Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 373
Filter
1.
J Prosthodont ; 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-38985129

ABSTRACT

PURPOSE: The objective of this study was to evaluate the effect of (Er,Cr: YSGG) laser debonding treatment on optical properties and surface roughness of veneers made of different ceramic materials. MATERIALS AND METHODS: Thirty bovine incisors were prepared to receive laminate veneers and divided into three groups (n = 10) according to ceramic material where group (E): IPS e.max CAD, group (S): Vita Suprinity, and group (C): Celtra Duo. Blocks were sectioned into 0.5 mm thickness plates and cemented on the labial surface of incisors using resin cement. The Er,Cr: YSGG laser was applied to each specimen at 4.5 W and 25 Hz for group E and at 6 W and 25 Hz for groups S and C. Color change (△E00), translucency parameter (TP) and surface roughness in µm (Ra) values were measured and calculated before and after laser treatment. Data were analyzed using two-way mixed model ANOVA at a significance level of p < 0.05. RESULTS: The highest mean △E00 value was recorded in group E (1.35 ± 0.09) followed by group S (1.08 ± 0.16) and then group C (0.93 ± 0.10) with a significant difference between them (p < 0.001). All groups exceeded the perceptibility threshold but remained below the acceptability threshold. No statistically significant difference was found in TP except for group E (p = 0.019). Ra values after laser debonding showed significantly higher values than before laser treatment in all three groups (p < 0.001). CONCLUSION: Er,Cr: YSGG laser can be safely used for debonding ceramic veneers without altering the optical properties but it does increase the roughness of debonded ceramic restorations.

2.
Materials (Basel) ; 17(11)2024 May 30.
Article in English | MEDLINE | ID: mdl-38893916

ABSTRACT

Bimetallic lined pipe (BLP) has been increasingly used in offshore and subsea oil and gas structures, but how to identify the invisible inner defects such as liner wall thinning and interface debonding is a challenge for future development. A nondestructive testing (NDT) method based on pulsed eddy current testing (PECT) has been proposed to face these difficulties. The inspection of the BLP specimen (AISI1020 base tube and SS304 liner) is implemented from outside of the pipe by using a transmitter-receiver-type PECT probe consisting of two induction coils. By simplifying the BLP specimen to stratified conductive plates, the electromagnetic field interaction between the PECT probe and specimen is analytically modeled, and the probe inspection signals due to liner wall thinning and interface debonding are calculated. In order to highlight the weak response (in microvolts) from the liner, the inspection signals are subtracted by the signal, which is calculated in the case of only having a base tube, yielding differential PECT signals. The peak voltage of the differential signal is selected to characterize the liner wall thinning and interface debonding due to its distinguishable and linear variation. Experiment verification is also carried out on a double-walled specimen simulated by a combination of a Q235 casing pipe and SS304 tubes of different sizes. The experimental results basically agree with the analytical predictions. The peak value of the PECT signal has an ascending and descending variation with the increase in the remaining liner wall thickness and debonding gap, respectively, while the negative peak value shows opposite changes. The peak value exhibits a larger sensitivity than the negative peak value. The proposed method shows potential promise in practical applications for the evaluation of the inner defects in BLP lines.

3.
Lasers Med Sci ; 39(1): 156, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38869676

ABSTRACT

The risk of enamel deterioration that frequently coexists with debonding of orthodontic teeth brackets elevates the mandate for finding an optimum approach for debonding them without harmful effects. This in-vitro study is intended to compare the effects of two different laser modes (scanning and circular) and a conventional method on the enamel surface after debonding orthodontic brackets. 66 extracted premolars were assigned into 3 groups. After that, light-cure composite resin was used to attach the ceramic brackets to the teeth. Amongst the test groups, Group I: specimens that were debonded using conventional debonding using pliers; Group 2: specimens that were debonded using Er, Cr: YSGG laser applications using the circular motion method; and Group 3: specimens that were debonded using Er, Cr: YSGG laser applications using the scanning motion method. Adhesive Remnant Index (ARI) assessment, intra-pulpal temperature increase, enamel surface roughness after polishing, and assessment of the microstructure of enamel were carried out with scanning electron microscopy. The gathered information was examined statistically. The conventional debonding method had a significantly higher proportion of adhesive remnant index (ARI) scores of 2 and 3 in comparison to the circular (p < .004) and scanning laser groups (p < .001). There was no significant difference in ARI scores between the circular and scanning laser groups (p > .05). Moreover, the circular and scanning laser debonding methods resulted in a significantly higher proportion of Enamel Surface Roughness (ESR) scores of 0 and a lower proportion of ESR scores of 3 compared to the conventional technique group (p < .001). However, there was no significant difference in ESR scores between the circular and scanning laser methods (p = .945). Lastly, the average intra-pulpal temperature was significantly higher in the circular laser group (1.9 ± 0.5 ) compared to the scanning laser group (0.9 ± 0.2) with p < .001. Er, Cr: YSGG laser irradiation is a tool that shows promise for debonding ceramic brackets with minimal harm to the enamel surface. The scanning laser technique is more desirable due to the lower intra-pulpal temperature increase.


