Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Rev. bras. ortop ; 58(6): 869-875, 2023. tab, graf
Article in English | LILACS | ID: biblio-1535617

ABSTRACT

Abstract Objective This study assesses the relationship between the glenoid bone loss size and range of motion, functional outcomes, and complications in high-performance athletes undergoing bone block surgery for anterior shoulder instability. Methods This retrospective study evaluated postoperative outcomes in athletes submitted to bone block surgery for anterior shoulder instability. In 5 years, 41 shoulders underwent the procedure; 20 had bone losses up to 15%, and 21 shoulders presented bone losses ranging from 15% and 25%. Results There was no statistically significant difference regarding postoperative complications, new dislocations, and the rate of return to sports. In addition, the quantitative criteria evaluated, i.e., ranges of motion and functional scores, showed no statistically significant difference between groups. Conclusion The size of the bone loss per se does not seem to affect functional outcomes and complications from these procedures, which are safe techniques for small and large bone losses.


Resumo Objetivo Avaliar a relação do tamanho do defeito ósseo da glenoide no arco de movimento, nos resultados funcionais e nas complicações em pacientes atletas de alta performance submetidos a cirurgia de bloqueio ósseo para instabilidade anterior do ombro. Método Estudo retrospectivo no qual foram avaliados os resultados pós-operatórios de atletas submetidos a cirurgia de bloqueio ósseo para instabilidade anterior do ombro. Em 5 anos foram 41 ombros operados, sendo 20 deles com até 15% de defeito ósseo e 21 com defeitos entre 15% e 25%. Resultados Não houve diferença estatisticamente significativa com relação a complicações pós-operatórias, novas luxações, e na taxa de retorno ao esporte. Os critérios quantitativos avaliados - arcos de movimento e escores funcionais - também não apresentaram diferença estatisticamente significativa entre os grupos. Conclusão O tamanho do defeito ósseo por si só não parece afetar os resultados funcionais e as complicações desses procedimentos, sendo uma técnica segura tanto para defeitos pequenos, quanto para os maiores.


Subject(s)
Humans , Shoulder/surgery , Bone Transplantation , Athletes , Glenoid Cavity/surgery , Joint Instability/complications
2.
Rev. bras. ortop ; 57(4): 612-618, Jul.-Aug. 2022. tab, graf
Article in English | LILACS | ID: biblio-1394876

ABSTRACT

Abstract Objective To evaluate the correlation of the glenoid track and glenoidal bone loss with the recurrence dislocation rate and the Rowe score. Methods Retrospective study that assessed the glenoid track and glenoidal bone loss through preoperative magnetic resonance imaging. Patients undergoing primary arthroscopic repair of anterior Bankart were included. Patients with glenoidal bone loss greater than 21%, rotator cuff tear, scapular waist fracture, and posterior or multidirectional instability were not included. Rowe score were the primary outcome, and the recurrence rate was the secondary outcome. Results One hundred and two patients were included. Postoperative recurrent instability was reported by 8 patients (7.8%). Four patients (50%) in the group with recurrence presented glenoidal bone loss greater than 13.5% against 24 (25.5%) in the group without recurrence (p= 0.210), with a negative predictive value of 94.6%. Three patients (37.5%) in the recurrence group were considered off-track, against 13 (13.8%) in the group without recurrence (p= 0.109), with a negative predictive value of 94.2%. Patients with absolute glenoid track value ≤ 1.5 mm had worse results in relation to the recurrence group, with 6 patients (75%) presenting recurrence (p= 0.003). Conclusion Off-track injury and glenoidal bone loss greater than the subcritical are not related to the recurrence rate and Rowe score, despite the high negative predictive value. The cut of the absolute value of the glenoid track at 1.5 mm had a significant relationship with the recurrence rate.


