Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 734
Filter
1.
Trauma Case Rep ; 52: 101062, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38957172

ABSTRACT

Decision-making regarding limb amputation represents a significant clinical challenge, especially when the initial evaluation does not coincide with the criteria established in scales used worldwide, as is the case of the MESS scale. This article presents the case of a 24-year-old female patient who was transferred to a university hospital after a road traffic accident with severe and large lesions in the left lower limb. Despite a poor initial prognosis and in-hospital complications, including multiple surgical procedures and foot drop, a favorable recovery was achieved with complete anatomical salvage of the limb at risk. The multidisciplinary approach and intensive rehabilitation were instrumental in achieving a satisfactory functional recovery. This case highlights the importance of considering factors beyond amputation scale scores, as well as the need for comprehensive care to improve outcomes in patients with complex extremity injuries.

2.
Trauma Case Rep ; 53: 101048, 2024 Oct.
Article in English | MEDLINE | ID: mdl-38983368

ABSTRACT

Proximal phalanx fractures of the big toe involving angulation or dislocation of the articular surface require repositioning and fixation. We treated a patient with such a fracture using a novel wire-connected external fixator, the ICHI-FIXATOR® system. A 45-year-old male sustained an injury when slipping down the stairs and impacting his left big toe. Plain radiography and computed tomography revealed a proximal phalangeal fracture of the left big toe with dislocation of the articular surface and comminution. The surgical intervention was performed using 1.1-mm diameter C-wires and an external fixator. The patient regained ambulation and resumed work immediately after surgery. Four weeks postoperatively, all wires were removed on an outpatient basis. Eight months postoperatively, the patient experienced no pain during strenuous activities or exercises. This novel wire-connected external fixator provides reliable and secure fixation, facilitating a prompt return to normal daily activities. This technique may be an effective option for managing toe fractures.

4.
BMC Musculoskelet Disord ; 25(1): 353, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724941

ABSTRACT

BACKGROUND: External fixation is widely used in the treatment of traumatic fractures; however, orthopedic surgeons encounter challenges in deciding the optimal time for fixator removal. The axial load-share ratio (LS) of the fixator is a quantitative index to evaluate the stiffness of callus healing. This paper introduces an innovative method for measuring the LS and assesses the method's feasibility and efficacy. Based on a novel hexapod LS-measurement system, the proposed method is to improve the convenience and precision of measuring LS in vivo, hence facilitating the safe removal of external fixators. METHODS: A novel hexapod system is introduced, including its composition, theoretical model, and method for LS measurement. We conducted a retrospective study on 82 patients with tibial fractures treated by the Taylor Spatial Frame in our hospital from September 2018 to June 2020, of which 35 took LS measurements with our novel method (Group I), and 47 were with the traditional method (Group II). The external fixator was removed when the measurement outcome (LS < 10%) was consistent with the surgeon's diagnosis based on the clinical and radiological assessment (bone union achieved). RESULTS: No significant difference was found in the fracture healing time (mean 25.3 weeks vs. 24.9 weeks, P > 0.05), frame-wearing duration (mean 25.5 weeks vs. 25.8 weeks, P > 0.05), or LS measurement frequency (mean 1.1 times vs. 1.2 times, P > 0.05). The measurement system installation time in Group I was significantly shorter compared to Group II (mean 14.8 min vs. 81.3 min, P < 0.001). The LS value of the first measurement in Group I was lower than that of Group II (mean 5.1% vs. 6.9%, P = 0.011). In Group I, the refracture rate was 0, but in Group II it was 4.3% (2/47, P > 0.05). CONCLUSION: The novel hexapod LS-measurement system and involved method demonstrated enhanced convenience and precision in measuring the LS of the external fixator in vivo. The LS measurement indicates the callus stiffness of fracture healing, and is applicable to evaluate the safety of removing the fixator. Consequently, it is highly recommended for widespread adoption in clinical practice.


