Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Braz. dent. sci ; 27(1): 1-8, 2024. ilus, tab
Article in English | LILACS, BBO - Dentistry | ID: biblio-1554218

ABSTRACT

Objective: The aim of this study was to evaluate the marginal gap of frameworks produced using the CAD-CAM system, from zirconia and lithium disilicate blocks, adapted to a tooth preparation and a gypsum die. Material and Methods: For this study, a human first molar tooth was used as a master model with a full crown preparation. It was molded 20 times to obtain the gypsum die and randomly divided into 2 groups (n=10) for the fabrication of zirconia and lithium disilicate frameworks. The frameworks were made using pre-sintered zirconia blocks and lithium disilicate blocks, both CAD-CAM systems. The marginal gap was measured in µm at four points (buccal, palatal, mesial, and distal) using a comparator microscope with 30x magnification, with the framework seated on the master model (tooth), and on the gypsum die. Marginal gap data (µm) were evaluated using two-way analysis of variance and Tukey's test with a significance level of 5%. Results: The results showed that there was no statistically significant interaction between the factors studied (p=0.223) or isolated factors (ceramic factor p=0.886 and die factor p=0.786). Conclusion: Both ceramics produced using the CAD-CAM technique did not exhibit statistical differences in marginal adaptation on the two types of substrates, both on tooth preparation and on the gypsum die (AU)


Objetivo: O objetivo deste estudo foi avaliar o espaço marginal de estruturas produzidas usando o sistema CAD-CAM, a partir de blocos de zircônia e dissilicato de lítio, adaptadas a um preparo sobre dente e a um troquel de gesso. Material e Métodos: Para este estudo, um dente molar humano foi utilizado como modelo mestre com preparo para coroa total. Este foi moldado 20 vezes para obter o troquel de gesso e dividido aleatoriamente em 2 grupos (n=10) para a fabricação de estruturas de zircônia e dissilicato de lítio. As estruturas foram feitas usando blocos de zircônia pré-sinterizados e blocos de dissilicato de lítio, ambos sistemas para CAD-CAM. O espaço marginal foi medido em µm, em quatro pontos (bucal, palatal, mesial e distal), utilizando um microscópio comparador com ×30 de ampliação e com a estrutura assentada no modelo mestre (dente) e no troquel de gesso. Os dados de espaço marginal (µm) foram avaliados usando análise de variância bidirecional e teste de Tukey com um nível de significância de 5%. Resultados: Os resultados mostraram que não houve interação estatisticamente significativa entre os fatores estudados (p=0,223) ou isoladamente (fator cerâmica p=0,886 e fator troquel p=0,786). Conclusão: Ambas as cerâmicas produzidas usando a técnica CAD-CAM não apresentaram diferenças estatísticas em relação à adaptação marginal nos dois tipos de substratos, tanto na preparação dentária quanto no troquel de gesso(AU)


Subject(s)
Dental Prosthesis , Computer-Aided Design , Dental Marginal Adaptation , Dental Porcelain
2.
São José dos Campos; s.n; 2023. 71 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1452281

ABSTRACT

Este estudo avaliou o efeito do jateamento com óxido de alumínio prévio à camada de caracterização no comportamento adesivo e mecânico de zircônias de segunda e terceira gerações. Na parte A, foi realizado um estudo de resistência flexural. Para isso, discos de cada zircônia (3Y-TZP, 4Y-PSZ ou 5YPSZ) foram confeccionados. Após polimento e sinterização, os discos foram divididos de acordo com os tratamentos de superfície: Polimento, Jateamento com Al2O3 50 µm e Jateamento com Al2O3 110 µm (n = 30). A superfície tratada de todos os discos recebeu uma fina camada de pigmentação e uma fina camada de glaze. O ensaio de flexão biaxial foi realizado na configuração pistonon-three-balls e as superfícies fraturadas foram observadas em Microscopia Eletrônica de Varredura (MEV). Os dados foram submetidos à Análise de Weibull. Na parte B, avaliou-se o efeito dos diferentes tratamentos de superfície prévio à camada de caracterização no comportamento à fadiga das diferentes zircônias. Discos de 3Y-TZP, 4Y-PSZ e 5Y-PSZ foram confeccionados e distribuídos entre os tratamentos de superfície: Polimento ou Jateamento Al2O3 50 µm (n = 15), que foram realizados conforme a parte A deste estudo. Os discos foram cimentados adesivamente a um análogo de dentina (NEMA G10). Os testes de fadiga foram realizados pelo método stepwise, com aplicação de carga axial por um pistão hemisférico (carga inicial: 400 N, step: 100 N, ciclos/step: 10.000, frequência: 20 Hz). Na parte C, avaliou-se a resistência de união entre as diferentes zircônias e a camada de caracterização. Foram preparados os mesmos grupos descritos na "parte A" (n = 15). Cilindros de stain seguido por glaze foram construídos nas superfícies das zircônias. A resistência de união foi avaliada pelo teste de cisalhamento. Os tipos de falha (adesiva, predominantemente adesiva ou coesiva) foram analisados em estereomicroscópio e MEV. Análises complementares em perfilômetro e goniômetro foram realizadas. Para a parte A, o jateamento com Al2O3 110 µm aos menores valores de resistência à flexão, seguido do jateamento com as partículas de Al2O3 50 µm. Os maiores valores foram observados no grupo que não recebeu jateamento prévio à camada de caracterização. Esses resultados foram observados em todos os materiais. Na parte B, o jateamento com Al2O3 reduziu significativamente a carga e o número de ciclos para falha em fadiga de todos os materiais. Na parte C, os melhores valores de resistência de união foram atribuídos para o tratamento de superfície com Al2O3 110 µm, seguido de jateamento com Al2O3 50 µm e polimento. Dessa forma, o jateamento prévio à camada de caracterização reduz a resistência mecânica de zircônias de segunda geração e melhora a resistência de união entre os dois materiais (AU)


