Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 164
Filter
1.
Quintessence Int ; 55(6): 430-440, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38847140

ABSTRACT

OBJECTIVE: Artificial intelligence (AI) applications in restorative dentistry have remarkably increased in the past 5 years. This review outlines the applications, promises, and limitations of AI in the most performed procedures in restorative dentistry. METHOD AND MATERIALS: An electronic search was performed in four databases: MEDLINE/PubMed, Embase, Web of Science, and Scopus. The search included articles published in English language without date restriction. Two independent reviewers assessed the eligibility of the studies and performed data extraction. Any discrepancy was resolved by the consensus of a third reviewer. RESULTS: A total of 33 studies were included in this review. For AI applications in restorative dentistry, the included studies were classified into three main groups: (1) diagnosis, detection, and prediction of the disease, (2) detection and prediction of the longevity of dental restorations, and (3) teeth detection and treatments. For each study, the AI model, type of dataset, sample size, and main results (accuracy, precision, sensitivity, and specificity) were reported. CONCLUSIONS: AI systems are promising as advantageous aids for diagnosis, prediction, and treatment in dentistry, with a high degree of accuracy. Despite the AI promises, several limitations are still unresolved and must be addressed to bridge the gap between technology and clinical applications.


Subject(s)
Artificial Intelligence , Dental Restoration, Permanent , Humans , Dental Restoration, Permanent/methods
2.
J Adv Prosthodont ; 16(2): 77-90, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38694191

ABSTRACT

PURPOSE: The study aims to investigate the influence of the ferrule effect and types of posts on the stress distribution in three morphological types of the maxillary central incisor. MATERIALS AND METHODS: Nine models were created for 3 maxillary central incisor morphology types: "Fat" type - crown 12.5 mm, root 13 mm, and buccolingual cervical diameter 7.5 mm, "Medium" type - crown 11 mm, root 14 mm, and buccolingual cervical diameter 6.5 mm, and "Slim" type - crown 9.5 mm, root 15 mm, and buccolingual cervical diameter 5.5 mm. Each model received an anatomical castable post-and-core or glass-fiber post with resin composite core and three ferrule heights (nonexistent, 1 mm, and 2 mm). Then, a load of 14 N was applied at the cingulum with a 45° slope to the long axis of the tooth. The Maximum Principal Stress and the Minimum Principal Stress were calculated in the root dentin, crown, and core. RESULTS: Higher tensile and compression stress values were observed in root dentin using the metallic post compared to the fiber post, being higher in the slim type maxillary central incisor than in the medium and fat types. Concerning the three anatomical types of maxillary central incisors, the slim type without ferrule height in mm presented the highest tensile stress in the dentin, for both types of metal and fiber posts. CONCLUSION: Post system and tooth morphology were able to modify the biomechanical response of restored endodontically-treated incisors, showing the importance of personalized dental treatment for each case.

3.
J Prosthodont ; 2024 May 12.
Article in English | MEDLINE | ID: mdl-38734932

ABSTRACT

PURPOSE: To evaluate the fracture resistance of zirconia overlays, considering various preparation designs and the presence of endodontic access. MATERIALS AND METHODS: Ninety translucent zirconia (5Y-PSZ) overlay restorations were divided into six groups (n = 15/group) based on different preparation designs, with and without endodontic access: chamfer margin 4 mm above the gingival level without (group 1) and with endodontic access (group 2); margin 2 mm above the gingival level without (group 3) and with endodontic access (group 4); overlay with no chamfer margin without (group 5) and with endodontic access (group 6). Restorations were bonded to mandibular first molar resin dies, and the groups with endodontic access were sealed with flowable resin composite. All restorations underwent 100,000 cycles of thermal cycling between 5°C and 55°C, followed by loading until fracture. Maximum load and fracture resistance were recorded. ANOVA with Tukey post-hoc tests were used for statistical comparison (α < 0.05). RESULTS: Fracture resistance significantly varied among overlay designs with and without endodontic access (p < 0.001), except for the no-margin overlays (groups 5 and 6). Overlays with a 2 mm margin above the gingival margin with endodontic access (group 4) exhibited significantly higher fracture resistance compared to both the 4-mm supragingival (group 2) and no-margin (group 6) designs, even when compared to their respective intact groups (groups 1 and 5). There were no significant differences between the no-margin and 4-mm supragingival overlays. CONCLUSION: The more extensive zirconia overlay for mandibular molars is the first choice since the 2 mm margin above the gingival level design withstood considerable loads even after undergoing endodontic access. A no-margin overlay is preferred over the 4-mm supragingival design as it preserves more tooth structure and there was no outcome difference, irrespective of endodontic access. Caution is warranted in interpreting these findings due to the in vitro nature of the study.

