ABSTRACT
AIM: Our goal was to compare conformal 3D (C3D) radiotherapy (RT), modulated intensity RT (IMRT), and volumetric modulated arc therapy (VMAT) planning techniques in treating pituitary adenomas. BACKGROUND: RT is important for managing pituitary adenomas. Treatment planning advances allow for higher radiation dosing with less risk of affecting organs at risk (OAR). MATERIALS AND METHODS: We conducted a 5-year retrospective review of patients with pituitary adenoma treated with external beam radiation therapy (C3D with flattening filter, flattening filter-free [FFF], IMRT, and VMAT). We compared dose-volume histogram data. For OARs, we recorded D2%, maximum, and mean doses. For planning target volume (PTV), we registered V95%, V107%, D95%, D98%, D50%, D2%, minimum dose, conformity index (CI), and homogeneity index (HI). RESULTS: Fifty-eight patients with pituitary adenoma were included. Target-volume coverage was acceptable for all techniques. The HI values were 0.06, IMRT; 0.07, VMAT; 0.08, C3D; and 0.09, C3D FFF (pâ¯<â¯0.0001). VMAT and IMRT provided the best target volume conformity (CI, 0.64 and 0.74, respectively; pâ¯<â¯0.0001). VMAT yielded the lowest doses to the optic pathway, lens, and cochlea. The position of the neck in extreme flexion showed that it helps in planning mainly with VMAT by allowing only one arc to be used and achieving the desired conformity, decreasing the treatment time, while allowing greater protection to the organs of risk using C3D, C3DFFF. CONCLUSIONS: Our results confirmed that EBRT in pituitary adenomas using IMRT, VMAT, C3D, C3FFF provide adequate coverage to the target. VMAT with a single arc or incomplete arc had a better compliance with desired dosimetric goals, such as target coverage and normal structures dose constraints, as well as shorter treatment time. Neck extreme flexion may have benefits in treatment planning for better preservation of organs at risk. C3D with extreme neck flexion is an appropriate treatment option when other treatment techniques are not available.
ABSTRACT
AIM: The purpose of this study was to review genitourinary (GU) and gastrointestinal (GI) toxicity associated with high-dose radiotherapy (RT) delivered with 3-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) or volumetric arc therapy (VMAT) following radical prostatectomy (RP). BACKGROUND: RP is a therapeutic option for the management of prostate cancer (PrCa). When assessing postoperative RT techniques for PrCa, the published literature focuses on patients treated with 2-dimensional conventional methods without reflecting the implementation of 3D-CRT, IMRT, or VMAT. MATERIALS AND METHODS: A total of 83 patients were included in this analysis; 30 patients received 3D-CRT, and 53 patients received IMRT/VMAT. Acute and late symptoms of the GU and lower GI tract were retrospectively graded according to the Radiation Therapy Oncology Group and the European Organization for Research and Treatment of Cancer radiation toxicity grading systems. The relapse failure-free rate and overall survival were also evaluated. RESULTS: The rate of acute GU toxicity was 9.4% vs. 13.3% for the IMRT/VMAT and 3D-CRT groups (pâ¯=â¯0.583). The 5-year actuarial rates of late GI toxicity for IMRT/VMAT and 3D-CRT treatments were 1.9% and 6.7%, respectively. The rate of late GU toxicity for the IMRT/VMAT and 3D-CRT treatment groups was 7.5% and 16.6%, respectively (pâ¯=â¯0.199). We found no association between acute or late toxicity and the RT technique in univariate and multivariate analyses. CONCLUSION: Postprostatectomy IMRT/VMAT and 3D-CRT achieved similar morbidity and cancer control outcomes. The clinical benefit of highly conformal techniques in this setting is unclear although formal analysis is needed.