Subject(s)
Device Removal , External Fixators , Fracture Fixation , Fracture Healing , Tibial Fractures , Humans , Female , Tibial Fractures/surgery , Male , Retrospective Studies , Adult , Middle Aged , Fracture Fixation/instrumentation , Fracture Fixation/methods , Device Removal/methods , Weight-Bearing , Young Adult , Aged , Feasibility Studies , Equipment Design
5.
BMC Musculoskelet Disord ; 25(1): 389, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38762453

ABSTRACT

BACKGROUND: Several methods have been used for the treatment of pediatric distal femoral fractures, such as elastic stable intramedullary nail (ESIN), external fixator (EF) and plate osteosynthesis, but there has been no consensus about the optimal method. The purpose of this study was to compare the clinical outcome between EF and ESIN techniques used in metaphyseal-diaphyseal junction (MDJ) fractures of the pediatric distal femur. METHODS: We retrospectively analyzed operatively treated MDJ fractures of pediatric distal femur between January 2015 and January 2022. Patient charts were reviewed for demographics, injury and data of radiography. All of the patients were divided into EF and ESIN groups according to the operation techniques. Malalignment was defined as more than 5 degrees of angular deformity in either plane. Clinical outcomes were measured by Flynn scoring system. RESULTS: Thirty-eight patients were included in this study, among which, 23 were treated with EF, and 15 with ESIN. The mean follow-up time was 18 months (12-24 months). At the final follow-up, all of the fractures were healed. Although there were no statistical differences between the two groups in demographic data, length of stay, estimated blood loss (EBL), rate of open reduction, time to fracture healing and Flynn score, the EF was superior to ESIN in operative time, fluoroscopic exposure and time to partial weight-bearing. The EF group had a significantly higher rate of skin irritation, while the ESIN had a significantly higher rate of malalignment. CONCLUSION: EF and ESIN are both effective methods in the treatment of MDJ fractures of the pediatric distal femur. ESIN is associated with lower rates of skin irritation. However, EF technique has the advantages of shorter operative time, reduced fluoroscopic exposure, and shorter time to partial weight-bearing, as well as lower incidence of malalignment. LEVEL OF EVIDENCE: Level III.


Subject(s)
Bone Nails , External Fixators , Femoral Fractures , Fracture Fixation, Intramedullary , Humans , Female , Male , Retrospective Studies , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Child , Fracture Fixation, Intramedullary/instrumentation , Fracture Fixation, Intramedullary/methods , Treatment Outcome , Case-Control Studies , Fracture Healing , Diaphyses/injuries , Diaphyses/surgery , Diaphyses/diagnostic imaging , Child, Preschool , Follow-Up Studies , Adolescent , Femur/surgery , Femur/diagnostic imaging
6.
JSES Rev Rep Tech ; 4(2): 196-203, 2024 May.
Article in English | MEDLINE | ID: mdl-38706679

ABSTRACT

Background: Despite surgical reestablishment of the supporting structures, instability may often persist in traumatic elbow injury. In these cases, a temporary internal or external fixator may be indicated to unload the repaired structures and maintain joint concentricity. Aggregate data are needed to characterize the risk of complication between external fixation (ExFix) and the internal joint stabilizer (IJS) when used for traumatic elbow instability. Our objective was to review the literature to compare the complication profile between external fixation and the IJS. Methods: A database query was performed in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The Population, Intervention, Comparison and Outcome characteristics for eligibility were the following: for patients over 18 years clinical outcomes were compared between an ExFix or the IJS for acute or chronic elbow instability. The Cochran risk of bias in nonrandomized studies of interventions and grades of recommendation, assessment, development, and evaluation framework were compiled for risk of bias and quality assessment. Results: The rate of recurrent instability was 4.1% in the IJS group (N = 171) and 7.0% in the ExFix group (N = 435), with an odds ratio of 1.93 (95% confidence interval 0.88-4.23). The rate of device failure was 4.4% in the IJS group and 4.1% in the ExFix group. Pin-related complications occurred in 14.6% of ExFix cases. Complications in the IJS group were the following: 1 case of inflammatory reaction, 4 cases of post removal surgical site infection, and 5 symptomatic removals. Discussion: The literature demonstrates a distinct difference in complication profile between external fixation and the IJS when used as treatment for traumatic elbow instability. Although not statistically significant, the higher rate of recurrent instability following external fixation may be clinically important. The high rate of pin-related complications with external fixation is notable.

