Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.627
Filter
1.
Cont Lens Anterior Eye ; : 102259, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38951051

ABSTRACT

PURPOSE: Daily disposable contact lenses offer numerous benefits in terms of ocular health and wearer convenience. The purpose of this work is to update earlier surveys by describing global trends in daily disposable lens fitting between 2000 and 2023. METHOD: An annual contact lens prescribing survey was sent to eye care practitioners in up to 71 countries between 2000 and 2023, inclusive. Data relating to 265,106 daily wear soft lens fits undertaken in 20 countries returning reliable longitudinal data were analysed in respect of daily disposable lens fitting. RESULTS: Overall, daily disposable lens prescribing increased over time, from 17.1 % of daily wear soft lens fits in 2000 to 46.7 % in 2023 (p < 0.0001). There were significant differences between countries in daily disposable lens prescribing (p < 0.0001), and between the percentage of males fitted with daily disposable lenses, as a proportion of all daily wear soft lenses (37.2 %), compared to females (35.2 %) (p < 0.0001). Daily disposable lens wearers are slightly younger at fitting than reusable soft lens wearers (31.0 vs 31.2 years, respectively) (p < 0.0001), although this difference is not clinically meaningful. Analysis of 50,240 daily wear soft lenses fitted recently (2019-2023) were found to be prescribed for the following replacement frequencies: daily - 47 %; monthly - 42 %; 1-2 weekly - 9 %; and ≥3 monthly - 2 %. CONCLUSION: There has been a substantial increase in daily disposable lens fitting throughout the first 24 years of this century. The gradual nature of this increase is commensurate with the staged introduction of daily disposable lens designs and expanded parameter ranges over the survey period.

3.
Cont Lens Anterior Eye ; : 102256, 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38965001

ABSTRACT

PURPOSE: To examine the safety and efficacy of soft multifocal contact lenses on slowing the rate of myopia progression. METHODS: A prospective, randomized, double-masked clinical trial was conducted including 115 children (55 boys and 60 girls) aged 8 to 15 years. Children were assigned to wear one of two daily disposable soft contact lens designs; a multifocal design (Pegavision) or a dual-focus design (MiSight, Coopervision) in both eyes for at least 8 h per day for one year. All contact lenses were replaced on a daily basis. Measurements were obtained using a logMAR vision meter, including objective refraction, handheld retinoscopy, high (96 %) and low (12 %) contrast sensitivity, and distance and near visual acuity. Axial length was measured every 6 months. RESULTS: After one year, the spherical equivalent refractive error and axial length of the experimental group (Pegavision) increased by -0.50 ± 0.48 D and 0.24 ± 0.16 mm, respectively, in the right eye and -0.47 ± 0.37 D and 0.23 ± 0.16 mm, respectively, in the left eye. The spherical equivalent refractive error and axial length of the control group (MiSight) increased by -0.48 ± 0.47 D and 0.22 ± 0.13 mm, respectively, in the right eye and by -0.50 ± 0.44 D and 0.23 ± 0.14 mm, respectively, in the left eye, with no significant differences observed between the two lens types. CONCLUSIONS: The one-year results from this clinical trial show that the multifocal soft contact lenses used in the experimental group have a similar myopia control efficacy with respect to spherical equivalent refraction and axial length elongation as a commercially available dual focus soft contact lens design.