Resumo Objetivo Avaliar a correlação do conceito de glenoid track e da perda óssea da cavidade glenoidal com a taxa de recidiva de luxação e pontuação na escala de Rowe. Métodos Estudo retrospectivo que aferiu o glenoid track e a perda óssea da cavidade glenoidal por ressonância magnética pré-operatória. Foram incluídos pacientes submetidos a reparo artroscópico primário de Bankart anterior. Não foram incluídos pacientes com perda óssea da cavidade glenoidal maior que 21%, rotura do manguito rotador, fratura de cintura escapular, instabilidade posterior ou multidirecional. A pontuação pela escala de Rowe foi o desfecho primário, e a taxa de recidiva foi o desfecho secundário. Resultados Cento e dois pacientes foram incluídos. A recidiva foi relatada por 8 pacientes (7,8%). Quatro pacientes (50%) do grupo com recidiva apresentaram lesão da cavidade glenoidal maior que 13,5% contra 24 (25,5%) do grupo sem recidiva (p= 0,210), com valor preditivo negativo de 94,6%. Três pacientes (37,5%) do grupo com recidiva foram considerados off-track, contra 13 (13,8%) do grupo sem recidiva (p= 0,109), com valor preditivo negativo de 94,2%. Pacientes com valor absoluto do glenoid track menor ou igual a 1,5 mm tiveram piores resultados em relação ao grupo com recidiva, sendo que 6 pacientes (75%) apresentaram recidiva (p= 0,003). Conclusão Lesão off-track e perda óssea da cavidade glenoidal maior que a subcrítica não apresentam relação significativa com a taxa de recidiva e a pontuação de Rowe, apesar do alto valor preditivo negativo. O corte do valor absoluto do glenoid track em 1,5 mm apresentou relação significativa com a taxa de recidiva.


Subject(s)
Humans , Male , Female , Shoulder Dislocation/therapy , Glenoid Cavity , Bankart Lesions
3.
Rev. bras. ortop ; 57(1): 14-22, Jan.-Feb. 2022. tab, graf
Article in English | LILACS | ID: biblio-1365757

ABSTRACT

Abstract Much is discussed about the limits of the treatment of anterior shoulder instability by arthroscopy. The advance in understanding the biomechanical repercussions of bipolar lesions on shoulder stability, as well as in the identification of factors related to the higher risk of recurrence have helped us to define, more accurately, the limits of arthroscopic repair. We emphasize the importance of differentiation between glenoid bone loss due to erosion (GBLE) and glenoid edge fractures, because the prognosis of treatment differs between these forms of glenoid bone failure. In this context, we understand that there are three types of bone failure: a) bone Bankart (fracture); b) combined; and c) glenoid bone loss due to anterior erosion (GBLE), and we will address the suggested treatment options in each situation. Until recently, the choice of surgical method was basically made by the degree of bone involvement. With the evolution of knowledge, the biomechanics of bipolar lesions and the concept of glenoid track, the cutoff point of critical injury, has been altered with a downward trend. In addition to bone failures or losses, other variables were added and made the decision more complex, but a little more objective. The present update article aims to make a brief review of the anatomy with the main lesions found in instability; to address important details in arthroscopic surgical technique, especially in complex cases, and to bring current evidence on the issues of greatest divergence, seeking to guide the surgeon in decision making.


Resumo Muito se discute sobre os limites do tratamento da instabilidade anterior do ombro por artroscopia. O avanço no entendimento das repercussões biomecânicas das lesões bipolares sobre a estabilidade do ombro, bem como na identificação de fatores relacionados ao maior risco de recidiva têm nos ajudado a definir, de forma mais apurada, os limites do reparo por via artroscópica. Ressaltamos a importância de diferenciação entre perda óssea por erosão da glenoide (POAG) e fraturas da borda da glenoide, pois o prognóstico do tratamento diverge entre essas formas de falha óssea da glenoide. Neste contexto, entendemos que há três tipos de falha óssea: a) Bankart ósseo (fratura); b) combinada; e c) POAG, e abordaremos as opções de tratamento sugerido em cada situação. Até há pouco tempo, a escolha do método cirúrgico era norteada basicamente pelo grau de acometimento ósseo. Com a evolução do conhecimento, da biomecânica das lesões bipolares e do conceito do glenoid track (trilho da glenoide), o ponto de corte da lesão crítica, vem sendo alterado com tendência de queda. Além das falhas ou perdas ósseas, outras variáveis foram adicionadas e tornaram a decisão mais complexa, porém um pouco mais objetiva. O presente artigo de atualização tem como objetivo fazer uma breve revisão da anatomia com as principais lesões encontradas na instabilidade; abordar detalhes importantes na técnica cirúrgica artroscópica, em especial nos casos complexos, e trazer as evidências atuais sobre os assuntos de maior divergência, buscando guiar o cirurgião na tomada de decisão.