Subject(s)
Ceramics , Dental Debonding , Dental Enamel , Lasers, Solid-State , Orthodontic Brackets , Surface Properties , Humans , Dental Enamel/radiation effects , Dental Debonding/methods , Dental Debonding/instrumentation , Lasers, Solid-State/therapeutic use , In Vitro Techniques , Microscopy, Electron, Scanning , Bicuspid
4.
Cureus ; 16(5): e61050, 2024 May.
Article in English | MEDLINE | ID: mdl-38915986

ABSTRACT

The development of ceramic brackets in orthodontics three decades ago emerged as a response to the increasing patient demand for less visible orthodontic appliances. While these brackets provide superior aesthetics, they are characterized by lower fracture toughness and higher bond strength in contrast to metal brackets. These properties present challenges during the debonding step, including the risk of enamel micro-fractures and cracks. Historically, various strategies have been developed to address challenges associated with debonding, reduce patient discomfort, and ensure that the bond failure site is confined to the bracket-adhesive interface. This included the use of specially designed debonding pliers, electrothermal debonding, ultrasonic technique, and chemical agents. Recently, there has been a shift towards utilizing different types of laser irradiation for this purpose. The burgeoning strategy, however, requires diligent scientific scrutiny to establish a standardized protocol with particular laser parameters and ultimately achieve the goal of enhancing the patient experience by reducing discomfort. This article offers a narrative review of laser-aided debonding of ceramic brackets, aimed at comparing different laser types, presenting their benefits and downsides, validating the efficiency of each method, and summarizing the published literature on this subject. It also provides insights for orthodontists on reducing patient discomfort that usually accompanies debonding ceramic brackets by delving into the science behind the use of lasers for this purpose.

5.
Dent Mater J ; 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38925979

ABSTRACT

No effective technique exists for removing adhesive remnants following bracket debonding. We propose that fluorescence imaging using europium ions (Eu3+) offers an effective solution for minimizing iatrogenic enamel damage. This study aimed to assess the impact of different mixing ratios of monomer mixtures on the photoluminescence and flexural properties of a newly developed fluorescent adhesive. Four monomer blends with varying urethane dimethacrylate (UDMA) to triethylene glycol dimethacrylate (TEGDMA) ratios were prepared and polymerized. The blends contained 0.1 wt% of tris(1,3-diphenyl-1,3-propanedionato)(1,10-phenanthroline) Eu(III), [Eu(DBM)3Phen], as the phosphor. Optical measurements and flexural tests were conducted for each resin specimen. The emission spectra exhibited narrow bands corresponding to the 4f-4f transitions of the Eu3+ ions. The photoluminescence properties remained unaffected by the mixing ratio, whereas the mechanical properties tended to improve with higher UDMA content. We conclude that the Eu(DBM)3Phen-containing resin shows promise as a fluorescent orthodontic adhesive that contributes to preserving enamel health.