4.
Heliyon ; 10(12): e32491, 2024 Jun 30.
Article in English | MEDLINE | ID: mdl-38952357

ABSTRACT

Purpose: To investigate the physical properties of commercially available multipurpose soft contact lens solutions in Ghana. Methods: pH (Kelilong ICL-099 pH meter, China), osmolality (OSMOMAT 3000, GONOTEC, Germany), surface tension (Sigma 700 Tensiometer, Sweden), and viscosity (CFOC-200 Viscometer, Cannon Company, USA) of various soft contact lens multipurpose solutions (MPS) were measured in triplicates at room temperature. Viscosity measurements were also taken at 34 °C ocular surface temperature. The solutions examined were Opti-Free Replenish (OFR), Trufresh (TF), Avizor (AV), Freshlook (FL), and Refresh (RF). Results: Several solutions were largely hypo-osmotic in the range of 108-231 mOsm/kg, the exception being Avizor, which had osmolality values that were closer to human tears (301 ± 0.58 mOsm/kg). The range of pH values of the solutions (6.33-8.24, mean (SD) = 7.53 ± 0.18) fell within the reported tolerable range for the ocular surface (6.20-9.00). Surface tension values ranged from 35.86 to 42.27 mNm with a mean of 38.49 ± 2.32 mNm. The average viscosity of most solutions at room temperature (25 °C) was 1.44 ± 0.49 cP with a range of 1.04-2.15 cP. Significantly lower values ranging from 0.79 to 1.58 cP were obtained at ocular surface temperature (34 °C), p = 0.0001). Conclusions: The physical properties of many of the solutions used as MPS in Ghana are markedly variable. Nevertheless, pH, surface tension, and viscosity fall within the acceptable limits of ocular physiological tolerance; except for osmolality, which majority were outside the reported tolerable range for the ocular surface. This information may partly explain the reason some patients exhibit strong preferences for certain care systems and should aid clinical decision-making when prescribing eye care systems to patients.

5.
J Ophthalmic Inflamm Infect ; 14(1): 26, 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38861099

ABSTRACT

BACKGROUND: Contamination in the contact lens training area could be due to bacteria, which can lead to the major consequence of ocular infections. We aimed to investigate the contamination caused by bacteria in the contact lens training area in private optical clinics of the Udupi district, India. METHODS: A cross-sectional study evaluated the swabs from the contact lens container, contact lens solution tip, washing area and lens fitting area for bacterial contamination. Twenty swabs collected from different areas of five optical clinics were inoculated in Brain heart infusion broth (BHIB). The broth was streaked in MacConkey and Blood agar and incubated at standard conditions for the growth of bacteria. All isolates were identified using conventional culture methods, and Gram staining was performed. RESULTS: Twenty samples (contact lens case, n = 5; contact lens solution tip, n = 5; washing area, n = 5; cleaning towel, n = 5) from private optical clinics were recruited for the study. Bacterial growth was indicated in which lactose fermentation was seen at (15%), non-lactose fermentation at (35%), and no bacterial growth at (50%) in MacConkey agar. Partial or alpha-hemolytic (α hemolysis) was seen in (5%), complete or beta-hemolytic (ß hemolysis) was seen in (40%), no hemolysis or gamma hemolysis (Ï« haemolysis), was seen in (30%), no growth was seen in (25%) on blood agar. Gram-positive cocci (45%), Gram-negative bacilli (20%), and no increase in (35%) were observed in MacConkey agar and Blood agar. Bacterial species were not identified in this study. CONCLUSION: Contamination was found in lenses, solution tips, washing areas, and cleaning towels which might lead to ocular infections. Perception should be given to those responsible for fitting lenses.