7.
J Orthop Sci ; 2024 May 20.
Article in English | MEDLINE | ID: mdl-38772762

ABSTRACT

BACKGROUND: Webplasty can be conducted for complex syndactyly caused by Apert syndrome (also referred to as Apert hand) by extending the soft tissue in the lateral direction using an external fixator. This study aimed to verify the usefulness of webplasty without skin grafting. METHODS: Webplasty with lateral extension was conducted at a single institution from 2015 to 2023. The patients were four children with Apert hand aged 1-3 years. A custom-made small external fixator was used for all of the soft tissue extension. RESULTS: Webplasty without skin grafting was completed by the time all five patients were 5-6 years of age. CONCLUSION: Webplasty without skin grafting was possible with lateral extension of the soft tissue using a simple external fixator.

8.
Strategies Trauma Limb Reconstr ; 19(1): 45-55, 2024.
Article in English | MEDLINE | ID: mdl-38752194

ABSTRACT

Introduction: External fixation devices are commonly used in orthopaedic surgery to manage a range of pathologies. In this patient population, there is currently no consensus on optimal rehabilitation techniques. There exists a large variation in practice, with a limited understanding of how these affect treatment outcomes. Methods: Following Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines, a systematic review was conducted of Allied and Complementary Medicine Database (AMED), Cumulative Index to Nursing and Allied Health Literature (CINAHL), MEDLINE, PEDro, and COCHRANE databases, grey literature sources and forward and backward searching of included articles. Studies were selected following rigorous screening with predefined inclusion criteria. Data quality was assessed using validated appraisal tools. Articles were synthesised by rehabilitation type and descriptive analysis was subsequently performed. Results: From 1,156 articles identified, 18 were eligible for inclusion. The overall quality was low, with clinical commentaries and case studies being the most common study type. Studies were synthesised by rehabilitation type, the most common themes being gait re-education, strengthening, therapy-assisted, active exercises and weight-bearing exercises. Conclusion: There is a lack of high-quality evidence to support meaningful recommendations and guide rehabilitation practices for this patient cohort. Further research for patients being treated in external fixation, especially related to the potential effects of physical rehabilitation on bone healing, return of strength, mobility and independent function is likely to have transferability within wider orthopaedic populations. Clinical significance: This systematic review is unable to provide clinical recommendations due to the poor quality of the available literature. However, it is hoped this paper will provide a foundation for further research to improve rehabilitation for patients being treated with external fixation. How to cite this article: Pawson JR, Church D, Fletcher J, et al. Rehabilitation Techniques for Adults Undergoing External Fixation Treatment for Lower Limb Reconstruction: A Systematic Review. Strategies Trauma Limb Reconstr 2024;19(1):45-55.

9.
Strategies Trauma Limb Reconstr ; 19(1): 36-39, 2024.
Article in English | MEDLINE | ID: mdl-38752189

ABSTRACT

Aim: This prospective study assessed the clinical and radiological outcomes of open tibia fractures treated with a dynamic external fixator. Materials and methods: Twenty-five patients underwent surgical debridement and stabilisation with a dynamic external fixator between November 2016 and April 2022. Regular follow-up evaluated bone healing progression. Results: Favourable outcomes were demonstrated in 20 patients. However, there were three cases of non-union, two of which subsequently deformed, and two cases of pin site-related infection. There were no fracture site infections. Conclusion: This study demonstrates the use of dynamic external fixation in the treatment of open tibia fractures. The low incidence of complications suggests its effectiveness and potential. How to cite this article: Bezerra BS, Araujo TA, Cardonia GG, et al. The Applicability of Dynamic External Fixator in a Prospective Evaluation of Open Tibial Fracture Treatment. Strategies Trauma Limb Reconstr 2024;19(1):36-39.

10.
Cureus ; 16(3): e56201, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38618459

ABSTRACT

Distal femur fractures are severe all over the world. The goal of the study was to assess the effect of physiotherapy on ROM, strength, and improving quality of life. Due to the anatomy of distal femur fracture, the Ilizarov ring fixator is useful as it helps maintain mobility and stability. Distal femur fractures are most treated surgically compared to non-surgical treatment. The use of external fixators differs according to the patient's condition and the stability of the patient. This study's objective was to evaluate the effectiveness of an evidence-based procedure prepared for the management of distal femur fracture and chronic osteomyelitis femur. In some cases, due to discharging sinus, the patient requires long-term treatment followed by a home physiotherapy rehabilitation program. The objective was to assess the effects of Ilizarov circular external fixators (ICEF) on distal femur fracture.