6.
Cureus ; 16(4): e58957, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38800248

ABSTRACT

Aim This retrospective study aimed to evaluate if E-max veneers over five years caused changes in gingival, periodontal health, and veneer failures. Background As aesthetic dentistry progresses, dental veneers are becoming increasingly popular in both general and specialized dental practices. Due to technological advancements in dental ceramics and adhesive systems, porcelain veneers have become a highly sought-after solution for improving aesthetics in dental patients. The success of porcelain laminate veneers, a commonly used method for aesthetic restoration, relies on various factors. E-max veneers are frequently utilized, with their long-term durability contingent upon factors such as color stability, resistance to abrasion, as well as good compressive, tensile, and shear strength, along with maintaining marginal integrity. Methodology In this study, data was collected through a checklist form used to record clinical parameters. The clinical parameters evaluated were inflammation and bleeding on probing (BOP). The gingival health was evaluated by gingival index, gingival color, texture, and bleeding on probing, and periodontal health was evaluated by the pocket depth and radiographic evaluations. Finally, the veneer was visually inspected for chipping, staining, and debonding history. The score for most of the cases ranged between 0-1, with only 10 cases displaying moderate gingival inflammation and BOP (Gingival Index 2). Siemens Orthopantomogram (OPG) systems were used for radiological evaluation and documentation of cases. E-max porcelain veneers were only included in the research. Results Out of 28 patients, each with 6-to-10-unit veneer cases was examined, 18 patients (64.3%) displayed healthy gingival status with no bleeding area recorded in none of the veneers amongst the 6 to 10 units. In 10 patients (35.7%) most of the veneers had inflamed gingival tissue that was bleeding on probing. The majority revealed the presence of stippling (92.9%), absence of recession (96.4%), and pocket depth (67.9%). Half of our participants had their veneer for more than five years (50%) and the majority presented with no significant changes in veneer recorded like marginal staining, debonding, or chipping (89.3%). Conclusion Multiple factors such as patient selection, proper treatment planning, and design, including material selection, play a significant role in the long-lasting success of ceramic veneers. The retrospective study indicated that proper oral hygiene measures are vital for the long-term sustainability of E max veneers.

7.
BMC Oral Health ; 24(1): 609, 2024 May 25.
Article in English | MEDLINE | ID: mdl-38796434

ABSTRACT

BACKGROUND: High speed electric handpieces have recently been growing in popularity among dental professionals. Advantages include smoother surface preparation and increased cutting efficiency. AIM: The primary objective was to compare enamel surface roughness following resin cleanup after bracket debonding using highspeed air turbine versus electric handpiece. The secondary objective was to record the time needed for resin-clean up. METHOD: Forty deidentified freshly extracted human premolars were cleaned and sectioned at the cement-enamel junction. The crowns were embedded in acrylic blocks. Enamel surface roughness parameters (Ra, Rz, Rp and Rv) were measured using a stylus profilometer. Brackets were bonded using a light-cure orthodontic adhesive and stored in distilled water for 24 h. Following bracket debonding, the specimens were randomly divided into 2 groups: First group: resin clean-up was carried out using a 12-fluted carbide bur mounted on a high-speed air turbine; and second group: where an electric handpiece was used. Surface roughness parameters were measured following resin clean up and after polishing using pumice and a rubber cup. Time needed for resin clean-up was recorded. Differences in enamel surface roughness and time between groups were compared using repeated measures ANOVA and independent samples t-test, respectively at P ≤ 0.05. RESULTS: The electric handpiece groups showed significantly higher values for Ra, Rz and Rp both following resin cleanup and polishing. Time taken for resin cleanup was significantly longer for the electric handpiece group. CONCLUSION: Considering both surface roughness and time, electric handpiece do not seem to add greater effectiveness or efficiency to resin cleanup following orthodontic bracket debonding.


Subject(s)
Dental Debonding , Dental Enamel , Dental High-Speed Equipment , Surface Properties , Humans , Dental Debonding/methods , In Vitro Techniques , Resin Cements/chemistry , Orthodontic Brackets , Time Factors , Bicuspid , Dental Polishing/methods
8.
J Clin Pediatr Dent ; 48(3): 31-36, 2024 May.
Article in English | MEDLINE | ID: mdl-38755979

ABSTRACT

The purpose of this study was to quantitatively evaluate adhesive remnants on the enamel surface following bracket debonding using a freezing element. Thirty-six sound premolars were used in this study. In each case, a bracket was bonded onto each tooth with conventional light-cured composite resin and de-bonded after one week. Freezing of the underlying composite through the bracket was performed immediately before debonding with a portable cryosurgical system (-55 °C). Specimens were divided into three groups according to the duration of freezing: a control group without freezing was used as a reference and two interventional groups with different durations of freezing (15 or 40 s). Brackets were removed by using debonding pliers to squeeze the wings of the bracket in an occluso-gingival manner. Adhesive remnants on the tooth were then quantitatively evaluated by stereo-microscopy. Pearson's Chi-squared test was used to investigate the relationship between the proportion of remaining resin and the group of teeth. In the control group, 100% of the composite remained on the enamel surface of all specimens. Significantly less adhesive remnants were found in the intervention groups (p = 0.001 for the 15 s group and p = 0.043 for the 40 s group). There was no significant difference between the two interventions (p = 0.165) in terms of the proportion of remaining adhesive remnants. Freezing of the bracket and the underlying adhesive resin prior to bracket debonding may favorably alter the behavioral pattern of composite fracture, thus reducing the extent of adhesive remnants on the enamel. Increasing the freezing time from 15 to 40 s did not exert significant effects on adhesive remnants following debonding. Further research now needs to investigate the effect of freezing on the mechanical properties of the adhesive remnants and its in-vivo effect on pulp vitality over both short- and long-terms.


