Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 740
Filter
1.
Sci Rep ; 14(1): 14989, 2024 07 01.
Article in English | MEDLINE | ID: mdl-38951530

ABSTRACT

Digital positron emission tomography/computed tomography (PET/CT) has shown enhanced sensitivity and spatial resolution compared with analog PET/CT. The present study compared the diagnostic performance of digital and analog PET/CT with [68Ga]Ga-PSMA-11 in prostate cancer patients who experienced biochemical recurrence (BCR) after prostatectomy. Forty prostate cancer patients who experienced BCR, defined as serum prostate-specific antigen (PSA) concentrations exceeding 0.2 ng/mL after prostatectomy, were prospectively recruited. These patients were stratified into three groups based on their serum PSA levels. [68Ga]Ga-PSMA-11 was injected into each patient, and images were acquired using both analog and digital PET/CT scanners. Analog and digital PET/CT showed comparable lesion detection rate (71.8% vs. 74.4%), sensitivity (85.0% vs. 90.0%), and positive predictive value (PPV, 100.0% vs. 100.0%). However, digital PET/CT detected more lesions (139 vs. 111) and had higher maximum standardized uptake values (SUVmax, 14.3 vs. 10.3) and higher kappa index (0.657 vs. 0.502) than analog PET/CT, regardless of serum PSA levels. On both analog and digital PET/CT, lesion detection rates and interrater agreement increased with increasing serum PSA levels. Compared with analog PET/CT, digital PET/CT detected more lesions with a higher SUVmax and better interrater agreement in prostate cancer patients who experienced BCR after prostatectomy.


Subject(s)
Gallium Isotopes , Gallium Radioisotopes , Neoplasm Recurrence, Local , Positron Emission Tomography Computed Tomography , Prostate-Specific Antigen , Prostatectomy , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/surgery , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/blood , Positron Emission Tomography Computed Tomography/methods , Aged , Prospective Studies , Middle Aged , Neoplasm Recurrence, Local/diagnostic imaging , Prostate-Specific Antigen/blood , Edetic Acid/analogs & derivatives , Oligopeptides
2.
J Gynecol Obstet Hum Reprod ; 53(9): 102819, 2024 Jun 29.
Article in English | MEDLINE | ID: mdl-38950735

ABSTRACT

The main objective of this study was to review and perform a meta-analysis of current literature on the use of indocyanine green for sentinel lymph node detection in pelvic gynecologic cancer. We included all studies focusing on indications and procedures associated with the use of ICG in gynecologic surgery and available on the Medline and Pubmed database. For the meta-analysis, random effect models were used for estimation of the 95 % detection rate and 95 % confidence interval, and stratified analyses by cancer type, concentration and localization of injection were performed. A total of 147 articles were included, of which 91 were studied in a meta-analysis. Results concerning detection rate by indocyanine green injection site were found to be 95.1 % and 97.3 % respectively for intracervical injection in 2 or 4 quadrants, and 77.0 % and 94.8 % for hysteroscopic and intradermal injection respectively. Results concerning detection rate by cancer type were 95.8 %, 95.2 %, 94.7 % and 95.7 % respectively for cervical, endometrial, vulvar and endometrial/cervical cancers. Finally, the results concerning detection rate by indocyanine green concentration were 91.2 %, 95.7 %, 96.7 % and 97.7 % for concentrations of <1.25 mg/ml, 1.25 mg/ml, 2.5 mg/ml and 5 mg/ml respectively. In conclusion, indocyanine green is shown to allow highlighting of sentinel lymph nodes with good reliability with an overall indocyanine green detection rate of 95.5 %. Our literature review revealed that indocyanine green feasibility has also been demonstrated in several surgical contexts, notably for reconstructive surgery and detection of endometriosis.

