Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.079
Filter
1.
J Ultrasound Med ; 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38837497

ABSTRACT

OBJECTIVE: This study aimed to validate the efficiency of Doppler ultrasonography for predicting the innominate, subclavian, and common carotid artery stenosis. METHODS: This retrospective multicenter study between 2013 and 2022 enrolled 636 patients who underwent carotid Doppler ultrasonography and subsequent digital subtraction angiography. And 58 innominate artery stenosis, 147 common carotid artery stenosis, and 154 subclavian artery stenosis were included. The peak systolic velocity at innominate, subclavian, and common carotid artery, and velocity ratios of innominate artery to common carotid artery, innominate artery to subclavian artery, and common carotid artery to internal carotid artery were measured or calculated. The threshold values were determined using receiver operating characteristic analysis. RESULTS: The threshold values of innominate artery stenosis were peak systolic velocity >206 cm/s (sensitivity: 82.8%; specificity: 91.4%) to predict ≥50% stenosis and >285 cm/s (sensitivity: 89.2%; specificity: 94.9%) to predict ≥70% stenosis. The threshold values of common carotid artery stenosis were peak systolic velocity >175 cm/s (sensitivity: 78.2%; specificity: 91.9%) to predict ≥50% stenosis and >255 cm/s (sensitivity: 87.1%; specificity: 87.2%) to predict ≥70% stenosis. The threshold values of subclavian artery stenosis were peak systolic velocity >200 cm/s (sensitivity: 68.2%; specificity: 84.4%) to predict ≥50% stenosis and >305 cm/s (sensitivity: 57.9%; specificity: 91.4%) to predict ≥70% stenosis. CONCLUSIONS: Symptomatic patients with ultrasonic parameters of velocity at innominate artery ≥206 cm/s, velocity at common carotid artery ≥175 cm/s, or velocity at subclavian artery ≥200 cm/s need to be considered for further verification and whether revascularization is necessary.

2.
Cureus ; 16(5): e60706, 2024 May.
Article in English | MEDLINE | ID: mdl-38899251

ABSTRACT

Innovative applications of clinical ocular diagnostic tools are emerging to help identify systemic disorders that extend beyond ocular diseases. Ophthalmodynamometry (ODM) is a screening tool that non-invasively determines mean central retinal artery pressure (MCRAP) and ocular perfusion pressure (OPP). Decreased OPP and MCRAP on Falck Medical Multifunctional Device (FMD, Falck Medical, Inc., Mystic, CT), along with reverse ophthalmic artery flow (ROAF) on transcranial Doppler ultrasonography (TCD), indicate increased collateral brain perfusion and possible stenosis of the ophthalmic artery or internal carotid artery (ICA). In this case report, we describe the case of a 78-year-old female with ROAF, reduced MCRAP, and OPP in the right eye, confirmed by carotid duplex of 50-79% right ICA stenosis. Early application of ODM and TCD allowed for prompt diagnosis and management with a vascular specialist.

3.
J Ren Care ; 2024 Jun 08.
Article in English | MEDLINE | ID: mdl-38850083

ABSTRACT

BACKGROUND: The success of haemodialysis (HD) critically depends on the effective use of arteriovenous fistulas (AVFs). The precise needling technique is vital to minimise complications and ensure functional vascular access. OBJECTIVE: This study assesses the effectiveness of a nursing consultation protocol, which integrates physical examination (PE) with Doppler Ultrasound (DUS), in preparing patients for the first AVF needling. DESIGN/PARTICIPANTS: A cross-sectional analysis at a Portuguese National Health Service Hospital engaged thirty new HD patients, four HD needling experienced nurses and one HD vascular access nurse. This study examines the accuracy of PE in assessing the matured AVF by the four nurses compared to a trained vascular access nurse encompassing systematic PE and DUS. MEASUREMENTS: The primary data incorporated AVF characteristics derived from PE (inspection, palpation, and auscultation) and DUS findings (vein depth, diameter, and blood flow). A secondary focus was evaluating the change in nurses' perceived needling complexity following the nursing consultation. RESULTS: The nursing consultation significantly enhanced the identification of crucial AVF features, such as accessory veins (p = 0.002), and improved the accuracy of AVF morphology assessments. This led to identifying longer needling tracks (p = 0.031) and a higher number of safe needling points (p = 0.016). Nurses reported a notable reduction in perceived complexity and potential adverse events following this method (p = 0.027). CONCLUSIONS: Integrating structured PE with DUS in a nursing consultation framework significantly improves the preparation for AVF needling. This approach enhances the efficiency and safety of AVF needling and boosts nurse confidence and patient care in HD settings.