Subject(s)
Composite Resins , Dental Debonding , Freezing , Orthodontic Brackets , Humans , Dental Debonding/methods , Composite Resins/chemistry , Dental Enamel , In Vitro Techniques , Resin Cements/chemistry , Dental Cements/chemistry , Bicuspid , Materials Testing
9.
J Funct Biomater ; 15(5)2024 May 10.
Article in English | MEDLINE | ID: mdl-38786634

ABSTRACT

AIM: The objective of this study was to explore the effects of fixed orthodontic appliances on enamel structure by assessing microfractures, surface roughness, and alterations in color. METHODS: This review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A systematic search of online databases was conducted using the keywords 'enamel' AND 'orthodontic debonding'. Eligibility criteria included both in vivo and ex vivo clinical trials conducted on human teeth. RESULTS AND DISCUSSION: A total of 14 relevant papers were analyzed. Various instruments and techniques were utilized across different studies to assess surface roughness, color change, and surface fractures. CONCLUSIONS: The findings of this study suggest that ceramic brackets may lead to an increase in enamel fractures, particularly during bracket removal. The surface roughness of enamel exhibits variability depending on the adhesive substance and polishing methods used post-removal. Fixed orthodontic appliances could induce changes in enamel color, which may be alleviated by the use of nano-hydroxyapatite or specific polishing techniques. Further research is necessary to identify effective strategies for managing these color changes and improving the overall outcomes of fixed orthodontic treatment.

10.
Clin Exp Dent Res ; 10(3): e901, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38770577

ABSTRACT

OBJECTIVES: The study aimed to evaluate the debonding resistance of three different endocrown designs on molar teeth, using three different zirconia surface pretreatments. MATERIAL AND METHOD: Ninety human mandibular first molars were divided into three main groups: endocrowns without ferrule, with 1 mm ferrule, and with 2 mm ferrule. The subgroups were defined by their surface pretreatment method used (n = 15): 50 µm alumina air-particle abrasion, silica coating using 30 µm Cojet™ particles, and Zircos-E® etching. The endocrowns were fabricated using multilayer zirconia ceramic, cemented with self-adhesive resin cement, and subjected to 5000 thermocycles (5-55°C) before debonding. The data obtained were analyzed using a two-way ANOVA. RESULTS: All test specimens survived the thermocyclic aging. The results indicated that both the preparation design and the surface treatment had a significant impact on the resistance to debonding of the endocrowns (p < .001). The 2 mm ferrule followed by the 1 mm ferrule designs exhibited the highest debonding resistance, both were superior to the endocrown without ferrule. Zircos-E® etching and silica coating yielded comparable debonding resistance, which were significantly higher than alumina air-particle abrasion. All endocrowns demonstrated a favorable failure mode. CONCLUSIONS: All designs and surface treatments showed high debonding resistance for a single restoration. However, ferrule designs with Zircos-E® etching or silica coating may represent better clinical options compared to the nonferrule design or alumina airborne-particle abrasion. Nonetheless, further research, including fatigue testing and evaluations with different luting agents is recommended.


Subject(s)
Aluminum Oxide , Silicon Dioxide , Surface Properties , Zirconium , Aluminum Oxide/chemistry , Humans , Silicon Dioxide/chemistry , Zirconium/chemistry , Molar , Materials Testing , Air Abrasion, Dental/methods , Resin Cements/chemistry , Dental Etching/methods , Dental Stress Analysis , Dental Prosthesis Design
11.
BMC Oral Health ; 24(1): 570, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38802801