3.
Article in English | MEDLINE | ID: mdl-38976035

ABSTRACT

PURPOSE: To explore the feasibility of imaging amino-acid transport and PSMA molecular pathways in the detection of metastatic breast invasive lobular carcinoma (ILC) and if there is superior detection compared to standard-of-care imaging [computed tomography (CT)/bone scan, or 18F-FDG positron-emission-tomography (PET)-CT]. METHODS: 20 women with de-novo or suspected metastatic ILC underwent two PET-CT scans with 18F-fluciclovine and 68Ga-PSMA-11 on separate days. Uptake per patient and in 3 regions per patient - ipsilateral axillary lymph node (LN), extra-axillary LN (ipsilateral supraclavicular or internal mammary), or distant sites of disease - was compared to standard-of-care imaging (CT/bone scan in 13 patients and 18F-FDG PET-CT in 7 patients). Results were correlated to a composite standard of truth. Confirmed detection rate (cDR) was compared using McNemar's test. Mean SUVmax of 18F-fluciclovine and 68Ga-PSMA-11 in the most avid lesion for each true positive metastatic region and intact primary lesion were compared by t-test. RESULTS: The cDR for standard-of-care imaging was 5/20 patients in 5/60 regions. 68Ga-PSMA-11 PET-CT detected metastasis in 7/20 patients in 7/60 regions. 18F-fluciclovine PET-CT detected metastasis in 9/20 patients in 12/60 regions. The cDR for 18F-fluciclovine PET-CT was significantly higher versus standard-of-care imaging on the patient and combined region levels, while there were no significant differences between 68Ga-PSMA-11 and standard-of care imaging. 18F-fluciclovine cDR was also significantly higher than 68Ga-PSMA-11 on the combined region level. Mean SUVmax for true positive metastatic and primary lesions with 18F-fluciclovine (n = 18) was significantly greater than for 68Ga-PSMA-11 (n = 11) [5.5 ± 1.8 versus 3.5 ± 2.7 respectively, p = 0.021]. CONCLUSION: In this exploratory trial, 18F-fluciclovine PET-CT has a significantly higher cDR for ILC metastases compared to standard-of-care imaging and to 68Ga-PSMA-11. Mean SUVmax for true positive malignancy was significantly higher with 18F-fluciclovine than for 68Ga-PSMA-11. Exploratory data from this trial suggests that molecular imaging of amino acid metabolism in patients with ILC deserves further study. CLINICAL TRIAL REGISTRATION: Early phase (I-II) clinical trial (NCT04750473) funded by the National Institutes of Health (R21CA256280).

4.
World J Gastrointest Endosc ; 16(6): 335-342, 2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38946853

ABSTRACT

BACKGROUND: Improved adenoma detection rate (ADR) has been demonstrated with artificial intelligence (AI)-assisted colonoscopy. However, data on the real-world application of AI and its effect on colorectal cancer (CRC) screening outcomes is limited. AIM: To analyze the long-term impact of AI on a diverse at-risk patient population undergoing diagnostic colonoscopy for positive CRC screening tests or symptoms. METHODS: AI software (GI Genius, Medtronic) was implemented into the standard procedure protocol in November 2022. Data was collected on patient demographics, procedure indication, polyp size, location, and pathology. CRC screening outcomes were evaluated before and at different intervals after AI introduction with one year of follow-up. RESULTS: We evaluated 1008 colonoscopies (278 pre-AI, 255 early post-AI, 285 established post-AI, and 190 late post-AI). The ADR was 38.1% pre-AI, 42.0% early post-AI (P = 0.77), 40.0% established post-AI (P = 0.44), and 39.5% late post-AI (P = 0.77). There were no significant differences in polyp detection rate (PDR, baseline 59.7%), advanced ADR (baseline 16.2%), and non-neoplastic PDR (baseline 30.0%) before and after AI introduction. CONCLUSION: In patients with an increased pre-test probability of having an abnormal colonoscopy, the current generation of AI did not yield enhanced CRC screening metrics over high-quality colonoscopy. Although the potential of AI in colonoscopy is undisputed, current AI technology may not universally elevate screening metrics across all situations and patient populations. Future studies that analyze different AI systems across various patient populations are needed to determine the most effective role of AI in optimizing CRC screening in clinical practice.