4.
Childs Nerv Syst ; 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38907117

ABSTRACT

PURPOSE: Transcranial doppler based diagnostic criteria for cerebral vasospasm are not well established in the pediatric population because there is no published normative data to support the diagnosis. Studies have relied on expert consensus, but the definitions have not been validated in children diagnosed with angiographic evidence of vasospasm. Obtaining normative data is a prerequisite to defining pediatric cerebral vasospasm and the Lindegaard Ratio (LR). In this study, we obtained normative data and calculation of the normal LR from healthy children aged 10-16 years. METHODS: TCD and carotid ultrasonography was used to measure steady state velocities of both the middle cerebral artery (VMCA) and the extracranial internal cerebral artery (VEICA) in healthy children aged 10-16 years. Demographic information, hemodynamic characteristics and the calculated LR (VMCA/VEICA) was determined for each subject using descriptive statistics. RESULTS: Of the 26 healthy children, 13 were male and 13 were female. VMCA ranged between 53 and 93 cm/sec. LR ranged between 1 and 2.2 for the cohort. VMCA for both males and females were within 2 standard deviations (SD) of the normal mean flow velocity. As the VMCA velocities approached 2 SD above the mean, LR did not exceed 2.2. CONCLUSION: Our results help define a threshold for LR which can be used to establish radiographic criteria for cerebral vasospasm in children. Our data suggests that using VMCA criteria alone would overestimate cerebral vasospasm and raises question of whether an LR threshold other than 3 is more appropriate for the cut off between hyperemia versus vasospasm in children.

5.
Fetal Diagn Ther ; : 1-10, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38815567

ABSTRACT

INTRODUCTION: This study evaluated fetal pancreas size and echogenicity, and splenic artery (SA) waveforms in pregnant women with gestational diabetes mellitus (GDM). METHODS: This prospective case-control study was performed from October 2022 to November 2023 and included 124 pregnant women (62 with GDM and 62 controls). Pancreatic circumference, pancreatic echogenicity, umbilical artery Doppler measurements (systolic/diastolic ratio [S/D] and pulsatility index [PI]), SA Doppler measurements (S/D, PI, peak systolic velocity [PSV], time-averaged maximum velocity, and pressure gradient [PG] mean and maximum) values were compared between the GDM and control groups. RESULTS: The mean pancreatic circumference was higher and grade 2/3 echogenicity was more common in the GDM group, while grade 1 echogenicity was more common in the control group (p < 0.001 and p < 0.001, respectively). SA S/D and PI measurements were significantly higher in the GDM group than in the control group (p < 0.001 and p = 0.001, respectively). Moreover, PGmax was significantly higher in the GDM group than in the control group (p = 0.038). Pancreatic circumference was positively correlated with SA PSV (p = 0.004). Additionally, pancreatic circumference was positively correlated with PGmean and PGmax (p = 0.010 and p = 0.016, respectively). The increase in pancreas echogenicity was positively correlated with SA S/D and PI measurements (p = 0.007 and p = 0.002, respectively). PGmax was also positively correlated with increased pancreas echogenicity (p = 0.023). CONCLUSION: This study showed that fetal pancreas size and echogenicity were significantly higher in pregnant women with GDM than in controls. SA Doppler waveforms were consistent with an increase in vascular resistance associated with elevations of both S/D and PI in the GDM group.