ABSTRACT

BACKGROUND: Erbium lasers safely offer the possibility of reuse for debonded restorations. Since these lasers have a high affinity for water molecules, they are absorbed by resin cement causing explosive ablation of the cement and thus, the restoration debonds. The efficiency of this process depends on many factors, including the ceramic type, its chemical composition and thickness. Therefore, this study was designed to test the time taken to debond ultrathin occlusal veneers made of three types of milled ceramic materials and evaluate the integrity of these restorations after debonding. METHODS: Three ceramic types were evaluated in this study: lithium disilicate (IPS Emax CAD), highly condensed lithium disilicate (GC initial®LiSi), and translucent zirconia (Katana zirconia STML). Each group consisted of 8 occlusal veneers of 0.5 mm thickness. The samples were cemented to the occlusal surfaces of the upper molar teeth. An Er; Cr: YSGG laser was applied to the occlusal veneers using the scanning method, and time until debonding was calculated. The debonded samples were then inspected under a stereomicroscope for possible damage. Numerical data are presented as the mean with 95% confidence interval (CI), standard deviation (SD), minimum (min.) and maximum (max.) values. Normality and variance homogeneity assumptions were confirmed using Shapiro-Wilk's and Levene's tests, respectively. Data were normally distributed and were analyzed using one-way ANOVA followed by Tukey's post hoc test. The significance level was set at p < 0.05 for all tests. Statistical analysis was performed with R statistical analysis software version 4.3.2 for Windows (R Core Team (2023). R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria. URL https://www.R-project.org/). RESULTS: There was no significant difference in debonding time between the different materials (p = 0.995). The longest debonding time was found for Katana STML (87.52 ± 20.45) (seconds), followed by Emax (86.94 ± 20.63) (seconds), while the lowest value was found for LiSi initial (86.14 ± 25.16) (seconds). In terms of damage to the debonded veneers, The Emax and zirconia samples showed no damage. However, 40% of the LiSi samples fractured during debonding, and 20% exhibited cracks. Only 40% of the LiSi samples were sound after debonding. CONCLUSION: Er; Cr: YSGG laser can be used efficiently to remove ceramic occlusal veneers. However, its effect on LiSi restorations needs further research.


Subject(s)
Ceramics , Computer-Aided Design , Dental Porcelain , Dental Veneers , Zirconium , Ceramics/chemistry , Dental Porcelain/chemistry , Humans , Zirconium/chemistry , Lasers, Solid-State/therapeutic use , Dental Debonding/methods , Materials Testing
12.
Turk J Orthod ; 37(1): 50-55, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38556953

ABSTRACT

Objective: The objective of the present study was to evaluate the effectiveness of transcutaneous electrical nerve stimulation (TENS) therapy on pain during the debonding procedure. Methods: A placebo-controlled, randomized split - mouth study was conducted on 30 orthodontic patients. The right and left anterior teeth in the maxilla and mandible were randomly allocated to the control and experimental groups (EG) and were stimulated. TENS application was made through a modified electrode probe that was used from an ammeter. The control group (CG) received the mechanical application of the device with no current, whereas the EG received progressively increasing current from 0.1 mA to the point where the patient experienced a mild tingling sensation for 60 s for each tooth. This was followed by a debonding procedure using an orthodontic debonding plier. Pain perception was recorded on a numerical rating scale after debonding each tooth. Results: The mean pain score was higher in the CG than in the EG, and the difference between the two groups was significant (p=0.001). The pain score was higher in the mandibular teeth than in the maxillary teeth, and the difference between the two groups was also significant (p=0.021). Pain score was higher in female subjects than in male subjects, and the difference between the two groups was significant (p=0.015). Conclusion: The application of TENS therapy results in pain reduction during the debonding procedure. The female subjects experienced more pain. Higher pain scores were recorded for the mandibular anterior teeth than for the maxillary teeth.

13.
Materials (Basel) ; 17(7)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38612033

ABSTRACT

Polishing after the removal of brackets is the final step in orthodontic treatment. It is simple to perform, though some studies have reported that polishing causes damage to the enamel surface. An in vitro study was made of the influence of the buccal surface convexity of the tooth upon possible enamel loss when the remaining resin and adhesive are removed after bracket decementing using two different polishing modes: a tungsten carbide bur at low and high speeds. The convexity of the buccal surface was quantified in 30 incisors and 30 premolars. A stereoscopic microscope was used to obtain photographs of the profile of the crown, and Image J software was used to calculate convexity by dividing the length of a line from the cementoenamel junction to the incisal margin by another line from the mentioned junction to the maximum convexity of the buccal surface. Brackets were cemented on all the teeth and were decemented 24 h later. In both groups, the residual composite was removed with a tungsten carbide bur at a low speed in one-half of the teeth and at a high speed in the other half. The buccal surface of each tooth was then photographed again, and the convexity was calculated and compared against the baseline value. The difference between the two values were taken to represent the enamel loss. The convexity of the premolars was significantly greater than that of the incisors, but this did not result in greater enamel loss when the same polishing mode was used. However, the tungsten carbide bur at a high speed proved more aggressive, causing significantly greater enamel loss than when used at a low speed.

