Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 150
Filter
1.
Magn Reson Med Sci ; 2024 Sep 05.
Article in English | MEDLINE | ID: mdl-39231732

ABSTRACT

PURPOSE: Fresh blood imaging (FBI) utilizes physiological blood signal differences between diastole and systole, causing a long acquisition time. The purpose of this study is to develop a fast FBI technique using a centric ky - kz k-space trajectory (cFBI) and an exponential refocusing flip angle (eFA) scheme with fast longitudinal restoration. METHODS: This study was performed on 8 healthy subjects and 2 patients (peripheral artery disease and vascular disease) with informed consent, using a clinical 3-Tesla MRI scanner. A numeric simulation using extended phase graph (EPG) and phantom studies of eFA were carried out to investigate the restoration of longitudinal signal by lowering refocusing flip angles in later echoes. cFBI was then acquired on healthy subjects at the popliteal artery station to assess the effect of varying high/low flip ratios on the longitudinal restoration effects. In addition, trigger-delays of cFBI were optimized owing to the long acquisition window in zigzag centric ky - kz k-space trajectory. After optimizations, cFBI images were compared against standard FBI (sFBI) images in terms of scan time, motion artifacts, Nyquist N/2 artifacts, blurring, and overall image quality. We also performed two-way repeated measures analysis of variance. RESULTS: cFBI with eFA achieved nearly a 50% scan time reduction compared to sFBI. The high/low flip angle of 180/2 degrees with lower refocusing pulses shows fast longitudinal restoration with the highest blood signals, yet also more sensitive to the background signals. Overall, 180/30 degrees images show reasonable blood signal recovery while minimizing the background signal artifacts. After the trigger delay optimization, maximum intensity projection image of cFBI after systole-diastole subtraction demonstrates less motion and N/2 artifacts than that of sFBI. CONCLUSION: Together with eFA for fast longitudinal signal restoration, the proposed cFBI technique achieved a 2-fold reduction in scan time and improved image quality without major artifacts.

2.
J Soc Cardiovasc Angiogr Interv ; 3(1): 101174, 2024 Jan.
Article in English | MEDLINE | ID: mdl-39131972

ABSTRACT

The lymphatic system plays a central role in some of the most devastating complications associated with congenital heart defects. Diseases like protein-losing enteropathy, plastic bronchitis, postoperative chylothorax, and chylous ascites are now proven to be lymphatic in origin. Novel imaging modalities, most notably, noncontrast magnetic resonance lymphangiography and dynamic contrast-enhanced magnetic resonance lymphangiography, can now depict lymphatic anatomy and function in all major lymphatic compartments and are essential for modern therapy planning. Based on the new pathophysiologic understanding of lymphatic flow disorders, innovative minimally invasive procedures have been invented during the last few years with promising results. Abnormal lymphatic flow can now be redirected with catheter-based interventions like thoracic duct embolization, selective lymphatic duct embolization, and liver lymphatic embolization. Lymphatic drainage can be improved through surgical or interventional techniques such as thoracic duct decompression or lympho-venous anastomosis.

3.
Comput Biol Med ; 179: 108836, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38968764

ABSTRACT

Automated identification of cardiac vortices is a formidable task due to the complex nature of blood flow within the heart chambers. This study proposes a novel approach that algorithmically characterizes the identification criteria of these cardiac vortices based on Lagrangian Averaged Vorticity Deviation (LAVD). For this purpose, the Recurrent All-Pairs Field Transforms (RAFT) is employed to assess the optical flow over the Phase Contrast Magnetic Resonance Imaging (PC-MRI), and to construct a continuous blood flow velocity field and reduce errors that arise from the integral process of LAVD. Additionally, Generalized Hough Transform (GHT) is applied for automated depiction of the structure of cardiac vortices. The effectiveness of this method is demonstrated and validated by the computation of the acquired cardiac flow data. The results of this comprehensive visual and analytical study show that the evolution of cardiac vortices can be effectively described and displayed, and the RAFT framework for optical flow can synthesize the in-between PC-MRIs with high accuracy. This allows cardiologists to acquire a deeper understanding of intracardiac hemodynamics and its impact on cardiac functional performance.