4.
Int J Paediatr Dent ; 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627936

ABSTRACT

BACKGROUND: Several clinical and individual factors may play a role in the survival rate of dental restorations, such as characteristics related to the child's age and oral hygiene, and factors associated with the tooth, such as the type of material and number of surfaces to be restored. AIM: To analyse the survival rate of adhesive restorations on primary teeth and factors associated with restoration survival. DESIGN: The study included dental records of children aged 3-12 years having received adhesive restorations on primary teeth at a Brazilian dental school between 2009 and 2019. A Kaplan-Meier survival curve was used to plot survival rates using the log-rank test. A multivariate Cox regression model was run to identify individual and dental factors associated with restoration failure. RESULTS: The sample comprised 269 restored teeth in 111 children. Survival curves were similar for all materials (p = .20) and types of isolation (p = .05). The annual failure rate was 3.60% for glass ionomer cement, 1.23% for resin-modified glass ionomer cement and 0.40% for composite resin. The following variables were associated with more failures: Class II restoration compared with Class I (HR = 1.96; 95%CI: 1.28-2.99, p < .001), proportion of decayed teeth (HR = 11.89; 95%CI: 2.80-50.57, p < .001) and child's age (HR = 1.17; 95%CI: 1.06-1.29, p < .001). CONCLUSION: The different materials and types of isolation had similar survival rates. Children with more decayed teeth have an increased risk of restoration failure.

5.
Clin Cosmet Investig Dent ; 16: 101-114, 2024.
Article in English | MEDLINE | ID: mdl-38665472

ABSTRACT

Purpose: The aim of this work is to conduct a literature review to highlight all the parameters involved in sub-prosthetic radicular fractures of teeth supported by metallic dental core. Materials and Methods: The following research was performed among published studies over the last 10 years in two PubMed/Medline and Scopus and supplemented by manual searching within the bibliographies. The search was restricted to publications in English and French. Results: Out of the 1464 articles initially identified, 18 studies met our inclusion criteria and were subsequently included in the literature review. These consisted of eight Finite Element Analysis Studies, two Retrospective Studies and one Randomized Controlled Trial. The results of this review show that radicular fractures are influenced by several variables, including predisposition, with maxillary premolars and mandibular molars being the most commonly affected teeth. Intracanal preparation can induce crack formation, leading to localized high stress concentrations. Increased ferrule height to 2 mm significantly enhances dental fracture resistance. Using high modulus of elasticity alloys results in nearly complete stress transmission to dentin due to their limited deformability and absorption capacity. The highest fracture resistance is achieved when posts are sealed using resin-modified glass-ionomer cement. Longer posts may be preferable to prevent vertical fractures. Additionally, occlusal factors, through repetitive stresses, contribute to crack propagation from surface defects, a phenomenon termed fatigue fracture. Conclusion: These findings have significant implications. Practitioners should be aware of the predisposition of certain teeth, the importance of preserving the ferrule effect, the choice of root post materials, post Cement Material and the role of occlusal forces in managing and preventing vertical root fractures.

6.
J Dent ; 145: 105009, 2024 06.
Article in English | MEDLINE | ID: mdl-38643866

ABSTRACT

OBJECTIVES: Resin-based composites (RBCs) evolved into favoured materials for teeth restorations, marking a significant change in dental practice. Despite many advantages, RBCs exhibit various limitations in their physical and chemical properties. Therefore, we assessed the dentists' awareness of possible complications after direct composite restorations and their opinions about this material. METHODS: The online questionnaire was created in English in May 2023. A 16-item survey was dedicated to general dentists and specialists. The first section included four questions related to demographic characteristics. The second section comprised twelve questions and focused on awareness of potential side effects of composite restorations, the most crucial advantages and disadvantages of composite resins, and the frequency of experienced clinical complications after the application of composite materials. RESULTS: A total of 1830 dentists from 13 countries took part in the survey. Dentists most often declared awareness of low adhesion to the dentine (77.5 %) and, most rarely, solubility in oral fluids (42.6 %). Aesthetics was identified as the main advantage of composite fillings (79 %), followed by the possibility of repair (59 %) and adhesion to enamel (57 %). Polymerisation shrinkage was a major disadvantage for most countries (70 % overall). Analysing the declared potential clinical complications for all countries, statistically significant findings were obtained for marginal discolouration (OR=2.982, 95 % CI: 1.321-6.730, p-value=0.009) and borderline significance for secondary caries (OR=1.814, 95 % CI: 0.964-3.415, p-value=0.065). CONCLUSIONS: Dentists value aesthetics and repairability but are aware of shrinkage and experience discolouration. The issue of toxicity and solubility seems to be the least known to dentists. CLINICAL SIGNIFICANCE: Dentists should use RBCs with critical caution due to possible side effects. Despite the undoubted aesthetics of direct composite restorations, it is necessary to remember potential clinical complications such as marginal discolouration or secondary caries.