14.
Photobiomodul Photomed Laser Surg ; 42(5): 327-338, 2024 May.
Article in English | MEDLINE | ID: mdl-38598279

ABSTRACT

Objective: This article aims to review the safety and efficacy of the Er:YAG laser in debonding dental accessories. Methods: This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Articles published between 2010 and 2022 on the removal of dental accessories using erbium laser were searched. The selected articles were then classified according to the accessories used: adhesives, brackets, restorations, or implant crowns. Enamel surface roughness, shear bond strength, adhesive remnant index, duration time (t), pulp chamber temperature (T), morphology (M), and other variables were then noted. Results: The dental accessories and adhesives used were described along with the laser parameters used, such as frequency, pulse width, irradiation time, scanning mode, water-air cooling, and other variables. Conclusions: Laser removal using Er:YAG laser of dental accessories such as brackets, crowns, and veneers is fundamentally safe, time-saving, and does not cause damage to the enamel nor the underlying dentin. However, there was no distinct advantage with laser removal seen, such as those residual adhesives of brackets on the tooth surface and temporary adhesives of restorations.


Subject(s)
Dental Debonding , Lasers, Solid-State , Humans , Lasers, Solid-State/therapeutic use
15.
J Arthroplasty ; 2024 Apr 18.
Article in English | MEDLINE | ID: mdl-38642850

ABSTRACT

BACKGROUND: Identification of femoral component debonding in the work-up of painful total knee arthroplasty (TKA) often poses a diagnostic challenge. The purpose of this study was to compare the sensitivity and specificity of radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) for identifying femoral component loosening with debonding at the time of revision of a primary TKA with a recalled polyethylene insert. METHODS: Using an institutional database, we identified all cases of revision TKA performed for this specific implant recall following a primary TKA between 2014 and 2022. Patients who had a preoperative radiograph, CT, and MRI were included (n = 77). Sensitivity, specificity, and positive and negative likelihood ratio (LR) for predicting loosening were compared among the imaging modalities, using the intraoperative evidence of implant loosening as the gold standard. RESULTS: At the time of revision surgery, the femoral component was noted to have aseptic loosening with debonding in 46 of the 77 (60%) of the TKAs. There were no significant differences in demographics in the cohort with femoral debonding compared to those with well-fixed implants. The CT demonstrated a sensitivity of 28% and a specificity of 97%, while the MRI demonstrated a sensitivity of 37% and a specificity of 94% for detecting femoral loosening due to debonding. Both CT and MRI demonstrated poor negative LRs for femoral loosening (LR 0.7). CONCLUSIONS: In this series of revision TKAs for a specific recalled component, neither CT nor MRI accurately diagnosed femoral component debonding. For patients who have this implant, it is imperative to interrogate the implant-cement interface intraoperatively and prepare for full revision surgery as well as marked bone loss secondary to osteolysis.