6.
Res Pract Thromb Haemost ; 8(3): 102396, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38694839

ABSTRACT

Background: Plantar vein thrombosis (PVT) is a rare condition. Less than 50 cases have been described in the literature. Evidence from interventional and observational studies is sparse or lacking. Objectives: To describe a consecutive cohort of patients diagnosed with PVT at a single academic institution over the past 17 years. Methods: We searched medical charts from patients managed at the University Hospital Zurich between 2005 and 2022. PVT was detected through sonography (eg, in the presence of a noncompressible deep vein) and/or magnetic resonance (eg, a vein with a filling defect on non-contrast-enhanced or contrast-enhanced imaging). The study was approved by the local ethics commission. Results: We identified 45 patients who had been assessed for PVT. After manual check of these cases, we selected 16 patients with a confirmed, objective diagnosis. Median age was 62 (25th-75th percentiles, 46-73) years, and 9 (56%) patients were women. All patients were symptomatic, usually reporting local pain in the foot (100%) and swelling (67%). The most frequent risk factors were cancer (n = 6; 38%) and prior deep vein thrombosis (n = 4; 25%). Overall, 80% of patients received oral anticoagulation and 20% received parenteral anticoagulation for a median of 90 days. Over a median follow-up of 17 months, 2 (12.5%) recurrent venous thromboembolism events were recorded following the discontinuation of anticoagulation. Index vein recanalization occurred in all 15 survivors. One patient died from cancer 2 years after PVT diagnosis. Conclusion: We provided initial information on the clinical characteristics, treatment, and course of PVT, which partly resembles that of distal deep vein thrombosis.

7.
Article in English | MEDLINE | ID: mdl-38765514

ABSTRACT

Objectives: This study aims to correlate pelvic ultrasound with female puberty and evaluate the usual ultrasound parameters as diagnostic tests for the onset of puberty and, in particular, a less studied parameter: the Doppler evaluation of the uterine arteries. Methods: Cross-sectional study with girls aged from one to less than eighteen years old, with normal pubertal development, who underwent pelvic ultrasound examination from November 2020 to December 2021. The presence of thelarche was the clinical criterion to distinguish pubescent from non-pubescent girls. The sonographic parameters were evaluated using the ROC curve and the cutoff point defined through the Youden index (J). Results: 60 girls were included in the study. Uterine volume ≥ 2.45mL had a sensitivity of 93%, specificity of 90%, PPV of 90%, NPV of 93% and accuracy of 91% (AUC 0.972) for predicting the onset of puberty. Mean ovarian volume ≥ 1.48mL had a sensitivity of 96%, specificity of 90%, PPV of 90%, NPV of 97% and accuracy of 93% (AUC 0.966). Mean PI ≤ 2.75 had 100% sensitivity, 48% specificity, 62% PPV, 100% NPV and 72% accuracy (AUC 0.756) for predicting the onset of puberty. Conclusion: Pelvic ultrasound proved to be an excellent tool for female pubertal assessment and uterine and ovarian volume, the best ultrasound parameters for detecting the onset of puberty. The PI of the uterine arteries, in this study, although useful in the pubertal evaluation, showed lower accuracy in relation to the uterine and ovarian volume.


Subject(s)
Puberty , Humans , Female , Cross-Sectional Studies , Child , Puberty/physiology , Adolescent , Child, Preschool , Uterus/diagnostic imaging , Uterus/blood supply , Infant , Sensitivity and Specificity , Uterine Artery/diagnostic imaging , Ovary/diagnostic imaging , Ovary/blood supply , Pelvis/diagnostic imaging , Pelvis/blood supply , Ultrasonography , ROC Curve
8.
Kidney Int Rep ; 9(4): 1005-1019, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38765580

ABSTRACT

Introduction: We assess if ultrasound surveillance of newly-created arteriovenous fistulas (AVFs) can predict nonmaturation sufficiently reliably to justify randomized controlled trial (RCT) evaluation of ultrasound-directed salvage intervention. Methods: Consenting adults underwent blinded fortnightly ultrasound scanning of their AVF after creation, with scan characteristics that predicted AVF nonmaturation identified by logistic regression modeling. Results: Of 333 AVFs created, 65.8% matured by 10 weeks. Serial scanning revealed that maturation occurred rapidly, whereas consistently lower fistula flow rates and venous diameters were observed in those that did not mature. Wrist and elbow AVF nonmaturation could be optimally modeled from week 4 ultrasound parameters alone, but with only moderate positive predictive values (PPVs) (wrist, 60.6% [95% confidence interval, CI: 43.9-77.3]; elbow, 66.7% [48.9-84.4]). Moreover, 40 (70.2%) of the 57 AVFs that thrombosed by week 10 had already failed by the week 4 scan, thus limiting the potential of salvage procedures initiated by that scan's findings to alter overall maturation rates. Modeling of the early ultrasound characteristics could also predict primary patency failure at 6 months; however, that model performed poorly at predicting assisted primary failure (those AVFs that failed despite a salvage attempt), partly because patency of at-risk AVFs was maintained by successful salvage performed without recourse to the early scan data. Conclusion: Early ultrasound surveillance may predict fistula maturation, but is likely, at best, to result in only very modest improvements in fistula patency. Power calculations suggest that an impractically large number of participants (>1700) would be required for formal RCT evaluation.

