1.
Materials (Basel) ; 17(13)2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38998356

ABSTRACT

The abrasive waterjet machining process was introduced in the 1980s as a new cutting tool; the process has the ability to cut almost any material. Currently, the AWJ process is used in many world-class factories, producing parts for use in daily life. A description of this process and its influencing parameters are first presented in this paper, along with process models for the AWJ tool itself and also for the jet-material interaction. The AWJ material removal process occurs through the high-velocity impact of abrasive particles, whose tips micromachine the material at the microscopic scale, with no thermal or mechanical adverse effects. The macro-characteristics of the cut surface, such as its taper, trailback, and waviness, are discussed, along with methods of improving the geometrical accuracy of the cut parts using these attributes. For example, dynamic angular compensation is used to correct for the taper and undercut in shape cutting. The surface finish is controlled by the cutting speed, hydraulic, and abrasive parameters using software and process models built into the controllers of CNC machines. In addition to shape cutting, edge trimming is presented, with a focus on the carbon fiber composites used in aircraft and automotive structures, where special AWJ tools and manipulators are used. Examples of the precision cutting of microelectronic and solar cell parts are discussed to describe the special techniques that are used, such as machine vision and vacuum-assist, which have been found to be essential to the integrity and accuracy of cut parts. The use of the AWJ machining process was extended to other applications, such as drilling, boring, milling, turning, and surface modification, which are presented in this paper as actual industrial applications. To demonstrate the versatility of the AWJ machining process, the data in this paper were selected to cover a wide range of materials, such as metal, glass, composites, and ceramics, and also a wide range of thicknesses, from 1 mm to 600 mm. The trends of Industry 4.0 and 5.0, AI, and IoT are also presented.

2.
BMC Res Notes ; 17(1): 197, 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39020384

ABSTRACT

OBJECTIVE: Conical orthopedic drill bits may have the potential to improve the stabilization of orthopedic screws. During perforations, heat energy is released, and elevated temperatures could be related to thermal osteonecrosis. This study was designed to evaluate the thermal behavior of an experimental conical drill bit, when compared to the conventional cylindrical drill, using polyurethane blocks perforations. RESULTS: The sample was divided into two groups, according to the method of drilling, including 25 polyurethane blocks in each: In Group 1, perforations were performed with a conventional orthopedic cylindrical drill; while in Group 2, an experimental conical drill was used. No statistically significant difference was observed in relation to the maximum temperature (MT) during the entire drilling in the groups, however the perforation time (PT) was slightly longer in Group 2. Each drill bit perforated five times and number of perforations was not correlated with a temperature increase, when evaluated universally or isolated by groups. The PT had no correlation with an increase in temperature when evaluating the perforations universally (n = 50) and in Group 1 alone; however, Group 2 showed an inversely proportional correlation for these variables, indicating that, for the conical drill bit, drillings with longer PT had lower MT.


Subject(s)
Polyurethanes , Thermography , Polyurethanes/chemistry , Thermography/methods , Temperature , Orthopedic Procedures/methods , Orthopedic Procedures/instrumentation , Orthopedic Procedures/adverse effects , Equipment Design , Bone Screws
3.
Cureus ; 16(6): e62092, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38989366