11.
J Pak Med Assoc ; 74(3): 440-444, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38591274

ABSTRACT

Objective: To determine the combined column tibial plateau fracture treated with a hybrid external fixator in terms of knee functionality, union outcome and complications. METHODS: The quasi-experimental study was conducted at the Department of Orthopaedic Surgery, Mayo Hospital, Lahore, Pakistan, from July 5, 2019, to December 31, 2021, and comprised patients of either gender aged 20-50 years who presented with 2-column or 3-column fractures of proximal tibia classified according to the 3-column classification system after being diagnosed using radiographs and three-dimensional computed tomography scan. Knee function, union and complications, like neural, vascular, infection, delayed union, nonunion, malunion and implant failure, were evaluated. The Knee Society Score was used to assess knee function, and modified Rasmussen score for the union, while complications were assessed clinically on the 2nd, 6th, 12th, 16th, 24th, 36th weeks and one year post-operatively. Data was analysed using SPSS 26. RESULTS: Of the 113 patients, 91(80.53%) were males and 22(19.47%) were females. The overall mean age was 35.56±9.00 years. From the 12th week to the 24th week 45(39.83%) patients had good and 59(52.21%) patients had excellent functional outcomes. Union outcome in the 16th and 24th week was good in 57(50.44%) patients and excellent in 47(41.59%) patients. No neurovascular injury was observed. Superficial pin tract infection was observed in 21(18.6%) cases that healed with wound debridement and antibiotics. No delayed union, malunion and implant failure was observed. CONCLUSIONS: Good to excellent functional and union outcomes with minimum complications were observed with the hybrid external fixator.


Subject(s)
Tibial Fractures , Tibial Plateau Fractures , Male , Female , Humans , Adult , Treatment Outcome , Tibial Fractures/diagnostic imaging , Tibial Fractures/surgery , External Fixators , Fracture Fixation/methods , Fracture Fixation, Internal/methods , Retrospective Studies
12.
BMC Musculoskelet Disord ; 25(1): 284, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38609889

ABSTRACT

BACKGROUND: The purpose of the study was to assess and compare the clinical efficacy of bone transport with either circular or unilateral external fixators over an intramedullary nail in the treatment of tibial bone defects caused by infection. METHODS: Between May 2010 and January 2019, clinical and radiographic data were collected and analyzed for patients with bone defects caused by infection. Thirteen patients underwent bone transport using a unilateral external fixator over an intramedullary nail (Group A), while 12 patients were treated with a circular external fixator over an intramedullary nail (Group B). The bone and functional outcomes of both groups were assessed and compared using the Association for the Study and Application of the Method of the Ilizarov criteria, and postoperative complications were evaluated according to the Paley classification. RESULTS: A total of 25 patients were successfully treated with bone transport using external fixators over an intramedullary nail, with a mean follow-up time of 31.63 ± 5.88 months. There were no significant statistical differences in age, gender, previous surgery per patient, duration of infection, defect size, and follow-up time between Group A and Group B (P > 0.05). However, statistically significant differences were observed in operation time (187.13 ± 21.88 min vs. 255.76 ± 36.42 min, P = 0.002), intraoperative blood loss (39.26 ± 7.33 mL vs. 53.74 ± 10.69 mL, P < 0.001), external fixation time (2.02 ± 0.31 month vs. 2.57 ± 0.38 month, P = 0.045), external fixation index (0.27 ± 0.08 month/cm vs. 0.44 ± 0.09 month/cm, P = 0.042), and bone union time (8.37 ± 2.30 month vs. 9.07 ± 3.12, P = 0.032) between Group A and Group B. The excellent and good rate of bone and functional results were higher in Group A compared to Group B (76.9% vs. 75% and 84.6% vs. 58.3%). Statistically significant differences were observed in functional results (excellent/good/fair/poor, 5/6/2/0 vs. 2/5/4/1, P = 0.013) and complication per patient (0.38 vs. 1.16, P = 0.012) between Group A and Group B. CONCLUSIONS: Bone transport using a combined technique of external fixators over an intramedullary nail proved to be an effective method in treating tibial bone defects caused by infection. In comparison to circular external fixators, bone transport utilizing a unilateral external fixator over an intramedullary nail resulted in less external fixation time, fewer complications, and better functional outcomes.