6.
Ocul Immunol Inflamm ; : 1-9, 2024 Jun 18.
Article in English | MEDLINE | ID: mdl-38889385

ABSTRACT

PURPOSE: To analyze changes in tear levels of inflammatory mediators in symptomatic contact lens (CL) wearers after refitting with daily disposable CLs and to identify potential biomarkers of success in CL discomfort (CLD) management. METHODS: Symptomatic CL wearers (CLDEQ-8 ≥ 12) were refitted (V1) with daily disposable CLs (Delefilcon A). After one month (V2), participants were classified into the post-fitting non-symptomatic (CLDEQ <12) and symptomatic (CLDEQ ≥12) groups. At each visit, the participants were clinically evaluated, tears were collected, and 20 inflammatory mediators and substance P (SP) were measured using multiplex immunobead analysis and ELISA, respectively. The detection rates and concentrations were compared between visits and groups, and logistic regression models were performed. RESULTS: Forty-three subjects (32 women/11 men; mean age: 23.2 ± 4.9 years) were enrolled. The IL-1ß and IL-9 detection rates were higher at V2 (p ≤ 0.044). The detection rates of IL-1ß, IL-9, MIP-1α/CCL3, and MMP-9 at V1 (p ≤ 0.045) and IL-17A at V2 (p ≤ 0.014) were higher in the post-fitting symptomatic group. The tear IL-9 concentration was increased at V2 (p = 0.018). The tear concentrations of fractalkine/CX3CL1, IL-2, IL-6, IL-10, MCP-3/CCL7, MIP-1ß, NGF, RANTES/CCL5, and TNF-α were higher in the post-fitting symptomatic group (p ≤ 0.044). Additionally, levels of fractalkine/CX3CL1, IL-2, IL-6, IL-10, RANTES/CCL5, and TNF-α at V1 were significantly associated with the post-fitting grouping (p ≤ 0.044). CONCLUSIONS: Low tear concentrations of specific inflammatory mediators may be used as a predictive biomarker of success for refitting symptomatic CL wearers with daily disposable CLs. However, complementary treatments might be required for symptomatic CL wearers with higher levels of these inflammatory molecules.

7.
Cont Lens Anterior Eye ; : 102252, 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38890070

ABSTRACT

PURPOSE: This study sought to assess contact lens solutions care practices, and their microbial contamination among contact lens wearers in Ghana and to profile their antibiotic susceptibility pattern. METHODS: The study employed a biphasic approach which involved a cross-sectional design that investigated participants' habits related to care for the solutions with a two-part questionnaire and a microbiological analysis of samples of contact lens care solutions of the participants for microbial contamination. A snowball sampling method provided access to 32 different contact lens wearers in four care facilities in Ghana. In most cases, the participants had no pre-existing familial relationship with each other or with the care facilities. RESULTS: Out of 32 samples of contact lens solutions, 30 were tested for microbial contamination. A total of 23 (76.67 %) samples of contact lens solution were found to be contaminated with Enterobacter sp. (34.80 %), Pseudomonas sp. (21.70 %), Bacilli sp. (21.70 %), Klebsiella sp. (17.20 %), and Escherichia coli (4.60 %). The duration of solution storage in the open bottle and nonadherence to manufacturer instructions for solution storage showed a statistically significant association with microbial contamination (p ≤ 0.05). CONCLUSION: Contact lens care solutions have been found to harbour multiple antibiotic-resistant bacteria that are potentially pathogenic to the corneal surface. The contamination is associated with some unhealthy solution-care practices among wearers.

8.
Sci Rep ; 14(1): 13860, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38879685

ABSTRACT

Contact lenses are widely used for vision correction and cosmetic purposes. Smart contact lenses offer further opportunities as functionalized non-invasive devices capable of simultaneous vision correction, real-time health monitoring and patient specific drug delivery. Herein, a low-cost vat photopolymerization technique is developed for directly 3D printing functionalized structures on commercially available contact lenses. The process enables controlled deposition of functionalized hydrogels, in customizable patterns, on the commercial contact lens surface with negligible optical losses. Multi-functional contact lenses can also be 3D printed with multiple materials deposited at different regions of the contact lens. Herein, the functionalities of colour blindness correction and real-time UV monitoring are demonstrated, by employing three suitable dyes incorporated into 2-hydroxyethyl methacrylate (HEMA) hydrogel structures printed on contact lenses. The results suggest that 3D printing can pave the way towards simple production of low-cost patient specific smart contact lenses.