This study evaluated the effect of aluminum oxide sandblasting prior to the characterization layer on the adhesive and mechanical behavior of second- and third-generation zirconia. Part A consisted of a flexural strength study. Discs of each zirconia (3Y-TZP, 4Y-PSZ, or 5Y-PSZ) were prepared. After polishing and sintering, the discs were divided according to the surface treatments: Polishing, Sandblasting with Al2O3 50 µm and Sandblasting with Al2O3 110 µm (n = 30). The treated surface of all discs received a thin layer of stain and a thin layer of glaze. The biaxial bending test was performed in a piston-on-three-balls set-up. The fractured surfaces were observed by Scanning Electron Microscopy (SEM). Data were subjected to Weibull Analysis. In part B, the effect of different surface treatments prior to the characterization layer on the fatigue behavior of different zirconia was evaluated. Discs of 3Y-TZP, 4Y-PSZ and 5Y-PSZ were prepared and divided among the surface treatments: Polishing or Sandblasting Al2O3 50 µm (n = 15), which were performed according to part A of this study. The discs were adhesively cemented to a dentin-analogue (NEMA G10). Fatigue tests were performed using the stepwise method, with an axial load application by a hemispherical piston (initial load: 400 N, step: 100 N, cycles/step: 10,000, frequency: 20 Hz). Part C evaluated the bond strength between the different zirconia and the characterization layer. The same groups described in part A (n = 15) were prepared. Stain cylinders followed by glaze were built on the zirconia surfaces. The bond strength was evaluated by the shear test. The types of failure (adhesive, predominantly adhesive or cohesive) were analyzed using a stereomicroscope and SEM. Complementary analyzes in profilometer and goniometer were carried out. In part A, sandblasting with Al2O3 110 µm led to the lowest flexural strength results, followed by sandblasting with Al2O3 50 µm. Polishing group achieved the highest values. These results were observed in all tested ceramics. In part B, sandblasting with Al2O3 50 µm significantly reduced the fatigue failure load and the number of cycles for fatigue failure. In part C, the highest bond strength results were reached by sandblasting with Al2O3 110 µm, followed by sandblasting with Al2O3 50 µm, and polishing. Therefore, aluminum oxide particles sandblasting diminishes the mechanical behavior of second- and third-generation zirconias and improves the bond strength between the two materials. (AU)


Subject(s)
Dental Materials , Mechanical Tests
3.
São José dos Campos; s.n; 2021. 70 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-1359883

ABSTRACT

O objetivo deste trabalho foi avaliar a resistência à fadiga e ciclos até a falha de 3 zircônias odontológicas após envelhecimento hidrotérmico isolado e um novo protocolo alternado. Discos de zircônia "Y"Z T (VITA), INCORIS "T"ZI (Dentsply Sirona) e "K"ATANA UTML (Noritake Kuraray) (N=135) ­ 1ª, 2ª e 3ª gerações, respectivamente ­, foram divididos em 9 grupos (n=15), com 3 tratamentos para cada zircônia: CF ­ Controle, somente com fadiga mecânica; EF ­ Envelhecido em reator hidrotérmico a 134 ºC por 20 h + Fadiga; EFA: 4 passos de envelhecimentos de 5h alternados com fadiga. O teste de fadiga em flexão biaxial foi realizado com configuração de pistão sob 3 esferas, utilizando o método step-stress (carga inicial: 100 Mpa, step: 50 MPa/10.000 ciclos, frequência: 20 Hz). Os dados foram analisados através de teste Kaplan-Meir e Mantel-Cox com α=0,05, além da análise de Weibull. Discos fraturados foram analisados em estereomicroscópio, Microscopia Eletrônica de Varredura (MEV) e Difratômetro de Raios-X (DRX). O envelhecimento isolado com fadiga aumentou a resistência do grupo TEF (810 ± 76 MPa), enquanto diminuiu a do YEF (516 ± 38 MPa), o protocolo alternado aumentou a resistência apenas para a YZ T (730 ± 59 MPa). A KATANA UMTL não apresentou diferenças para ambos os tratamentos. Igualmente, foi a única a não sofrer transformação de fase T-M. O grupo TEF apresentou maior taxa sobrevivência à fadiga (147,000.00 ciclos). A origem de fratura para todos os espécimes deu-se no lado de tração em defeitos pré-existentes. Zircônias de 2ª geração possuem melhor comportamento mecânico e longevidade pós-envelhecimento e fadiga. Embora seja menos resistente, a KATANA UTML não sofreu degradação


This study aimed to evaluate the fatigue strength and cycles for failure of 3 dental zirconias after isolated and a novel hydrothermal and mechanical fatigue cycling aging protocol. "Y"Z T (VITA), INCORIS "T"ZI (Dentsply Sirona) and "K"ATANA UTML (Noritake Kuraray) zirconia discs (N=135), were divided into 9 groups (n=15), according to 3 proposed treatments for each zirconia: CF (control ­ only mechanical fatigue cycling); AF (aging in hydrothermal reactor at 134°C for 20 h + mechanical fatigue cycling ); AFA (Alternating protocol: 4 steps of 5 h of hydrothermal aging intercalated with mechanical fatigue cycling). Mechanical fatigue aging was performed according to the step stress approach through biaxial flexural setup (piston-on-3-balls, initial strength: 100 MPa, step: 50 MPa/ci000, frequency: 20 Hz) until failure. Data were analyzed using KaplanMeier and Mantel-Cox test (α=0.05), in addition to Weibull analysis. Fractured discs were analyzed in stereomicroscope, Scanning Electron Microscopy and XRay Diffraction. Continuous hydrothermal and mechanical fatigue cycling decreased the fatigue strength of YAF group (516 ± 38 MPa), while the alternating protocol increased it (730 ± 59 MPa). KATANA UTML showed no differences for both treatments and did not undergo T-M phase transformation. The TAF group showed the highest fatigue strength (810 ± 76 MPa) and cycles for failure (147,000.00 cycles). The fracture origin for all specimens was on the tensile side in pre-existing defects. INCORIS TZI zirconia have higher fatigue strength after hydrothermal and mechanical fatigue aging. Although less resistant, KATANA UTML did not suffer chemical degradation


Subject(s)
Tensile Strength , Zirconium/chemistry , Materials Testing , Ceramics , X-Ray Diffraction , Biocompatible Materials/analysis , Microscopy, Electrochemical, Scanning
4.
Natal; s.n; 2018. 63 p. tab, ilus, graf.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1437689