Subject(s)
External Fixators , Manipulation, Osteopathic , Humans , Retrospective Studies , Fracture Fixation , Internal Fixators
13.
Healthcare (Basel) ; 12(7)2024 Apr 07.
Article in English | MEDLINE | ID: mdl-38610226

ABSTRACT

The aim of this systematic review was to investigate the outcomes of knee arthrodesis (KA) after periprosthetic joint infection (PJI) of the knee. Differences in clinical outcomes and complication rates among the intramedullary nailing (IMN), external fixation (EF), and compression plating (CP) procedures were compared. A total of 23 studies were included. Demographics, microbiological data, types of implants, surgical techniques with complications, reoperations, fusion, and amputation rates were reported. A total of 787 patients were evaluated, of whom 601 (76.4%), 166 (21%), and 19 (2.4%) underwent IMN, EF, and CP, respectively. The most common causative pathogen was coagulase-negative Staphylococcus (CNS). Fusion occurred in 71.9%, 78.8%, and 92.3% of the patients after IMN, EF, and CP, respectively, and no statistically significant difference was found. Reinfection rates were 14.6%, 15.1%, and 10.5% after IMN, EF, and CP, respectively, and no statistically significant difference was found. Conversion to amputation occurred in 4.3%, 5%, and 15.8% of patients after IMN, EF, and CP, respectively; there was a higher rate after CP than after EF. The IMN technique is the most common option used for managing PJI with KA. No differences in terms of fusion, reinfection, or conversion-to-amputation rates were reported between IMN and EF. CP is rarely used, and the high amputation rate represents an important limitation of this technique.

14.
Int Orthop ; 48(6): 1427-1438, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38558191

ABSTRACT

PURPOSE: To present the technique of correction of multiplanar deformities around the knee in children and adolescents using the monolateral external fixator. Also, to evaluate the results of the technique regarding radiological correction, time to union, and possible complications. METHODS: A total of 29 patients (47 limbs) were prospectively included in the study (14 males and 15 females). Their median age was 13 years (range, 7-17). All patients had at least a 2-plane deformity around the knee which was corrected using a monolateral external fixator. The primary outcome measure was deformity correction (correction of mechanical axis deviation (MAD) in both the coronal and sagittal planes with correction of rotational deformities). The secondary outcome measures included bony union, radiographic, and functional results (assessed by using the Association for the Study and Application of the Method of Ilizarov (ASAMI) score). RESULTS: The median pre-operative MAD improved from 6.3 to 0.4 cm post-operatively. According to the ASAMI scoring system, the radiographic scoring was excellent in all cases (100%), and the functional scoring was excellent in 22 cases (89.7%) and good in three cases (10.3%). CONCLUSION: The simple monolateral fixator can be an effective tool for multiplanar correction of complex deformities around the knee without limb length discrepancy.


Subject(s)
External Fixators , Knee Joint , Humans , Adolescent , Female , Child , Male , Knee Joint/surgery , Knee Joint/diagnostic imaging , Knee Joint/abnormalities , Prospective Studies , Radiography/methods , Treatment Outcome , Ilizarov Technique/instrumentation
15.
Sci Rep ; 14(1): 9544, 2024 04 25.
Article in English | MEDLINE | ID: mdl-38664538