9.
Br J Ophthalmol ; 2024 Jun 26.
Article in English | MEDLINE | ID: mdl-38925906

ABSTRACT

AIMS: To report an epidemiological update of bacterial keratitis (BK) in a tertiary ophthalmology centre over 20 months compared with a previous study on the same timeframe from 1998 to 1999. METHODS: 354 patients with BK documented by microbiological corneal scraping or resolutive under antibiotics treatment from January 2020 to September 2021 were analysed retrospectively. RESULTS: One or several risk factors were found in 95.2% of patients: contact lens wear (45.2%), ocular surface disease (25.0%), systemic disease (21.8%), ocular trauma (11.9%) and ocular surgery (8.8%). The positivity rate of corneal scrapings was 82.5%, with 18.2% polybacterial. One hundred seventy-five (59.9%) bacteria were Gram-negative, and 117 (40.1%) were Gram-positive. The most common bacteria were Pseudomonas aeruginosa (32.5%), Moraxella spp (18.1%) and Staphylococcus aureus (8.2%). Final visual acuity (logarithm of the minimum angle of resolution) was associated with age (r=+0.48; p=0.0001), infiltrate size (r=+0.32; p<0.0001), ocular surface disease (r=+0.13; p=0.03), ocular trauma (r=-0.14; p=0.02) and contact lens wear (r=-0.26; p<0.0001). Gram-negative bacteria were responsible for deeper (r=+0.18; p=0.004) and more extensive infiltrates (r=+0.18; p=0.004) in younger patients (r=-0.19; p=0.003). Compared with the previous period, the positivity rate of corneal scrapings and the proportion of Gram-negative bacteria, especially Moraxella spp, increased. All P. aeruginosa and Moraxella spp were sensitive to quinolones, and all S. aureus were sensitive to both quinolones and methicillin. CONCLUSION: Contact lens wear remained the leading risk factor. The bacteria distribution was reversed, with a predominance of Gram-negative bacteria and increased Moraxella spp.

10.
Int Ophthalmol ; 44(1): 239, 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38904856

ABSTRACT

BACKGROUND: This meta-analysis reviews the evidence for the risks and benefits associated with orthokeratology (OK) treatment compared with other methods of myopia control in children and adults. METHODS: A systematic search of Cochrane Central Register of Controlled Trials, Pubmed, Embase and Ovid was conducted from database inception to 22nd August 2021. Studies that reported on risks, visual and ocular biometric effects of OK in patients > 5 years of age with myopia (- 0.75 to - 6.00D) were included. Main outcomes are change in axial length and any adverse event. RESULTS: Fourty-five papers were included in this systematic review and meta-analysis. The quality of data was variable and of moderate certainty, and selection bias likely skewed the results towards a relative benefit for OK. The rate of axial elongation in children was lower for OK treatment compared to other treatment modalities at one year (MD - 0.16 mm, 95% CI - 0.25 to - 0.07). Rate of change in axial length in children rebounded after OK discontinuation compared to participants who continued treatment (MD 0.10 mm, 95% CI 0.06 to 0.14). Adults and children wearing OK were up to 3.79 times more likely to experience an adverse event when compared with conventional contact lenses (OR 3.79, 95% CI 1.24 to ll.), though this evidence base is underdeveloped and requires additional well-designed studies for substantial conclusions to be drawn. CONCLUSIONS: OK arrests myopia progression while in use, however, there remain unanswered questions about the optimal duration of treatment, discontinuation effects and long-term risk for adverse events.


Subject(s)
Myopia , Orthokeratologic Procedures , Refraction, Ocular , Humans , Orthokeratologic Procedures/methods , Orthokeratologic Procedures/adverse effects , Myopia/therapy , Myopia/physiopathology , Refraction, Ocular/physiology , Visual Acuity , Axial Length, Eye , Contact Lenses , Child , Risk Assessment/methods
11.
Diagn Microbiol Infect Dis ; 110(1): 116369, 2024 May 29.
Article in English | MEDLINE | ID: mdl-38909427

ABSTRACT

A 32-year-old contact lens-wearing man with recent travel history to the Caribbean was referred for a corneal infiltrate in the left eye that worsened following 1-week of steroid-antibiotic therapy. Corneal cultures were obtained and sent to our facility's clinical microbiology laboratory for analysis. Same-day in vivo confocal microscopy revealed fungal elements. Nucleic acid sequencing performed on the isolated determined it to be a member of the entomopathogenic genus Metarhizium. Over the course of 3 months, the patient's corneal infiltrate ultimately resolved following topical natamycin 5 % therapy. This is the first reported case to have originated in the Caribbean and to utilize in vivo confocal microscopy to aid diagnosis. Our case also supports previous reports of success with natamycin therapy in treatment of Metarhizium sp. keratitis.