ABSTRACT

Introdução: As restaurações em zircônia monolítica podem exigir ajustes em sua estrutura antes da cimentação. Diversos métodos de acabamento e polimento são sugeridos na literatura, entretanto estes podem promover mudanças estruturais e na superfície da zircônia, o que pode afetar a resistência mecânica do material em longo prazo. Objetivo: Investigar in vitro o efeito de diferentes regimes de acabamento e polimento e da degradação em baixas temperaturas na resistência à flexão e topografia superficial em dois tipos de zircônia monolíticas. Metodologia: 300 barras de zircônia (Z: ice zirkon transluzent/Convencional e UT: Prettau Anterior/Ultratranslúcida, zirkonzahn, Gais, Itália) foram confeccionadas nas dimensões 2,1- 1,3x 2,5x10mm, lixadas e sinterizadas, apresentando dimensões finais de 1,7-1 x 2 x 8mm, divididas em 20 grupos (n=15) de acordo com três fatores: "Zircônia"-2 níveis (Z: Convencional; UT: Ultratranslúcida), "Acabamento e Polimento"- 5 níveis (C- Controle; BBorrachas; P- Asperização com pontas; PB- Asperização com pontas + Borrachas; PGAsperização com pontas + glaze) e "Degradação"- 2 níveis (COMD: autoclave à 127°C, 1,7 bar /24h; sem degradação). Foi realizado o ensaio de resistência à miniflexão (3 pontos), com v:1mm/min e células de carga 500N e 5000N. Duas amostras de cada grupo foram preparadas para microscopia eletrônica de varredura (MEV)/ Espectrometria por Energia Dispersiva de Raios-X (EDS) e microscopia de força atômica (MFA). A rugosidade média de cada grupo foi avaliada qualitativamente. Os dados foram analisados por ANOVA (3 fatores) e Tukey (5%). Resultados: Os fatores "Zircônia" (p=0,0000), "Acabamento e Polimento" (p=0,0000) e "Degradação" (p=0,01) e foram estatisticamente significantes, sendo as maiores médias encontradas nos grupos ZPBD (1670.2 ± 252.73)A , ZBD (1663.5 ± 216.80)A e ZB (1654.7 ± 367.79A ) e as menores na zircônia UT, destacando-se o grupo UTPG (372.1±56.295)G . No MEV pode-se observar que a camada de glaze não recobriu toda superfície da zircônia e as borrachas promoveram uma superfície mais uniforme. O EDS revelou maior quantidade de óxido de ítrio nas zircônias UT, já na MFA maior valor de Ra foi encontrado nos grupos asperizados, sendo UT>Z. Conclusão: O protocolo mais indicado para acabamento e polimento das restaurações em zircônia são o uso de borrachas diamantadas. A asperização seguida pelo glaze reduziu a resistência da zircônia e o uso das borrachas forneceram uma superfície mais uniforme em relação aos demais métodos (AU).


Background: The restorations in monolithic zirconia may require adjustments in their structure prior to cementation. Several methods of finishing and polishing are suggested in the literature, however they can promote structural and surface changes of the zirconia, which can affect the mechanical strength of the material in the long term. Aim: To investigate in vitro the effect of different finishing and polishing regimes and low temperature degradation on flexural strength and surface topography in two types of monolithic zirconia. Method: 300 zirconia bars (Z: ice zirkon transluzent / Conventional and UT: Prettau Anterior / Ultratransluzent, zirkonzahn, Gais, Italy) were made in sizes 2.1-1.3x 2.5x10mm, sanded and sintered, (Z: Conventional; UT: Ultratransluzent), "Finishing and Polishing" - 5 levels (C- Control, B- diamond polishers, Pgrinding with burs, PB- grinding with burs + diamond polishers, PG- grinding with burs + glaze) and "Degradation" - 2 levels (WithD: autoclave at 127 ° C, 1,7 bar / 24h, without degradation). The miniflexion resistance test (3 points) was performed, with v: 1mm / min and 500N and 5000N load cells. Two samples from each group were prepared for Scanning Electron Microscopy (SEM) / X-ray Dispersive Energy Spectrometry (EDS) and Atomic Force Microscopy (AFM). The mean roughness of each group was evaluated qualitatively. Data were analyzed by ANOVA (3 factors) and Tukey (5%). Results: The "Zirconia" (p = 0.0000), "Finishing and Polishing" (p = 0.0000) and "Degradation" factors (p = 0.01) were statistically significant, ZBD (1670.2 ± 252.73)A , ZBD (1663.5 ± 216.80)A and ZB (1654.7 ± 367.79A ) and the lowest in the UT zirconia, standing out the UTPG group (372.1 ± 56.295)G . In the SEM it can be observed that the glaze layer did not cover the whole surface of the zirconia and the diamond polishers promoted a more uniform surface. The EDS showed higher amount of yttrium oxide in the UT zirconia and the AFM showed the higher Ra value was found in the roughened groups, with UT> Z. Conclusion: The most suitable protocol for finishing and polishing restorations in zirconia is the use of diamond polishers. The grinding followed by glaze reduced zirconia resistance and the use of the diamond polishers provided a more uniform surface compared to the other methods (AU).


Subject(s)
Zirconium/chemistry , Ceramics , Dental Materials , Flexural Strength , In Vitro Techniques/methods , Microscopy, Electron, Scanning/instrumentation , Analysis of Variance , Microscopy, Atomic Force
5.
São José dos Campos; s.n; 2018. 93 p. il., tab., graf..
Thesis in Portuguese | BBO - Dentistry | ID: biblio-905937