5.
Curr Med Sci ; 44(3): 554-560, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38842773

ABSTRACT

OBJECTIVE: This study aimed to compare the performance of standard-definition white-light endoscopy (SD-WL), high-definition white-light endoscopy (HD-WL), and high-definition narrow-band imaging (HD-NBI) in detecting colorectal lesions in the Chinese population. METHODS: This was a multicenter, single-blind, randomized, controlled trial with a non-inferiority design. Patients undergoing endoscopy for physical examination, screening, and surveillance were enrolled from July 2017 to December 2020. The primary outcome measure was the adenoma detection rate (ADR), defined as the proportion of patients with at least one adenoma detected. The associated factors for detecting adenomas were assessed using univariate and multivariate logistic regression. RESULTS: Out of 653 eligible patients enrolled, data from 596 patients were analyzed. The ADRs were 34.5% in the SD-WL group, 33.5% in the HD-WL group, and 37.5% in the HD-NBI group (P=0.72). The advanced neoplasm detection rates (ANDRs) in the three arms were 17.1%, 15.5%, and 10.4% (P=0.17). No significant differences were found between the SD group and HD group regarding ADR or ANDR (ADR: 34.5% vs. 35.6%, P=0.79; ANDR: 17.1% vs. 13.0%, P=0.16, respectively). Similar results were observed between the HD-WL group and HD-NBI group (ADR: 33.5% vs. 37.7%, P=0.45; ANDR: 15.5% vs. 10.4%, P=0.18, respectively). In the univariate and multivariate logistic regression analyses, neither HD-WL nor HD-NBI led to a significant difference in overall adenoma detection compared to SD-WL (HD-WL: OR 0.91, P=0.69; HD-NBI: OR 1.15, P=0.80). CONCLUSION: HD-NBI and HD-WL are comparable to SD-WL for overall adenoma detection among Chinese outpatients. It can be concluded that HD-NBI or HD-WL is not superior to SD-WL, but more effective instruction may be needed to guide the selection of different endoscopic methods in the future. Our study's conclusions may aid in the efficient allocation and utilization of limited colonoscopy resources, especially advanced imaging technologies.


Subject(s)
Adenoma , Colonoscopy , Colorectal Neoplasms , Narrow Band Imaging , Humans , Male , Colorectal Neoplasms/diagnostic imaging , Colorectal Neoplasms/diagnosis , Female , Middle Aged , Adenoma/diagnostic imaging , Adenoma/diagnosis , Narrow Band Imaging/methods , Colonoscopy/methods , Aged , Single-Blind Method , Light , Adult
6.
Scand J Gastroenterol ; : 1-8, 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38850200

ABSTRACT

BACKGROUND AND STUDY AIMS: Long-time follow-up of sigmoidoscopy screening trials has shown reduced incidence and mortality of colorectal cancer (CRC), but inadequate bowel cleansing may hamper efficacy. The aim of this study was to assess the impact of bowel cleansing quality in sigmoidoscopy screening. PATIENTS AND METHODS: Individuals 50 to 74 years old who had a screening sigmoidoscopy in a population-based Norwegian, randomized trial between 2012 and 2019, were included in this cross-sectional study. The bowel cleansing quality was categorised as excellent, good, partly poor, or poor. The effect of bowel cleansing quality on adenoma detection rate (ADR) and referral to colonoscopy was evaluated by fitting multivariable logistic regression models. RESULTS: 35,710 individuals were included. The bowel cleansing at sigmoidoscopy was excellent in 20,934 (58.6%) individuals, good in 6580 (18.4%), partly poor in 7097 (19.9%) and poor in 1099 (3.1%). The corresponding ADRs were 17.0%, 16.6%, 14.5%, and 13.0%. Compared to participants with excellent bowel cleansing, those with poor bowel cleansing had an odds ratio for adenoma detection of 0.66 (95% confidence interval 0.55-0.79). We found substantial differences in the assessment of bowel cleansing quality among endoscopists. CONCLUSIONS: Inadequate bowel cleansing reduces the efficacy of sigmoidoscopy screening, by lowering ADR. A validated rating scale and improved bowel preparation are needed to make sigmoidoscopy an appropriate screening method.Trial registration Clinicaltrials.gov (NCT01538550).

7.
Life (Basel) ; 14(6)2024 May 21.
Article in English | MEDLINE | ID: mdl-38929637

ABSTRACT

Adenoma detection rate (ADR) is challenging to measure, given its dependency on pathology reporting. Polyp detection rate (PDR) (percentage of screening colonoscopies detecting a polyp) is a proposed alternative to overcome this issue. Overall PDR from all colonoscopies is a relatively novel concept, with no large-scale studies comparing overall PDR with screening-only PDR. The aim of the study was to compare PDR from screening, surveillance, and diagnostic indications with overall PDR and evaluate any correlation between individual endoscopist PDR by indication to determine if overall PDR can be a valuable surrogate for screening PDR. Our study analyzed a prospectively collected national endoscopy database maintained by the National Institute of Health from 2009 to 2014. Out of 354,505 colonoscopies performed between 2009-2014, 298,920 (n = 110,794 average-risk screening, n = 83,556 average-risk surveillance, n = 104,770 diagnostic) met inclusion criteria. The median screening PDR was 25.45 (IQR 13.15-39.60), comparable with the median overall PDR of 24.01 (IQR 11.46-35.86, p = 0.21). Median surveillance PDR was higher at 33.73 (IQR 16.92-47.01), and median diagnostic PDR was lower at 19.35 (IQR 9.66-29.17), compared with median overall PDR 24.01 (IQR 11.46-35.86; p < 0.01). The overall PDR showed excellent concordance with screening, surveillance, and diagnostic PDR (r > 0.85, p < 0.01, 2-tailed). The overall PDR is a reliable and pragmatic surrogate for screening PDR and can be measured in real time, irrespective of colonoscopy indication.