ABSTRACT

We aimed to conduct a systematic review of the data in the literature on ovarian reserve and ovarian hormone following laparoscopic ovarian drilling (LOD). The PubMed, ScienceDirect, and ProQuest databases were comprehensively searched using a combination of keywords such as "ovarian reserve", "laparoscopic ovarian drilling", "luteinizing hormone", "follicle-stimulating hormone", "inhibin", "LH/FSH ratio", "ovulation", and "testosterone". All studies involving females of reproductive age who were officially diagnosed with polycystic ovarian syndrome (PCOS) and had undergone LOD with reported data concerning at least one of the following parameters were considered for inclusion: ovarian reserve, anti-Mullerian hormone (AMH), inhibin, follicle-stimulating hormone (FSH), luteinizing hormone (LH), LH/FSH ratio, and testosterone. All the included studies were evaluated by the GRADE scale for bias and their findings were synthesized by four independent coauthors. A total of 38 studies involving 3118 female patients were included. Based on our findings, a significant number of participants experienced spontaneous ovulation along with a significant decrease in ovarian reserve, and a significant decrease in AMH, LH, and testosterone, with no significant changes in FSH and inhibin B. With the end goal of LOD being to improve fertility and pregnancy rates among females with PCOS, it is important to look at the first few steps that enable this. As expected, there was a significant improvement in ovulation while the ovarian reserve decreased. Along with the decrease in ovarian reserve, there was a significant normalization in AMH, LH, and testosterone levels. LOD may exert its main effects through the manipulation of the ovarian reserves.

4.
Laryngoscope ; 2024 Jul 11.
Article in English | MEDLINE | ID: mdl-38989899

ABSTRACT

OBJECTIVES: Training of temporal bone drilling requires more than mastering technical skills with the drill. Skills such as visual imagery, bimanual dexterity, and stress management need to be mastered along with precise knowledge of anatomy. In otorhinolaryngology, these psychomotor skills underlie performance in the drilling of the temporal bone for access to the inner ear in cochlear implant surgery. However, little is known about how psychomotor skills and workload management impact the practitioners' continuous and overall performance. METHODS: To understand how the practitioner's workload and performance unfolds over time, we examine task-evoked pupillary responses (TEPR) of 22 medical students who performed transmastoid-posterior tympanotomy (TMPT) and removal of the bony overhang of the round window niche in a 3D-printed model of the temporal bone. We investigate how students' TEPR metrics (Average Pupil Size [APS], Index of Pupil Activity [IPA], and Low/High Index of Pupillary Activity [LHIPA]) and time spent in drilling phases correspond to the performance in key drilling phases. RESULTS: All TEPR measures revealed significant differences between key drilling phases that corresponded to the anticipated workload. Enlarging the facial recess lasted significantly longer than other phases. IPA captured significant increase of workload in thinning of the posterior canal wall, while APS revealed increased workload during the drilling of the bony overhang. CONCLUSION: Our findings contribute to the contemporary competency-based medical residency programs where objective and continuous monitoring of participants' progress allows to track progress in expertise acquisition. Laryngoscope, 2024.

5.
Ann Work Expo Health ; 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39007362

ABSTRACT

INTRODUCTION: Respirable crystalline silica (RCS) exposures in tanzanite gem mining have been linked to tuberculosis and silicosis among miners. We conducted a plot study to assess RCS exposures and to introduce safer mining practices in one small-scale underground tanzanite mine. MATERIALS AND METHODS: Personal and area air samples for RCS were collected during tanzanite mining operations before and after improved work practices employed to reduce exposures and analyzed using X-ray diffraction. Area samples were collected at the rest area, located approximately 300 m underground and 100 m from other work activities. Improved practices included the use of wet drilling methods and drilling with new bits. RESULTS: A total of 33 personal and 4 area air samples were collected. Pre-intervention, mean exposures for all operations, drilling operations, non-drilling activities, and area samples were 122 mg/m3, 247 mg/m3, 34.3 mg/m3, and 1.95 mg/m3, respectively which exceeded the U.S. OSHA Permissible Exposure Limit (PEL) by 2,440 times for all operations, by 4,946 times for drilling operations, by 686 times for non-drilling activities and 39 times for area samples collected at an underground rest area. The post-intervention results showed a 99% reduction of RCS exposures for wet drilling operations, 98.5% reduction for non-drilling activities, and 36% reduction for area samples. Despite improvements, post-intervention RCS exposures during drilling had a mean of 2.08 mg/m3 or more than 41 times the OSHA PEL. CONCLUSIONS: We successfully piloted a program to work with small-scale tanzanite miners to reduce RCS exposures and raise awareness about the occupational health risks of RCS, though additional measures are recommended to further reduce RCS exposures. Similar programs should be taken to scale throughout underground mining sites in Tanzania and other countries.