Subject(s)
Algorithms , Humans , Blood Flow Velocity/physiology , Magnetic Resonance Imaging/methods , Models, Cardiovascular , Heart/physiology , Heart/diagnostic imaging , Image Processing, Computer-Assisted/methods
4.
Indian J Nucl Med ; 39(2): 87-97, 2024.
Article in English | MEDLINE | ID: mdl-38989312

ABSTRACT

Background and Purpose: Follow-up imaging of gliomas is crucial to look for residual or recurrence and to differentiate them from nontumoral tissue. Positron emission tomography (PET)-magnetic resonance imaging (MRI) is the problem-solving tool in such cases. We investigated the role of dual point contrast (DPC)-enhanced MRI to discriminate tumoral from the nontumoral tissue compared to PET-MRI taken as the gold standard. Materials and Methods: The institutional ethics committee approved the study, and consent was obtained from all the patients included in the study. We prospectively did immediate and 75-min delayed contrast MRI in glioma cases who came for follow-up as a part of PET-MRI study in our institute. Subtracted images were obtained using immediate and 75-min delayed contrast images. Color-coded subtracted images were compared with PET-MRI images. 75-min delayed contrast MRI and diffusion-weighted imaging (DWI) images with Gray Scale inversion were compared with PET attenuation-corrected images. Results: We included 23 PET MRI cases done with different radiotracers in our study. Overall, we found PET-DPC correlation in (20/20 ~ 100%) cases of enhancing tumors. In two cases (DOPA and fluorodeoxyglucose), since they were nonenhancing low-grade gliomas and the other one was melanoma with intrinsic T1 hyperintensity and the DPC technique could not be used. DWI-PET correlated in 17/19 (~89.4%) cases, and perfusion-weighted imaging (PWI)-PET dynamic susceptibility contrast (DSC)/ASL correlated in 14/18 (~77.7%) cases after cases with hemorrhage were excluded. Conclusion: DPC MRI showed a good correlation with PET MRI in discriminating tumoral from the nontumoral tissue. DPC MRI can act as a potential alternative to PET MRI in peripheral hospitals where PET is not available. However, the DPC technique is limited in low-grade nonenhancing gliomas.

5.
Magn Reson Med Sci ; 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38556273

ABSTRACT

PURPOSE: Prolonged scanning of time-resolved 3D phase-contrast MRI (4D flow MRI) limits its routine use in clinical practice. An echo-planar imaging (EPI)-based sequence and compressed sensing can reduce the scan duration. We aimed to determine the impact of EPI for 4D flow MRI on the scan duration, image quality, and quantitative flow metrics. METHODS: This was a prospective study of 15 healthy volunteers (all male, mean age 33 ± 5 years). Conventional sensitivity encoding (SENSE), EPI with SENSE (EPI), and compressed SENSE (CS) (reduction factors: 6 and 12, respectively) were scanned.Scan duration, qualitative indexes of image quality, and quantitative flow parameters of net flow volume, maximum flow velocity, wall shear stress (WSS), and energy loss (EL) in the ascending aorta were assessed. Two-dimensional phase-contrast cine MRI (2D-PC) was considered the gold standard of net flow volume and maximum flow velocity. RESULTS: Compared to SENSE, EPI and CS12 shortened scan durations by 71% and 73% (EPI, 4 min 39 sec; CS6, 7 min 29 sec; CS12, 4 min 14 sec; and SENSE, 15 min 51 sec). Visual image quality was significantly better for EPI than for SENSE and CS (P < 0.001). The net flow volumes obtained with SENSE, EPI, and CS12 and those obtained with 2D-PC were correlated well (r = 0.950, 0.871, and 0.850, respectively). However, the maximum velocity obtained with EPI was significantly underestimated (P < 0.010). The average WSS was significantly higher with EPI than with SENSE, CS6, and CS12 (P < 0.001, P = 0.040, and P = 0.012, respectively). The EL was significantly lower with EPI than with CS6 and CS12 (P = 0.002 and P = 0.007, respectively). CONCLUSION: EPI reduced the scan duration, improved visual image quality, and was associated with more accurate net flow volume than CS. However, the flow velocity, WSS, and EL values obtained with EPI and other sequences may not be directly comparable.