ABSTRACT

Com o avanço da ciência e processamento de materiais, a zircônia odontológica deixou de ser um material opaco para apresentar certa translucidez, possibilitando a confecção de peças ultrafinas. Sabe-se que a água em contato com a superfície das zircônias convencionais acarreta na transformação de fase T-M e subsequente decréscimo de resistência, mas esses efeitos nas zircônias translúcidas ainda não foram explorados. Para avaliar, mapear e caracterizar os efeitos da cinética de envelhecimento acelerado em zircônias de alta translucidez, foram cortados 39 blocos de Y-TZP (VITA YZ, VITA HT, InCoris TZI) para cada zircônia comercial, onde posteriormente foram sinterizados (1530 ºC, 2h) e atribuídos a 13 grupos com 3 amostras cada: Um controle e 12 envelhecidos hidrotermicamente a 134 ºC com pressão constante de 2 bars por 6, 10, 14, 18, 22, 26, 30, 40, 60, 80, 100 e 140 horas. A análise em DRX foi utilizada para quantificar a transformação de fase da zircônia (tetragonal-monoclínica) em diferentes profundidades do material ao se trocar o ânodo do tubo irradiador (Cr, Co e Cu). Uma curva cinética de envelhecimento foi feita para cada profundidade para as 3 zircônias comerciais. Para avaliar os efeitos do envelhecimento hidrotermal nas propriedades mecânicas, 270 discos de Y-TZP foram cortados, 90 para cada tipo, sinterizados e atribuídos a 3 grupos: C-Controle; E1- envelhecido até 26h e E2- envelhecido até 140 horas. Os discos foram testados em uma máquina de teste universal (EMIC). A microestrutura dos discos foi avaliada sob MEV. As curvas de cinética do envelhecimento funcionaram de forma semelhante para todas as zircônias utilizadas neste estudo, caracterizadas por uma rápida transformação de fase T-M em função do tempo e estabilização de um platô após uma média de 26 horas. As camadas superficiais apresentam concentrações mais elevadas de fase monoclínica à medida em que essa concentração diminuiu em camadas mais profundas. O envelhecimento hidrotermal através de 140h diminuiu a tenacidade da cerâmica VITA YZ em 17% (681,78 ± 121,18) quando comparado ao seu grupo controle (841,69 ± 56,01), enquanto que as zircônias de alta translucidez não mostraram diferenças estatísticas de resistência flexural após o envelhecimento. O envelhecimento hidrotermal induz a transformação da fase martensítica de fora para dentro do material e não afeta as propriedades mecânicas das cerâmicas VITA HT e INCORIS TZI, enquanto diminui a dureza do material da zircônia VITA YZ(AU)


To evaluate, map and characterize the effects of the accelerated aging kinetics of high translucency zirconias, this study was split into 2 parts: One part evaluating the superficial changes after in vitro hydrothermal aging and the second part aiming the effects of this aging on the mechanical properties of those ceramics. 117 Y-TZP (VITA YZ, VITA HT, InCoris TZI) blocks were cut, 39 for each commercial zirconia, sintered (1530 ºC, 2h) and assigned to 13 groups with 3 samples each: One being a control, aging-free group, and 12 groups that were prematurely aged hydrothermally at 134 ºC and constant pressure of 2 bars through 6, 10, 14, 18, 22, 26, 30, 40, 60, 80, 100 and 140 hours. XRD was used to quantify the amount of zirconia phase transformation (tetragonalmonoclinic) on different depths of the material by swapping the anode tube (Cr, Co, and Cu). An aging kinetic curve was made for each depth for the 3 commercial zirconias. To evaluate the effects of the hydrothermal aging on the mechanical properties, Y-TZP blocks were rounded to a cilindrical shape. 270 discs were cut, 90 for each kind, sintered as mentioned above and assigned to 3 groups: C-Control; E1- Aged through 26h and E2- Aged through 140h. Disks were then tested in a universal testing machine (EMIC) under a load of 1000 kg till fracture of the specimen and the surface was evaluated under SEM. The aging kinetics curves work similarly for all the YTZP used in this study, characterized by phase transformation ascendant and plateau stabilization as far as the aging goes. Superficial layers present higher concentrations of monoclinic phase as it decreases in deeper layers. Hydrothermal aging through 140h decreased VITA YZ toughness by 17% (681,78 ± 121,18) when compared with its control group (841,69 ± 56,01), while high translucency zirconias didn't show any statistical differences after aging.Hydrothermal aging does induce martensitic phase transformation from the outside-to-inside the material and doesn't affect the mechanical properties of VITA HT and INCORIS TZI ceramics, while it decreased the material toughness of VITA YZ zirconia(AU)


Subject(s)
Humans , Biomedical and Dental Materials/chemical synthesis , Ceramics/analysis
6.
Bauru; s.n; 2015. 75 p. ilus, tab, graf.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-867412

ABSTRACT

Materiais cerâmicos têm sido utilizados rotineiramente na clínica restauradora. A capacidade de adesão à sistemas adesivos de cimentação é um dos fatores críticos para o sucesso clínico. O objetivo do presente estudo foi avaliar as propriedades de adesão à um sistema de cimentação adesiva de dois materiais vitrocerâmicos experimentais, sendo um reforçado por dissilicato de lítio (D) e outro por metassilicato de lítio (M) para aplicação odontológica. Para tal, objetivou-se determinar a influência de diferentes tratamentos de superfície na resistência de união a um sistema de cimentação adesiva através de ensaios de microtração e caracterizar as alterações morfológicas decorrentes dos diferentes tratamentos de superfície testados. Três tratamentos de superfícies para cada material experimental foram selecionados: 1- jateamento com partículas de Al2O3 (J), 2- ataque ácido com ácido hidrofluorídrico a 10% por 20 segundos (20) e 3- ataque ácido com ácido hidrofluorídrico a 10% por 60 segundos (60). Um grupo do material comercial IPS e.max CAD (Ivoclar-Vivadent) foi utilizado como controle, seguindo as instruções do fabricante para o tratamento de superfície. As alterações morfológicas na superfície das cerâmicas foram analisadas por microscopia eletrônica de varredura (MEV) e demonstraram que os materiais experimentais são ácido sensíveis e sofreram modificações topográficas com o jateamento. Para os ensaios de microtração, os blocos das cerâmicas experimental e comercial tiveram suas superfícies condicionadas e silanizadas com o Agente Silano Relyx Ceramic Primer (3M ESPE), e posteriormente foram cimentados a blocos de resina composta Filtek Z100 (3M ESPE) com o cimento resinoso RelyX ARC (3M ESPE). Tais conjuntos foram seccionados, originando espécimes em forma de palito, com 1mm2 de área de secção transversal e submetidos ao ensaio de microtração. A análise estatística dos dados foi realizada por meio do teste de O teste utilizado foi...