6.
Sci Rep ; 14(1): 13853, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38879578

ABSTRACT

To elucidate the distribution law of the multiphase coupling slag discharge flow field in gas-lift reverse circulation during drilling shaft sinking, a numerical analysis model of gas-liquid-solid multiphase coupling slag discharge was established by CFD-DEM (Coupling of computational fluid dynamics and discrete element method) method, taking the drilling of North Wind well in Taohutu Coal Mine as an example. This model presented the distribution of the multiphase flow field in the slag discharge pipe and at the bottom hole, and was validated through experimentation and theoretical analysis. Finally, the impact of factors, including bit rotation speed, gas injection rate, air duct submergence ratio, and mud viscosity on the slag discharge flow field was clarified. The results indicated that the migration of rock slag at the bottom of the well was characterized by "slip, convergence, suspension, adsorption, and lifting". The slag flow in the discharge pipe exhibited the states of "high density, low flow rate" and "low density, high flow rate", respectively. The multiphase fluid flow patterns in the well bottom and slag discharge pipe were horizontal and axial flows, respectively. The model test of the gas lift reversed circulation slag discharge and the theoretical model of the bottom hole fluid velocity distribution confirmed the accuracy of the multiphase coupling slag discharge flow field distribution model. The rotation speed of the drill bit had the most significant impact on the bottom hole flow field. Increasing the rotation speed of the drill bit can significantly enhance the tangential velocity of the bottom hole fluid, increase the pressure difference between the bottom hole and annular mud column, and improve the adsorption capacity of the slag suction port. These findings can provide valuable insights for gas lift reverse circulation well washing in western drilling shaft sinking.

7.
Polymers (Basel) ; 16(11)2024 May 24.
Article in English | MEDLINE | ID: mdl-38891438

ABSTRACT

This paper explores the interaction between cutting parameters and the geometric accuracy of machined holes in a variety of engineering plastics, with the aim of improving manufacturing processes in the plastic processing industry. In the context of fast and precise manufacturing technology, the accuracy of drilled holes in polymers is of paramount importance, given their essential role in the assembly and functionality of finished parts. The objective of this research was to determine the influence of cutting speed and feed rate on the diameter and cylindricity of machined holes in six diverse types of plastics using a multilevel factorial design for analysis. The key message conveyed to the reader highlights that careful selection of cutting parameters is crucial to achieving high standards of accuracy and repeatability in plastic processing. The methodology involved structured experiments, looking at the effect of changing cutting parameters on a set of six polymer materials. A CNC machining center for drills and high-precision measuring machines were used to evaluate the diameter and cylindricity of the holes. The results of ANOVA statistical analysis showed a significant correlation between cutting parameters and hole sizes for some materials, while for others the relationship was less evident. The conclusions drawn highlight the importance of optimizing cutting speed and feed rate according to polymer type to maximize accuracy and minimize deviations from cylindricity. It was also observed that, under selected processing conditions, high- and medium-density polyurethane showed the best results in terms of accuracy and cylindricity, suggesting potential optimized directions for specific industrial applications.