9.
J Nippon Med Sch ; 91(2): 227-232, 2024.
Article in English | MEDLINE | ID: mdl-38777783

ABSTRACT

BACKGROUND: Detective flow imaging (DFI) is a new imaging technology that displays low-velocity blood flow, which is difficult to visualize on conventional color Doppler ultrasonography (CDU). In this study, we compared the usefulness of DFI with that of CDU and methoxy-isobutyl-isonitrile (MIBI) scintigraphy for detecting parathyroid adenoma (PA) in patients with primary hyperparathyroidism (PHPT). METHODS: From March 2021 to March 2023, 87 PHPT patients underwent surgery, and 66 had a single PA. We performed preoperative conventional ultrasonography with CDU, MIBI scintigraphy, and DFI for 42 patients (5 males and 37 females; mean age: 61.6 ± 15.4 years). RESULTS: MIBI scintigraphy detected PA in 85.7% (36/42) patients, and both CDU and DFI detected PA in all patients. The rates of vascularity in PA detected by CDU and DFI were 71.4% (30/42) and 85.7% (36/42), respectively. Vascularity was detected by DFI in 6 patients who were negative for vascularity on MIBI scintigraphy. Furthermore, DFI detected blood supply in 6 of the 12 patients with undetectable blood supply on CDU. Fisher's exact test revealed that high or low blood flow, as determined by DFI, was significantly associated with detection of feeding vessels in PA by CDU (P < 0.001). CONCLUSIONS: DFI was useful for preoperative detection of PA blood flow.


Subject(s)
Adenoma , Hyperparathyroidism, Primary , Parathyroid Neoplasms , Ultrasonography, Doppler, Color , Humans , Female , Male , Middle Aged , Parathyroid Neoplasms/diagnostic imaging , Parathyroid Neoplasms/surgery , Parathyroid Neoplasms/complications , Hyperparathyroidism, Primary/diagnostic imaging , Hyperparathyroidism, Primary/surgery , Aged , Ultrasonography, Doppler, Color/methods , Adenoma/diagnostic imaging , Radionuclide Imaging/methods , Technetium Tc 99m Sestamibi , Adult , Blood Flow Velocity
10.
J Anim Sci ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38785319

ABSTRACT

Fall-calving primiparous beef females [body weight (BW): 451 ± 28 (SD) kg; body condition score (BCS): 5.4 ± 0.7] were individually-fed either 100% (control; CON; n = 13) or 70% (nutrient restricted; NR; n = 13) of metabolizable energy and metabolizable protein requirements for maintenance, pregnancy, and growth from day 160 of gestation to parturition. Doppler ultrasonography of both uterine arteries was conducted pre-treatment and every 21 d from days 181 to 265 of gestation. Expelled placentas were collected, and ipsilateral cotyledonary tissue was sampled to assess relative messenger ribonucleic acid (mRNA) expression. Placentas were separated into ipsilateral and contralateral sides, dissected (cotyledonary vs. intercotyledonary), and dried. Data were analyzed with nutritional plane, treatment initiation date, and calf sex (when P < 0.25) as fixed effects. Uterine blood flow included day and nutritional plane × day as repeated measures. We previously reported that post-calving, NR dams weighed 64 kg less and were 2.0 BCS lower than CON, but calf birth weight was not affected. Maternal heart rate was less (P < 0.001) for NR dams than CON after nutritional planes began. Nutritional plane did not affect (P ≥ 0.20) uterine artery hemodynamics, but all variables were affected (P ≤ 0.04) by day. Contralateral cotyledonary and placental weight were less (P ≤ 0.04) and contralateral intercotyledonary weight and number of cotyledons tended to be less (P ≤ 0.10) for NR dams than CON, but ipsilateral and whole placental weights were not affected (P ≥ 0.13). Ipsilateral placental weight as a percentage of total placental weight was greater (P = 0.03) for NR dams than CON. Whole placental cotyledonary:intercotyledonary weight was less (P = 0.01) for NR dams than CON. Placental efficiency was not affected (P = 0.89) by nutritional plane. Cotyledonary relative mRNA expression of GLUT3 and SNAT2 was greater (P ≤ 0.05) and relative expression of GLUT1, GLUT4, and NOS3 tended to be greater (P ≤ 0.07) for NR dams than CON. Nutritional plane did not affect (P ≥ 0.13) relative mRNA expression of GLUT5, 4F2hc, CAT1, LAT1, LAT2, VEGFA, FLT1, KDR, GUCY1B3, and PAG2. Despite less contralateral placental growth, beef heifers experiencing late gestational nutrient restriction maintained uterine artery blood flow and total placental mass and had 4 nutrient transporters and 1 angiogenic factor upregulated in cotyledons, all which likely contributed to conserving fetal growth.