Subject(s)
Composite Resins , Dental Restoration, Permanent , Dentists , Composite Resins/adverse effects , Composite Resins/chemistry , Humans , Dental Restoration, Permanent/adverse effects , Dentists/psychology , Surveys and Questionnaires , Female , Male , Dental Materials/adverse effects , Dental Materials/chemistry , Adult , Esthetics, Dental , Middle Aged , Polymerization , Dental Restoration Repair
7.
Adv Clin Exp Med ; 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38439611

ABSTRACT

Ceramic is a commonly used material in dentistry for reconstructing missing teeth or their tissues due to its biocompatibility, durability and excellent esthetic properties. Despite these advantages, the ceramic restoration damage remains a significant clinical problem. Its causes can be divided into clinical and laboratory factors. The most known include uneven occlusion, improper preparation, trauma, or parafunctions. This study focuses on characterizing less known laboratory causes of ceramic restoration damage. We reviewed the current literature available in the PubMed and Scopus databases. On the basis of 63 selected studies, 3 basic causes of damage were identified: excessive stresses between the framework and ceramic veneering, poor quality of the connection between the facing layer and the substructure, and defects resulting from the nature of the ceramic material such as defects in the ceramic layer, brittleness and lack of flexibility. The stages of the manufacturing process of various permanent ceramic restorations were presented. By controlling these procedures, we can eliminate the errors, resulting in long-term effective functioning of the ceramic restorations.

8.
BMC Oral Health ; 24(1): 389, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38532413

ABSTRACT

BACKGROUND: While the concept of angled screw channels has gained popularity, there remains a scarcity of research concerning the torque loss and fracture strength of monolithic zirconia restorations with various screw channel angulations when exposed to thermomechanical cycling. This in-vitro study aimed to evaluate the reverse torque value and fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations with angulated screw channels after thermomechanical cycling. METHODS: One-piece monolithic zirconia restorations, with angulated screw channels set at 0°, 15°, and 25° (n = 6 per angulation) were fabricated and bonded to titanium inserts using a dual-cure adhesive resin cement. These assemblies were then screwed to implant fixtures embedded in acrylic resin using an omnigrip screwdriver, and reverse torque values were recorded before and after thermomechanical cycles. Additionally, fracture modes were assessed subsequent to the application of compressive load. One-way ANOVA and Bonferroni post hoc test were used to compare the groups (α = 0.05). RESULTS: The study groups were significantly different regarding the fracture resistance (P = 0.0015), but only insignificantly different in the mean percentage torque loss (P = 0.4400). Specifically, the fracture resistance of the 15° group was insignificantly higher compared to the 0° group (P = 0.9037), but significantly higher compared to the 25° group (P = 0.0051). Furthermore, the fracture resistance of the 0° group was significantly higher than that of the 25° group (P = 0.0114). CONCLUSIONS: One-piece hybrid monolithic zirconia restorations with angulated screw channels can be considered an acceptable choice for angulated implants in esthetic areas, providing satisfactory fracture strength and torque loss.


Subject(s)
Crowns , Dental Cements , Zirconium , Humans , Torque , Materials Testing , Dental Abutments , Titanium , Bone Screws , Dental Stress Analysis , Dental Restoration Failure
9.
J Mech Behav Biomed Mater ; 151: 106395, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38244420