8.
Sci Rep ; 14(1): 12777, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38834688

ABSTRACT

A high-density water-based drilling fluid (WBDF) is crucial for maintaining wellbore stability, controlling formation pressures, and optimizing drilling performance in challenging subsurface conditions. In the present research, the effect of micronized calcium carbonate (calcite), extracted from the Aruma formation outcrop, is evaluated as one of the additives that could be added to the ilmenite-weighted WBDF to enhance and optimize its properties. Various concentrations of Calcite microparticles were introduced into identical fluid formulations to assess their impact. The concentrations ranged from 0, 10, 20, to 30 lb/bbl, providing a comprehensive examination of the effects of calcite microparticles across a spectrum of concentrations within the fluid. The results highlighted that adding Barite microparticles to the WBDF revealed a notable enhancement in rheological properties. Specifically, the yield point demonstrated an increase of 37%, 37%, and 11% for concentrations of 10, 20, and 30 lb/bbl of calcite, respectively. Equally significant, high-pressure-high-temperature (HPHT) filtration analysis indicated a considerable enhancement for the fluids containing calcite microparticles. A reduction of 14.5%, 24.6%, and 13% were observed in HPHT filtrate for concentrations of 10 lb/bbl, 20 lb/bbl, and 30 lb/bbl respectively. Simultaneously, there is a reduction in filter cake thickness by 20%, 40%, and 20%, respectively. No ilmenite settling was observed in the sample containing 20 lb/bbl of calcite, unlike the other concentrations. These diverse results strongly suggest that the optimal concentration for calcite microparticles is 20 lb/bbl. The combined utilization of the optimal concentration of calcite microparticles alongside the established additives proves to be an effective strategy for optimizing the ilmenite-weighted WBDF performance in terms of both thermal stability and rheological behavior.

9.
Lasers Med Sci ; 39(1): 157, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38879698

ABSTRACT

Frequently orthopedic surgeries require mechanical drilling processes especially for inserted biodegradable screws or removing small bone lesions. However mechanical drilling techniques induce large number of forces as well as have substantially lower material removal rates resulting in prolong healing times. This study focuses on analyzing the impact of quasi-continuous laser drilling on the bone's surface as well as optimizing the drilling conditions to achieve high material removal rates. An ex-vivo study was conducted on the cortical region of desiccated bovine bone. The laser-based drilling on the bovine bine specimens was conducted in an argon atmosphere using a number of laser pulses ranging from 100 to 15,000. The morphology of the resulting laser drilled cavities was characterized using Energy dispersive Spectroscopy (EDS) and the width and depth of the drills were measured using a laser based Profilometer. Data from the profilometer was then used to calculate material removal rates. At last, the material removal rates and laser processing parameters were used to develop a statistical model based on Design of Experiments (DOE) approach to predict the optimal laser drilling parameters. The main outcome of the study based on the laser drilled cavities was that as the number of laser pulses increases, the depth and diameter of the cavities progressively increase. However, the material removal rates revealed a decrease in value at a point between 4000 and 6000 laser pulses. Therefore, based on the sequential sum of square method, a polynomial curve to the 6th power was fit to the experimental data. The predicted equation of the curve had a p-value of 0.0010 indicating statistical significance and predicted the maximum material removal rate to be 32.10 mm3/s with 95%CI [28.3,35.9] which was associated with the optimum number of laser pulses of 4820. Whereas the experimental verification of bone drilling with 4820 laser pulses yielded a material removal rate of 33.37 mm3/s. Therefore, this study found that the carbonized layer formed due to laser processing had a decreased carbon content and helped in increasing the material removal rate. Then using the experimental data, a polymetric equation to the sixth power was developed which predicted the optimized material removal rate to occur at 4820 pulses.


Subject(s)
Cortical Bone , Laser Therapy , Animals , Cattle , Cortical Bone/surgery , Cortical Bone/radiation effects , Laser Therapy/methods , Laser Therapy/instrumentation , Spectrometry, X-Ray Emission , Orthopedic Procedures/methods , Orthopedic Procedures/instrumentation
10.
Molecules ; 29(11)2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38893563