11.
Neuroimaging Clin N Am ; 34(2): 191-202, 2024 May.
Article in English | MEDLINE | ID: mdl-38604704

ABSTRACT

Ultrasound evaluation of the brain is performed through acoustic windows. Transcranial Doppler has long been used to monitor patients with subarachnoid hemorrhage for cerebral vasospasm. Transcranial color-coded sonography permits parenchymal B-mode imaging and duplex evaluation. Transcranial ultrasound may also be used to assess the risk of delayed cerebral ischemia, screen patients for the presence of elevated intracranial pressure, confirm the diagnosis of brain death, measure midline shift, and detect ventriculomegaly. Transcranial ultrasound should be integrated with other point-of-care ultrasound techniques as an essential skill for the neurointensivist.


Subject(s)
Brain Ischemia , Subarachnoid Hemorrhage , Vasospasm, Intracranial , Humans , Subarachnoid Hemorrhage/diagnostic imaging , Ultrasonography, Doppler, Transcranial/methods , Vasospasm, Intracranial/diagnostic imaging , Brain
12.
J Vasc Surg Venous Lymphat Disord ; 12(4): 101897, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38679143

ABSTRACT

OBJECTIVE: We investigated the feasibility and efficacy of assessing calf perforating veins (PVs) using the ankle pump in a sitting position (AP-sit) method by color Doppler ultrasound. METHODS: We performed a multicenter prospective clinical trial between November 2022 and October 2023. Eligible patients with chronic venous disease and healthy controls were enrolled. The calf PVs were assessed using three different methods: manual compression in a standing position, manual compression in a sitting position, and AP-sit method. The reflux durations and detection rate of incompetent PVs (IPVs) were compared among the three methods. The number and diameter of calf PVs and distribution of IPVs were analyzed. RESULTS: A total of 50 patients with chronic venous disease and 50 healthy controls were included. There were 173 calves analyzed, including 97 healthy calves and 76 calves with chronic venous disease. The number of PVs per calf was higher in the diseased calves (median, 7.0; interquartile range [IQR], 6.0-8.0) than in the healthy calves (median, 5.0; IQR, 3.0-6.0; P < .001). The diameter of IPVs (median, 2.3 mm; IQR, 2.0-3.1 mm) was larger than that of competent PVs (median, 1.4 mm; IQR, 1.2-1.7 mm). Most of the IPVs (78.8%) were located in the medial and posterior middle of the calf. The reflux duration induced by the AP-sit method was greater than that induced by the manual compression methods (P < .001). Although the AP-sit method had a higher detection rate (92.0%) of IPVs than the manual compression methods (71.7% and 74.3% for standing and sitting, respectively; P < .001), especially in the distal lower leg, the manual compression methods found IPVs not found using the AP-sit method. CONCLUSIONS: Diseased calves with chronic venous disease have more PVs than do healthy calves. IPVs are commonly larger than competent PVs, with most IPVs located in the medial and posterior middle of the calf. Most importantly, the AP-sit method provides a convenient and effective approach for assessing the calf PVs, especially those located in the distal calf, as an alternative or complementary method to traditional manual compression, which is valuable in the daily practice of sonographers.