ABSTRACT

OBJECTIVES: To assess the mechanical durability of monolithic zirconia implant-supported fixed dental prostheses (iFDP) design on one implant, with a distal and a mesial extension cantilever bonded to a titanium base compared to established designs on two implants. MATERIALS AND METHODS: Roxolid Tissue level (TL), and tissue level x (TLX) implants were used to manufacture screw-retained 3-unit iFDPs (n = 60, n = 10 per group), with following configurations (X: Cantilever; I: Implant, T: Test group, C: Control group): T1: X-I-X (TL); T2: X-I-X (TLX); T3: I-I-X (TL); T4: I-I-X (TLX); C1: I-X-I (TL); C2: I-X-I (TLX). The iFDPs were thermomechanically aged and subsequently loaded until fracture using a universal testing machine. The failure load at first crack (Finitial) and at catastrophic fracture (Fmax) were measured and statistical evaluation was performed using two-way ANOVA and Tukey's post-hoc tests. RESULTS: The mean values ranged between 190 ± 73 and 510 ± 459 N for Finitial groups, and between 468 ± 76 and 1579 ± 249 N for Fmax, respectively. Regarding Finitial, neither the implant type, nor the iFDP configuration significantly influenced measured failure loads (all p > 0.05). The choice of implant type did not show any significant effect (p > 0.05), while reconstruction design significantly affected Fmax data (I-I-Xa < X-I-Xb < I-X-Ic) (p < 0.05). The mesial and distal extension groups (X-I-X) showed fractures only at the cantilever extension site, while the distal extension group (I-I-X) showed one abutment and one connector fracture at the implant/reconstruction interface. CONCLUSION: Results suggest that iFDPs with I-X-I design can be recommended regardless of tested implant type followed by the mesial and distal extension design on one implant abutment (X-I-X).


Subject(s)
Dental Implants , Dental Prosthesis , Zirconium , Weight-Bearing , Bone Screws , Analysis of Variance , Titanium , Dental Restoration Failure , Dental Stress Analysis , Materials Testing , Crowns
10.
Int J Oral Maxillofac Surg ; 53(5): 430-435, 2024 May.
Article in English | MEDLINE | ID: mdl-38061953

ABSTRACT

The aim of this study was to assess whether immediate bone reconstruction after removal of a fractured dental implant in the posterior mandible provides a sound base for implant replacement, with a favourable treatment outcome and high patient satisfaction. Eight consecutive patients with a fractured implant neck were included. The implant was removed via osteotomy, following which the site was immediately repaired with a mixture of autogenous bone and bone substitute. After a 4-month healing period, sufficient bone and favourable soft tissue conditions were present, allowing implant placement with adequate primary stability. After a further 3 months, the implants were restored with an all-ceramic restoration. Patient satisfaction, the aesthetic outcome, complications, and postoperative morbidity were assessed using standardized clinical and radiographic examinations up to 5 years after crown placement. No implant failures were observed during the follow-up. Plaque accumulation, the presence of calculus, bleeding tendency, and peri-implant inflammation indices were low, indicating healthy peri-implant conditions. The mean marginal bone level change at the 5-year follow-up was - 0.17 ± 0.46 mm. All patients reported a high level of satisfaction (mean overall score 9.3 ± 0.5). In conclusion, immediate reconstruction of the hard tissue after removal of a fractured dental implant is a viable treatment option. This approach facilitates rehabilitation, reduces morbidity, and leads to favourable aesthetic outcomes.


Subject(s)
Alveolar Bone Loss , Dental Implants, Single-Tooth , Dental Implants , Immediate Dental Implant Loading , Humans , Follow-Up Studies , Alveolar Bone Loss/surgery , Treatment Outcome , Dental Implantation, Endosseous/adverse effects , Mandible/surgery , Dental Prosthesis, Implant-Supported , Dental Restoration Failure
11.
Braz. oral res. (Online) ; 38: e003, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1528147

ABSTRACT

Abstract Resin composites containing surface pre-reacted glass (S-PRG) have been introduced to reduce demineralization and improve remineralization of the tooth structure. However, water diffusion within the material is necessary for its action, which can impair its overall physicomechanical properties over time, including color stability. This study aimed to evaluate the color stability and related degree of conversion (DC) of four resin composites. Discs (6 x 4 mm, n = 5/group) of microhybrid (MH), nanofilled (NF), nanohybrid (NH), and S-PRG-based nanohybrid (S-PRG-NH) composites with two opacities (A2/A2E and A2O/A2D) were prepared. Color (CIELab and CIEDE2000) was evaluated with a spectrophotometer after aging in grape juice (2 x 10 min/10mL/7days). The DC was analyzed by using Fourier transform infrared spectroscopy before and after light-curing. Data were statistically analyzed by using two-way analysis of variance and post-hoc least significant difference tests (p<0.05). In the color stability analysis, the interaction between filler type and opacity was significant (CIELab, p = 0.0015; CIEDE2000, p = 0.0026). NH presented the highest color stability, which did not differ from that of MH. The greatest color alteration was observed for S-PRG-NH. S-PRG fillers also influenced DC (p < 0.05). The nanohybrid resin composite presented favorable overall performance, which is likely related to its more stable organic content. Notwithstanding the benefits of using S-PRG-based nanohybrid resins, mostly in aesthetic procedures, professionals should consider the susceptibility of such resins to color alteration, probably due to the water-based bioactive mechanism of action.

