Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Publication year range
1.
Am J Sports Med ; 52(7): 1676-1684, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38767156

ABSTRACT

BACKGROUND: Improper sequencing order of maximal joint and segment velocities has been identified as an important predictor for both throwing arm kinetics and ball velocity. PURPOSE: To investigate the intrapitcher variation of maximal segment velocities and the relationship to throwing arm kinetics and ball velocity in high school (HS) and professional (PRO) pitchers. STUDY DESIGN: Descriptive laboratory study. METHODS: HS (n = 59) and PRO (n = 338) pitchers, instructed to throw 8 to 12 fastball pitches, were evaluated with 3-dimensional motion capture (480 Hz). Maximal joint and segment velocities were calculated for each pitch, and the standard deviation of the maxima was calculated per pitcher. These standard deviations were used to classify pitchers as "low variance" or "high variance" for each segmental velocity subgroup, "overall low variance" or "overall high variance" based on cumulative segment velocity variation, or "population," with any pitcher eligible to be included in multiple subcategories. Maximal velocities and throwing arm kinetics were compared among the various subgroups. RESULTS: The HS low-variance shoulder internal rotation velocity subgroup (4949 ± 642 deg/s) had significantly lower maximal shoulder internal rotation velocity compared with HS population (5774 ± 1057 deg/s) (P < .001); similar findings were observed for PROs (5269 ± 835 vs 5824 ± 1076 deg/s; P < .001), as well as lower shoulder superior force compared with the PRO population (14.8% ± 8.8% vs 17.8% ± 8.8% body weight; P = .001). The PRO low-variance lead knee extension velocity subgroup had significantly lower maximal lead knee extension velocity (216 ± 135 vs 258 ± 125 deg/s; P = .001) and shoulder distractive force (111.5% ± 14.4% vs 115.6% ± 15.9% body weight; P = .003) compared with the PRO population. The PRO overall low-variance subgroup had significantly lower shoulder distractive force (111.8% ± 14.1% vs 119.6% ± 15.5% body weight; P = .008) and elbow anterior force (40.6% ± 5.0% vs 43.6% ± 6.2% body weight; P = .008) compared with the PRO overall high-variance subgroup. CONCLUSION: HS and PRO pitchers with low variance for joint and segment velocities achieved significantly lower maximal velocities in the subgroup of interest, while preserving ball velocity. PRO pitchers with overall low variance among multiple maximal joint and segment velocities demonstrated decreased shoulder distractive and elbow anterior force. CLINICAL RELEVANCE: PRO pitchers with low intrapitch variation in maximal joint and segment velocities may be viewed as kinetically conservative throwers. These pitchers with similarly maintained mechanics between pitches may have an increasingly regimented form that preserves kinetic forces about the throwing arm. The opposite may be true for PRO pitchers with increased variability in segmental velocities during their pitching motion, as they showed increased throwing arm kinetics including shoulder distractive and elbow anterior force compared with the overall low-variance group, theoretically increasing their risk of injury.


Subject(s)
Baseball , Shoulder Joint , Humans , Baseball/physiology , Biomechanical Phenomena , Adolescent , Male , Shoulder Joint/physiology , Arm/physiology , Rotation , Young Adult , Athletic Performance/physiology , Range of Motion, Articular/physiology
2.
Am J Sports Med ; 50(9): 2462-2468, 2022 07.
Article in English | MEDLINE | ID: mdl-35722810