7.
World Neurosurg ; 181: e18-e28, 2024 Jan.
Article in English | MEDLINE | ID: mdl-36791880

ABSTRACT

OBJECTIVE: We assessed the feasibility of using compressed sensing accelerated, low-velocity encoded, isotropic resolution phase contrast (CLIP) magnetic resonance angiography (MRA) for avascular trajectory planning of stereoelectroencephalography. METHODS: Ten healthy subjects (1 woman and 9 men; age, 33.6 ± 9.0 years) and 20 consecutive patients (12 female patients; age, 22 ± 13.6 years) were enrolled in the present study. The healthy subjects underwent CLIP-MRA, and 3 other phase contrast MRA protocols with conventional parallel imaging (PI) acceleration, including low resolution with twofold PI (PI2), high resolution (HR) with fivefold PI (PI5), and HR-PI2. The patients underwent CLIP-MRA and computed tomography angiography (CTA). The image qualities were evaluated. The numbers and locations of trajectory-vessel conflict detected using CLIP-MRA were noted. RESULTS: With similar scan durations, CLIP-MRA achieved higher spatial resolution compared with low resolution with PI2 and detected significantly more branches compared with HR-PI5. With the same spatial resolution, the signal/noise and contrast/noise ratios of CLIP-MRA were higher than those with HR-PI2 with a shorter scan duration. For the 12 adult patients (10 female patients; 28.8 ± 12.7 years), CLIP-MRA had better signal/noise and contrast/noise ratios than CTA. The trajectory had required modification for 14 of the 20 patients (70%), with a proportion of trajectory modification of 10.7% (23 of 215 electrodes). The middle meningeal artery, cortical vessel, and skull vessel were the main vessels with conflict (n = 11, n = 7, and n = 5, respectively). CONCLUSIONS: In the present study, CLIP-MRA provided a clear cortical vascular display noninvasively without intravascular contrast and radiation. The middle meningeal artery and diploic and emissary veins were the main conflict vessels and could be clearly displayed using CLIP-MRA but not CTA.


Subject(s)
Magnetic Resonance Angiography , Tomography, X-Ray Computed , Adult , Male , Humans , Female , Young Adult , Child , Adolescent , Magnetic Resonance Angiography/methods , Computed Tomography Angiography , Contrast Media
8.
Pediatr Int ; 65(1): e15704, 2023.
Article in English | MEDLINE | ID: mdl-37991179

ABSTRACT

BACKGROUND: Kawasaki disease (KD) is a systemic vasculitis; systemic arteries other than the coronary arteries should therefore also be evaluated. This study investigated the feasibility of evaluating coronary aneurysms, systemic artery aneurysms (SAAs), and cerebrovascular diseases in patients with KD using non-contrast magnetic resonance angiography (NC-MRA). METHODS: Coronary artery protocols, including coronary magnetic resonance angiography (MRA) and vessel wall imaging, were performed in 57 examinations of 28 patients. Systemic artery protocol, including SAA scans and head MRA, along with coronary artery protocol, were performed in 42 examinations of 42 patients. The image quality of the SAAs was evaluated on a 4-point scale. Examination time and sedation dosage were compared between the protocols. The presence of SAAs and cerebrovascular disease was also evaluated. RESULTS: The image quality score of SAAs was 4 (interquartile range [IQR]: 4-4) for the aorta, 4 (IQR: 3-4) for the subclavian artery, 4 (IQR: 3-4) for the renal artery, and 3 (IQR: 3-4) for the iliac artery. No differences were found between examination time (47.0 [IQR: 43.0-61.0] min vs. 51.0 [IQR: 45.0-60.0] min, p = 0.48) and sedative dose (4.63 [IQR: 3.93-5.79] mg/kg vs. 4.21 [IQR: 3.56-5.71] mg/kg, p = 0.37) between the protocols. Systemic artery protocol detected SAAs in three patients (7.1%), and cerebrovascular disease was not detected. CONCLUSIONS: Evaluating the coronary and systemic arteries in patients with KD using NC-MRA on a single examination was possible without compromising examination time or sedation dose. The systemic artery protocol was useful in finding SAAs.


Subject(s)
Coronary Aneurysm , Mucocutaneous Lymph Node Syndrome , Humans , Magnetic Resonance Angiography/methods , Mucocutaneous Lymph Node Syndrome/diagnosis , Mucocutaneous Lymph Node Syndrome/diagnostic imaging , Renal Artery/pathology , Coronary Aneurysm/diagnosis , Iliac Artery , Contrast Media
9.
Radiol Med ; 128(10): 1225-1235, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37620674

ABSTRACT

PURPOSE: Four-dimensional time-resolved phase-contrast cardiovascular magnetic resonance imaging (4D flow MRI) enables blood flow quantification in multiple vessels, which is crucial for patients with congenital heart disease (CHD). We investigated net flow volumes in the ascending aorta and pulmonary arteries by four different postprocessing software packages for 4D flow MRI in comparison with 2D cine phase-contrast measurements (2D PC). MATERIAL AND METHODS: 4D flow and 2D PC datasets of 47 patients with biventricular CHD (median age 16, range 0.6-52 years) were acquired at 1.5 T. Net flow volumes in the ascending aorta, the main, right, and left pulmonary arteries were measured using four different postprocessing software applications and compared to offset-corrected 2D PC data. Reliability of 4D flow postprocessing software was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Linear regression of internal flow controls was calculated. Interobserver reproducibility was evaluated in 25 patients. RESULTS: Correlation and agreement of flow volumes were very good for all software compared to 2D PC (ICC ≥ 0.94; bias ≤ 5%). Internal controls were excellent for 2D PC (r ≥ 0.95, p < 0.001) and 4D flow (r ≥ 0.94, p < 0.001) without significant difference of correlation coefficients between methods. Interobserver reliability was good for all vendors (ICC ≥ 0.94, agreement bias < 8%). CONCLUSION: Haemodynamic information from 4D flow in the large thoracic arteries assessed by four commercially available postprocessing applications matches routinely performed 2D PC values. Therefore, we consider 4D flow MRI-derived data ready for clinical use in patients with CHD.