12.
Diagnostics (Basel) ; 13(12)2023 Jun 20.
Article in English | MEDLINE | ID: mdl-37371017

ABSTRACT

Despite the widespread use of titanium implants in orthopedic and dental surgeries, concerns have recently emerged regarding potential deformations and fractures after osseointegration. In a recent clinical case, a titanium implant fractured after successful osseointegration. This fracture occurred despite the absence of any significant trauma or excessive external force applied to the area. The fracture was attributed to a combination of factors, including abutment design flaws, material fatigue, and biomechanical stress imposed on the implant during functional loading. This raises concerns about the long-term durability and reliability of titanium implants, particularly in high-stress areas such as the posterior region or weight-bearing bones. An image was made with scanning electron microscopy showing the fracture region near the prosthetic platform and highlighting the knowledge that despite their ductility, titanium implants can fracture.

13.
Biomedicines ; 11(5)2023 Apr 23.
Article in English | MEDLINE | ID: mdl-37238927

ABSTRACT

Damage in the bonding interface is a significant factor that leads to premature failure of dental bonded restorations. The imperfectly bonded dentin-adhesive interface is susceptible to hydrolytic degradation and bacterial and enzyme attack, severely jeopardizing restorations' longevity. Developing caries around previously made restorations, also called "recurrent or secondary caries," is a significant health problem. The replacement of restorations is the most prevailing treatment in dental clinics, leading to the so-called "tooth death spiral". In other words, every time a restoration is replaced, more tooth tissue is removed, increasing the size of the restorations until the tooth is eventually lost. This process leads to high financial costs and detriment to patients' quality of life. Since the complexity of the oral cavity makes prevention a challenging task, novel strategies in Dental Materials and Operative fields are required. This article briefly overviews the physiological dentin substrate, features of dentin bonding, challenges and clinical relevance. We discussed the anatomy of the dental bonding interface, aspects of the degradation at the resin-dentin interface, extrinsic and intrinsic factors affecting dental bonding longevity, perspectives on resin and collagen degradation and how these subjects are connected. In this narrative review, we also outlined the recent progress in overcoming dental bonding challenges through bioinspiration, nanotechnology and advanced techniques to reduce degradation and improve dental bonding longevity.

14.
Clin Oral Investig ; 27(8): 4379-4387, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37162571

ABSTRACT

OBJECTIVES: This study aims to investigate the load-to-fracture of procedures changing crown-to-root ratio (RCRR) aimed to restore severely damaged upper central incisors to avoid tooth extraction compared to implant placement. There is no evidence on load capability after apical root resection (AR), orthodontic extrusion (OE), and surgical crown lengthening (SCL) in respect to RCRR, respectively. MATERIAL AND METHODS: Human maxillary central incisors were endodontically treated, decoronated, and divided into 4 groups (n = 48). The following specimen preparation was performed: (I) adhesive core-and-post build-up (control), (II) as (I) and 2 mm apical root resection (AR), (III) before adhesive core-and-post build-up teeth were shortened 2 mm coronally (OE) (IV) as (I), but specimens were embedded 4 mm instead of 2 mm below the CEJ (SCL), group (V) implant-borne restoration with individual all-ceramic abutments (n = 12; ∅4.1/l = 12 mm) (IBR). All specimens received all-ceramic crowns, thermo-mechanical (TML), and subsequent linear loading (LL) until failure. RCRR were calculated and log-rank, Kruskal-Wallis, Mann-Whitney U, ANOVA, and chi-square tests applied (p = 0.05). RESULTS: Fracture loads after subsequent LL differed significantly (p = 0.001) between groups, while implants showed the highest values. Fmax median (min/max) were as follows: (I) 252 (204/542), (II) 293 (243/443), (III) 253 (183/371), (IV) 195 (140/274), and (V) 446 (370/539). Pair-wise comparison showed significant differences (p = 0.001) between group I/IV and group V, I, and IV (p = 0.045), II and IV (p = 0.001), and III compared to IV (p = 0.033), respectively. RCRR below 1 significantly increased load capability compared to RCRR = 1. CONCLUSIONS: OE appears to preferably ensure biomechanical stability of teeth that are endodontically treated and receive core-and-post and crown placement compared to SCL. AR has no adverse biomechanical impact. RCRR < 1 is biomechanically beneficial. CLINICAL RELEVANCE: For endodontically treated and restored teeth, orthodontic extrusion should be preferred compared to surgical crown lengthening prior single-crown restoration. As orthodontic extrusion, apical root resection has no adverse effect on load capability. Single-crown implant-borne restorations are most load capable.