Ceramic materials have been routinely used in restorative clinic. The adhesion capacity to adhesive cementation systems is a critical factor for clinical success. The main objective of the present study was to evaluate the adhesion properties to an adhesive cementation system of two experimental vitroceramic materials, a reinforced by lithium dissilicate (D) and another by lithium metasilicate (M) for dental application. For this purpose, the objective was to determine the influence of different surface treatments on bond strength to an adhesive cementation system through microtensile tests and characterize morphological changes resulting from the different surface treatments tested. Three surface treatments for each experimental material were selected: 1- blasting with Al2O3 particles (J), 2- etching with hydrofluoric acid 10% by 20 seconds (20) and 3- etching with hydrofluoric acid 10% for 60 seconds (60). A group of the commercial material, IPS e.max CAD (Ivoclar-Vivadent) was used as control, following the manufacturer's instructions for surface treatment. Morphological changes on the surface of the ceramics were analyzed by scanning electron microscopy (SEM) and demonstrated that experimental materials are acid sensitive and suffered topographical changes with the blasting. For the microtensile tests, the blocks of experimental and commercial ceramics had their surfaces conditioned and silanized with Silane agent Relyx Ceramic Primer (3M ESPE), and then they were cemented to resin composite blocks (Z100 Filtek blocks - 3M ESPE) with the resin cement, RelyX ARC (3 m ESPE). These sets were sectioned, resulting in stick-shaped specimens, with 1 mm2 cross sectional area and submitted to the microtensile tests. The test used was the analysis of variance to a criterion (One-Way ANOVA), adopting a significance level of α = 5%, the Bonferroni test was used for multiple comparisons, demonstrating that the D20 and M60 showed best results of...


Subject(s)
Ceramics/chemistry , Cementation/methods , Silicate Cement/chemistry , Lithium/chemistry , Glass/chemistry , Analysis of Variance , Materials Testing , Microscopy, Electron, Scanning , Reproducibility of Results , Surface Properties , Tensile Strength , Time Factors
7.
Full dent. sci ; 4(16): 599-609, out. 2013. ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-695734

ABSTRACT

Atualmente, o cuidado com a estética vem sendo valorizado de tal forma que, além de ser um referencial de saúde, ter um sorriso bonito significa também estar em harmonia consigo mesmo e ser uma pessoa bem sucedida. Dentro da Odontologia, a procura por um sorriso harmonioso e bonito vem crescendo a cada dia. Essa busca está diretamente relacionada a fatores sociais, culturais e psicológicos, que se alteram em função do tempo, dos valores de vida e da idade do indivíduo. Uma alternativa para a correção de imperfeições nos dentes é a utilização dos laminados cerâmicos que restabelecem a forma, cor, função e harmonia do sorriso, além de proporcionar longevidade do tratamento e satisfação plena do cliente. Os laminados cerâmicos são indicados para a correção de imperfeições dentárias, fraturas e dentições desgastadas pelas forças mastigatórias, substituindo estruturas defeituosas por um esmalte artificial integrado funcional e biologicamente aos tecidos dentários e periodontais. O estudo da resistência à fratura e à fadiga dos laminados cerâmicos fornece dados relativos ao reforço, estabilidade e a manutenção da estrutura dentária, prevenindo o preparo total da coroa dental. O presente relato apresenta, com base na literatura, uma reabilitação estética do sorriso usando laminados cerâmicos sem realização de preparo ou desgaste dos dentes. A comunicação harmônica entre o cirurgião dentista, TPD e os critérios científicos de planejamento são de fundamental importância para a obtenção resultados estéticos e funcionais com longevidade clínica.


Nowadays, the care with aesthetics aspects has been valued in such a way that, besides being an indicator of health, a beautiful smile is also associated to be in harmony with yourself and being a successful person. In Dentistry, the search for a beautiful and harmonious smile is increasing each day. This search is directly related to social, psychological and cultural factors that change with time, as with life values and age of the person. An alternative to correct dental imperfections is the use of laminate veneers that restore the shape, color, function and harmony of the smile, as well as provide longevity to the treatment and the complete satisfaction of the patient. The laminate veneers are indicated for the correction of dental imperfections, fractures and teeth worn by chewing forces, replacing defective structures by artificial enamel functionally and biologically integrated to the dental and periodontal tissues. The study on fracture and fatigue resistance of the laminate veneer provides data on the reinforcement, stability and maintenance of the dental structure, preventing the total preparation of the dental crown. This report is based on the literature and presents an aesthetical rehabilitation of the smile using laminate veneers without the realization of preparation or wear of the teeth. An effective communication between dentist surgeon, dental technician and the scientific criteria of planning are fundamental for obtaining aesthetic and functional results with clinical longevity.


Subject(s)
Humans , Female , Adult , Dental Veneers , Dental Prosthesis Design/methods , Dental Porcelain/therapeutic use , Tooth Preparation, Prosthodontic/methods , Tooth Preparation, Prosthodontic , Esthetics, Dental , Dental Impression Technique
8.
Rev. Odontol. Araçatuba (Impr.) ; 33(2): 19-25, jul.-dez. 2012. tab
Article in Portuguese | BBO - Dentistry | ID: biblio-856938

ABSTRACT

A demanda por restaurações estéticas tem resultado em um aumento do uso de cerâmicas dentais, constituindo a principal alternativa de material restaurador para a estrutura dental devido as suas propriedades favoráveis. Com isso, o objetivo desse trabalho será estudar, através de uma revisão de literatura, a evolução dos sistemas cerâmicos, envolvendo os diferentes tipos e propriedades, indicações e considerações clínicas. Em uma busca detalhada e avançada no banco de dados PubMed, foram encontrados 98 artigos utilizando os seguintes descritores: dental porcelain, dental ceramic e all-ceramic, de acordo com os critérios de inclusão e exclusão restaram apenas 35 artigos para a revisão. Diversos sistemas cerâmicos estão disponíveis no mercado, fazendo com que os profissionais da área protética necessitem de uma constante reciclagem acerca das suas propriedades e indicações, visto que bons resultados são devidos à seleção do melhor material para determinado caso em conjunto à habilidade do profissional


The demand for esthetic restorations has resulted in an increased use of dental ceramics and is the main alternative restorative material to tooth structure due to its favorable properties. Therefore, the aim of this work is to study the evolution of ceramic systems, involving different types and properties, indications, and clinical issues as aesthetic, cementing and longevity. In a detailed and advanced search in the database PubMed, 98 articles were found using the following key words: dental porcelain dental all-ceramic and ceramic according to the criteria for inclusion and exclusion left only 35 articles for review. Several ceramic systems are available in the market, making the prosthetic professionals need a constant recycling about their properties and directions, since good results are due to the selection of the best material for a particular case in all the skill of the practitioner