12.
Genes (Basel) ; 15(6)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38927751

ABSTRACT

The identification of new biomarkers of ocular diseases is nowadays of outmost importance both for early diagnosis and treatment. Epigenetics is a rapidly growing emerging area of research and its involvement in the pathophysiology of ocular disease and regulatory mechanisms is of undisputable importance for diagnostic purposes. Environmental changes may impact the ocular surface, and the knowledge of induced epigenetic changes might help to elucidate the mechanisms of ocular surface disorders. In this pilot study, we investigated the impact of extensive contact lens (CL) wearing on human corneal epithelium epigenetics. We performed ex vivo analysis of the expression of the miR-320 and miR-423-5p involved in the processes of cellular apoptosis and chronic inflammation. The human corneal epithelium was harvested from healthy patients before the photorefractive keratectomy (PRK). The patients were divided into two age- and sex-matched groups accordingly to CL wearing history with no CL wearers used as a control. The epithelium was stored frozen in dry ice at -80 °C and forwarded for miRNA extraction; afterwards, miRNA levels were detected using real-time PCR. Both miRNAs were highly expressed in CL wearers (p < 0.001), suggesting epigenetic modifications occurring in chronic ocular surface stress. These preliminary results show the relationships between selected miRNA expression and the chronic ocular surface stress associated with extensive CL use. MicroRNAs might be considered as biomarkers for the diagnosis of ocular surface conditions and the impact of environmental factors on ocular surface epigenetic. Furthermore, they might be considered as new therapeutic targets in ocular surface diseases.


Subject(s)
Biomarkers , Contact Lenses , Epithelium, Corneal , MicroRNAs , Humans , MicroRNAs/genetics , Epithelium, Corneal/metabolism , Epithelium, Corneal/pathology , Female , Male , Adult , Biomarkers/metabolism , Pilot Projects , Epigenesis, Genetic , Gene Expression Regulation
13.
Cont Lens Anterior Eye ; : 102246, 2024 Jun 07.
Article in English | MEDLINE | ID: mdl-38851947

ABSTRACT

PURPOSE: Myopia (short-sightedness) is a growing vision problem worldwide. Currently atropine eye drops are used to control the progression of myopia but these suffer from potential lack of bioavailability and low ocular residence time. Commercially available myopia control contact lenses are also used to limit myopia progression, but neither atropine nor contact lenses individually completely stop progression. Development of myopia control contact lenses which could deliver therapeutic doses of atropine is thus desirable and may provide increased efficacy. This study was designed to explore the feasibility of attaching atropine to etafilcon A contact lenses through an esterification reaction. METHODS: Carboxylic acid groups on etafilcon A contact lenses were quantified using Toluidine Blue O. The carboxylic acid groups in etafilcon A contact lenses were activated using 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC-HCl) and N-hydroxysuccinimide (NHS) crosslinkers after which atropine was added to undergo potential binding via esterification. Atropine was released from lenses by alkaline hydrolysis. Reverse phase high performance liquid chromatography (HPLC) was used to detect and quantify the released atropine and its degradation products in solution. Contact lenses that had not been activated by EDC-NHS (controls) were also examined to determine the amount of atropine that could be absorbed rather than chemically bound to lenses. RESULTS: Each etafilcon A contact lens contained 741.1 ± 5.5 µg carboxylic acid groups which may be available for esterification. HPLC had a limit of detection for atropine of 0.38 µg/mL and for tropic acid, an atropine degradation product, of 0.80 µg/mL. The limits of quantification were 1.16 µg/mL for atropine and 2.41 µg/mL for tropic acid in NH4HCO3. The etafilcon A lenses adsorbed up to 7.69 µg atropine when incubated in a 5 mg/mL atropine solution for 24 h. However, there was no evidence that atropine could be chemically linked to the lenses, as washing in a high concentration of NaCl removed all the atropine from the contact lenses with no atropine being subsequently released from the lenses after incubating in 0.01 N NH4HCO3. CONCLUSIONS: Etafilcon A contact lenses contain free carboxylic acids which may be an appropriate option for attaching drugs such as atropine. Etafilcon A lenses adsorbed up to 7.69 µg atropine, which would be more than enough to deliver atropine to eyes to control myopia. However, atropine could not be chemically bound to the carboxylic acids of the etafilcon A lenses using this methodology.