ABSTRACT

BACKGROUND: Questions remain about whether circumferential labral reconstruction (CLR) using an iliotibial band (ITB) allograft can effectively restore the labral suction seal of the hip. HYPOTHESES: (1) CLR with an ITB allograft >6.5 mm would restore distractive stability force to that of the intact labrum. (2) CLR with an ITB allograft >6.5 mm would achieve significantly superior distractive stability force compared with CLR with an ITB allograft <6.5 mm. STUDY DESIGN: Controlled laboratory study. METHODS: A total of 6 fresh-frozen pelves with attached femurs (n = 12 matched hemipelves) from male donors were procured and dissected free of all soft tissue, including the hip capsule but preserving the native labrum, transverse acetabular ligament, and ligamentum teres. Potted hemipelves were placed in a saline bath and securely fixed to the frame of a hydraulic testing system. A 500-N compressive load was applied, followed by femoral distraction at a rate of 5.0 mm/s until the suction seal ruptured. Force and femoral displacement were continually recorded. Force versus displacement curves were plotted, the maximum force was recorded, and the amount of femoral distraction to rupture the suction seal was determined. After intact testing, the labrum was excised, and specimens were retested using the same protocol. CLR was subsequently performed twice in a randomized fashion using (1) an ITB allograft with a width >6.5 mm (7.5-9.0 mm) and (2) an ITB allograft with a width <6.5 mm (4.5-6.0 mm). Specimens were retested after each CLR procedure. Force (in Newtons) and femoral distraction (in millimeters) required to rupture the suction seal were measured and compared between the 4 testing states (intact, deficient, CLR <6.5 mm, and CLR >6.5 mm) using repeated-measures analysis of variance. RESULTS: On average, intact specimens required 148.4 ± 33.1 N of force to rupture the hip suction seal, which significantly decreased to 44.3 N in the deficient state (P < .001). CLR with ITB allografts <6.5 mm did not improve the maximum force (63 ± 62 N) from the deficient state (P = .42) and remained significantly lower than the intact state (P < .01). CLR with ITB allografts >6.5 mm recorded significantly greater force to rupture the suction seal (135.8 ± 44.6 N) compared with both the deficient and CLR <6.5 mm states (P < .01), with a mean force comparable with the intact labrum (P = .59). The amount of femoral distraction to rupture the suction seal demonstrated similar findings. CONCLUSION: In a cadaveric model, CLR using ITB allografts >6.5 mm restored the distractive force and distance to the suction seal rupture to values comparable with hips with an intact labrum. CLR using ITB allografts >6.5 mm outperformed CLR with ITB allografts <6.5 mm, demonstrated by a significantly higher force to rupture the suction seal and increased distraction before the rupture. CLINICAL RELEVANCE: The results of this cadaveric investigation suggest that using wider labral allografts during CLR will provide the distractive force required to rupture the suction seal and immediate postoperative stability of the hip, although further studies are required to determine if these results translate to improved clinical outcomes.


Subject(s)
Acetabulum , Hip Joint , Acetabulum/surgery , Allografts , Cadaver , Fascia Lata/transplantation , Hip Joint/surgery , Humans , Male
3.
J Radiol Case Rep ; 11(2): 23-27, 2017 Feb.
Article in English | MEDLINE | ID: mdl-28580070

ABSTRACT

The classic presentation of penile fracture is a cracking or snap sound, with sharp pain, immediate detumescence, swelling, deformation and ecchymosis. A penile fracture involves rupture of the tunica albuginea of one or both corpora cavernosa. Concomitant urethral rupture is reported to occur in 10% to 20% of penile fracture cases. Isolated urethral injury without penile fracture is extremely rare. We report the first case of isolated pendulous urethral rupture from an abrupt coital distractive force. We include a literature review and discussion of isolated urethral trauma secondary to sexual intercourse. Retrograde urethrography rendered a stunning clinical image which was integral to the diagnosis and management of this patient's injury.


Subject(s)
Urethra/diagnostic imaging , Urethra/injuries , Adult , Coitus , Diagnosis, Differential , Humans , Male , Rupture , Urethra/surgery , Urologic Surgical Procedures, Male
4.
Journal of Medical Biomechanics ; (6): E443-E448, 2016.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-804055

ABSTRACT

Objective Aiming at reducing the restrictions on lower limbs imposed by traditional knee brace, a design scheme for knee brace complying with internal-external rotation is proposed. Methods By adding the internal-external hinge, the knee brace could help to release the degree of freedom (DOM) of internal-external rotation of the knee. In the experimental group, the subject was required to wear the bilateral unloading knee brace with or without internal-external hinges, respectively, while in the control group, the subject did not wear the knee brace. Then gait experiment and mechanical testing were conducted. Results In gait experiment, the bilateral unloading knee brace with internal-external hinges imposed less restriction on the knee than that from the knee brace without internal-external hinges, and it could also provide some distractive force for the knee joint. Conclusions The internal-external hinge design can help to reduce restrictions on the knee imposed from bilateral unloading knee brace.

SELECTION OF CITATIONS
SEARCH DETAIL
...