Subject(s)
Post and Core Technique , Tooth Fractures , Tooth, Nonvital , Humans , Orthodontic Extrusion/adverse effects , Crown Lengthening/adverse effects , Composite Resins , Tooth, Nonvital/surgery , Crowns , Tooth Fractures/surgery , Dental Stress Analysis , Dental Restoration Failure
15.
São José dos Campos; s.n; 2023. 57 p. ilus, tab.
Thesis in Portuguese | BBO - Dentistry | ID: biblio-1452548

ABSTRACT

Objetivos: Avaliar as propriedades mecânicas, atividade antimicrobiana e citocompatibilidade da zircônia translúcida 5Y-PSZ revestida por vidros experimentais contendo boro e prata. Métodos: Discos 5Y-PSZ (KATANA UTML™, Kuraray Noritake) foram processados e divididos em quatro grupos: polido, sem nenhum revestimento (Controle), aplicação de glaze comercial (Glaze) e vidros experimentais contendo prata (AgCoat) e boro (BCoat). As amostras foram submetidas aos testes de dureza Vickers, testes de flexão biaxial, análise fractográfica e rugosidade através de perfilometria óptica. O potencial antimicrobiano foi caracterizado usando biofilmes de espécie única de Streptococcus mutans e Candida albicans. Foi realizada a quantificação de unidades viáveis formadoras de colônias (UFC), atividade metabólica (CV), ensaios de matriz polissacarídica extracelular (EPS) e biovolume. Biofilmes foram visualizados por microscópio eletrônico de varredura (MEV) e microscopia confocal de varredura a laser (CLSM). A citocompatibilidade foi determinada usando os testes WST-1 e LIVE&DEAD usando células-tronco do ligamento periodontal (PDLSCs) por 24 h. Todas as caracterizações biológicas foram realizadas em triplicatas técnicas e biológicas usando amostras independentes. As análises estatísticas foram realizadas por ANOVA de uma via, teste de Tukey, análise de Weibull e análise de correlação de Pearson. Resultados: BCoat, AgCoat e Glaze alcançaram dureza semelhante, que foi menor que o Controle. BCoat teve a maior resistência à flexão e parâmetros de Weibull (m = 11,5, sF 625 MPa, s0 620) seguido por AgCoat (m = 5,3; sF 464 MPa, s0 478 MPa). BCoat diminuiu significativamente a formação de biofilmes, conforme mostrado pela menor UFC (5,94 log-UFC/mm2) e atividade metabólica (0,17 a.u.) em comparação com os outros grupos (AgCoat: 6,44 log-UFC/mm2, 0,89 a.u.; Glaze: 6,81 log UFC/mm2, 1,21 a.u.; Controle: 6,82 logUFC/mm2, 1,25 a.u.). BCoat e AgCoat apresentaram os menores valores de EPS (0,11 a.u.), seguidos por Glaze e Controle (0,13 a.u.; 0,14 a.u., respectivamente). MEV e CLSM revelaram que os biofilmes no BCoat eram finos, esparsos, com menor biovolume, enquanto os outros grupos produziram biofilmes robustos com maior biovolume. Os ensaios de viabilidade celular não mostraram toxicidade para PDLSCs para todos os grupos. Conclusão: 5Y-PSZ revestida por vidro experimental contendo boro surge como uma estratégia potencial para melhorar as propriedades mecânicas e antimicrobianas do material (AU).


Objectives: To evaluate the mechanical and antimicrobial properties of boroncontaining coating on translucent zirconia (5Y-PSZ). Methods: 5Y-PSZ discs (Control) were coated with a glaze (Glaze), silver- (AgCoat), or boron-containing (BCoat) glasses. The coatings' antimicrobial potential was characterized using S. mutans and C. albicans biofilms through viable colony-forming units (CFU), metabolic activity (CV), and the extracellular polysaccharide matrix (EPS). Biofilm architectures were imaged under scanning electron and confocal laser scanning microscopies (SEM and CLSM). Cytocompatibility was determined at 24 h via WST-1 and LIVE&DEAD assays using periodontal ligament stem cells (PDLSCs). The coatings' effects on mechanical properties were characterized by Vickers hardness, biaxial bending tests, and fractography analysis. Statistical analyses were performed via one-way ANOVA, Tukey's tests, Weibull analysis, and Pearson's correlation analysis. Results: BCoat significantly decreased biofilm formation, having the lowest CFU and metabolic activity compared with the other groups. BCoat and AgCoat presented the lowest EPS, followed by Glaze and Control. SEM and CLSM images revealed that the biofilms on BCoat were thin and sparse, with lower biovolume. In contrast, the other groups all yielded similarly robust biofilms with higher biovolume without compromising PDLSC viability. BCoat, AgCoat, and Glaze also presented similar hardness significantly lower than Control. BCoat had the highest flexural strength, characteristic strength and Weibull parameters (sF : 625 MPa; s0: 620 MPa; m = 11.5), followed by AgCoat (sF : 464 MPa; s0: 478 MPa; m = 5.3). Significance: BCoat is a cytocompatible glass with promising antimicrobial properties that can improve the mechanisms and reliability of 5Y-PSZ (AU).