14.
Cureus ; 16(5): e59431, 2024 May.
Article in English | MEDLINE | ID: mdl-38826919

ABSTRACT

Scleroderma is an autoimmune disease that affects connective tissue. Keratoconus (KC) is a rare ocular condition that may appear alongside scleroderma. Contact lenses are an essential visual aid for KC patients, especially in advanced cases. However, scleroderma patients may face difficulties using them due to finger-related disabilities. Corneal collagen cross-linking (CXL) is a crucial treatment used to prevent corneal thinning and visual deterioration in progressive KC. However, the potential trigger of corneal melt and delayed healing following CXL in KC patients with scleroderma is a matter of concern. We present a case of a patient with KC and scleroderma who underwent CXL without any complications.

15.
Cont Lens Anterior Eye ; : 102255, 2024 Jun 27.
Article in English | MEDLINE | ID: mdl-38942659

ABSTRACT

PURPOSE: Rigid contact lenses have an important role in contact lens practice. The purpose of this work is to update earlier surveys by describing global trends in rigid lens fitting between 2000-2023. METHOD: An annual contact lens prescribing survey was sent to eye care practitioners in up to 71 countries between 2000 and 2023. Data relating to 342,500 fits undertaken in 20 countries returning reliable longitudinal data were analysed in respect of rigid lens fitting, defined as the fitting of any design of a contact lens manufactured in a rigid material. RESULTS: Overall, rigid lens prescribing increased slightly over time, from 14.2 % of lens fits in 2000 to 15.2 % in 2023 (p < 0.0001). However, post-hoc analysis shows that the change over time is best described as a decline between 2000 and 2012, followed by a steady increase subsequently. There were significant differences in rigid lens prescribing between countries (p < 0.0001). The difference between the percentage of males fitted with rigid lenses, as a proportion of all contact lenses (12.7 %), and females (12.0 %) is significant (p < 0.0001), although not clinically meaningful. Rigid lens wearers are older at fitting than soft lens wearers (38.7 vs 31.3 years, respectively) (p < 0.0001). Analysis of 5,994 rigid lens fits prescribed currently (2019-2023) were categorised as: corneal sphere - 30 %; scleral and corneo-scleral - 28 %; corneal myopia control/orthokeratology - 21 %; and corneal complex (including toric, multifocal and monovision) - 16 %. CONCLUSION: There has been a slight increase in rigid lens fitting during the second decade of this century. This increase is apparently due to a 'repurposing' of rigid lenses, with the growth of scleral/corneo-scleral and myopia control/orthokeratology lens fits essentially replacing conventional spherical corneal lens fits.