Subject(s)
Arthroscopy , Shoulder Dislocation , Shoulder Joint , Glenoid Cavity , Rotator Cuff Injuries , Shoulder Injuries
4.
Acta ortop. bras ; 30(4): e247095, 2022. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1393787

ABSTRACT

ABSTRACT Introduction: Scapular fractures are rare injuries and are often associated with high-energy trauma, with joint fractures accounting for only 15% of all scapular fractures. Surgical treatment is indicated for fractures with large deviations and with joint instability. Objective: This study evaluates the clinical and functional results after surgical treatment of scapular fractures. Methods: Eight patients with scapular fractures were surgically treated between 2013 and 2019. For indication for surgical treatment, mediolateral deviations, glenopolar angle, angular deviations and joint deviations greater than 4 mm were taken into account. Radiographic results of consolidation, range of motion, functional score and visual analogue pain scale were obtained. Results: In the mean follow-up of twenty-nine months (13-40 months), all patients presented fracture consolidation. The mean UCLA score was 29 points (with 75% good results and 25% moderate results). Regarding the range of motion, the mean elevation was 146° (ranging from 110° to 60°), lateral rotation of 62° (36-80°) and medial rotation at the level of T7 (T6-T10). The final VAS mean was 2.3. All patients returned to the pre-injury level at work. Conclusion: In this series of cases, surgical treatment of scapular articular fractures provided satisfactory results with low rates of complications, showing to be an option in selected cases of deviated fractures. Level of Evidence IV, Case Series.


RESUMO Introdução: As fraturas de escápula são lesões raras e muitas vezes associadas a traumas de alta energia, sendo que as fraturas articulares correspondem a apenas 15% de todas fraturas escapulares. O tratamento cirúrgico é indicado para fraturas com grandes desvios e com instabilidade articular. Objetivo: Avaliar os resultados clínicos e funcionais após o tratamento cirúrgico das fraturas de escápula. Métodos: Oito pacientes com fraturas da escápula foram tratados cirurgicamente entre o período de 2013 e 2019. Para indicação do tratamento cirúrgico, levou-se em consideração os desvios mediolaterais, ângulo glenopolar, desvios angulares e desvio articular maior que 4 mm. Resultados radiográficos de consolidação, arco de movimento, escore funcional e escala visual analógica de dor foram obtidos. Resultados: No seguimento médio de 29 meses (13-40 meses), todos os pacientes apresentaram consolidação da fratura. A média do escore UCLA foi de 29 pontos (sendo 75% de resultados bons e 25% de resultados moderados). Com relação ao arco de movimento, a elevação média foi de 146° (variando de 110° a 160°), rotação lateral de 62° (36-80°) e rotação medial no nível de T7 (T6-T10). A média final do EVA foi de 2,3. Todos os pacientes retornaram ao nível pré-lesão de trabalho. Conclusão: Nesta série de casos, o tratamento cirúrgico das fraturas da escápula com envolvimento articular proporcionou resultados satisfatórios com baixa taxas de complicações, mostrando ser uma opção em casos selecionados de fraturas desviadas. Nível de Evidência IV, Série de Casos.