ABSTRACT

This study introduces a novel organosilicon-modified polysaccharide (Si-AP) synthesized via grafting and comprehensively evaluates its performance in water-based drilling fluids (WBDFs). The molecular structure of Si-AP was characterized using Fourier-transform infrared spectroscopy (FTIR) and 1H-NMR experiments. Thermalgravimetric analysis (TGA) confirmed the good thermal stability of Si-AP up to 235 °C. Si-AP significantly improves the rheological properties and fluid loss performance of WBDFs. With increasing Si-AP concentration, system viscosity increases, API filtration rate decreases, clay expansion is inhibited, and drilling cuttings hydration dispersion is suppressed, especially under high-temperature conditions. Additionally, mechanistic analysis indicates that the introduction of siloxane groups can effectively inhibit the thermal degradation of AP chains and enhance their high-temperature resistance. Si-AP can form a lubricating film by adsorbing on the surface of clay particles, improving mud cake quality, reducing the friction coefficient, and significantly enhancing the lubricating performance of WBDFs. Overall, Si-AP exhibits a higher temperature-resistance limit compared to AP and more effectively optimizes the lubrication, inhibition, and control of the filtration rate of WBDFs under high-temperature conditions. While meeting the requirements of drilling fluid systems under high temperatures, Si-AP also addresses environmental concerns and holds promise as an efficient solution for the exploitation of deep-seated oil and gas resources.

11.
Materials (Basel) ; 17(11)2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38894039

ABSTRACT

Current research studies devoted to cutting forces in drilling are oriented toward predictive model development, however, in the case of mechanistic models, the material effect on the drilling process itself is mostly not considered. This research study aims to experimentally analyze how the machined material affects the feed force (Ff) during drilling, alongside developing predictive mathematical-statistical models to understand the main effects and interactions of the considered technological and tool factors on Ff. By conducting experiments involving six factors (feed, cutting speed, drill diameter, point angle, lip relief angle, and helix angle) at five levels, the drilling process of stainless steel AISI1045 and case-hardened steel 16MnCr5 is executed to validate the numerical accuracy of the established prediction models (AdjR = 99.600% for C45 and AdjR = 97.912% for 16MnCr5). The statistical evaluation (ANOVA, RSM, and Lack of Fit) of the data proves that the drilled material affects the Ff value at the level of 17.600% (p < 0.000). The effect of feed represents 44.867% in C45 and 34.087% in 16MnCr5; the cutting speed is significant when machining C45 steel only (9.109%). When machining 16MnCr5 compared to C45 steel, the influence of the point angle (lip relief angle) is lower by 49.198% (by 22.509%). The effect of the helix angle is 163.060% higher when machining 16MnCr5.

12.
Micromachines (Basel) ; 15(6)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38930774

ABSTRACT

Micro-electro-mechanical systems inertial measurement units (MEMS-IMUs) are increasingly being employed for measuring the attitude of bottom hole assemblies (BHAs). However, the reliability and measurement precision of a single MEMS-IMU may not meet drilling's stringent needs. Redundant MEMS-IMU systems can effectively enhance the reliability and precision. This paper proposes a redundant configuration method for MEMS sensors tailored to BHA attitude measurement. Firstly, based on reliability theory and a cost-benefit analysis, considering factors such as cost, size, and reliability, the optimal number of sensors in the redundant system was determined to be six. Considering the structural characteristics of the BHA, a hollow hexagonal prism-shaped redundant configuration scheme was proposed, ensuring the circulation of drilling fluid within the drill pipe. Next, by employing Kalman filtering to integrate the output data from the six sensors, a virtual IMU (VIMU) was formed. Finally, experimental verification was carried out. The results confirmed that, after redundancy implementation, the velocity random walk of the accelerometer decreased by an average of 58% compared to a single MEMS-IMU, and bias instability was reduced by an average of 54%. The angular random walk of the gyroscope decreased by an average of 58%, and bias instability was reduced by an average of 37%. This research provides a theoretical foundation for enhancing the precision and reliability of BHA attitude measurements.