Subject(s)
Heart Defects, Congenital , Magnetic Resonance Imaging , Humans , Infant , Child, Preschool , Child , Adolescent , Young Adult , Adult , Middle Aged , Reproducibility of Results , Blood Flow Velocity/physiology , Aorta/diagnostic imaging , Software , Imaging, Three-Dimensional/methods
10.
Int J Cardiol ; 390: 131203, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37480997

ABSTRACT

OBJECTIVE: To compare the measurement of aortic diameters using a novel flow-independent MR-Angiography (3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT)) and transthoracic echocardiography (TTE) in Marfan syndrome (MFS) patients. MATERIAL AND METHODS: This retrospective, single-center analysis included 46 examinations of 32 MFS patients (mean age 37.5 ± 11.3 years, 17 women, no prior aortic surgery) who received TTE and 3D modified REACT (ECG- and respiratory-triggering, Compressed SENSE factor 9 for acceleration of image acquisition) of the thoracic aorta. Aortic diameters (sinus of Valsalva (SV), sinotubular junction (STJ), and ascending aorta (AoA)) were independently measured by two cardiologists in TTE (leading-edge) and two radiologists in modified REACT (inner-edge, using multiplanar reconstruction). Intraclass correlation coefficient, Bland-Altman analyses, and Pearson's correlation (r) were used to assess agreement between observers and methods. RESULTS: Interobserver correlation at the SV, STJ, and AoA were excellent for both, TTE (ICC = 0.95-0.98) and modified REACT (ICC = 0.99-1.00). There was no significant difference between TTE and modified REACT for diameters measured at the SV (39.24 ± 3.24 mm vs. 39.63 ± 3.76 mm; p = 0.26; r = 0.78) and the STJ (35.16 ± 4.47 mm vs. 35.37 ± 4.74 mm; p = 0.552; r = 0.87). AoA diameters determined by TTE were larger than in modified REACT (34.29 ± 5.31 mm vs. 30.65 ± 5.64 mm; p < 0.01; r = 0.74). The mean scan time of modified REACT was 05:06 min ± 02:47 min, depending on the patient's breathing frequency and heart rate. CONCLUSIONS: Both TTE and modified REACT showed a strong correlation for all aortic levels; however, at the AoA, diameters were larger using TTE, mostly due to the limited field of view of the latter with measurements being closer to the aortic valve. Given the excellent interobserver correlation and the strong agreement with TTE, modified REACT represents an attractive method to depict the thoracic aorta in MFS patients.


Subject(s)
Aorta, Thoracic , Marfan Syndrome , Humans , Female , Adult , Middle Aged , Aorta, Thoracic/diagnostic imaging , Marfan Syndrome/diagnostic imaging , Retrospective Studies , Echocardiography/methods , Magnetic Resonance Angiography/methods , Reproducibility of Results
11.
J Cardiovasc Magn Reson ; 25(1): 40, 2023 07 20.
Article in English | MEDLINE | ID: mdl-37474977

ABSTRACT

Hemodynamic assessment is an integral part of the diagnosis and management of cardiovascular disease. Four-dimensional cardiovascular magnetic resonance flow imaging (4D Flow CMR) allows comprehensive and accurate assessment of flow in a single acquisition. This consensus paper is an update from the 2015 '4D Flow CMR Consensus Statement'. We elaborate on 4D Flow CMR sequence options and imaging considerations. The document aims to assist centers starting out with 4D Flow CMR of the heart and great vessels with advice on acquisition parameters, post-processing workflows and integration into clinical practice. Furthermore, we define minimum quality assurance and validation standards for clinical centers. We also address the challenges faced in quality assurance and validation in the research setting. We also include a checklist for recommended publication standards, specifically for 4D Flow CMR. Finally, we discuss the current limitations and the future of 4D Flow CMR. This updated consensus paper will further facilitate widespread adoption of 4D Flow CMR in the clinical workflow across the globe and aid consistently high-quality publication standards.