Subject(s)
Ceramics , Dental Porcelain , Dental Restoration, Permanent
9.
Full dent. sci ; 3(10): 198-205, jan.-mar. 2012. ilus, tab
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-642921

ABSTRACT

A Odontologia, de maneira geral, se vale gradualmentede processos manuais para a consecuçãode seus objetivos de tratamento e prevenção. A especialidadede prótese, em particular, dada à suapeculiaridade da necessidade de intervenção deum técnico de laboratório, acentua a fase artesanalda Odontologia. Não obstante, processos informatizadosde produção de restaurações protéticasvêm sendo incorporados, acompanhando o desenvolvimentode novas tecnologias. O processo deinformatização de produção de coroas, conhecidopela sigla CAD/CAM, está mudando não somentea tríade de relacionamento entre dentista/técnico/paciente, como também os materiais envolvidosnos tratamentos odontológicos. Neste contexto, énecessário conhecer profundamente as características,vantagens e desvantagens de cada sistema,para garantir longevidade estética e funcional dasrestaurações protéticas.


Dentistry, in general, relies heavily on manualprocesses to achieve its goals of treatmentand prevention. The specialty of prosthesis,in particular, given the peculiarity of the needfor intervention by a lab technician, emphasizesthe craft stage of dentistry. Nevertheless,computing processes of production ofprosthetic restorations have been incorporatedfollowing the development of newtechnologies. The computerized process ofproducing crowns, known by the acronymCAD / CAM, is changing not only the triadrelationship between dentist / technician /patient, but the materials involved in dentaltreatment. In this context, it is necessary toknow in depth the characteristics, advantagesand disadvantages of each system, toensure longevity of esthetic and functionalprosthetic restorations.


Subject(s)
Dental Prosthesis , Metal Ceramic Alloys , Software/trends , Technology, Dental/methods , Computer-Aided Design/instrumentation
10.
São Jose dos Campos; s.n; 2012. 82 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-867525

ABSTRACT

Este trabalho teve a finalidade de avaliar o efeito do tipo de substrato coronário (dentina e resina composta) na retenção de coroas cerâmicas de zircônia estabilizada por óxido de ítrio e comparar a retenção em função de diferentes protocolos. Para tanto, 144 molares recém-extraídos foram embutidos em resina acrílica, perpendicular ao seu longo eixo e preparados para coroa total, 72 permaneceram com o preparo em dentina e os demais, a parte coronáriapreparada foi removida e reconstruída em resina composta + pinos de fibracom dimensões idênticas à dentina preparada. Os preparos foram moldadoscom silicona de adição e dos troqueis foram obtidos 144 copings em YTZP, osquais apresentaram uma configuração especial para o ensaio de tração. Paraambos substratos, foi utilizado como grupo controle (n=12) um cimento à base de fosfato de zinco (sem condicionamento do substrato e da cerâmica). Os outros cimentos utilizados foram: um cimento à base de ionômero de vidro, um cimento resinoso da geração auto-condicionate (ambos sem condicionamento do substrato e da cerâmica) e um cimento Dual contendo monômeros fosfatados (MDP). Neste ultimo grupo, os remanescentes (dentina ou resina) foram condicionados com o adesivo correspondente do sistema e a cerâmica foi submetida a 3 tratamentos de superfície: álcool isopropílico, silicatização/silanização ou Vitrificação. Após 24h, todos os conjuntos foram submetidos a termocilagem (6000 ciclos) e incluídos em um dispositivo especial para o teste de tração em uma máquina de ensaio universal, para testar a retenção das infra-estruturas. Os modos de falha de todos os conjuntos foram analisados em estereomicroscópio e MEV para avaliar as possíveis causas de falha Os dados foram analisados estatisticamente. Osresultados mostraram na dentina, que o cimento à base de ionômero de vidroe o cimento à base de MDP, independente do tratamento de superfície, resultaram em maiores valores de retenção. Na resina, o cimento à base ...(AU)


The aim of this study was to evaluate the effect of the crown substratetype (dentine and composite resin) in the retention of stabilized zirconiaceramic crowns by yttrium oxide (YTZP) and to compare the retention function of four types of cements, four treatments of the substrate surface and three treatments of the ceramic surface. For this purpose, 144 freshly extracted molars were embedded in acrylic resin, perpendicular to the long axis and prepared for full crowns, 72 remained with the preparation in dentin and the other, the crown part was removed and reconstructed with composite resin + fiber pins with dimensions identical to the prepared dentin. The preparations were moulded with addition silicone and 144 YTZP copings were obtained, which presented a special setup for thetensile test. For the remainin, a phosphate-based cement zinc (unprimedsubstrate and ceramics) (n = 12) was used as the control group. The otherused cements were: a glass-ionomer based cement, a resin cement fromself-condicionating generation (unprimed substrate and ceramic) and aDual cement containing phosphate monomer. In the latter groups, theremaining (dentin or resin) was conditioned with the adhesive system and the corresponding ceramic was subjected to three surface treatments:isopropyl alcohol, silica coating / silanization or Overglaze. After 24 hours,all sets were submitted to thermocycling (6000 cycles) and included in aspecial device for the tensile test in a universal testing machine to test theretention of the infrastructure. The failure modes of all sets were analyzedunder a stereomicroscope and SEM to evaluate possible causes of failure.Data was analyzed statistically. The results showed that in dentin, theglass-ionomer based cement and the MDP-based cement, regardless thesurface treatment, resulted in higher retention values. In the resin, theMDP-based cement, associated with the...


