ABSTRACT
Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.
Resumo Fundamento: O implante de válvula aórtica por cateter tornou-se uma opção para pacientes com doença valvar aórtica de elevado risco cirúrgico. Objetivo: Avaliar os resultados dos seguimentos intra-hospitalar e de até 1 ano do implante de válvula aórtica por cateter. Métodos: Estudo de coorte prospectiva de casos de implante de válvula aórtica por cateter entre julho de 2009 e fevereiro de 2015. Análise de variáveis clínicas e do procedimento, correlacionando com mortalidade intra-hospitalar e de 1 ano. Resultados: Foram submetidos ao implante 136 pacientes, com média de idade de 83 (80-87) anos, sendo 49% mulheres, 131 (96,3%) deles com estenose aórtica, um (0,7%) com insuficiência aórtica e quatro (2,9%) com disfunção de prótese. A classe funcional da NYHA foi III ou IV em 129 (94,8%) casos. A área valvar inicial foi 0,67 ± 0,17 cm2 e o gradiente ventrículo esquerdo-aorta médio de 47,3 ± 18,2 mmHg, com STS de 9,3% (4,8%-22,3%). As próteses implantadas eram autoexpansíveis em 97% dos casos. A mortalidade peroperatória em 1,5% dos casos; em 30 dias em 5,9%; intra-hospitalar em 8,1%; e após 1 ano em 15,5% dos casos. A hemotransfusão (risco relativo de 54; p = 0,0003) e a hipertensão arterial pulmonar (risco relativo de 5,3; p = 0,036) foram preditoras de mortalidade hospitalar; e a proteína C-reativa pico (risco relativo de 1,8; p = 0,013) e a hemotransfusão (risco relativo de 8,3; p = 0,0009) de mortalidade em 1 ano. Aos 30 dias, 97% dos pacientes estavam em classe NYHA I/II e, em 1 ano, o número chegou a 96%. Conclusão: O implante de válvula aórtica por cateter foi realizado com alto índice de sucesso e baixa mortalidade. A hemotransfusão associou-se com maior mortalidade hospitalar e de 1 ano. Proteína C-reativa pico se associou com a mortalidade de 1 ano.
Subject(s)
Humans , Male , Female , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/surgery , Hospital Mortality , Transcatheter Aortic Valve Replacement/mortality , Aortic Valve Insufficiency/epidemiology , Aortic Valve Stenosis/epidemiology , Postoperative Complications/mortality , Time Factors , Brazil/epidemiology , Epidemiologic MethodsABSTRACT
AbstractBackground:Predicting mortality in patients undergoing transcatheter aortic valve implantation (TAVI) remains a challenge.Objectives:To evaluate the performance of 5 risk scores for cardiac surgery in predicting the 30-day mortality among patients of the Brazilian Registry of TAVI.Methods:The Brazilian Multicenter Registry prospectively enrolled 418 patients undergoing TAVI in 18 centers between 2008 and 2013. The 30-day mortality risk was calculated using the following surgical scores: the logistic EuroSCORE I (ESI), EuroSCORE II (ESII), Society of Thoracic Surgeons (STS) score, Ambler score (AS) and Guaragna score (GS). The performance of the risk scores was evaluated in terms of their calibration (Hosmer–Lemeshow test) and discrimination [area under the receiver–operating characteristic curve (AUC)].Results:The mean age was 81.5 ± 7.7 years. The CoreValve (Medtronic) was used in 86.1% of the cohort, and the transfemoral approach was used in 96.2%. The observed 30-day mortality was 9.1%. The 30-day mortality predicted by the scores was as follows: ESI, 20.2 ± 13.8%; ESII, 6.5 ± 13.8%; STS score, 14.7 ± 4.4%; AS, 7.0 ± 3.8%; GS, 17.3 ± 10.8%. Using AUC, none of the tested scores could accurately predict the 30-day mortality. AUC for the scores was as follows: 0.58 [95% confidence interval (CI): 0.49 to 0.68, p = 0.09] for ESI; 0.54 (95% CI: 0.44 to 0.64, p = 0.42) for ESII; 0.57 (95% CI: 0.47 to 0.67, p = 0.16) for AS; 0.48 (95% IC: 0.38 to 0.57, p = 0.68) for STS score; and 0.52 (95% CI: 0.42 to 0.62, p = 0.64) for GS. The Hosmer–Lemeshow test indicated acceptable calibration for all scores (p > 0.05).Conclusions:In this real world Brazilian registry, the surgical risk scores were inaccurate in predicting mortality after TAVI. Risk models specifically developed for TAVI are required.
ResumoFundamento:Ainda é desafiador prever a mortalidade de pacientes que se submetem ao TAVI (sigla do inglês Transcatheter Aortic Valve Implantation).Objetivos:Avaliar o desempenho de cinco escores de risco para cirurgia cardíaca em prever mortalidade em 30 dias de pacientes inscritos no Registro Brasileiro de TAVI.Métodos:O Registro Multicêntrico Brasileiro inscreveu prospectivamente 418 pacientes submetidos ao TAVI em 18 centros entre 2008 e 2013. Os seguintes escores cirúrgicos foram usados para calcular o risco de mortalidade no período de 30 dias: EuroSCORE I (ESI) logístico, EuroSCORE II (ESII), STS Score (STS), Ambler Score (AS) e Guaragna Score (GS). O desempenho dos escores de risco foram avaliados através de sua calibração (teste Hosmer-Lemeshow) e discriminação [área sob a curva (AUC) do inglês receiver-operating characteristic curve)].Resultados:A idade média foi de 81,5 ± 7,7 anos. A prótese aórtica CoreValve (Medtronic) foi usada em 86,1% da coorte e a abordagem transfemural usada em 96,2%. A mortalidade observada no período de 30 dias foi de 9,1%. A mortalidade no período de 30 dias prevista pelos escores foi: ESI, 20,2 ± 13,8%; ESII, 6,5 ± 13,8%; STS, 14,7 ± 4,4%; AS, 7,0 ± 3,8%; GS, 17,3 ± 10,8%. Nenhum dos escores testados com a AUC foi capaz de prever a mortalidade no período de 30 dias de forma precisa. As AUC para os escores foram: 0,58 [95% de intervalo de confiança (IC): 0,49 a 0,68, p = 0,09] para ESI; 0,54 (IC de 95%: 0,44 a 0,64, p = 0,42) para ESII; 0,57 (IC de 95%: 0,47 a 0,67, p = 0,16) para AS; 0,48 (IC de 95%: 0,38 a 0,57, p = 0,68) para STS e 0,52 (IC de 95%: 0,42 a 0,62, p = 0,64) para GS. O teste Hosmer-Lemeshow indicou uma calibração aceitável para todos os escores (p > 0,05).Conclusões:Neste registro brasileiro de mundo real, os escores de risco cirúrgico foram imprecisos para prever a mortalidade após o TAVI. São necessários modelos de risco desenvolvidos especificamente para o TAVI.