16.
Cureus ; 16(2): e54740, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38523938

ABSTRACT

Background With the advent of 3D printing, many more possibilities have arisen for treatment planning. 3D rapid prototyping has enabled us to see a whole other dimension that has helped us to give the best possible care for our patients. With more and more advancements being made in this subject, it becomes necessary to check the reliability of the equipment and its effectiveness in the management of the problem at hand. This original study was conducted with the aim of checking the accuracy, dimensional stability, and reliability of orthodontic retainers made on a conventional and digitally fabricated model over a six-month period after debonding. Material and methods The patients were selected from those who have completed fixed orthodontic mechanotherapy from the Department of Orthodontics and Dentofacial Orthopaedics, Sri Guru Ram Das Institute of Dental Sciences and Research, Sri Amritsar. Fifty patients received a clear retainer, which was fabricated for the upper and lower arch after removing the brackets. Patients were included in this study irrespective of their age groups. The manual method used a vacuum-forming machine to fabricate six retainers on stone models. In the digital method, new impressions were taken after three months, and digital models were obtained through 3D scanning and printing, followed by clear retainer fabrication. The data were gathered through a systematic process involving manual and digital methods for clear retainer fabrication and subsequent evaluation. The data obtained was computed for statistical evaluation and comparison. Results Mean and standard deviations of conventional (manual) and digital variables in the two groups were calculated. An ANOVA test was used to evaluate statistically significant differences for mesiodistal width and buccolingual width, and a post hoc Tuckey test was applied for multiple comparisons. The results indicated that most mesiodistal and buccolingual width measurements showed non-significant variations and exhibited a good correlation. Extraction space opening, assessed through an independent t-test for both the maxilla and mandible, also yielded non-significant and comparable results. Additionally, intra-operator and inter-operator measurements using a digital caliper demonstrated high agreement. Intra-class correlation (ICC) values exceeded 0.75, and inter-operator ICC results reflected a high level of agreement ranging from 0.8 to 0.99. Conclusion The primary objective of this study was to establish a correlation between the accuracy, dependability, and clinical efficacy of orthodontic retainers produced using both conventional and digitally created models. This investigation spanned a duration of six months following the removal of orthodontic brackets. The results showed that most of the statistically significant values were due to the inherent potential of the 3D printer for polymerization shrinkage, which, being a stereolithographic 3D printer, had a potential for a slight dimensional shift in the transverse dimension. However, the mean difference between all the models printed was slight and clinically insignificant.

17.
BMC Oral Health ; 24(1): 358, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38509532

ABSTRACT

OBJECTIVE: This study aimed to evaluate enamel surface integrity and time consumed during residual cement removal after bracket debonding using different adhesive removal burs with and without a dental loupe. MATERIAL AND METHODS: Sixty human-extracted premolars were collected, cleaned, mounted, and prepared for orthodontic bracket bonding. Teeth were randomly divided into three main groups (n = 20) based on the adhesive removal method: tungsten carbide system (TC), sof-lex discs system (SD), and diamond system (DB) groups. Then, each group was subdivided into two subgroups (naked eye and magnifying loupe subgroups). The brackets were bonded and then debonded after 24 h, and the Adhesive Remnant Index (ARI) was assessed. The adhesive remnants were removed by different systems, and the final polishing was performed by Silicone OneGloss. The enamel surface roughness was evaluated before bracketing (T0), after residual cement removal (T1), and finally after polishing (T2) using surface Mitutoyo SJ-210 profilometry and Scanning Electron Microscopy (SEM) to determine the Enamel Damage Index (EDI) score. The time consumed for adhesive removal was recorded in seconds. RESULTS: The Kruskal Wallis test showed a statistically significant difference in roughness values at T1 compared to T2 between subgroups (p < 0.001). When comparing EDI at T1 and T2, the Kruskal-Wallis H-test showed statistically significant differences in all subgroups. The pairwise comparisons revealed that EDI scores showed a statistically significant difference at T1 and T2 between DB vs. TC and SD (p = 0.015) but not between TC vs. SD (p = 1.000), indicating the highest roughness value observed in the DB group. The time for cement removal was significantly shorter in the magnifying loupe group than in the naked eye group and was shortest with the TC group, whereas the time was the longest with the DB group (p < 0.05). CONCLUSION: All three systems were clinically satisfactory for residual orthodontic adhesive removal. However, TC system produced the lowest enamel roughness, while the DB system created the greatest. The polishing step created smoother surfaces regardless of the systems used for resin removal.


Subject(s)
Dental Cements , Orthodontic Brackets , Tungsten Compounds , Humans , Bicuspid , Dental Debonding , Dental Enamel , Glass Ionomer Cements , Orthodontic Brackets/adverse effects , Surface Properties
18.
Materials (Basel) ; 17(5)2024 Feb 27.
Article in English | MEDLINE | ID: mdl-38473552

ABSTRACT

This research delves into the characterization of the ultrasonic transmission coefficient pertaining to various types of bonding defects in Fiber-Reinforced Polymer (FRP)-bonded structures. Initially, an ultrasonic transmission coefficient calculation model for FRP-bonded structures in a water immersion environment is established. This model is used to analyze the variation in the ultrasonic transmission coefficient under different defect types, namely intact bonding, interfacial slip, and debonding defects. Subsequently, a frequency domain finite element analysis model of FRP-bonded structures with different defect types is constructed. The simulation validates the accuracy of the theoretical analysis results and concurrently analyzes the variation in the transmission signal when the defects alter. Lastly, an experimental platform for water immersion ultrasonic transmission measurement is set up. The transmission signals under different defect types are extracted through experiments and evaluated in conjunction with theoretical calculations to assess the types of bonding defects.