13.
Molecules ; 29(12)2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38930887

ABSTRACT

Laponite® (LAP) is an intensively studied synthetic clay due to the versatility given by its layered structure, which makes it usable in various applications. This review describes the multifaceted properties and applications of LAP in aqueous dispersions and gel systems. The first sections of the review discuss the LAP structure and the interactions between clay discs in an aqueous medium under different conditions (such as ionic strength, pH, temperature, and the addition of polymers) in order to understand the function of clay in tailoring the properties of the designed material. Additionally, the review explores the aging phenomenon characteristic of LAP aqueous dispersions as well as the development of shake-gels by incorporating LAP. The second part shows the most recent studies on materials containing LAP with possible applicability in the drilling industry, cosmetics or care products industry, and biomedical fields. By elucidating the remarkable versatility and ease of integration of LAP into various matrices, this review underscores its significance as a key ingredient for the creation of next-generation materials with tailored functionalities.

14.
Molecules ; 29(12)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38930997

ABSTRACT

In the development of ultra-deep wells, extremely high temperatures can lead to inefficiency of additives in drilling fluids. Hence, there is a need to prepare additives with a simple preparation process and good effects at ultra-high temperatures to ensure stable drilling fluid performance. In this study, a high temperature resistant filtration loss polymer (LY-2) was prepared using γ-methacryloyloxypropyltrimethoxysilane (KH570), N,N-dimethylallyl ammonium chloride (DMDAAC), sodium p-styrenesulfonate (SSS), and ß-cyclodextrin (ß-CD). The impact of the different monomer ratios on particle size, rheology, and filtration performance was systematically investigated. Infrared spectroscopy afforded the structural features. Thermogravimetric Analysis detected the temperature stability, and scanning electron microscopy characterized the polymer micromorphology. LY-2 was completely decomposed at a temperature above 600 °C. Experiments showed FLAPI of the drilling fluid containing 3% LY-2 aged at 260 °C/16 h was only 5.1 mL, which is 85.4% lower compared to the base fluid. This is attributed to the synergistic effect of the polymer adsorption through chemical action at high temperatures and the blocking effect of carbon nanoparticles on the filter cake released by cyclodextrin carbonization at high temperatures. Comparing LY-2 with commercial filter loss reducers shows that LY-2 has excellent temperature resistance, which exhibited five times higher filtration performance and relatively low cost, making it possible to be applied to ultra-high temperature drilling operations in an industrial scale-up.

15.
Heliyon ; 10(11): e32319, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38912511

ABSTRACT

This study aims to prevent ice accumulation on the surface of drilling tools by investigating the effectiveness of hydrophobic coatings, which is one of the most promising methods to solve drilling difficulties in warm ice. Herein, four types of hydrophobic organic coatings that can be used on metal surfaces were tested to evaluate their anti-icing performance, service durability, and friction properties. All of them possess rough surfaces with microstructure characteristics such as pores, stripes, or micropapillae. They also exhibit hydrophobicity, with water contact angles of 101.6°, 100.0°, 103.1°, and 108.5°. They can significantly prolong the required freezing time of water droplets on their surfaces, effectively reduce ice adhesion, and decrease the friction between ice and their surface. The ice adhesion in the axial, tensile, and tangential directions can be reduced by 65.64 %, 56.31 %, and 72.11 %, respectively, for the coating with silicon (Si)-based and fluorine (F)-containin compounds (coating-C) at -30 °C; while it can be reduced by 85.05 %, 73.9 %, and 94.2 %, respectively, for the coatings with Si-based and polytetrafluoroethylene (PTFE) compounds (coating-D). The two coatings mentioned above lose their anti-icing performance after 20 icing and de-icing cycles, and their hydrophobicity after 120 abrasion cycles under a load of 6 N.