8.
Brain Behav ; 14(6): e3304, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38760914

ABSTRACT

BACKGROUND: Contrast-enhanced transcranial Doppler (cTCD) study has been established as one of the most common investigations for detecting right-to-left shunt (RLS). Although the conventional Valsalva maneuver (c-VM) has been used to increase the sensitivity of cTCD for RLS, efforts are still needed to improve the detection rate further. We proposed a new provocation method with a syringe-modified Valsalva maneuver (sm-VM) during cTCD and compared the efficacy of this strategy with cTCD measured at resting and with the provocation of c-VM. METHODS: Consecutive patients with suspicion of RLS who underwent cTCD in our institution between September 27, 2021, and April 1, 2022, were included in this study. Examination of cTCD was performed separately at the resting state and provoked with c-VM and sm-VM. The overall proportion of patients with RLS and their distribution with different RLS grades were compared. RESULTS: A total of 389 patients (mean age: 49.37 years, male: 52.2%) were included in this study. The positive rate for RLS was significantly higher for cTCD detected with sm-VM than those detected at resting state and with c-VM (46.8% vs. 21.6% and 34.2%, all p < .05). Besides, cTCD detected with sm-VM was also associated with a higher proportion of patients with grade III RLS than those detected at resting state and with c-VM (11.3% vs. 1.8% and 0%, all p < .05). CONCLUSIONS: Compared to cTCD detected at resting state and with c-VM, cTCD with sm-VM could further increase the positive detection rate of RLS.


Subject(s)
Ultrasonography, Doppler, Transcranial , Valsalva Maneuver , Humans , Male , Ultrasonography, Doppler, Transcranial/methods , Female , Middle Aged , Adult , Contrast Media/administration & dosage , Aged , Syringes , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/physiopathology
9.
J Dig Dis ; 25(3): 191-199, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38697920

ABSTRACT

OBJECTIVE: To compare the detection rate and diagnostic accuracy of cardia polyps using endoscopy with blue laser imaging (BLI) and white-light imaging (WLI). METHODS: Patients were randomly divided into the BLI group and WLI group according to the endoscopic procedures. BLI followed by WLI was conducted in the BLI group, whereas WLI followed by BLI examination was conducted in the WLI group. The number, size, microstructure, and microvascular patterns of cardia polyps detected were recorded. Biopsy of the polyps was then performed. RESULTS: The detection rate of cardia polyps in the BLI group was higher than that in the WLI group (7.87% vs 4.22%, P = 0.018). The rate of overlooked lesions in the BLI group was lower than in the WLI group (0.64% vs 3.38%, P = 0.003). The diagnostic coincidence rate between magnifying BLI and histopathology was 88.16%. The sensitivity, specificity, positive predictive value and negative predictive value for the diagnosis of neoplastic lesions by magnifying endoscopy with BLI were 90.91%, 87.69%, 55.56%, and 98.28%, respectively. The most remarkable patterns for predicting inflammatory polyps were the prolonged and fine network patterns (sensitivity 71.43%, specificity 93.75%). Small round combined with honeycomb patterns were the most common among fundic gland polyps (sensitivity 80.00%, specificity 98.48%). Neoplastic lesions presented as villous or ridge-like combined with core vascular or unclear pattern for both microvascular and microstructure patterns. CONCLUSION: BLI is more effective than WLI in the detection and diagnosis of cardia polyps, and magnifying endoscopy with BLI may help diagnose such lesions.