Subject(s)
Feasibility Studies , Sitting Position , Ultrasonography, Doppler, Color , Venous Insufficiency , Prospective Studies , Humans , Female , Male , Middle Aged , Venous Insufficiency/diagnostic imaging , Venous Insufficiency/physiopathology , Chronic Disease , Predictive Value of Tests , Adult , Aged , Patient Positioning , Case-Control Studies , Leg/blood supply , Leg/diagnostic imaging , Veins/diagnostic imaging , Regional Blood Flow
13.
Heliyon ; 10(7): e29242, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38623198

ABSTRACT

Objective: The ultrasonic cardiac output monitor (USCOM), an instrument that monitors the evolution of a patient's hemodynamic status and determines the type of shock, has become an important tool for assessing cardiac pathology and predicting changes in disease, but there are some variations in the instrumental findings for different physical conditions of patients. This article examines whether there are differences in the quality of USCOM waveforms measured in different types of critically ill patients based on clinical characteristics and test parameters. Methods: Baseline data, diagnoses, echocardiograms, ventilation patterns, and USCOM results were retrospectively collected from patients in the emergency intensive care unit. Waveform quality was quantified using the Fremantle score to determine the extent to which age, body mass index (BMI), chronic obstructive pulmonary disease (COPD), respiratory failure, cardiac enlargement, valvular heart disease, and ventilation pattern influenced USCOM waveform quality. Results: Age, body mass index, chronic obstructive pulmonary disease, respiratory failure, right and left heart enlargement, aortic valve disease (excluding aortic stenosis), and ventilation mode did not have a significant effect on USCOM waveform quality in critically ill patients (P > 0.05). Conclusions: Various physical conditions of critically ill patients may have limited effect on the quality of the USCOM waveform, potentially rendering USCOM suitable for early assessment of hemodynamic status during ICU admission.

14.
Neurocrit Care ; 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38429611

ABSTRACT

There is an urgent unmet need for a reliable noninvasive tool to detect elevations in intracranial pressure (ICP) above guideline-recommended thresholds for treatment. Gold standard invasive ICP monitoring is unavailable in many settings, including resource-limited environments, and in situations such as liver failure in which coagulopathy increases the risk of invasive monitoring. Although a large number of noninvasive techniques have been evaluated, this article reviews the potential clinical role, if any, of the techniques that have undergone the most extensive evaluation and are already in clinical use. Elevations in ICP transmitted through the subarachnoid space result in distension of the optic nerve sheath. The optic nerve sheath diameter (ONSD) can be measured with ultrasound, and an ONSD threshold can be used to detect elevated ICP. Although many studies suggest this technique accurately detects elevated ICP, there is concern for risk of bias and variations in ONSD thresholds across studies that preclude routine use of this technique in clinical practice. Multiple transcranial Doppler techniques have been used to assess ICP, but the best studied are the pulsatility index and the Czosnyka method to estimate cerebral perfusion pressure and ICP. Although there is inconsistency in the literature, recent prospective studies, including an international multicenter study, suggest the estimated ICP technique has a high negative predictive value (> 95%) but a poor positive predictive value (≤ 30%). Quantitative pupillometry is a sensitive and objective method to assess pupillary size and reactivity. Proprietary indices have been developed to quantify the pupillary light response. Limited data suggest these quantitative measurements may be useful for the early detection of ICP elevation. No current noninvasive technology can replace invasive ICP monitoring. Where ICP monitoring is unavailable, multimodal noninvasive assessment may be useful. Further innovation and research are required to develop a reliable, continuous technique of noninvasive ICP assessment.