16.
Neurosurg Rev ; 47(1): 293, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38914867

ABSTRACT

BACKGROUND: The bone holes in the skull during surgical drainage were accurately located at the site of the MMA. The MMA was severed, and the hematoma was removed intraoperatively; furthermore, surgical drainage removed the pathogenic factors of CSDH. This study aimed to describe and compare the results of the new treatment with those of traditional surgical drainage, and to investigate the relevance of this approach. METHODS: From December 2021 to June 2023, 72 patients were randomly assigned to the observation group and the control group. The control group was treated with traditional surgical drainage, while the observation group was treated with DSA imaging to accurately locate the bone holes drilled in the skull on the MMA trunk before traditional surgical drainage. The MMA trunk was severed during the surgical drainage of the hematoma. The recurrence rate, time of indwelling drainage tube, complications, mRS, and other indicators of the two groups were compared, and the changes of cytokine components and imaging characteristics of the patients were collected and analyzed. RESULTS: Overall, 27 patients with 29-side hematoma in the observation group and 45 patients with 48-side hematoma in the control group were included in the study. The recurrence rate was 0/29 in the observation group and 4/48 in the control group, indicating that the recurrence rate in the observation group was lower than in the control group (P = .048). The mean indwelling time of the drainage tube in the observation group was 2.04 ± 0.61 days, and that in the control group was 2.48 ± 0.61 days. The indwelling time of the drainage tube in the observation group was shorter than in the control group (P = .003). No surgical complications were observed in the observation group or the control group. The differences in mRS scores before and after operation between the observation group and the control group were statistically significant (P < .001). The concentrations of cytokine IL6/IL8/IL10/VEGF in the hematoma fluid of the observation and control groups were significantly higher than those in venous blood (P < .001). After intraoperative irrigation and drainage, the concentrations of cytokines (IL6/IL8/IL10/VEGF) in the subdural hematoma fluid were significantly lower than they were preoperatively. In the observation group, the number of MMA on the hematoma side (11/29) before STA development was higher than that on the non-hematoma side (1/25), and the difference was statistically significant (P = .003). CONCLUSION: In patients with CSDH, accurately locating the MMA during surgical trepanation and drainage, severing the MMA during drainage, and properly draining the hematoma, can reduce the recurrence rate and retention time of drainage tubes, thereby significantly improving the postoperative mRS Score without increasing surgical complications.


Subject(s)
Drainage , Hematoma, Subdural, Chronic , Meningeal Arteries , Humans , Hematoma, Subdural, Chronic/surgery , Male , Drainage/methods , Female , Aged , Middle Aged , Treatment Outcome , Meningeal Arteries/surgery , Adult , Aged, 80 and over , Craniotomy/methods
17.
Bioengineering (Basel) ; 11(6)2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38927828

ABSTRACT

Bone drilling is a common procedure used to create pilot holes for inserting screws to secure implants for fracture fixation. However, this process can increase bone temperature and the excessive heat can lead to cell death and thermal osteonecrosis, potentially causing early fixation failure or complications. We applied a three-dimensional dynamic elastoplastic finite element model to evaluate the propagation and distribution of heat during bone drilling and assess the thermally affected zone (TAZ) that may lead to thermal necrosis. This model investigates the parameters influencing bone temperature during bone drilling, including drill diameter, rotational speed, feed force, and predrilled hole. The results indicate that our FE model is sufficiently accurate in predicting the temperature rise effect during bone drilling. The maximum temperature decreases exponentially with radial distance. When the feed forces are 40 and 60 N, the maximum temperature does not exceed 45 °C. However, with feed forces of 10 and 20 N, both the maximum temperatures exceed 45 °C within a radial distance of 0.2 mm, indicating a high-risk zone for potential thermal osteonecrosis. With the two-stage drilling procedure, where a 2.5 mm pilot hole is predrilled, the maximum temperature can be reduced by 14 °C. This suggests that higher feed force and rotational speed and/or using a two-stage drilling process could mitigate bone temperature elevation and reduce the risk of thermal osteonecrosis during bone drilling.