Subject(s)
Cardia , Feasibility Studies , Stomach Neoplasms , Humans , Female , Male , Middle Aged , Cardia/pathology , Cardia/diagnostic imaging , Adult , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/diagnosis , Stomach Neoplasms/pathology , Aged , Polyps/diagnostic imaging , Polyps/diagnosis , Gastroscopy/methods , Sensitivity and Specificity , Predictive Value of Tests , Lasers
10.
Front Med (Lausanne) ; 11: 1376586, 2024.
Article in English | MEDLINE | ID: mdl-38721355

ABSTRACT

Background and aims: Colonoscopy is an essential cancer screening tool; however, bowel preparation is a multifaceted process that involves several steps. Proper preparation is crucial for a successful colonoscopy in terms of diagnostic accuracy and procedural safety. We evaluated the performance of a smartphone application with bowel preparation instructions on individuals undergoing their first colonoscopy. Methods: In this randomized, prospective, endoscopist-blinded study, participants were scheduled to undergo their first colonoscopy between January 2020 and January 2022. The study protocol was registered at Thai Clinical Trials Registry (TCTR20190928002). They were randomly assigned to the smartphone education application (APP) or the standard education (control) group. The Boston Bowel Preparation Scale (BBPS) score, polyp detection rate (PDR), and adenoma detection rate (ADR) were compared. Factors associated with excellent bowel preparation were also evaluated. Results: In total, 119 patients (APP group, n = 57; control group, n = 62) underwent their first colonoscopy. The mean BBPS score and proportion of excellent bowel preparation (BBPS≥8) were significantly higher in the APP group than in the control group. Smartphone application-guided bowel preparation achieved a higher proportion of adequate and excellent bowel preparation scores, was associated with other quality indicators, and achieved the target ADR, cecal intubation rate, and adequate withdrawal time. Conclusion: This application may be a user-friendly option to improve the first-time colonoscopy experience, resulting in effective screening of colorectal cancer. Clinical trial registration: The study protocol was registered at Thai Clinical Trials Registry (TCTR20190928002).

11.
Scand J Gastroenterol ; : 1-11, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38775234

ABSTRACT

BACKGROUND: Adenoma detection rate (ADR) is higher after a positive fecal immunochemical test (FIT) compared to direct screening colonoscopy. OBJECTIVE: This meta-analysis evaluated how ADR, the rates of advanced adenoma detection (AADR), colorectal cancer detection (CDR), and sessile serrated lesion detection (SSLDR) are affected by different FIT positivity thresholds. METHODS: We searched MEDLINE, EMBASE, CINAHL, and EBM Reviews databases for studies reporting ADR, AADR, CDR, and SSLDR according to different FIT cut-off values in asymptomatic average-risk individuals aged 50-74 years old. Data were stratified according to sex, age, time to colonoscopy, publication year, continent, and FIT kit type. Study quality, heterogeneity, and publication bias were assessed. RESULTS: Overall, 4280 articles were retrieved and fifty-eight studies were included (277,661 FIT-positive colonoscopies; mean cecal intubation 96.3%; mean age 60.8 years; male 52.1%). Mean ADR was 56.1% (95% CI 53.4 - 58.7%), while mean AADR, CDR, and SSLDR were 27.2% (95% CI 24.4 - 30.1%), 5.3% (95% CI 4.7 - 6.0%), and 3.0% (95% CI 1.7 - 4.6%), respectively. For each 20 µg Hb/g increase in FIT cut-off level, ADR increased by 1.54% (95% CI 0.52 - 2.56%, p < 0.01), AADR by 3.90% (95% CI 2.76 - 5.05%, p < 0.01) and CDR by 1.46% (95% CI 0.66 - 2.24%, p < 0.01). Many detection rates were greater amongst males and Europeans. CONCLUSIONS: ADRs in FIT-positive colonoscopies are influenced by the adopted FIT positivity threshold, and identified targets, importantly, proved to be higher than most current societal recommendations.

12.
J Clin Med ; 13(10)2024 May 15.
Article in English | MEDLINE | ID: mdl-38792451

ABSTRACT

Background: Chronic constipation, a prevalent gastrointestinal complaint, exhibits rising incidence and diverse clinical implications, especially among the aging population. This study aims to assess colonoscopy performance in chronic constipation across age groups, comprehensively evaluating diagnostic yield and comparing results with average-risk controls. Methods: A retrospective analysis was conducted on 50,578 colonoscopy procedures performed over 12 years, including 5478 constipated patients. An average-risk control group (n = 4100) was included. Data extracted from electronic medical records covered demographics, operational aspects, and colonoscopy findings. The primary outcome measures included the diagnosis rate of colorectal cancer (CRC), polyp detection rate (PDR), and inflammatory bowel disease (IBD) diagnoses in constipated patients versus controls, with age-based and multivariate analyses. Results: Constipated patients exhibiting lower rates of adequate bowel preparation (92.7% vs. 85.3%; p < 0.001) and a lower cecal intubation rate. No significant variances between CRC and PDR were observed between constipated and controls, except for a potential of a slightly elevated CRC risk in constipated patients older than 80 (2.50% vs. 0% in controls; p = 0.07). Multivariate analysis demonstrated, across all age groups, that constipation did not confer an increased risk for CRC or polyp detection. Younger constipated patients exhibited a higher rate of IBD diagnoses (1.7% vs. 0.1% in controls; p < 0.001). Conclusions: Constipation did not confer an increased risk for CRC or polyps, among any age groups, except for a potential signal of elevated CRC risk in patients older than 80; additionally, it was associated with higher rates of IBD in younger patients.