ABSTRACT

To compare the biomechanical properties of several anterior pelvic ring external fixators with two new configurations in the treatment of Tile C pelvic fractures, in order to evaluate the effectiveness of the new configurations and provide a reference for their clinical application. A finite element model of a Tile C pelvic ring injury (unilateral longitudinal sacral fracture and ipsilateral pubic fracture) was constructed. The pelvis was fixed with iliac crest external fixator (IC), anterior inferior iliac spine external fixator (AIIS), combination of IC and AIIS, combination of anterior superior iliac spine external fixator (ASIS) and AIIS, and S1 sacroiliac screw in 5 types of models. The stability indices of the anterior and posterior pelvic rings under vertical longitudinal load, left-right compression load and anterior-posterior shear load were quantified and compared. In the simulated bipedal standing position, the results of the vertical displacement of the midpoint on the upper surface of the sacrum are consistent with the displacement of the posterior rotation angle, and the order from largest to smallest is IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. The longitudinal displacement of IC is greater than that of the other models. The displacements of ASIS + AIIS and IC + AIIS are similar and the latter is smaller. In the simulated semi-recumbent position, the vertical displacement and posterior rotation angle displacement of the midpoint on the upper surface of the sacrum are also consistent, ranking from large to small: IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. Under the simulated left-right compression load state, the lateral displacements of the highest point of the lateral sacral fracture end are consistent with the highest point of the lateral pubic fracture end, and the order from large to small is S1 screw, IC, AIIS, ASIS + AIIS and IC + AIIS, among which the displacements of S1 screw and IC are larger, and the displacements of ASIS + AIIS and IC + AIIS are similar and smaller than those of other models. The displacements of IC + AIIS are smaller than those of ASIS + AIIS. Under the simulated anterior-posterior shear load condition, the posterior displacements of the highest point of the lateral sacral fracture end and the highest point of the lateral pubic fracture end are also consistent, ranking from large to small: IC, AIIS, ASIS + AIIS, IC + AIIS and S1 screw. Among them, the displacements of IC and AIIS are larger. The displacements of ASIS + AIIS and IC + AIIS are similar and the latter are smaller. For the unstable pelvic injury represented by Tile C pelvic fracture, the biomechanical various stabilities of the combination of IC and AIIS are superior to those of the external fixators of conventional configurations. The biomechanical stabilities of the combination of ASIS and AIIS are also better than those of the external fixators of conventional configurations, and slightly worse than those of the combination of IC and AIIS. Compared with sacroiliac screw and conventional external fixators, the lateral stabilities of IC + AIIS and ASIS + AIIS are particularly prominent.


Subject(s)
External Fixators , Fractures, Bone , Pelvic Bones , Humans , Biomechanical Phenomena , Pelvic Bones/injuries , Pelvic Bones/surgery , Fractures, Bone/surgery , Fracture Fixation/methods , Fracture Fixation/instrumentation , Finite Element Analysis , Sacrum/injuries , Sacrum/surgery , Bone Screws
16.
Sci Rep ; 14(1): 7111, 2024 03 26.
Article in English | MEDLINE | ID: mdl-38531907

ABSTRACT

This study aims to measure anatomical data of the capitate bone, develop an external fixator for treating late-stage osteonecrosis of lunate through Ilizarov technique, and evaluate its biomechanical performance. We selected eight wrist joint specimens to measure various parameters of the capitate bone, including its length, the distance from the junction of capitate head and body to the proximal end, as well as the width of its proximal head and distal body. Additionally, we measured these same indicators in 107 patients who had undergone wrist X-ray examination. Based on our measurements, we categorized the capitate bone into two groups and designed two types of capitate bone Ilizarov external fixator (CIEF) for it. Then, we compared it with the orthofix external fixator (OEF) through dynamic fatigue biomechanical experiments and pull-out resistance experiments. The results of the measurement revealed two categories of general patterns in the capitate bone. The first type maintains a consistent longitudinal axis between the proximal and distal ends. The second type is characterized by its proximal end being close to the radial side and its distal end being close to the ulnar side. In the dynamic tensile fatigue test, CIEF-A and CIEF-B had smaller maximum displacement values compared to the OEF (P < 0.05). In the anti-pull-out experiment, both CIEF-A and CIEF-B exhibited higher maximum pull-out force than the OEF (P < 0.05). CIFE is a treatment for advanced osteonecrosis of the lunate bone. It is specifically designed to align with the anatomical characteristics of the capitate bone, providing excellent biomechanical properties and a simple clinical procedure. However, additional clinical experiments are needed to confirm its effectiveness in the future.