5.
Rev. bras. ortop ; 56(6): 733-740, Nov.-Dec. 2021. tab, graf
Article in English | LILACS | ID: biblio-1357128

ABSTRACT

Abstract Objective To evaluate and compare the glenoid track method in 3D-reconstructed computed tomography (3D-CT) scans with magnetic resonance imaging (MRI) and/or arthro-MRI. Methods Forty-four shoulders with clinical and radiographic diagnosis of traumatic anterior instability were assessed using 3D-CT, MRI, and/or arthro-MRI scans. Glenoid track (GT), Hill-Sachs interval (HSI), and glenoid bone loss (GBL) were determined by a radiologist using 3D-CT images, and classified as on-track/off-track. Three surgeons, blinded to the radiologist's evaluation, performed the same determinations using MRI/arthro-MRI. Descriptive analysis, variance analysis, results disagreement analysis, and receiver operating characteristic (ROC) curves were performed. Results Results from the 4 examiners were fully consistent in 61.4% of the cases. Magnetic resonance imaging/arthro-MRI diagnosed off-track injuries with 35 to 65% sensitivity and on-track injuries, with 91.67 to 95.83% specificity. Accuracy ranged from 68.1 to 79.5%. The greatest data divergence occurred for off-track injuries diagnosed by MRI/arthro-MRI. The greatest data variability referred to HSI calculation. Higher HSI and GBL values were associated with greater disagreement among examiners. Hill-Sachs interval values were lower at MRI/arthro-MRI when compared to 3D-CT. Agreement between CT and MRI/arthro-MRI for the GT method was only moderate (kappa value, 0.325-0.579). Conclusion Magnetic resonance imaging/arthro-MRI showed low accuracy and moderate agreement for the GT method; as such, it should be used with caution by surgeons.


Resumo Objetivo Comparar a avaliação do método glenoid-track (GT) em exames de tomografia computadorizada com reconstrução 3-D (TC-3D) com a avaliação realizada em exames de ressonância magnética (RM) e/ou artro-ressonância magnética (ARM). Métodos Quarenta e quatro ombros com diagnóstico clínico e radiográfico de instabilidade anterior traumática foram avaliados por meio de exames de TC-3D, RM e/ou ARM. As variáveis GT, intervalo de Hill-Sachs (IHS) e a perda óssea da glenoide (POG) foram realizadas por um médico radiologista, utilizando imagens de TC-3D, e classificadas em on-track/off-track. Três cirurgiões cegos à avaliação do radiologista realizaram o mesmo método utilizando RM/ARM. O estudo realizou análise descritiva, de variância, de associação da discordância de resultados, de concordância e curva característica de operação do receptor. Resultados Os resultados dos 4 examinadores foram totalmente concordantes em 61,4%. A RM/ARM diagnosticou lesões off-track com a sensibilidade variando de 35 a 65%, e lesões on-track com a especificidade variando de 91,67 a 95,83%. A acurácia variou de 68,1 a 79,5%. A maior divergência de dados ocorreu para o diagnóstico por RM/ARM de lesões off-track. A maior variabilidade dos dados ocorreu para o cálculo do IHS. Valores maiores de IHS e de POG foram associados a maior discordância entre os examinadores. A RM/ARM apresentou menor medida de valores de IHS quando comparado com a TC-3D. Ocorreu apenas moderada concordância no método GT entre a TC e a RM/ARM (Kappa 0,325-0,579). Conclusão A RM/ARM apresentou baixa acurácia e moderada concordância para o método GT, devendo ser utilizada com cautela por cirurgiões.


Subject(s)
Humans , Magnetic Resonance Spectroscopy , Tomography, X-Ray Computed , Clinical Diagnosis , Glenoid Cavity , Shoulder Injuries
6.
Rev. bras. ortop ; 55(2): 215-220, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1138016

ABSTRACT

Abstract Objectives The aim of the present study was to describe the dimensions of the coracoid grafts in our Latarjet surgeries and compare them with the results described in the literature. In addition, the feasibility of the 7-millimeter rule was verified. Methods Individuals with anterior glenohumeral instability with or without bone loss participated in the present study. The dimensions of 31 coracoid process grafts of patients who were submitted to the Latarjet surgical technique were measured with an analogical caliper and recorded for posterior analysis. Results The dimensions of the coracoid graft did not show statistically significant differences related to gender. The graft width obtained from our sample presented similarities with the dimensions reported in the literature. However, the length and thickness were smaller when compared to the reference study (Young et al, 2013).15 The 7-millimeter rule was considered feasible regarding the graft dimensions obtained from our sample. Conclusion The coracoid graft dimensions were similar to the dimensions described in the literature regarding width, but the same was not found for length and thickness; and the 7-millimeter rule was feasible regarding the graft dimensions obtained from our sample.