15.
Stroke ; 55(5): 1235-1244, 2024 May.
Article in English | MEDLINE | ID: mdl-38511386

ABSTRACT

BACKGROUND: The relationship between dynamic cerebral autoregulation (dCA) and functional outcome after acute ischemic stroke (AIS) is unclear. Previous studies are limited by small sample sizes and heterogeneity. METHODS: We performed a 1-stage individual patient data meta-analysis to investigate associations between dCA and functional outcome after AIS. Participating centers were identified through a systematic search of the literature and direct invitation. We included centers with dCA data within 1 year of AIS in adults aged over 18 years, excluding intracerebral or subarachnoid hemorrhage. Data were obtained on phase, gain, coherence, and autoregulation index derived from transfer function analysis at low-frequency and very low-frequency bands. Cerebral blood velocity, arterial pressure, end-tidal carbon dioxide, heart rate, stroke severity and sub-type, and comorbidities were collected where available. Data were grouped into 4 time points after AIS: <24 hours, 24 to 72 hours, 4 to 7 days, and >3 months. The modified Rankin Scale assessed functional outcome at 3 months. Modified Rankin Scale was analyzed as both dichotomized (0 to 2 versus 3 to 6) and ordinal (modified Rankin Scale scores, 0-6) outcomes. Univariable and multivariable analyses were conducted to identify significant relationships between dCA parameters, comorbidities, and outcomes, for each time point using generalized linear (dichotomized outcome), or cumulative link (ordinal outcome) mixed models. The participating center was modeled as a random intercept to generate odds ratios with 95% CIs. RESULTS: The sample included 384 individuals (35% women) from 7 centers, aged 66.3±13.7 years, with predominantly nonlacunar stroke (n=348, 69%). In the affected hemisphere, higher phase at very low-frequency predicted better outcome (dichotomized modified Rankin Scale) at <24 (crude odds ratios, 2.17 [95% CI, 1.47-3.19]; P<0.001) hours, 24-72 (crude odds ratios, 1.95 [95% CI, 1.21-3.13]; P=0.006) hours, and phase at low-frequency predicted outcome at 3 (crude odds ratios, 3.03 [95% CI, 1.10-8.33]; P=0.032) months. These results remained after covariate adjustment. CONCLUSIONS: Greater transfer function analysis-derived phase was associated with improved functional outcome at 3 months after AIS. dCA parameters in the early phase of AIS may help to predict functional outcome.

16.
J Vasc Bras ; 23: e20230119, 2024.
Article in English | MEDLINE | ID: mdl-38487516

ABSTRACT

Background: Revascularization surgery is used to attempt to restore blood flow to the foot in patients with critical ischemia (CI) caused by peripheral arterial occlusive disease of the lower limbs (LL). Ultrasonography with Doppler (USD) SAH emerged in recent years as a highly valuable method for planning this surgical intervention. Objectives: To evaluate the relationship between the resistance index (RI), measured with USD, and immediate hemodynamic success of LL revascularization surgery in patients with CI. Methods: The study design was a prospective cohort assessing 46 patients with LL CLI who underwent operations to perform infrainguinal revascularization by angioplasty or bypass from August 2019 to February 2022. All patients underwent preoperative clinical vascular assessment with USD including measurement of the RI of distal LL arteries, LL arteriography, and measurement of the ankle-brachial index (ABI). All patients had their ABI measured again in the immediate postoperative period. Results: Forty-six patients were assessed, 25 (54.3%) of whom were male. Age varied from 32 to 89 years (mean: 67.83). Hemodynamic success was assessed by comparison of preoperative and postoperative ABI, showing that hemodynamic success was achieved in 31 (67.4%) patients after revascularization surgery (ABI increased by 0.15 or more). A positive correlation (p ≤ 0.05) was observed between the RI of the distal revascularized LL artery and immediate hemodynamic success assessed by ABI (lower RI and hemodynamic success). Conclusions: This study observed a positive correlation between the resistance index of the distal artery and immediate hemodynamic success of lower limb revascularizations, as assessed by the ankle-brachial index, so that the lower the RI the greater the hemodynamic success achieved.

17.
Cureus ; 16(2): e54920, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38544613

ABSTRACT

Cesarean scar ectopic pregnancy is one of the rarest of all ectopic pregnancies. Cesarean scar ectopic can occur after previous uterine manipulation, in vitro fertilization, hysterotomy, etc. With the increasing number of cesarean sections, the incidence of cesarean scar ectopics has increased worldwide. A high degree of suspicion over the occurrence of ectopic pregnancy after a cesarean section should be maintained by all healthcare workers. Timely diagnosis and treatment according to the presentation of an individual is of utmost importance. Here, we present a case of a 24-year-old second gravida with nine weeks of amenorrhea and a previous cesarean section presenting with the possibility of a scar ectopic, initially managed with medical management, followed by a planned laparotomy.

