosed with third degree atrioventricular block, and 1 patient was diagnosed with cardiac dysfunction after right ventricular apical pacing. Cardiac function decreased in one patient and remained normal in the other five patients. Left ventricular end diastolic diameter (LVEDD) Z score was 1.85±0.65. V(1) lead showed changes like right bundle branch block in pacing electrocardiogram. No significant difference was found regarding QRS wave duration ((95±13) ms vs. (111±20) ms, t=-1.610, P>0.05) between preoperation and postoperation. Pacing threshold was (0.85±0.26) V. The sensing threshold was (15.0±4.3) mV and the impedance was (717±72) Ω. P potential was recorded in 3 cases. The earliest left ventricular local activation time was (56±5) ms and remained stable at different output voltages. Postoperative echocardiography revealed that the electrodes were located near the endocardium of the left ventricular septum. No complications such as myocardial perforation and electrode dislocation occurred during follow-up. The pacing threshold, sensing threshold and impedance were (0.60±0.09)V, (16.1±3.9)mV, (662±78)Ω respectively at 3 months after operation. The patient with low left ventricular ejection fraction (LVEF) recovered to normal on the 3 rd day after LBBAP (45% vs. 57%). The LVEDD Z score decreased to (1.1±0.3) at 3 months after operation and was significantly lower than that before operation (t=2.38, P<0.05). Conclusions: LBBAP in children can achieve narrow QRS pacing andphysiological pacing with stablepacing parameters. It can improve left ventricular enlargement caused by long-term bradycardia, and cardiac dysfunction and cardiac enlargement caused by long-term right ventricular apical pacing quickly and effectively.LBBAP is safe and feasible for older children in the near future. However, the long term potential risks of LBBAP need further observation and study.


Subject(s)
Atrioventricular Block/surgery , Bundle-Branch Block/physiopathology , Cardiac Pacing, Artificial , Pacemaker, Artificial , Ventricular Function, Left/physiology , Adult , Bundle-Branch Block/diagnostic imaging , Child , Electrocardiography , Female , Humans , Male , Middle Aged , Retrospective Studies , Stroke Volume , Treatment Outcome , Ventricular Septum
19.
Arq. bras. cardiol ; 114(2): 245-253, Feb. 2020. tab, graf
Article in English | LILACS | ID: biblio-1088859

ABSTRACT

Abstract Background: Cardioinhibitory carotid sinus hypersensitivity (CICSH) is defined as ventricular asystole ≥ 3 seconds in response to 5-10 seconds of carotid sinus massage (CSM). There is a common concern that a prolonged asystole episode could lead to death directly from bradycardia or as a consequence of serious trauma, brain injury or pause-dependent ventricular arrhythmias. Objective: To describe total mortality, cardiovascular mortality and trauma-related mortality of a cohort of CICSH patients, and to compare those mortalities with those found in a non-CICSH patient cohort. Methods: In 2006, 502 patients ≥ 50 years of age were submitted to CSM. Fifty-two patients (10,4%) were identified with CICSH. Survival of this cohort was compared with that of another cohort of 408 non-CICSH patients using Kaplan-Meier curves. Cox regression was used to examine the relation between CICSH and mortality. The level of statistical significance was set at 0.05. Results: After a maximum follow-up of 11.6 years, 29 of the 52 CICSH patients (55.8%) were dead. Cardiovascular mortality, trauma-related mortality and the total mortality rate of this population were not statistically different from that found in 408 patients without CICSH. (Total mortality of CICSH patients 55.8% vs. 49,3% of non-CICSH patients; p: 0.38). Conclusion: At the end of follow-up, the 52 CICSH patient cohort had total mortality, cardiovascular mortality and trauma-related mortality similar to that found in 408 patients without CICSH.


Resumo Fundamento: A resposta cardioinibitória (RCI) à massagem do seio carotídeo (MSC) caracteriza-se por assistolia ≥ 3 segundos provocada por 5 a 10 segundos de MSC. Existe uma preocupação de que pacientes com RCI e episódios prolongados de assistolia possam falecer em consequência direta de bradiarritmia, ou em decorrência de lesão cerebral, trauma grave ou arritmia ventricular pausa dependente. Objetivos: Determinar a mortalidade total, a mortalidade cardiovascular e a mortalidade relacionada ao trauma de uma coorte de pacientes com RCI à MSC e comparar essas mortalidades com as de uma coorte de pacientes sem RCI à MSC. Métodos: Em 2006, 502 pacientes com idade igual ou superior a 50 anos foram submetidos à MSC. Destes, 52 pacientes (10,4%) foram identificados com RCI. A sobrevida desta coorte foi comparada àquela observada em uma coorte de 408 pacientes sem RCI por meio de curvas de Kaplan-Meier. A regressão de Cox foi utilizada para avaliação da relação entre a RCI à MSC e a mortalidade. Variáveis com p < 0,05 foram consideradas estatisticamente significativas. Resultados: Após seguimento máximo de 11,6 anos, 29 dos 52 portadores de RCI (55,8%) faleceram. A mortalidade total, a mortalidade cardiovascular e a mortalidade relacionada ao trauma desta coorte de pacientes não foram significativamente diferentes daquelas encontradas nos 408 pacientes sem RCI (mortalidade total com RCI: 55,8% versus 49,3% sem RCI; p: 0,38). Conclusões: No fim do seguimento, a mortalidade dos 52 portadores de RCI foi semelhante à observada em uma coorte de pacientes sem RCI. A mortalidade cardiovascular e a relacionada ao trauma também foi semelhante nas duas coortes.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Carotid Artery Diseases/physiopathology , Carotid Artery Diseases/mortality , Carotid Sinus/physiopathology , Heart Arrest/physiopathology , Heart Arrest/mortality , Syncope/physiopathology , Syncope/mortality , Proportional Hazards Models , Risk Factors , Follow-Up Studies , Longitudinal Studies , Statistics, Nonparametric , Electrocardiography , Kaplan-Meier Estimate , Heart Injuries/physiopathology , Heart Injuries/mortality
SELECTION OF CITATIONS
SEARCH DETAIL
...