Resumo Objetivo O objetivo deste estudo foi descrever as dimensões do processo coracoide em nossas cirurgias de Latarjet e compará-las com os resultados descritos na literatura. Além disso, a viabilidade da regra dos 7 milímetros foi verificada. Métodos Indivíduos com instabilidade glenoumeral anterior com ou sem erosão óssea participaram deste estudo. As dimensões de 31 enxertos de processo coracoide de pacientes operados pela técnica de Latarjet foram mensuradas com um paquímetro analógico e registradas para análise posterior. Resultados As dimensões do processo coracoide não demonstraram diferença estatisticamente significativa de acordo com o sexo. A largura do enxerto obtida em nossa amostra apresentou semelhança com as dimensões descritas na literatura. No entanto, o comprimento e a espessura foram um pouco menores quando comparados com o estudo de referência (Young et al, 2013).15 A regra dos 7 milímetros foi considerada viável com as dimensões do enxerto obtidas em nossa amostra. Conclusão As dimensões do enxerto do coracoide foram similares às descritas na literatura em relação à largura, mas o mesmo não foi encontrado quanto ao comprimento e espessura; e a regra dos 7 milímetros demonstrou viabilidade com as dimensões do enxerto obtidas em nossa amostra.


Subject(s)
Humans , Male , Female , Shoulder Dislocation , Shoulder Joint , Bone and Bones , Bone Transplantation , Glenoid Cavity , Gender Identity , Joint Instability
7.
Rev. bras. ortop ; 50(4): 445-449, July-Aug. 2015. tab, ilus
Article in English | LILACS | ID: lil-761108

ABSTRACT

Avaliar a influência da amplitude de movimento do cotovelo e do antebraço na excursão distal da cabeça longa do bíceps (CLB). MÉTODOS: Verificou-se a excursão distal da cabeça longa do bíceps (CLB) após tenotomia em ombros de oito cadáveres, por meio da aferição da distância entre um ponto demarcado na cabeça longa do bíceps (CLB) a 3 cm da borda anterolateral do acrômio em flexão máxima e sua posição em diferentes graus de flexão do cotovelo, com o uso de um paquímetro digital. Foram anotadas as medidas nos graus de flexão do cotovelo 135°, 90°, 45° e 0°, estabelecidas com o uso de um goniômetro. As medidas foram tomadas com o antebraço em posição neutra, supinação e pronação. RESULTADOS: Observou-se diferença entre as médias das medidas da excursão distal da cabeça longa do bíceps (CLB) (amostra total) entre os graus de flexão do cotovelo (p < 0,01). Todavia, não foi encontrada diferença estatística entre diferentes posições do antebraço, entre os lados, gêneros e idades dos cadáveres estudados. CONCLUSÃO: A extensão progressiva do cotovelo ocasionou a excursão distal progressiva da cabeça longa do bíceps (CLB), mas sem interferência da posição do antebraço, gênero, lado e idade dos cadáveres estudados.


To evaluate the influence of elbow and forearm range of motion on the distal excursion of the long head of the biceps (LHB). METHODS: The distal excursion of the LHB after tenotomy of the shoulders of eight cadavers was ascertained by measuring the distance between a point marked out on the LHB, 3 cm from the anterolateral border of the acromion, and its position at different degrees of elbow flexion, using a digital pachymeter. The measurements at elbow flexion of 135°, 90°, 45° and 0° were noted: these angles were established using a goniometer. The measurements were made with the forearm in neutral, supination and pronation positions. RESULTS: Differences between the mean measurements of the distal excursion of the LHB (total sample) were observed between the degrees of elbow flexion ( p< 0.01). However, no statistical differences were observed between the different forearm positions, between the sides, genders and ages of the cadavers studied. CONCLUSION: Progressive extension of the elbow caused progressive distal excursion of the LHB, but without interference in the forearm position, gender, side or age of the cadavers studied.


Subject(s)
Cadaver , Glenoid Cavity , Shoulder Joint , Tenotomy
SELECTION OF CITATIONS
SEARCH DETAIL
...