14.
Article in English | MEDLINE | ID: mdl-38602345

ABSTRACT

BACKGROUND AND AIM: Linked color imaging (LCI) is an image-enhanced endoscopy technique that accentuates the color difference between red and white, potentially improving the adenoma detection rate (ADR). However, it remains unclear whether LCI performance in detecting colorectal lesions differs based on endoscopists' experience levels. We aimed to evaluate the differences in LCI efficacy based on the experience levels of endoscopists by conducting an exploratory analysis. METHODS: In this post hoc analysis of an international randomized controlled trial comparing the detection of adenoma and other lesions using colonoscopy with LCI and high-definition white light imaging (WLI), we included patients from 11 institutions across four countries/regions: Japan, Thailand, Taiwan, and Singapore. We retrospectively reviewed differences in the lesion detection of LCI according to endoscopists' colonoscopy history or ADR. RESULTS: We included 1692 and 1138 patients who underwent colonoscopies performed by 54 experts (experience of ≥ 5000 colonoscopies) and by 43 non-experts (experience of < 5000 colonoscopies), respectively. Both expert and non-expert groups showed a significant improvement in ADR with LCI compared to WLI (expert, 61.7% vs 46.4%; P < 0.001; non-expert, 56.6% vs 46.4%; P < 0.001). LCI had no effect on sessile serrated lesion detection rate in non-experts (3.1% vs 2.5%; P = 0.518). LCI significantly improved detection rates in endoscopists with relatively low detection performance, defined as an ADR < 50%. CONCLUSIONS: This exploratory study analyzed data from a previous trial and revealed that LCI is useful for both experts and non-experts and is even more beneficial for endoscopists with relatively low detection performance using WLI.

15.
Expert Rev Med Devices ; 21(5): 359-372, 2024 May.
Article in English | MEDLINE | ID: mdl-38618982

ABSTRACT

INTRODUCTION: The identification of early-stage colorectal cancers (CRC) and the resection of pre-cancerous neoplastic lesions through colonoscopy allows to decrease both CRC incidence and mortality. However, colonoscopy miss rates up to 26% for adenomas and 9% for advanced adenomas have been reported. In recent years, artificial intelligence (AI) systems have been emerging as easy-to-use tools, potentially lowering the risk of missing lesions. AREAS COVERED: This review paper focuses on GI Genius device (Medtronic Co. Minneapolis, MN, U.S.A.) a computer-assisted tool designed to assist endoscopists during standard white-light colonoscopies in detecting mucosal lesions. EXPERT OPINION: Randomized controlled trials (RCTs) suggest that GI Genius is a safe and effective tool for improving adenoma detection, especially in CRC screening and surveillance colonoscopies. However, its impact seems to be less significant among experienced endoscopists and in real-world clinical scenarios compared to the controlled conditions of RCTs. Furthermore, it appears that GI Genius mainly enhances the detection of non-advanced, small polyps, but does not significantly impact the identification of advanced and difficult-to-detect adenoma. When using GI Genius, no complications were documented. Only a small number of studies reported an increased in withdrawal time or the removal of non-neoplastic lesions.


Subject(s)
Colorectal Neoplasms , Humans , Colorectal Neoplasms/diagnosis , Colonoscopy/methods , Adenoma/diagnosis , Adenoma/diagnostic imaging , Artificial Intelligence
16.
World J Gastrointest Endosc ; 16(3): 126-135, 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38577646