Subject(s)
Dental Restoration Failure , Dental Plaque , Materials Science , Flexural Strength
16.
J. appl. oral sci ; 31: e20220323, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1421903

ABSTRACT

Abstract Objectives This is a double-blind, split-mouth, randomized clinical study that aims to evaluate the influence of bulk-fill composite packaging presented in syringes (BSy) and capsules (BCa), and the effect of selective enamel etching (SEE) on the clinical performance of class I and II bulk-fill resin composite restorations after 24 months. Methodology A total of 295 class I or class II restorations were performed on 70 patients. One universal adhesive was applied in all restorations. SEE was used in 148 restorations and self-etching mode (SET) in 147 restorations. After the adhesive application, cavities were restored with Filtek Bulk-fill Posterior Restorative in syringes (BSy), Filtek One Bulk-fill in capsules (BCa), or Filtek Supreme Ultra in syringes with the incremental technique (In). All restorations were evaluated using the FDI criteria after one week and after six, 12, and 24 months. Kaplan-Meier survival analysis and Pearson's Chi-square test were used (α=0.05) for statistical analysis. Results After 24 months, 62 patients were evaluated and four restorations were lost due to fracture (one for SEEBSy, two for SEEIn, and one for SETIn). No significant differences in the fracture and retention rate were found between groups (p>0.05). SEE showed significantly fewer marginal adaptation defects than SET (p<0.05). BCa and BSy groups showed fewer marginal discrepancies compared to In (p<0.05). Restorations performed with BCa showed less color mismatch than BSy or In (p<0.05). Conclusion Although all restorations exhibited satisfactory clinical performance after 24 months of clinical service, the clinical behavior of class I and II restorations' improved when performed with a bulk-fill composite in capsules, mainly when associated with a universal adhesive applied with SEE.

17.
Materials (Basel) ; 15(23)2022 Nov 28.
Article in English | MEDLINE | ID: mdl-36499960

ABSTRACT

No evidence-based prosthetic treatment concept for 3-unit fixed-dental-prostheses (FDPs) on ceramic implants is currently available. Therefore, the aim of this in vitro study was to investigate the failure load and fatigue behavior of monolithic and bi-layer zirconia FDPs supported by one-piece ceramic implants. Eighty 3-unit FDPs supported by 160 zirconia-implants (ceramic.implant; vitaclinical) were divided into 4 groups (n = 20 each): Group Z-HT: 3Y-TZP monolithic-zirconia (Vita-YZ-HT); Group Z-ST: 4Y-TZP monolithic-zirconia (Vita-YZ-ST); Group FL: 3Y-TZP zirconia (Vita-YZ-HT) with facial-veneer (Vita-VM9); Group RL (Rapid-layer): PICN "table-top" (Vita-Enamic), 3Y-TZP-framework (Vita-YZ-HT). Half of the test samples (n = 10/group) were fatigued in a mouth-motion chewing-simulator (F = 98 N, 1.2 million-cycles) with simultaneous thermocycling (5−55 °C). All specimens (fatigued and non-fatigued) were afterwards exposed to single-load-to-failure-testing (Z010, Zwick). Statistical analysis was performed using ANOVA, Tukey's post-hoc tests and two-sample t-tests (p < 0.05, Bonferroni-corrected where appropriate). All specimens withstood fatigue application. While the effect of fatigue was not significant in any group (p = 0.714), the choice of material had a significant effect (p < 0.001). Material FL recorded the highest failure loads, followed by Z-ST, Z-HT and RL, both with and without fatigue application. Taken together, all tested FDP material combinations survived chewing forces that exceeded physiological levels. Bi-Layer FL and monolithic Z-ST showed the highest resilience and might serve as reliable prosthetic reconstruction concepts for 3-unit FDPs on ceramic implants.