Subject(s)
Materials Science , Tooth Crown , Ceramics/chemistry , Materials Testing , Zirconium
11.
São Jose dos Campos; s.n; 2012. 82 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: biblio-870177

ABSTRACT

Este trabalho teve a finalidade de avaliar o efeito do tipo de substrato coronário (dentina e resina composta) na retenção de coroas cerâmicas de zircônia estabilizada por óxido de ítrio e comparar a retenção em função de diferentes protocolos. Para tanto, 144 molares recém-extraídos foram embutidos em resina acrílica, perpendicular ao seu longo eixo e preparados para coroa total, 72 permaneceram com o preparo em dentina e os demais, a parte coronáriapreparada foi removida e reconstruída em resina composta + pinos de fibracom dimensões idênticas à dentina preparada. Os preparos foram moldadoscom silicona de adição e dos troqueis foram obtidos 144 copings em YTZP, osquais apresentaram uma configuração especial para o ensaio de tração. Paraambos substratos, foi utilizado como grupo controle (n=12) um cimento à base de fosfato de zinco (sem condicionamento do substrato e da cerâmica). Os outros cimentos utilizados foram: um cimento à base de ionômero de vidro, um cimento resinoso da geração auto-condicionate (ambos sem condicionamento do substrato e da cerâmica) e um cimento Dual contendo monômeros fosfatados (MDP). Neste ultimo grupo, os remanescentes (dentina ou resina) foram condicionados com o adesivo correspondente do sistema e a cerâmica foi submetida a 3 tratamentos de superfície: álcool isopropílico, silicatização/silanização ou Vitrificação. Após 24h, todos os conjuntos foram submetidos a termocilagem (6000 ciclos) e incluídos em um dispositivo especial para o teste de tração em uma máquina de ensaio universal, para testar a retenção das infra-estruturas. Os modos de falha de todos os conjuntos foram analisados em estereomicroscópio e MEV para avaliar as possíveis causas de falha Os dados foram analisados estatisticamente. Osresultados mostraram na dentina, que o cimento à base de ionômero de vidroe o cimento à base de MDP, independente do tratamento de superfície, resultaram em maiores valores de retenção. Na resina, o cimento à base...


The aim of this study was to evaluate the effect of the crown substratetype (dentine and composite resin) in the retention of stabilized zirconiaceramic crowns by yttrium oxide (YTZP) and to compare the retention function of four types of cements, four treatments of the substrate surface and three treatments of the ceramic surface. For this purpose, 144 freshly extracted molars were embedded in acrylic resin, perpendicular to the long axis and prepared for full crowns, 72 remained with the preparation in dentin and the other, the crown part was removed and reconstructed with composite resin + fiber pins with dimensions identical to the prepared dentin. The preparations were moulded with addition silicone and 144 YTZP copings were obtained, which presented a special setup for thetensile test. For the remainin, a phosphate-based cement zinc (unprimedsubstrate and ceramics) (n = 12) was used as the control group. The otherused cements were: a glass-ionomer based cement, a resin cement fromself-condicionating generation (unprimed substrate and ceramic) and aDual cement containing phosphate monomer. In the latter groups, theremaining (dentin or resin) was conditioned with the adhesive system and the corresponding ceramic was subjected to three surface treatments:isopropyl alcohol, silica coating / silanization or Overglaze. After 24 hours,all sets were submitted to thermocycling (6000 cycles) and included in aspecial device for the tensile test in a universal testing machine to test theretention of the infrastructure. The failure modes of all sets were analyzedunder a stereomicroscope and SEM to evaluate possible causes of failure.Data was analyzed statistically. The results showed that in dentin, theglass-ionomer based cement and the MDP-based cement, regardless thesurface treatment, resulted in higher retention values. In the resin, theMDP-based cement, associated with the...


Subject(s)
Tooth Crown , Materials Science , Ceramics/chemistry , Materials Testing , Zirconium
12.
Rev. dental press estét ; 7(1): 106-117, jan.-mar. 2010. graf, tab, ilus
Article in Portuguese | LILACS, BBO - Dentistry | ID: lil-557469

ABSTRACT

A fabricação de restaurações em cerâmica está se tornando cada vez mais popular, devido ao crescente avanço na qualidade desse material e na tecnologia empregada na confecção dessas restaurações. Essa evolução ocorreu graças, principalmente, à tecnologia CAD/CAM, que possibilitou o uso de cerâmicas de alta resistência na fabricação de próteses sem metal, com qualidade e uniformidade, padronizando os processos e reduzindo custos. O objetivo deste trabalho é realizar uma revisão da literatura dos sistemas cerâmicos existentes, bem como descrever os aspectos relacionados à estética, propriedades mecânicas, adaptação marginal, caracteristicas dos pônticos e conectores, e modo de cimentação, procurando mostrar as vantagens, desvantagens, indicações e contra-indicações da cada sistema.


Subject(s)
Cementation , Ceramics , Dental Prosthesis , Technology, Dental , Dental Marginal Adaptation , Dental Restoration, Permanent , Esthetics, Dental
13.
São Paulo; s.n; 2010. 170 p. ilus, tab, graf. (BR).
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: lil-578256

ABSTRACT

Objetivos: determinar a resistência à flexão em três pontos (f), módulo de Weibull (m), coeficiente de susceptibilidade ao crescimento subcrítico de trinca (n) e tenacidade à fratura (KIC) de três cerâmicas usadas para confecção de infraestrutura (IE) de próteses parciais fixas (PPFs) (YZ- zircônia tetragonal parcialmente estabilizada por óxido de ítrio; IZ- cerâmica a base de alumina infiltrada por vidro e reforçada com zircônia; AL alumina policristalina) e duas porcelanas (VM7 e VM9); avaliar o efeito da configuração (uma, duas ou três camadas) nos valores de f e modo de fratura dos corpos-de-prova (CP); avaliar a influência do material de IE, do tamanho dos conectores e da ciclagem mecânica (CM) na carga de fratura (CF) e distribuição de tensões de PPFs; relacionar o comportamento mecânico dos materiais cerâmicos testados na configuração de barra e de PPF. Material e Método: Foram produzidos três tipos de CP em forma de barra (2mm x 4mm x 16mm): monolítico, duas camadas e três camadas. As IE das PPFs foram confeccionadas utilizando o sistema CAD-CAM e recobertas com porcelana. Os ensaios de f foram realizados em saliva artificial a 37ºC. Os valores de m e n foram determinados pela análise de Weibull e ensaio de fadiga dinâmica, respectivamente. As PPFs foram carregadas no centro do pôntico até a fratura. Oito PPFs de cada grupo foram submetidas a CM com freqüência de 2 Hz e carga de 140 N durante 106 ciclos e, posteriormente, ensaiadas até a fratura. A distribuição de tensões nas PPFs foi avaliada com análise de elementos finitos (AEF). Os princípios da fractografia foram utilizados para determinar o padrão de fratura e os valores de KIC. Os dados de f e CF foram analisados estatisticamente com Kruskal-Wallis e Tukey (95%)...