Subject(s)
Cardiovascular System , Humans , Blood Flow Velocity , Predictive Value of Tests , Heart , Magnetic Resonance Imaging , Magnetic Resonance Spectroscopy
12.
J Med Life ; 16(3): 412-418, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37168307

ABSTRACT

Magnetic resonance imaging (MRI) is essential for assessing shoulder conditions. This study aimed to evaluate current shoulder MRI practices in Jordan, including technical parameter patterns, and determine if they adhere to the American College of Radiology (ACR) guidelines. The retrospective analysis included data from 48 eligible participants from 13 MRI centers in March 2021. Descriptive and correlation data analysis were performed using IBM SPSS statistics version_20 and Excel 2013. Most MRI centers (50%) were private outpatient clinics with closed MRI machines above 1 Tesla. Most participants (62.5%) were male, and shoulder pain (47.9%) was the main clinical indication. Most shoulder orientations (68.7%, 33/48) were right shoulders, and the coronal MRI planes (43%, 121/280) were the most common. The alignment percentage for the axial plane was 100%, but MRI artifacts of the shoulder were present in 8.2% of cases (23/280). Dark fluid T1-W coronal sequence was not conducted in 25% of the cases. The percentage of the field view (FOV) within ACR recommendations was 45% (126/281), and slice thickness parameters were 96% (269/281). The recommended pixel area for all sequences was 47.9% (134/280), encompassing all axial, sagittal oblique, and coronal planes. However, crucial parameters, such as FOV and slice thickness, were inadequate and did not meet the ACR guidelines, resulting in suboptimal image quality of shoulder MRI. To improve MRI image quality, it is recommended that MRI technologists receive ongoing education and training on appropriate MRI image parameters.


Subject(s)
Radiology , Shoulder , Humans , Male , Female , Shoulder/diagnostic imaging , Retrospective Studies , Jordan , Magnetic Resonance Imaging/methods
13.
Comput Med Imaging Graph ; 107: 102228, 2023 07.
Article in English | MEDLINE | ID: mdl-37054491

ABSTRACT

Cerebrovascular segmentation based on phase-contrast magnetic resonance angiography (PC-MRA) provides patient-specific intracranial vascular structures for neurosurgery planning. However, the vascular complex topology and spatial sparsity make the task challenging. Inspired by the computed tomography reconstruction, this paper proposes a Radon Projection Composition Network (RPC-Net) for cerebrovascular segmentation in PC-MRA, aiming to enhance distribution probability of vessels and fully obtain the vascular topological information. Multi-directional Radon projections of the images are introduced and a two-stream network is used to learn the features of the 3D images and projections. The projection domain features are remapped to the 3D image domain by filtered back-projection transform to obtain the image-projection joint features for predicting vessel voxels. A four-fold cross-validation experiment was performed on a local dataset containing 128 PC-MRA scans. The average Dice similarity coefficient, precision and recall of the RPC-Net achieved 86.12%, 85.91% and 86.50%, respectively, while the average completeness and validity of the vessel structure were 85.50% and 92.38%, respectively. The proposed method outperformed the existing methods, especially with significant improvement on the extraction of small and low-intensity vessels. Moreover, the applicability of the segmentation for electrode trajectory planning was also validated. The results demonstrate that the RPC-Net realizes an accurate and complete cerebrovascular segmentation and has potential applications in assisting neurosurgery preoperative planning.


Subject(s)
Algorithms , Magnetic Resonance Angiography , Humans , Magnetic Resonance Angiography/methods , Imaging, Three-Dimensional/methods , Tomography, X-Ray Computed , Cerebrovascular Circulation , Image Processing, Computer-Assisted/methods
14.
Front Pediatr ; 11: 1058567, 2023.
Article in English | MEDLINE | ID: mdl-36911024

ABSTRACT

Children with hypoplastic left heart syndrome share unique hemodynamic features that alter lymphatic integrity at all stages of palliation. Lymphatic congestion is almost universal in this patient group to some extent. It may lead to reversal of lymphatic flow, the development of abnormal lymphatic channels and ultimately decompression and loss of protein rich lymphatic fluid into extra lymphatic compartments in prone individuals. Some of the most devastating complications that are associated with single ventricle physiology, notably plastic bronchitis and protein losing enteropathy, have now been proven to be lymphatic in origin. Based on the new pathophysiologic concept new diagnostic and therapeutic strategies have recently been developed. Dynamic contrast magnetic resonance lymphangiography is now mainstay in diagnosis of lymphatic insufficiency and allows a thorough assessment of anatomy and function of the main lymphatic compartments through intranodal, intrahepatic and intramesenteric lymphatic imaging. Contrast enhanced ultrasound can evaluate thoracic duct patency and conventional fluoroscopic lymphangiography has been refined for evaluation of patients where magnetic resonance imaging cannot be performed. Novel lymphatic interventional techniques, such as thoracic duct embolization, selective lymphatic duct embolization and liver lymphatic embolization allow to seal abnormal lymphatic networks minimally invasive and have shown to resolve symptoms. Innominate vein turn-down procedures, whether surgical or interventional, have been designed to reduce lymphatic afterload and increase systemic preload effectively in the failing Fontan circulation. Outflow obstruction can now be managed with new microsurgical techniques that create lympho-venous anastomosis. Short term results for all of these new approaches are overall promising but evidence is sparse and long-term outcome still has to be defined. This review article aims to summarize current concepts of lymphatic flow disorders in single ventricle patients, discuss new emerging diagnostic and therapeutic strategies and point out lacks in evidence and needs for further research on this rapidly growing topic.