18.
Braz. j. oral sci ; 21: e225991, jan.-dez. 2022. tab
Article in English | LILACS, BBO - Dentistry | ID: biblio-1354992

ABSTRACT

Aim: A retrospective, cross-sectional study was carried out to evaluate the performance of resin composite restorations placed by undergraduate dental students with 1 to 15 years of placement based on dental records. Methods: Four calibrated operators evaluated 498 restorations (anterior and posterior) of 120 patients according to Ryge's validated criteria (USPHS). Results: The criteria that showed the smallest changes between the types of failures were color matching, marginal discoloration and surface texture. Regarding the longevity, the surface texture showed an increase in the frequency of failures from the second time interval (3.1 to 6 years). Higher prevalence of failure was found in class II and III restorations, with secondary caries being the main reason. No significant differences were found for anatomic form, marginal adaptation, and color matching. Class V restorations showed a higher fracture rate with total displacement of the restoration, with no increase in the frequency of fracture over time. Conclusion: High rate of restoration failure was observed, possibly due to the lack of experience and skills of the students. This outcome highlight the need for continuous revision and improvements of teaching practice regarding the development of clinical competences and skills by dental students


Subject(s)
Humans , Male , Female , Composite Resins , Dental Restoration Failure , Dental Restoration, Permanent
19.
Braz. j. oral sci ; 21: e226999, jan.-dez. 2022. ilus
Article in English | LILACS, BBO - Dentistry | ID: biblio-1392965

ABSTRACT

Background: Tooth extraction socket in the aesthetic area is a major indication for immediate implant placement greatly improving patient satisfaction and preserving the alveolar ridge. However, the effect of non-axial force on the peri-implant bone with subsequent early implant failure remains unclear. Objective:Evaluate the prognosis of tilted implants immediately placed and restored with angled abutments in comparison to straight implants restored with straight abutments in the esthetic area (anterior or premolars) using computer-aided surgical guides. Material and methods: Badly decayed non-restorable teeth in the aesthetic zone (anterior or premolars) were extracted atraumatically. Immediately after guided implant insertion, the abutments were adjusted and placed according to the allocation group (0, 15, or 25-degree angle) then a temporary crown was performed out of occlusion in centric and eccentric relation. Early implant failure was assessed at three and six months. Results:There was no statistically significant difference between the two groups (P=0.305). Straight and angled abutment groups showed 6 (14.3%) and 8 (20%) failed cases, respectively. The post-hoc subgroup analysis showed no statistically significant difference between angle 15 and angle 25 degree groups where (P=0.686) or between Anterior and Premolar groups (P=0.853). Conclusion: There was no statistically significant difference in the failure rate when comparing angled to straight immediately placed & restored implants. This applies to both anterior and premolar implants


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Prognosis , Tooth Extraction , Weight-Bearing , Dental Restoration Failure , Dental Implantation , Immediate Dental Implant Loading
20.
J Conserv Dent ; 25(4): 347-355, 2022.
Article in English | MEDLINE | ID: mdl-36187858

ABSTRACT

Background: Advances in adhesive technologies and escalation in esthetic demands have increased indications for tooth-colored, partial coverage restorations. Recently, material knowledge has evolved, new materials have been developed, and no systematic review has answered the question posed by practitioners: Is the clinical efficacy of resin or ceramic better, for inlay, onlay, and overlay in the long run? Aim: The aim of this systematic review and meta-analysis was to evaluate the clinical performance of ceramic and resin inlays, onlays, and overlays and to identify the complication types associated with the main clinical outcomes. Materials and Methods: Two reviewers (VN and AJ) searched PubMed, Embase, and Cochrane Central registry of controlled trials for published articles between 1983 and 2020 conforming to Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines for systematic reviews. Only clinical studies which met the following criteria were included (1) studies regarding ceramic and resin inlays, onlays, and overlays were included; (2) randomized controlled trials, retrospective or prospective studies conducted in humans; (3) studies with a dropout rate <50% 4) studies with a follow-up higher than 5 years. Results: Of 1718 articles, 21 articles were selected. At 5 years, the estimated survival rates for resin (n = 129) was 86%, feldspathic porcelain (n = 1048) was 90%, and glass ceramic (n = 2218) was 92%; at 10 years, the survival of resin was 75% (n = 115), feldspathic porcelain was 91% (n = 1829), and glass ceramic was 89% (n = 1075). Conclusion: The meta-regression indicated that ceramic partial coverage restorations (feldspathic porcelain and glass-ceramic) outperformed resin partial coverage restorations both at 5-year and 10-year follow-up. When compared between ceramic types, glass ceramics outperformed feldspathic porcelain at 5 years' follow-up and feldspathic porcelain outperformed glass ceramics at 10 years' follow-up. The failures were mostly due to fractures (6.2%), endodontic problems (3%), secondary caries (1.7%), and debonding which was 0.9%.