16.
Microorganisms ; 12(6)2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38930596

ABSTRACT

Ophthalmologists' diagnostic and treatment competence in Acanthamoeba keratitis varies widely. This investigator-initiated, retrospective, single-center chart review examined the electronic patient files regarding PCR-positive Acanthamoeba keratitis. We included corneal and contact lens assessments. We further reviewed the patient's medical history, corneal scraping results regarding viral or fungal co-infections, and the duration from symptom onset to final diagnosis. We identified 59 eyes of 52 patients from February 2010 to February 2023, with 31 of 52 (59.6%) being female patients. The median (IQR, range) patient age was 33 (25.3 to 45.5 [13 to 90]) years, and the mean (SD, range) time to diagnosis after symptom onset was 18 (10.5 to 35 [3 to 70]) days. Overall, 7 of 52 (7.7%) patients displayed a bilateral Acanthamoeba infection, and 48 (92.3%) used contact lenses at symptom onset. Regarding other microbiological co-infections, we found virologic PCR testing in 45 of 52 (86.5%) patients, with 3 (6.7%) positive corneal scrapings. Fungal cultures were performed in 49 of 52 (94.2%) patients, with 5 (10.2%) positive corneal scrapings. The medical treatment success rate was 45/46 (97.8%). This study raises awareness of patient education in contact lens handling and screens for further microbial co-infections in suspected Acanthamoeba cases.

17.
Cureus ; 16(4): e58223, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38745798

ABSTRACT

INTRODUCTION: Evaluation of anterior segment parameters is crucial in ophthalmic procedures such as intraocular surgeries and contact lens fitting. However, the use of tropicamide in diabetic patients presents challenges due to its potential impact on biometric measurements. This study aims to investigate and compare the effects of 0.5% and 1% tropicamide on anterior segment parameters in diabetic patients. METHODS: This double-masked randomized clinical trial enrolled 98 patients with diabetes mellitus. Participants were randomly assigned to receive either 0.5% or 1% tropicamide. Anterior segment parameters were measured using Pentacam HR (Oculus Optikgeräte GmbH, Wetzlar, Germany) before and 30 minutes after tropicamide administration. Parameters included anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), keratometry, central corneal thickness (CCT), white-to-white distance (WTW), and pupillary diameter (PD). RESULTS: Both concentrations of 0.5% and 1% tropicamide induced significant changes in anterior segment parameters. There was a notable increase in PD (2.99 ± 0.62, 3.11 ± 0.55, respectively, both P-values < 0.001), ACD (both 0.10 ± 0.05, both P-values < 0.001), ACV (16.69 ± 9.56, 17.51 ± 9.26, respectively, both P-values < 0.001), and WTW (0.06 ± 0.14, 0.03 ± 0.30, respectively, both P-values < 0.001), along with a decrease in ACA (-3.50 ± 10.65, -3.30 ± 6.87, P-value < 0.001 and P-value=0.001, respectively), and CCT (-6.10 ± 8.06, -6.39 ± 9.97, respectively, both P-values < 0.001) post-dilation. However, no significant changes were observed in keratometry (front Km (-0.03 ± 0.19, -0.04 ± 0.21, respectively), back Km (0.01 ± 0.05, 0.004 ± 0.05, respectively), P-values> 0.05). CONCLUSION: Both concentrations of tropicamide exhibited comparable effects on anterior segment parameters in diabetic patients. These post-dilation changes should be considered for accurate intraocular lens power calculation and decision-making for cataract, phakic intraocular lens, and refractive surgeries.

18.
Cureus ; 16(4): e58216, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38745816

ABSTRACT

INTRODUCTION: Given the growing popularity of contact lenses among female students in Saudi Arabia for various reasons including vision correction as well as aesthetic and therapeutic purposes, it is essential to understand the knowledge about them, their uses, and how to handle them, given their significance in healthcare. METHODS: A cross-sectional study design was utilized in this research, employing data from a sample of 413 female students at the University of Bisha. The participants completed a self-administered questionnaire and were ensured anonymity. RESULTS: The study results showed that 52.9% (n=218) had a good knowledge level while 47.1% (n=195) had poor knowledge about contact lenses use. The results established a statistically significant association between region, faculty, and study year (p<0.005) with p-values of 0.002, 0.001, and 0.005, respectively, and level of knowledge about contact lens use. There was no statistically significant association between the age of the participants and the level of knowledge about contact lens use. CONCLUSION: Although there was a generally good level of awareness about contact lens use among female students, there is still insufficiency in knowledge with regard to particular aspects such as cleaning the contact lenses and contact lens cover. The study finds the need for more ocular educational sessions with ophthalmologists to increase awareness about contact lenses.