Objectives: to determine the flexural strength (f), Weibull modulus (m), slow crack growth coefficient (n) and fracture toughness (KIC) of three ceramics used as framework materials for fixed partial dentures (FPDs) (YZ- yttria partially stabilized zirconia tetragonal polycrystals; IZ- alumina-based zirconia-reinforced glass infiltrated ceramic; AL alumina polycrystals) and two veneering porcelains (VM7 and VM9); to evaluate the effect of the specimen design (one, two or three layers) in the f and fracture mode; to evaluate the influence of the framework material, connector size and mechanical cycling (MC) in the fracture load (FL) and stress distribution of FPDs; to relate the mechanical behavior of the ceramic materials tested using bar-shaped specimens and FPDs. Materials and Methods: Bar-shaped specimens (2mm x 4mm x 16mm) were produced in three different designs: monolithic, bilayer and trilayer. FPD frameworks were built using CAD-CAM system and veneered with porcelain. Specimens were tested for three point bending in 37ºC artificial saliva. Weibull analysis and dynamic fatigue testing were used to determine m and n values, respectively. FPDs were tested with a load applied in the middle of the pontic. Eight FPDs of each group were subjected to MC using a frequency of 2Hz and load of 140N for 106 cycles and were subsequently loaded to failure. Stress distribution for FPDs was evaluated using finite element analysis (FEA). Fractography principles were used to determine the fracture mode and KIC values. f and FL data were analyzed using Kruskal-Wallis and Tukey (95%)...


Subject(s)
Ceramics , Denture, Partial, Fixed
14.
São Paulo; s.n; 2007. 194 p. ilus, tab, graf, ^eCD. (BR).
Thesis in Portuguese | LILACS, BBO - Dentistry | ID: lil-497714

ABSTRACT

O objetivo deste trabalho foi realizar a caracterização microestrutural e das propriedades mecânicas de diferentes cerâmicas odontológicas para entender sua influência nos parâmetros de crescimento de trinca subcrítico (SCG), n (coeficiente de susceptibilidade ao SCG) e ?f0 (parâmetro escalar), determinados por diferentes métodos. Cinco cerâmicas foram avaliadas: porcelanas VM7 (Vita) e D (d.Sign, Ivoclar), vitrocerâmicas E1 (IPS Empress, Ivoclar) e E2 (IPS Empress 2, Ivoclar) e compósito IC (In-Ceram Alumina, Vita). Espécimes em forma de disco (12 mm x 1 mm) foram confeccionados segundo as recomendações dos fabricantes. A caracterização microestrutural dos materiais foi realizada. A tenacidade à fratura (KIc) foi determinada pelo método da fratura por indentação (IF) e indentation strength. Os parâmetros de SCG foram determinados por fadiga dinâmica (com diferentes taxas de tensão constante), fadiga estática (com diferentes níveis de tensão constante) e fadiga por IF. Os resultados mostraram que todas as cerâmicas constituíram-se de fase vítrea e cristalina, com exceção da VM7, composta somente por fase amorfa. D e E1 apresentaram partículas de leucita, em frações volumétricas iguais a 0,16 e 0,29, sendo que E1 apresentou distribuição homogênea destes cristais, enquanto que D apresentou distribuição heterogênea, formando aglomerados. E2 apresentou cristais alongados de dissilicato de lítio, em fração volumétrica de 0,58, que apresentaram tendência de alinhamento com seu maior eixo alinhado perpendicularmente à direção de compactação, que variou angularmente a partir do ponto de injeção. O compósito IC apresentou-se constituído de cristais de alumina parcialmente sinterizados (65% em volume), infiltrados por vidro de baixa fusão. Independentemente do método, IC apresentou maior tenacidade (2,81 MPa.m1/2), seguido por E2 (1,81 MPa.m1/2) e E1 (0,96 MPa.m1/2) e, por último pelas porcelanas D (0,84 MPa.m1/2) e VM7 (0,67 MPa.m1/2)...


The objective of this study was to determine the mechanical properties and the microstructure of different dental ceramics in order to understand their influence on the slow crack growth (SCG) parameters, n (crack growth exponent) and ?f0, (scaling parameter), determined by different methods. The five ceramics tested were: porcelains VM7 (Vita) and D (d.Sign, Ivoclar), glass-ceramics E1 (IPS Empress, Ivoclar) e E2 (IPS Empress 2, Ivoclar) and composite IC (In-Ceram Alumina, Vita). Disc specimens (12 mm x 1 mm) were prepared according to manufacturers' instructions. The microstructure of the materials was carried out. The fracture toughness (KIc) was determined by means of the indentation fracture technique (IF) and indentation strength. The slow crack growth parameters were determined by dynamic fatigue test (constant stress rate), static fatigue test (constant stress) and the indentation fracture method. The results showed that all ceramic materials were composed by glassy matrix and crystalline phases, except for VM7 (vitreous porcelain). D and E1 presented leucite particles, in volume fractions of 0.16 and 0.29. For E1, the leucite crystals were homogeneously distributed in the glassy matrix, while in D, leucite formed agglomerates. E2 presented lithium dissilicate crystals (58% in volume) that presented an alignment tendency, with their major axis oriented perpendicularly to the pressing direction, which varied angularly from the injection point. IC presented alumina crystals (65% in volume) partially sintered, infiltrated by a lanthanum glass. Regardless of the method, the fracture toughness values were higher for IC (2.81 MPa.m1/2), followed by E2 (1.81 MPa.m1/2) and E1 (0.96 MPa.m1/2), and were lower for the porcelains D (0.84 MPa.m1/2) and VM7 (0.67 MPa.m1/2). Crack deflection was the main toughening mechanism observed for the ceramics containing crystalline phases. Regarding the dynamic fatigue test, the n values depended...


Subject(s)
Dental Materials , Metal Ceramic Alloys
SELECTION OF CITATIONS
SEARCH DETAIL
...