Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Language
Publication year range
1.
Thorac Cardiovasc Surg Rep ; 11(1): e30-e32, 2022 Jan.
Article in English | MEDLINE | ID: mdl-35761984

ABSTRACT

Background The management of aortic lesions involving the aortic arch in patients who cannot tolerate thoracotomy is a challenge. Case Description A 32-year-old woman who underwent a giant aneurysm at the proximal end of the descending aorta with significant vascular wall calcification. The patient underwent Castor single-branched stent-grafting in the brachiocephalic trunk combined with surgical supra-aortic debranching, which avoided surgical aortic arch replacement and stent fenestration.reopening. The patient was followed up for 9 months, and surgery-related complications were not observed. Conclusion Hybrid arch repair with supra-aortic debranching and using Castor single-branched stent can be used to treat aortic lesions involving the aortic arch.

2.
Rev. bras. cir. cardiovasc ; 36(4): 561-564, July-Aug. 2021. tab, graf
Article in English | LILACS | ID: biblio-1347157

ABSTRACT

Abstract Patients with complex Stanford type B aortic dissection are very difficult to treat. Many methods have been proposed so far in the treatment of these patients, and the emergence of hybrid techniques has made the treatment easier. In this article, we shared the extra-anatomical bypass (aorto-celiac-mesenteric bypass) + thoracic endovascular aortic repair + cholecystectomy operation technique applied to a patient with complex type B aortic dissection.


Subject(s)
Humans , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Blood Vessel Prosthesis , Cholecystectomy , Retrospective Studies , Dissection
3.
Braz J Cardiovasc Surg ; 36(4): 561-564, 2021 08 06.
Article in English | MEDLINE | ID: mdl-33355790

ABSTRACT

Patients with complex Stanford type B aortic dissection are very difficult to treat. Many methods have been proposed so far in the treatment of these patients, and the emergence of hybrid techniques has made the treatment easier. In this article, we shared the extra-anatomical bypass (aorto-celiac-mesenteric bypass) + thoracic endovascular aortic repair + cholecystectomy operation technique applied to a patient with complex type B aortic dissection.


Subject(s)
Blood Vessel Prosthesis Implantation , Endovascular Procedures , Blood Vessel Prosthesis , Cholecystectomy , Dissection , Humans , Retrospective Studies , Stents , Treatment Outcome
4.
Thorac Cardiovasc Surg Rep ; 7(1): e21-e23, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29942732

ABSTRACT

Anastomotic leakage of the gastric conduit following surgical treatment of esophageal cancer is a life-threatening complication. An important risk factor associated with anastomotic leakage is calcification of the supplying arteries of the gastric conduit. The patency of calcified splanchnic arteries cannot be assessed on routine computed tomography (CT) scans for esophageal cancer and, as such, in selected patients with known or assumed mesenteric artery disease, additional CT angiography of the abdominal arteries with 1 mm slices is strongly encouraged. If the mesenteric perfusion is compromised in patients with resectable esophageal cancer, angioplasty procedures with stenting of the mesenteric arteries could be performed to prevent possible ischemia of the gastric conduit.

5.
Thorac Cardiovasc Surg Rep ; 7(1): e7-e8, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29515967

ABSTRACT

Endovascular stent placement for chronic postthrombotic iliofemoral venous obstructive lesions is an effective therapeutic option and might be complicated by stent migration. We report a case of a venous stent that was lost from the iliac vein into the right ventricle rescued by emergent open-heart surgery.

6.
Catheter Cardiovasc Interv ; 83(5): E178-82, 2014 Apr 01.
Article in English | MEDLINE | ID: mdl-23197330

ABSTRACT

Transcatheter aortic valve implantation could represent an alternative option to conventional surgery in high-risk patients with degeneration of aortic bioprosthesis. Herein, we report the performance of a valve-in-valve procedure in urgent conditions and via the left axillary artery in a patient with patent left internal mammary artery coronary graft. A 23-mm Edwards Sapien(®) transcatheter valve was deployed within a 23-mm Edwards Magna Ease bioprosthesis through the novel Edwards 16-F expandable introducer. In this non-elective case, the expandable introducer allowed a safe procedure, reduced the risk of subclavian injury, and preserved the left internal mammary artery graft flow.


Subject(s)
Aortic Valve/surgery , Axillary Artery , Cardiac Catheterization/instrumentation , Cardiac Catheters , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Prosthesis Failure , Aged , Aortic Valve/diagnostic imaging , Axillary Artery/diagnostic imaging , Bioprosthesis , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Humans , Male , Prosthesis Design , Radiography , Subclavian Artery/diagnostic imaging , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...