Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Language
Publication year range
1.
Article in Chinese | MEDLINE | ID: mdl-30248754

ABSTRACT

Objective: A solvent desorption-gas chromatography method for determination of ethylal in workplace air has been established. Methods: Ethylal in workplace air was collected by activated carbon tube and desorbed with carbon disulfide, and the desorption solutions were analysed by capillary column GC with FID detector. Results: The method presented a good linearity in the range of 0.87~34 800.00 mg/L of ethylal in the standard solution, with the correlation coefficient being r=0.999 7. The limit of detection and the limit of quantification of this method were respectively 0.20 mg/L and 0.80 mg/L, and the minimum detectable concentration and the minimum quantification concentration of this method were respectively 0.17 mg/m(3) and 0.60 mg/m(3) per 1.50 L of air.The within-run precision of the method was 2.93%-6.20%, and the between-run precision 3.67%-6.44%. The desorption efficiency between 94.22%-97.27%. Ethylal in activated carbon tube could be kept at least 7 days at room temperature without significant loss. Conclusion: The method could be used for determination of ethylal in workplace air.


Subject(s)
Air Pollutants, Occupational/analysis , Chromatography, Gas/methods , Workplace , Carbon Disulfide , Humans , Solvents
2.
Article in Chinese | WPRIM (Western Pacific) | ID: wpr-806625

ABSTRACT

Objective@#A solvent desorption-gas chromatography method for determination of ethylal in workplace air has been established.@*Methods@#Ethylal in workplace air was collected by activated carbon tube and desorbed with carbon disulfide, and the desorption solutions were analysed by capillary column GC with FID detector.@*Results@#The method presented a good linearity in the range of 0.87~34 800.00 mg/L of ethylal in the standard solution, with the correlation coefficient being r=0.999 7. The limit of detection and the limit of quantification of this method were respectively 0.20 mg/L and 0.80 mg/L, and the minimum detectable concentration and the minimum quantification concentration of this method were respectively 0.17 mg/m3 and 0.60 mg/m3 per 1.50 L of air.The within-run precision of the method was 2.93%-6.20%, and the between-run precision 3.67%-6.44%. The desorption efficiency between 94.22%-97.27%. Ethylal in activated carbon tube could be kept at least 7 days at room temperature without significant loss.@*Conclusion@#The method could be used for determination of ethylal in workplace air.

SELECTION OF CITATIONS
SEARCH DETAIL