15.
J Cardiovasc Magn Reson ; 25(1): 22, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36978131

ABSTRACT

BACKGROUND: Different software programs are available for the evaluation of 4D Flow cardiovascular magnetic resonance (CMR). A good agreement of the results between programs is a prerequisite for the acceptance of the method. Therefore, the goal was to compare quantitative results from a cross-over comparison in individuals examined on two scanners of different vendors analyzed with four postprocessing software packages. METHODS: Eight healthy subjects (27 ± 3 years, 3 women) were each examined on two 3T CMR systems (Ingenia, Philips Healthcare; MAGNETOM Skyra, Siemens Healthineers) with a standardized 4D Flow CMR sequence. Six manually placed aortic contours were evaluated with Caas (Pie Medical Imaging, SW-A), cvi42 (Circle Cardiovascular Imaging, SW-B), GTFlow (GyroTools, SW-C), and MevisFlow (Fraunhofer Institute MEVIS, SW-D) to analyze seven clinically used parameters including stroke volume, peak flow, peak velocity, and area as well as typically scientifically used wall shear stress values. Statistical analysis of inter- and intrareader variability, inter-software and inter-scanner comparison included calculation of absolute and relative error (ER), intraclass correlation coefficient (ICC), Bland-Altman analysis, and equivalence testing based on the assumption that inter-software differences needed to be within 80% of the range of intrareader differences. RESULTS: SW-A and SW-C were the only software programs showing agreement for stroke volume (ICC = 0.96; ER = 3 ± 8%), peak flow (ICC: 0.97; ER = -1 ± 7%), and area (ICC = 0.81; ER = 2 ± 22%). Results from SW-A/D and SW-C/D were equivalent only for area and peak flow. Other software pairs did not yield equivalent results for routinely used clinical parameters. Especially peak maximum velocity yielded poor agreement (ICC ≤ 0.4) between all software packages except SW-A/D that showed good agreement (ICC = 0.80). Inter- and intrareader consistency for clinically used parameters was best for SW-A and SW-D (ICC = 0.56-97) and worst for SW-B (ICC = -0.01-0.71). Of note, inter-scanner differences per individual tended to be smaller than inter-software differences. CONCLUSIONS: Of all tested software programs, only SW-A and SW-C can be used equivalently for determination of stroke volume, peak flow, and vessel area. Irrespective of the applied software and scanner, high intra- and interreader variability for all parameters have to be taken into account before introducing 4D Flow CMR in clinical routine. Especially in multicenter clinical trials a single image evaluation software should be applied.


Subject(s)
Magnetic Resonance Imaging , Software , Humans , Female , Reproducibility of Results , Predictive Value of Tests , Aorta
16.
Fluids Barriers CNS ; 20(1): 5, 2023 Jan 18.
Article in English | MEDLINE | ID: mdl-36653870