18.
Int J Reprod Biomed ; 22(1): 69-80, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38544665

ABSTRACT

Background: Pre-eclampsia (PE) is a multiorgan disorder that affects 2-5% of all pregnant women. Present recommendations for when to start aspirin in high-risk women are after 11 wk of gestation. Objective: We present a protocol to investigate the effectiveness of aspirin use from early pregnancy, which is a randomized controlled trial to assess whether prescribed low-dose aspirin from early pregnancy reduces the prevalence of early and late-onset PE. Additionally, to compare the effectiveness of aspirin administration before and after 11 wk in reducing the occurrence of PE? Materials and Methods: All pregnancies at risk of PE, according to demographic and midwifery history, who are referred to the Maternal-Fetal Clinic of Tehran University hospital, Tehran, Iran were invited to take part in the trial. The outcomes of pregnancy and newborns will be gathered and analyzed. The first registration for the pilot study was in January 2023, and the participants were recognized as high-risk for PE. In addition, enrollment in the main study will begin as of October 2023.

19.
Medicina (Kaunas) ; 60(3)2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38541101

ABSTRACT

Background and Objectives: Unstable atherosclerotic plaque in the arteries is one of the main risk factors for cerebral ischemia. Duplex ultrasound is a frequently used diagnostic method, but it has some limitations for microvascularization and neovascularization evaluation. The aim of this review was to evaluate the role of the new multiparametric US method-contrast-enhanced ultrasound (CEUS)-in atherosclerotic plaque instability verification. Materials and Methods: Original studies, reviews, and meta-analyses were included in this article. A total of 53 studies were retrieved; 29 were included in this study. Results: Carotid artery CEUS as a part of the multiparametric ultrasound method shows promising results and provides additional characteristics of soft- and high-risk atherosclerotic plaques; it can be advised in clinical practice for patients with carotid artery soft- and high-risk plaques. However, there are some limitations, such as extensive calcinosis with important acoustic shadows in carotid atherosclerotic plaque neovascularization diagnostics by CEUS. The added value of CEUS in the characterization of atherosclerotic plaque is that it indicates regions with high neovascularization and visualizes ulcerations on plaque surfaces, suggestive of increased instability risk.


Subject(s)
Carotid Stenosis , Plaque, Atherosclerotic , Humans , Plaque, Atherosclerotic/diagnostic imaging , Carotid Stenosis/diagnostic imaging , Contrast Media , Carotid Arteries/diagnostic imaging , Ultrasonography
20.
Indian J Otolaryngol Head Neck Surg ; 76(1): 687-694, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38440618

ABSTRACT

To evaluate the clinical perspective of Veno lymphatic malformation and definitive management in respect to outcome. (1) To discuss clinical presentation, symptomatology of Veno lymphatic malformation. (2) Demonstration of radiological features, diagnosis and management of Veno lymphatic malformation with its complication. This prospective study was conducted on four patients attending ENT-OPD of R.G.Kar Medical College, Kolkata, India who had presented with suspected vascular malformation. The study was conducted from March 2021 to March 2023 for a period of 2 years. The patients were subjected to detailed history and examination. The diagnosis of the Veno lymphatic malformation was based on the results of Doppler ultrasonography, computed tomography and magnetic resonance imaging. In our study there was male predominance. Most of the patients belonged to the 2nd and 3rd decade of life. The main sites of involvement were lateral neck followed by parotid region. The lesion size ranged in between 3.5 × 3.5 cm and 7 × 5 cm. The patient with parotid lesion was found to have phlebolith. Since most of the lesions were small with well-defined margins, we were able to excise the lesions completely without leaving any residue. Out of four cases one patient developed temporary paresis of spinal accessory nerve which resolved eventually. Veno lymphatic malformations are rare and there is no definitive protocol for management and to be individualized. Our study will be helpful for furthering the existing knowledge regarding the management of Veno lymphatic lesion emphasizing the need of multimodality approach in surgical decision making.

SELECTION OF CITATIONS
SEARCH DETAIL
...