19.
Clin Ophthalmol ; 18: 1329-1339, 2024.
Article in English | MEDLINE | ID: mdl-38765455

ABSTRACT

Purpose: To assess changes in symptoms and ocular surface signs following a bilateral sutureless treatment of dehydrated amniotic membrane (dAM) under a specialised bandage contact lens (sBCL) in patients with moderate-to-severe dry eye disease (DED). Patients and Methods: In this prospective pre-post interventional study, 35 patients diagnosed with moderate-to-severe DED, with an Ocular Surface Disease Index (OSDI) score >30 on current treatment, were enrolled. Assessments were conducted at baseline (day -30), after 30 days run-in with no additional treatment (day 0 - control), and 30 days post sBCL+dAM treatment (day 30 - treatment). Intervention involved two successive bilateral 4-5 day sutureless applications of dAM (17mm diameter, with a 6 mm central aperture, Omnigen® VIEW) under an 18mm sBCL (OmniLenz®). Symptomatology and ocular signs were measured using OSDI, Dry Eye Questionnaire-5 (DEQ-5), Symptom Assessment iN Dry Eye (SANDE), and other ocular surface health indicators including non-invasive breakup time, corneal and conjunctival staining, and lid wiper epitheliopathy length and width (LWE). Results: While symptomatology remained stable during the 30-day no-treatment run-in, 1-month post-dAM treatment, there was a significant reduction in OSDI scores (from 55.8 to 32.3, p<0.001), DEQ-5 (from 14.6 to 10.0, p<0.001), SANDE frequency (from 65.2 to 43.6, p<0.001), and SANDE severity (from 59.8 to 41.1, p<0.001). Additionally, there was a notable decrease in the width of LWE staining, from grade 2 (50-75% of the lid wiper) to grade 1 (25-50% of the lid wiper) (p=0.011). Conclusion: A bilateral 8-10-day treatment duration with dAM applied with sBCL demonstrated a 31 to 42% improvement in symptomatology and a decrease in ocular surface signs of mechanical stress. This innovative bilateral treatment approach offers a promising treatment modality for patients with refractory moderate-to-severe DED.

20.
Curr Eye Res ; : 1-9, 2024 May 30.
Article in English | MEDLINE | ID: mdl-38813807

ABSTRACT

PURPOSE: This study compared the anti-pseudomonal effects between nephrite-impregnated contact lenses (CLs) and conventional and cosmetic CLs. METHODS: After inoculation with Pseudomonas aeruginosa (P.aeruginosa), we counted the number of bacteria on the CL surface and observed each surface using atomic force microscopy (AFM) and scanning electron microscopy (SEM). To estimate potential harm of nephrite-impregnated CLs, we conducted a safety test using a rabbit model, treated with all CL types. RESULTS: Both conventional and cosmetic CLs (n = 258 ± 2.9 × 104, 368 ± 2.2 × 104) showed significantly decreased number of attached bacteria when compared with those without nephrite impregnation (n = 134 ± 0.8 × 104, 238 ± 2.5 × 104, p < 0.0001, respectively). AFM and SEM revealed that P. aeruginosa was less attached to the nephrite-impregnated CLs than to the conventional and cosmetic CLs, although those with nephrite impregnation had rougher surface. In the safety test, there were no significant differences in the findings between four groups, and the clarity and stability of all corneas were preserved. CONCLUSIONS: Nephrite may be used as a next-generation substance to reduce infectious keratitis caused by P. aeruginosa when added to CLs.

SELECTION OF CITATIONS
SEARCH DETAIL
...