ABSTRACT

BACKGROUND: Detecting changes in pulsatile cerebrospinal fluid (CSF) flow may assist clinical management decisions, but spinal CSF flow is relatively understudied. Traumatic spinal cord injuries (SCI) often cause spinal cord swelling and subarachnoid space (SAS) obstruction, potentially causing pulsatile CSF flow changes. Pigs are emerging as a favoured large animal SCI model; therefore, the aim of this study was to characterise CSF flow along the healthy pig spine. METHODS: Phase-contrast magnetic resonance images (PC-MRI), retrospectively cardiac gated, were acquired for fourteen laterally recumbent, anaesthetised and ventilated, female domestic pigs (22-29 kg). Axial images were obtained at C2/C3, T8/T9, T11/T12 and L1/L2. Dorsal and ventral SAS regions of interest (ROI) were manually segmented. CSF flow and velocity were determined throughout a cardiac cycle. Linear mixed-effects models, with post-hoc comparisons, were used to identify differences in peak systolic/diastolic flow, and maximum velocity (cranial/caudal), across spinal levels and dorsal/ventral SAS. Velocity wave speed from C2/C3 to L1/L2 was calculated. RESULTS: PC-MRI data were obtained for 11/14 animals. Pulsatile CSF flow was observed at all spinal levels. Peak systolic flow was greater at C2/C3 (dorsal: - 0.32 ± 0.14 mL/s, ventral: - 0.15 ± 0.13 mL/s) than T8/T9 dorsally (- 0.04 ± 0.03 mL/s; p < 0.001), but not different ventrally (- 0.08 ± 0.08 mL/s; p = 0.275), and no difference between thoracolumbar levels (p > 0.05). Peak diastolic flow was greater at C2/C3 (0.29 ± 0.08 mL/s) compared to T8/T9 (0.03 ± 0.03 mL/s, p < 0.001) dorsally, but not different ventrally (p = 1.000). Cranial and caudal maximum velocity at C2/C3 were greater than thoracolumbar levels dorsally (p < 0.001), and T8/T9 and L1/L2 ventrally (p = 0.022). Diastolic velocity wave speed was 1.41 ± 0.39 m/s dorsally and 1.22 ± 0.21 m/s ventrally, and systolic velocity wave speed was 1.02 ± 0.25 m/s dorsally and 0.91 ± 0.22 m/s ventrally. CONCLUSIONS: In anaesthetised and ventilated domestic pigs, spinal CSF has lower pulsatile flow and slower velocity wave propagation, compared to humans. This study provides baseline CSF flow at spinal levels relevant for future SCI research in this animal model.


Subject(s)
Cerebrospinal Fluid Pressure , Magnetic Resonance Imaging , Humans , Female , Swine , Animals , Retrospective Studies , Magnetic Resonance Imaging/methods , Spinal Cord/diagnostic imaging , Sus scrofa , Cerebrospinal Fluid/diagnostic imaging
17.
Cardiovasc Eng Technol ; 14(1): 1-12, 2023 02.
Article in English | MEDLINE | ID: mdl-35618870

ABSTRACT

PURPOSE: To evaluate the agreement of 4D flow cMRI-derived bulk flow features and fluid (blood) velocities in the carotid bifurcation using prospective and retrospective gating techniques. METHODS: Prospective and retrospective ECG-gated three-dimensional (3D) cine phase-contrast cardiac MRI with three-direction velocity encoding (i.e., 4D flow cMRI) data were acquired in ten carotid bifurcations from men (n = 3) and women (n = 2) that were cardiovascular disease-free. MRI sequence parameters were held constant across all scans except temporal resolution values differed. Velocity data were extracted from the fluid domain and evaluated across the entire volume or at defined anatomic planes (common, internal, external carotid arteries). Qualitative agreement between gating techniques was performed by visualizing flow streamlines and topographical images, and statistical comparisons between gating techniques were performed across the fluid volume and defined anatomic regions. RESULTS: Agreement in the kinematic data (e.g., bulk flow features and velocity data) were observed in the prospectively and retrospectively gated acquisitions. Voxel differences in time-averaged, peak systolic, and diastolic-averaged velocity magnitudes between gating techniques across all volunteers were 2.7%, 1.2%, and 6.4%, respectively. No significant differences in velocity magnitudes or components ([Formula: see text], [Formula: see text], [Formula: see text]) were observed. Importantly, retrospective acquisitions captured increased retrograde flow in the internal carotid artery (i.e., carotid sinus) compared to prospective acquisitions (10.4 ± 6.3% vs. 4.6 ± 5.3%; [Formula: see text] < 0.05). CONCLUSION: Prospective and retrospective ECG-gated 4D flow cMRI acquisitions provide comparable evaluations of fluid velocities, including velocity vector components, in the carotid bifurcation. However, the increased temporal coverage of retrospective acquisitions depicts increased retrograde flow patterns (i.e., disturbed flow) not captured by the prospective gating technique.


Subject(s)
Carotid Arteries , Magnetic Resonance Imaging , Male , Humans , Female , Retrospective Studies , Prospective Studies , Blood Flow Velocity , Magnetic Resonance Imaging/methods , Carotid Arteries/diagnostic imaging , Imaging, Three-Dimensional/methods , Reproducibility of Results
18.
Cardiovasc Eng Technol ; 14(1): 104-114, 2023 02.
Article in English | MEDLINE | ID: mdl-35879586