18.
Bioengineering (Basel) ; 11(6)2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38927866

ABSTRACT

The estimation of distances and angles is a routine part of an orthopedic surgical procedure. However, despite their prevalence, these steps are most often performed manually, heavily relying on the surgeon's skill and experience. To address these issues, this study presents a sensor-equipped drill system which enables automatic estimation of the drilling angle and channel length. The angular accuracy and precision of the system were tested over a range of inclination angles and proved to be superior to the manual approach, with mean absolute errors ranging from 1.9 to 4.5 degrees for the manual approach, and from 0.6 to 1.3 degrees with the guided approach. When sensors were used for simultaneous estimation of both the inclination and anteversion angles, the obtained mean absolute errors were 0.35 ± 0.25 and 2 ± 1.33 degrees for the inclination and anteversion angles, respectively. Regarding channel length estimation, using measurements obtained with a Vernier caliper as a reference, the mean absolute error was 0.33 mm and the standard deviation of errors was 0.41 mm. The obtained results indicate a high potential of smart drill systems for improvement of accuracy and precision in orthopedic surgical procedures, enabling better patient clinical outcomes.

19.
Br J Neurosurg ; : 1-7, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38879778

ABSTRACT

BACKGROUND AND OBJECTIVES: Around 20-40% of trigeminal schwannomas (TS) are dumbbell shaped, spanning the middle and posterior cranial fossa The petrous apex is often truncated in these patients, aiding surgical resection of both compartments through the middle fossa approach. However, a less eroded petrous creates a blind spot, making total resection difficult. This study describes the feasibility of an approach combining expanded Meckel cave access with tailored petrous bone drilling to optimize tumor visualization and resection. METHODS: Eleven patients with dumbbell TS and minimal petrous apex erosion underwent the described surgery. Surgical steps included temporo-orbito-zygomatic craniotomy, middle fossa floor drilling, navigation aided (tailored) extradural petrous bone drilling and extra-arachnoidal tumor excision. Extent of resection and postoperative outcomes were recorded. RESULTS: Patients presented with trigeminal nerve dysfunction (n = 9; sensory -9 and motor - 5), headache(8/11), ataxia (7/11) and pseudobulbar palsy (3/11). Complete tumor resection was achieved in all patients. Postoperatively, 8 out of 9 patients had transient increase in facial hypoesthesia with conjunctival injection in 3. It improved within 3-6 months, except in four cases wherein mild hypoesthesia persisted. Motor symptoms improved in 2 of 5 patients. Two developed transient 6th nerve paresis, that resolved in 2 months. Cerebellar and brainstem pressure symptoms resolved in all. No patients developed new onset permanent neurological deficit. Two patients reported mild post-craniotomy masticatory difficulty. CONCLUSIONS: The additional tailored petrous bony drilling enhances the surgeon's view, allowing a higher chance of total resection with no major operative morbidity.

20.
Sensors (Basel) ; 24(12)2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38931792

ABSTRACT

The compression method for wellbore trajectory data is crucial for monitoring wellbore stability. However, classical methods like methods based on Huffman coding, compressed sensing, and Differential Pulse Code Modulation (DPCM) suffer from low real-time performance, low compression ratios, and large errors between the reconstructed data and the source data. To address these issues, a new compression method is proposed, leveraging a deep autoencoder for the first time to significantly improve the compression ratio. Additionally, the method reduces error by compressing and transmitting residual data from the feature extraction process using quantization coding and Huffman coding. Furthermore, a mean filter based on the optimal standard deviation threshold is applied to further minimize error. Experimental results show that the proposed method achieves an average compression ratio of 4.05 for inclination and azimuth data; compared to the DPCM method, it is improved by 118.54%. Meanwhile, the average mean square error of the proposed method is 76.88, which is decreased by 82.46% when compared to the DPCM method. Ablation studies confirm the effectiveness of the proposed improvements. These findings highlight the efficacy of the proposed method in enhancing wellbore stability monitoring performance.