19.
J Mech Behav Biomed Mater ; 151: 106331, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38176195

ABSTRACT

This in vitro study aimed to determine the optimal frequency and energy settings for debonding zirconia restorations using an erbium-doped yttrium aluminum garnet (Er:YAG) laser. A total of 200 zirconia specimens (5 mm × 5 mm × 1.5 mm) were fabricated from two types of materials: (1) 3 mol% yttria oxide stabilized tetragonal zirconia polycrystalline (3Y-TZP) and (2) 5 mol% yttria oxide stabilized tetragonal zirconia polycrystalline (5Y-TZP). The zirconia specimens were bonded to dentin using resin cement (RelyX Ultimate, 3 M) and divided into 20 groups based on their laser treatments (n = 5). Er:YAG laser treatment was applied at various frequencies (10 Hz and 20 Hz) and energies (80 mJ, 100 mJ, 120 mJ, 140 mJ, 160 mJ, 180 mJ, 200 mJ, 220 mJ, 240 mJ, and 260 mJ). The time required to debond the specimens and the temperature changes that dentin underwent during the laser treatment were recorded. The surface morphologies of the debonded dentin and zirconia specimens were observed using scanning electron microscopy (SEM). Additional zirconia specimens were fabricated for 4-point flexural strength testing and surface roughness measurements. Statistical analyses were conducted using three-way analysis of variance (ANOVA) and Student-Newman-Keuls (SNK)-q tests (α = 0.05). The debonding time of each specimen varied between 4.8 and 160.4 s, with an average value of 59.2 s. The dentin temperature change for each specimen ranged from 2.3 to 3.6 °C, with an average value of 2.7 °C. The debonding time was significantly influenced by the zirconia material type and laser energy, but it was not affected by the laser frequency. Among the specimens, those made of 3Y-TZP needed significantly more time for debonding than 5Y-TZP. The optimal energies were 220 mJ for 3Y-TZP and 200 mJ for 5Y-TZP. The laser frequency, laser energy, and type of zirconia material had no effect on the dentin temperature change. Additionally, no surface alternations were observed on the dentin or zirconia materials after laser treatment. The surface roughness and flexural strength of the zirconia materials remained unchanged after laser treatment. In summary, Er:YAG laser treatment effectively and safely removes zirconia restorations without impacting their mechanical properties, with a safe temperature change of less than 5.6 °C. The optimum frequency and energy settings for debonding 3Y-TZP and 5Y-TZP restorations were found to be 10/20 Hz and 220 mJ and 10/20 Hz and 200 mJ, respectively.


Subject(s)
Lasers, Solid-State , Humans , Materials Testing , Surface Properties , Yttrium/chemistry , Zirconium/chemistry , Oxides , Resin Cements/chemistry , Microscopy, Electron, Scanning
20.
BMC Oral Health ; 24(1): 42, 2024 01 08.
Article in English | MEDLINE | ID: mdl-38191343

ABSTRACT

OBJECTIVE: Incisal composite build-up shows a high failure susceptibility. The incorporation of fiber-reinforced composite (FRC) during composite restoration could improve its strength. Hence the study was planned to compare the effect of various positions of FRC on the strength of composite resin incisal build-ups. METHODS: In maxillary incisors (n = 90), 3 mm of the incisal edge was cut and teeth were categorized into three groups based on the location and number of fibers used during incisal composite build-up - Group I: composite resin; Group II: composite resin and a single fiber palatally and Group III: composite resin along with two fibers palatally. RESULTS: The data showed that group II had the maximum load-bearing values followed by group I and group III. CONCLUSION: Within the confines of our study, it can be concluded that the addition of FRC to the conventional incisal composite build-up increased the overall strength restoration. Such composite restoration reinforced with a single fiber on the palatal side showed the highest load-bearing capacity compared to two fibers reinforced and unreinforced composites. The common mode of failure in group I was in composite resin, in two fibers reinforced at fibers-composite junction, and in one fiber reinforced composite was in the remaining part of the tooth.


Subject(s)
Biomimetics , Research Design , Humans , Composite Resins/therapeutic use , Incisor
SELECTION OF CITATIONS
SEARCH DETAIL
...