Sensors (Basel) ; 22(7)2022 Mar 31.
Article in English | MEDLINE | ID: mdl-35408305

ABSTRACT

We present a preliminary study of microwave head imaging using a three-dimensional (3-D) implementation of the distorted Born iterative method (DBIM). Our aim is to examine the benefits of using the more computationally intensive 3-D implementation in scenarios where limited prior information is available, or when the target occupies an area that is not covered by the imaging array's transverse planes. We show that, in some cases, the 3-D implementation outperforms its two-dimensional (2-D) counterpart despite the increased number of unknowns for the linear problem at each DBIM iteration. We also discuss how the 3-D algorithm can be implemented efficiently using graphic processing units (GPUs) and validate this implementation with experimental data from a simplified brain phantom. In this work, we have implemented a non-linear microwave imaging approach using DBIM with GPU-accelerated FDTD. Moreover, the paper offers a direct comparison of 2-D and 3-D microwave tomography implementations for head imaging and stroke detection in inhomogenous anatomically complex numerical head phantoms.


Subject(s)
Microwave Imaging , Microwaves , Algorithms , Diagnostic Imaging , Imaging, Three-Dimensional/methods , Phantoms, Imaging
2.
Biomed Eng Lett ; 9(4): 449-465, 2019 Nov.
Article in English | MEDLINE | ID: mdl-31799014

ABSTRACT

Ultrasonic computed tomography based on back scattering theory is the most powerful and accurate tool in ultrasound based imaging approaches because it is capable of providing quantitative information about the imaged target and detects very small targets. The duple-frequency distorted Born iterative method (DF-DBIM), which uses density information along with sound contrast for imaging, is a promising approach for imaging targets at the level of biological tissues. With two frequencies f1 (low) and f2 (high) through N f 1 and N f 2 iterations respectively, this method is used to estimate target density along with sound contrast. The implications of duple-frequency fusion for the image reconstruction quality of density information along with sound contrast based ultrasound tomography have been analyzed in this paper. In this paper, we concentrate on the selection of parameters that is supposed to be the best to improve the reconstruction quality of ultrasound tomography. When there are restraints imposed on simulated scenarios to have control of the computational cost, the iteration number N f 1 is determined resulting in giving the best performance. The DF-DBIM is only effective if there are a moderate number of iterations, transmitters and receivers. In case that the number of transducers is either too large or too small, a result of reconstruction which is better than that of the single frequency approach is not produced by the implementation of DF-DBIM. A fixed sum N iter of N f 1 and N f 2 was given, the investigation of simulation results shows that the best value of N f 1 is N iter 2 - 1 . The error, when applying this way of choosing the parameters, will be normalized with the reduction of 56.11%, compared to use single frequency as used in the conventional DBIM method. The target density along with sound contrast is used to image targets in this paper. It is a fact that low-frequency offers fine convergence, and high-frequency offers fine spatial resolution. Wherefore, this technique can effectively expand DBIM's applicability to the problem of biological tissue reconstruction. Thanks to the usage of empirical data, this work will be further developed prior to its application in reality.

3.
Biomedical Engineering Letters ; (4): 449-465, 2019.
Article in English | WPRIM (Western Pacific) | ID: wpr-785529

ABSTRACT

Ultrasonic computed tomography based on back scattering theory is the most powerful and accurate tool in ultrasound based imaging approaches because it is capable of providing quantitative information about the imaged target and detects very small targets. The duple-frequency distorted Born iterative method (DF–DBIM), which uses density information along with sound contrast for imaging, is a promising approach for imaging targets at the level of biological tissues. With two frequencies f₁ (low) and f₂ (high) through Nf₁ and Nf₂ iterations respectively, this method is used to estimate target density along with sound contrast. The implications of duple-frequency fusion for the image reconstruction quality of density information along with sound contrast based ultrasound tomography have been analyzed in this paper. In this paper, we concentrate on the selection of parameters that is supposed to be the best to improve the reconstruction quality of ultrasound tomography. When there are restraints imposed on simulated scenarios to have control of the computational cost, the iteration number Nf₁ is determined resulting in giving the best performance. The DF–DBIM is only effective if there are a moderate number of iterations, transmitters and receivers. In case that the number of transducers is either too large or too small, a result of reconstruction which is better than that of the single frequency approach is not produced by the implementation of DF–DBIM. A fixed sum N(iter) of Nf₁ and Nf₂ was given, the investigation of simulation results shows that the best value of Nf₁ is [N(iter)/2 − 1]. The error, when applying this way of choosing the parameters, will be normalized with the reduction of 56.11%, compared to use single frequency as used in the conventional DBIM method. The target density along with sound contrast is used to image targets in this paper. It is a fact that low-frequency offers fine convergence, and high-frequency offers fine spatial resolution. Wherefore, this technique can effectively expand DBIM's applicability to the problem of biological tissue reconstruction. Thanks to the usage of empirical data, this work will be further developed prior to its application in reality.


Subject(s)
Image Processing, Computer-Assisted , Methods , Transducers , Ultrasonics , Ultrasonography
4.
BMC Med Imaging ; 17(1): 34, 2017 05 25.
Article in English | MEDLINE | ID: mdl-28545406

ABSTRACT

BACKGROUND: A well-known diagnostic imaging modality, termed ultrasound tomography, was quickly developed for the detection of very small tumors whose sizes are smaller than the wavelength of the incident pressure wave without ionizing radiation, compared to the current gold-standard X-ray mammography. Based on inverse scattering technique, ultrasound tomography uses some material properties such as sound contrast or attenuation to detect small targets. The Distorted Born Iterative Method (DBIM) based on first-order Born approximation is an efficient diffraction tomography approach. One of the challenges for a high quality reconstruction is to obtain many measurements from the number of transmitters and receivers. Given the fact that biomedical images are often sparse, the compressed sensing (CS) technique could be therefore effectively applied to ultrasound tomography by reducing the number of transmitters and receivers, while maintaining a high quality of image reconstruction. METHODS: There are currently several work on CS that dispose randomly distributed locations for the measurement system. However, this random configuration is relatively difficult to implement in practice. Instead of it, we should adopt a methodology that helps determine the locations of measurement devices in a deterministic way. For this, we develop the novel DCS-DBIM algorithm that is highly applicable in practice. Inspired of the exploitation of the deterministic compressed sensing technique (DCS) introduced by the authors few years ago with the image reconstruction process implemented using l 1 regularization. RESULTS: Simulation results of the proposed approach have demonstrated its high performance, with the normalized error approximately 90% reduced, compared to the conventional approach, this new approach can save half of number of measurements and only uses two iterations. Universal image quality index is also evaluated in order to prove the efficiency of the proposed approach. CONCLUSIONS: Numerical simulation results indicate that CS and DCS techniques offer equivalent image reconstruction quality with simpler practical implementation. It would be a very promising approach in practical applications of modern biomedical imaging technology.


Subject(s)
Breast/diagnostic imaging , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Algorithms , Data Compression/methods , Female , Humans , Random Allocation , Ultrasonography, Mammary