ABSTRACT

The number and variety of applications of artificial intelligence (AI) in gastrointestinal (GI) endoscopy is growing rapidly. New technologies based on machine learning (ML) and convolutional neural networks (CNNs) are at various stages of development and deployment to assist patients and endoscopists in preparing for endoscopic procedures, in detection, diagnosis and classification of pathology during endoscopy and in confirmation of key performance indicators. Platforms based on ML and CNNs require regulatory approval as medical devices. Interactions between humans and the technologies we use are complex and are influenced by design, behavioural and psychological elements. Due to the substantial differences between AI and prior technologies, important differences may be expected in how we interact with advice from AI technologies. Human-AI interaction (HAII) may be optimised by developing AI algorithms to minimise false positives and designing platform interfaces to maximise usability. Human factors influencing HAII may include automation bias, alarm fatigue, algorithm aversion, learning effect and deskilling. Each of these areas merits further study in the specific setting of AI applications in GI endoscopy and professional societies should engage to ensure that sufficient emphasis is placed on human-centred design in development of new AI technologies.

17.
Gastrointest Endosc ; 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38580134

ABSTRACT

BACKGROUND AND AIMS: Endoscopists' competence can vary widely, as shown in the variation in adenoma detection rate (ADR). Computer-aided quality assessment (CAQ) can automatically assess performance during individual procedures. This review aims to identify and describe different CAQ systems for colonoscopy. METHODS: A systematic review of the literature was done using MEDLINE, EMBASE, and SCOPUS based on three blocks of terms according to the inclusion criteria: Colonoscopy, Competence assessment, and Automatic evaluation. Articles were systematically reviewed by two reviewers, first by abstract and then in full text. The methodological quality was assessed using the Medical Education Research Study Quality Instrument (MERSQI). RESULTS: 12,575 studies were identified, 6,831 remained after removal of duplicates, and 6,806 did not pass the eligibility criteria and were excluded, leaving thirteen studies for final analysis. Five categories of CAQ systems were identified: Withdrawal speedometer (seven studies), Scope movement analysis (three studies), Effective withdrawal time (one study), Fold examination quality (one study), and Visual gaze pattern (one study). The withdrawal speedometer was the only CAQ system that tested its feedback by examining changes in ADR. Three studies observed an improvement in ADR, and two studies did not. The methodological quality of the studies was high (mean MERSQI 15.2 points, maximum 18 points). CONCLUSIONS: Thirteen studies developed or tested CAQ systems, most frequently by correlating it to ADR. Only five studies tested feedback by implementing the CAQ system. A meta-analysis was impossible due to the heterogeneous study designs, and more studies are warranted.

18.
Article in Chinese | MEDLINE | ID: mdl-38563166

ABSTRACT

Objective:To analyze the mutation spectrum of 23-site chip newborn deafness genetic screening in Beijing, and to provide basis for genetic counseling and clinical diagnosis and treatment. Methods:The study included 21 006 babies born in Beijing from December 2022 to June 2023. All subjects underwent newborn deafness genetic screening in Beijing Tongren Hospital, covering 23 variants in 4 genes, the GJB2 gene(c.35delG, c.176_191del16, c.235delC, c.299_300delAT, c.109G>A, c.257C>G, c.512insAACG, c.427C>T, c.35insG), SLC26A4 gene(c.919-2A>G, c.2168A>G, c.1174A>T, c.1226G>A, c.1229C>T, c.1975G>C, c.2027T>A, c.589G>A, c.1707+5G>A, c.917insG, c.281C>T), Mt12SrRNA(m.1555A>G, m.1494C>T) and GJB3 gene(c.538C>T). The mutation detection rate and allele frequency were analyzed. Results:The overall mutation detection rate was 11.516%(2 419/21 006), with the GJB2 gene being the most frequently involved at 9.097%(1 911/21 006), followed by the SLC26A4 gene at 2.123%(446/21 006), the GJB3 gene at 0.362%(76/21 006) and Mt12SrRNA at 0.176%(37/21 006). Among the GJB2 genes, c.109G>A and c.235delC mutation detection rates were the highest, with 6.579%(1 382/21 006) and 1.795%(377/21 006), respectively. Of the SLC26A4 genes, c.919-2A>G and c.2168A>G had the highest mutation rates of 1.423%(299/21 006) and 0.233%(49/21 106), respectively. Regarding the allele frequency, GJB2 c.109G>A was the most common variant with an allele frequency of 3.359%(1 411/42 012), followed by the GJB2 c.235delC at 0.897%(377/42 012) and the SLC26A4 c.919-2A>G at 0.719%(302/42 012). Conclusion:23-site chip newborn deafness genetic screening in Beijing showed that GJB2 c.109G>A mutation detection rate and allele frequency were the highest. This study has enriched the epidemiological data of 23-site chip genetic screening mutation profiles for neonatal deafness, which can provide evidence for clinical practice.