ABSTRACT

PURPOSE: This study establishes a reliable image-based multivariable technique for measuring the trans-stenotic pressure gradient. METHODS: A self-made in vitro steady flow model based on adjustable velocities and stenotic properties were used as the experimental subject. The pre-stenotic flow velocity, severity, and length of the stenosis were used as the input variables. Based on equations used to fit the plots of the physically measured pressure gradient values versus each input variable, a multivariable formula for the pressure gradient measurement could then be derived. The flow model was scanned using velocity-encoded phase-contrast magnetic resonance imaging (PC-MRI) to validate the derived formula while simultaneously measuring the trans-stenotic pressure gradient. The correlation between the physically-measured pressure gradient values and the pressure gradient values calculated using the new formula were subsequently analyzed. RESULTS: The results of linear regression analysis using the physically measured pressure gradient values for the new method were compared to values obtained using the simplified Bernoulli equation (R2, 0.991, and 0.975, respectively). In a paired t-test, no statistically significant difference was found between the new method and the physical measurements. CONCLUSIONS: The derived multivariable technique was found to reliably measure the trans-stenotic pressure gradient, with better performance than a traditional procedure based on the simplified Bernoulli equation.


Subject(s)
Magnetic Resonance Imaging , Humans , Constriction, Pathologic , Linear Models , Blood Flow Velocity
19.
J Magn Reson Imaging ; 57(3): 763-773, 2023 03.
Article in English | MEDLINE | ID: mdl-35716109

ABSTRACT

BACKGROUND: In phase-contrast (PC) MRI, several dual velocity encoding methods have been proposed to robustly increase velocity-to-noise ratio (VNR), including a standard dual-VENC (SDV), an optimal dual-VENC (ODV), and bi- and triconditional methods. PURPOSE: To develop a correction method for the ODV approach and to perform a comparison between methods. STUDY TYPE: Case-control study. POPULATION: Twenty-six volunteers. FIELD STRENGTH/SEQUENCE: 1.5 T phase-contrast MRI with VENCs of 50, 75, and 150 cm/second. ASSESSMENT: Since we acquired single-VENC protocols, we used the background phase from high-VENC (VENCH ) to reconstruct the low-VENC (VENCL ) phase. We implemented and compared the unwrapping methods for different noise levels and also developed a correction of the ODV method. STATISTICAL TESTS: Shapiro-Wilk's normality test, two-way analysis of variance with homogeneity of variances was performed using Levene's test, and the significance level was adjusted by Tukey's multiple post hoc analysis with Bonferroni (P < 0.05). RESULTS: Statistical analysis revealed no extreme outliers, normally distributed residuals, and homogeneous variances. We found statistically significant interaction between noise levels and the unwrapping methods. This implies that the number of non-unwrapped pixels increased with the noise level. We found that for ß = VENCL /VENCH  = 1/2, unwrapping methods were more robust to noise. The post hoc test showed a significant difference between the ODV corrected and the other methods, offering the best results regarding the number of unwrapped pixels. DATA CONCLUSIONS: All methods performed similarly without noise, but the ODV corrected method was more robust to noise at the price of a higher computational time. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY STAGE: 1.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Humans , Image Processing, Computer-Assisted/methods , Case-Control Studies , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Blood Flow Velocity , Reproducibility of Results
20.
Acta Radiol ; 64(3): 1166-1174, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35786055

ABSTRACT

BACKGROUND: Dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) could be helpful to separate true disease progression from pseudo-progression in brain metastases when assessing the need for retreatment. However, the selection of arterial input functions (AIFs) is not standardized for analysis, limiting its use for this application. PURPOSE: To compare population-based AIFs, AIFs specific to each patient, and AIFs specific to every visit in the longitudinal follow-up of brain metastases. MATERIAL AND METHODS: Longitudinal data were collected from eight patients before treatment (6 of 8 patients) and after treatment (6-17 visits). Imaging was performed using a 1.5-T MRI system. Lesions were segmented by subtracting precontrast images from postcontrast images. Cerebral blood volume (rCBV) and cerebral blood flow (rCBF) were computed, and Pearson's product moment correlation coefficients were calculated to evaluate similarity of DSC parameters dependent on various AIF choices across time. AIF shape characteristics were compared. Parameter differences between white matter (WM) and gray matter (GM) were obtained to determine which AIF choice maximizes tissue differentiation. RESULTS: Although DSC parameters follow similar patterns in time, the various AIF selections cause large parameter variations with relative standard deviations of up to ±60%. AIFs sampled in one patient across sessions more similar in shape than AIFs sampled across patients. Estimates of rCBV based on scan-specific AIFs differentiated better between perfusion in WM and GM than patient-specific or population-based AIFs (P ≤ 0.02). CONCLUSION: Results indicate that scan-specific AIFs are the best choice for DSC-MRI parameter estimations in the longitudinal follow-up of brain metastases.


Subject(s)
Brain Neoplasms , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/pathology , Arteries , Gray Matter , Algorithms , Cerebrovascular Circulation/physiology , Contrast Media
SELECTION OF CITATIONS
SEARCH DETAIL