Subject(s)
Capitate Bone , Lunate Bone , Osteonecrosis , Humans , Osteonecrosis/surgery , Wrist Joint/surgery , Radius
17.
Bioengineering (Basel) ; 11(3)2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38534553

ABSTRACT

BACKGROUND: The lack of resources limits the treatment of craniomaxillofacial fractures (CMF) in low-income countries (LIC). Therefore, Barton bandages and/or interdental wiring are considered in these regions. Fracture reduction is maintained by permanent occlusion for 6 weeks, which often leads to limited compliance and dissatisfying results. The aim of this cadaver-based study is to evaluate the feasibility of the use of an external face fixator (EFF) for the treatment of CMF, its biomechanical values and to define the optimal pin insertion points and angles. MATERIALS AND METHODS: An AO hand fixator was used. CMF of types Le Fort 1-3 with split fractures of the hard palate were treated with EFF on 13 anatomical specimens. Fractures were created using a chisel, and pins were placed in specific anatomical regions. The maximal pull-out force [N] of pins was analysed by a tensile force gauge, and Fmax of the mandibular pins was evaluated. Computer tomography scans were performed on the healthy, fractured and EFF-treated skulls. RESULTS: The pull-out forces for the single pins were mandibular pins (n = 15, median 488.0 N), supraorbital pins (n = 15, median 455.0 N), zygomatic pins (n = 14, median 269.1 N), medial hard palate pins (n = 12, median 208.4 N) and lateral hard palate pins (n = 8, median 49.6 N). CONCLUSIONS: The results indicate that the operation technique is feasible, and the stability of the EFF is sufficient for maintaining the reduction. The required pins can safely be inserted into the described areas with good reduction results. Using EFF offers a feasible alternative to the non-surgical treatment of CMF in LIC.

18.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 284-289, 2024 Mar 15.
Article in Chinese | MEDLINE | ID: mdl-38500420

ABSTRACT

Objective: To analyze the effectiveness comparison of external fixator combined with Kirschner wire fixation and Kirschner wire fixation in the treatment of cubitus varus deformity in children. Methods: A retrospective case-control study was conducted to collect 36 children of postoperative supracondylar humerus fracture complicating cubitus varus deformity between January 2018 and July 2022. Among them, 17 cases were treated with distal humeral wedge osteotomy external fixation combined with Kirschner wire fixation (observation group), and 19 cases were treated with distal humeral wedge osteotomy and Kirschner wire fixation (control group). The baseline data including age, gender, deformity side, time from fracture to operation, carrying angle of the healthy side and preoperative carrying angle of the affected side, elbow flexion and extension range of motion, and lateral condylar prominence index (LCPI) showed no significant difference between the two groups ( P>0.05). The operation time, hospitalization cost, healing time of osteotomy, postoperative complications, and the carrying angle, LCPI, and elbow flexion and extention range of motion were recorded and compared between the two groups. The elbow function was assessed by Oppenheim score at 3 months after operation and at last follow-up. Results: The children in both groups were followed up 13-48 months, with an average of 26.7 months. There was 1 case of needle tract infection in the observation group and 2 cases in the control group, and no nerve injury occurred, the difference in the incidence of complication (5.88% vs 10.53%) between the two groups was not significant ( χ 2=0.502, P=0.593). There was no significant difference in the operation time and fracture healing time between the two groups ( P>0.05); the hospitalization cost of the observation group was significantly higher than that of the control group ( P<0.05). The Oppenheim score of the observation group was significantly better than that of the control group at 3 months after operation ( P<0.05), but there was no significant difference in the Oppenheim score between the two groups at last follow-up ( P>0.05). At last follow-up, the carrying angle of affected side significantly improved in both groups when compared with preoperative ones ( P<0.05); the differences of the pre- and post-operative carrying angle of affected side and elbow flexion and extension range of motion showed no significant differences between the two groups ( P>0.05), but the difference in pre- and post-operative LCPI of the observation group was significantly better than that of the control group ( P<0.05). Conclusion: External fixator combined with Kirschner wire fixation and Kirschner wire fixation both can achieve satisfactory correction of cubitus varus deformity in children, and the former can achieve better short-term functional recovery of elbow joint and reduce the incidence of humeral lateral condyle protrusion.