Subject(s)
Deafness , Hearing Loss , Infant , Infant, Newborn , Humans , Connexins/genetics , Connexin 26/genetics , Deafness/genetics , Deafness/diagnosis , DNA Mutational Analysis , Sulfate Transporters/genetics , Genetic Testing , Mutation , Hearing Loss/genetics , Neonatal Screening , China
19.
Cancer Med ; 13(8): e7133, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38634216

ABSTRACT

BACKGROUND: Compliance with colonoscopy among elderly individuals participating in colorectal cancer (CRC) screening programs is unsatisfactory, despite a high detection rate of bowel-related diseases. In this study, our aim was to analyze the impact of risk factors on the trends of compliance and detection rates in colonoscopy among high-risk individuals aged 60-74. METHODS: A retrospective study was conducted on the high-risk individuals aged 60-74 participating in the 2021 CRC screening program in Tianjin, China. Logistic regression analyses, including both univariate and multivariate analyses, were performed to explore the impact of different risk factors on colonoscopy compliance among the high-risk individuals. Besides, the study investigated the influence of various risk factors on the detection rates of bowel-related diseases among the high-risk individuals who underwent colonoscopy. RESULTS: A total of 24,064 high-risk individuals were included, and 5478 individuals received a free colonoscopy, with an overall compliance of 22.76%. Among them, the adenoma detection rate was 55.46%. Males and individuals with a positive FIT had high compliance and detection rates for CRC, advanced adenomas (AA), advanced colorectal neoplasia (ACN), and colorectal neoplasm (CN). Individuals aged 70-74 were associated with low compliance but high CRC, ACN, and CN detection rates. Individuals who reported a history of chronic constipation, bloody mucous, and CRC in first-degree relative showed high compliance but no significantwere associated with the detection rates of CRC, AA, and CN. CONCLUSION: This study reported several risk factors associated with the screening behaviors for CRC. Patterns and trends in CRC, AA, ACN, and CN compliance and detection rates correlate with risk factors.


Subject(s)
Colorectal Neoplasms , Early Detection of Cancer , Male , Aged , Humans , Incidence , Retrospective Studies , Colorectal Neoplasms/diagnosis , Colonoscopy , Risk Factors , Mass Screening
20.
BMC Gastroenterol ; 24(1): 132, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38609900

ABSTRACT

BACKGROUND: Different split regimens of polyethylene glycol are routinely used and no guidelines are available to select an optimal protocol of ingestion. This study aims to compare the efficacy and side effect profile of two different regimens of polyethylene glycol bowel preparation solution: PEG (3 + 1) vs. PEG (2 + 2). METHODS: 240 patients above the age of 18 years were included in the study between June 1st and November 31st, 2023. Patients were randomly assigned either to Group A, consisting of 115 patients receiving a 3 L of PEG the night before the colonoscopy, and 1 L the same morning of the procedure. Or to group B, where 125 patients ingested 2 L the night before the procedure, and the remaining 2 L the same morning. The cleansing efficacy was evaluated by the attending endoscopist using the Boston Bowel Preparation Scale, through a score assigned for each segment of the colon (0-3). Side effects, tolerability, and willingness to retake the same preparation were listed by an independent investigator using a questionnaire administered before the procedure. RESULTS: A higher percentage of patients had gastric fullness with the 3 + 1 vs. 2 + 2 preparation (58.3% vs. 31.2%; p <.001). A higher Boston bowel preparation score was seen in patients who took the 2 + 2 vs. 3 + 1 preparation (7.87 vs. 7.23). Using the 2 + 2 preparation was significantly associated with higher Boston bowel preparation scores vs. the 3 + 1 preparation (OR = 1.37, p =.001, 95% CI 1.14, 1.64). After adjustment over other variables (age, gender, comorbidities, previous abdominal surgeries, presence of adenoma, and time between last dose and colonoscopy), results remained the same (aOR = 1.34, p =.003, 95% CI 1.10, 1.62). CONCLUSION: While both (2 + 2) and (3 + 1) regimens of polyethylene glycol are a good choice for a successful colonoscopy, we recommend the use of (2 + 2) regimen for its superior efficacy in bowel cleansing.


Subject(s)
Colonoscopy , Polyethylene Glycols , Humans , Adolescent , Prospective Studies , Clinical Protocols , Polyethylene Glycols/adverse effects , Stomach
SELECTION OF CITATIONS
SEARCH DETAIL
...