Subject(s)
Elbow Joint , Hallux Varus , Humeral Fractures , Limb Deformities, Congenital , Child , Humans , Bone Wires , Elbow , Retrospective Studies , Case-Control Studies , Humeral Fractures/surgery , Elbow Joint/surgery , External Fixators , Range of Motion, Articular , Hallux Varus/complications , Treatment Outcome
19.
J Mech Behav Biomed Mater ; 153: 106488, 2024 May.
Article in English | MEDLINE | ID: mdl-38437754

ABSTRACT

INTRODUCTION: This systematic review aims to identify previously used techniques in biomechanics to assess pelvic instability following pelvic injury, focusing on external fixation constructs. METHODS: A systematic literature search was conducted to include biomechanical studies and to exclude clinical trials. RESULTS: Of an initial 4666 studies found, 38 met the inclusion criteria. 84% of the included studies were retrieved from PubMed, Scopus, and Web of Science. The studies analysed 106 postmortem specimens, 154 synthetic bones, and 103 computational models. Most specimens were male (97% synthetic, 70% postmortem specimens). Both the type of injury and the classification system employed varied across studies. About 82% of the injuries assessed were of type C. Two different fixators were tested for FFPII and type A injury, five for type B injury, and fifteen for type C injury. Large variability was observed for external fixation constructs concerning device type and configuration, pin size, and geometry. Biomechanical studies deployed various methods to assess injury displacement, deformation, stiffness, and motion. Thereby, loading protocols differed and inconsistent definitions of failure were determined. Measurement techniques applied in biomechanical test setups included strain gauges, force transducers, and motion tracking techniques. DISCUSSION AND CONCLUSION: An ideal fixation method should be safe, stable, non-obstructive, and have low complication rates. Although biomechanical testing should ensure that the load applied during testing is representative of a physiological load, a high degree of variability was found in the current literature in both the loading and measurement equipment. The lack of a standardised test design for fixation constructs in pelvic injuries across the studies challenges comparisons between them. When interpreting the results of biomechanical studies, it seems crucial to consider the limitations in cross-study comparability, with implications on their applicability to the clinical setting.


Subject(s)
Fractures, Bone , Pelvic Bones , Humans , Biomechanical Phenomena , External Fixators , Fracture Fixation/methods , Pelvic Bones/surgery
20.
J West Afr Coll Surg ; 14(1): 102-108, 2024.
Article in English | MEDLINE | ID: mdl-38486644

ABSTRACT

Background: Ankle equinus deformity is a common complication of prolonged external fixator use in tibia fractures with an incidence of 15%-16%. It affects gait and may lead to foot, leg, and back problems. Treatment of equinus deformity increases the cost of treatment of open tibia fractures and increases the time spent off work. Several preventive modalities have been suggested in literature with variable success, but no standard protocol exists. Objectives: The aim of this study was to determine the most appropriate method of preventing equinus deformity of the ankle joint during the management of open tibia fractures with unilateral uniplanar external fixators by comparing plaster of paris (POP) backslab application with passive ankle physiotherapy using strips of car tyre inner tubing. Materials and Methods: The study was a prospective randomised study involving patients with open tibia fractures who were managed with external fixators at the Korle Bu Teaching Hospital between April 2020 and February 2021. Patients were randomised into two groups; one group had below knee POP backslab and the other group did passive ankle physiotherapy using a strip of car tyre inner tubing. The passive ankle range of motion was measured at the beginning and after 6 weeks using a goniometer. Results: Fifty-six participants were recruited with 29 in the POP backslab group and 27 in the ankle physiotherapy group. The median age was 35.0 years. Male-to-female ratio was 4.6:1. Motor vehicle crash contributed to over 90% with 42.9% being motorbike riders. Initial and final mean ankle measurements for the POP backslab group were 6.79° and 10.14° for dorsiflexion and 29.93° and 34.52° for plantarflexion, respectively. The ankle physiotherapy group had initial and final dorsiflexion of 7.19° and 12.85° and plantarflexion of 30.44° and 34.52°, respectively. The ankle physiotherapy group had a better range of motion (47.37°) than the POP group (40.66°) with a P value of 0.008. One participant (3.7%) from the ankle physiotherapy group had equinus deformity compared with seven (24%) from the POP backslab group, a difference which gives a P value of 0.029. Conclusions: Passive ankle physiotherapy with car tyre inner tube is a better and cheaper modality of preventing ankle equinus deformity and maintaining ankle range of motion.

SELECTION OF CITATIONS
SEARCH DETAIL
...