Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.256
Filter
1.
Doc Ophthalmol ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38955959

ABSTRACT

PURPOSE: The electroretinogram (ERG) is the summed response from all levels of the retinal processing of light, and exhibits several profound nonlinearities in the underlying processing pathways. Accurate computational models of the ERG are important, both for understanding the multifold processes of light transduction to ecologically useful signals by the retina, and for their diagnostic capabilities for the identification and characterization of retinal disease mechanisms. There are, however, very few computational models of the ERG waveform, and none that account for the full extent of its features over time. METHODS: This study takes the neuroanalytic approach to modeling the ERG waveform, defined as a computational model based on the main features of the transmitter kinetics of the retinal neurons. RESULTS: The present neuroanalytic model of the human rod ERG is elaborated from the same general principles as that of Hood and Birch (Vis Neurosci 8(2):107-126, 1992), but incorporates the more recent understanding of the early nonlinear stages of ERG generation by Robson and Frishman (Prog Retinal Eye Res 39:1-22, 2014). As a result, it provides a substantially better match than previous models of rod responses in six different waveform features of the ERG flash intensity series on which the Hood and Birch model was based. CONCLUSION: The neuroanalytic approach extends previous models of the component waves of the ERG, and can be structured to provide an accurate characterization of the full timecourse of the ERG waveform. The approach thus holds promise for advancing the theoretical understanding of the retinal kinetics of the light response.

2.
Phys Med Biol ; 2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38959905

ABSTRACT

Oxygen depletion is generally believed to play an important role in the FLASH effect - a differential reduction of the radiosensitivity of healthy tissues, relative to that of the tumour under ultra-high dose-rate (UHDR) irradiation conditions. In proton therapy (PT) with pencil-beam scanning (PBS), the deposition of dose, and, hence, the degree of (radiolytic) oxygen depletion varies both spatially and temporally. Therefore, the resulting oxygen concentration and the healthy-tissue sparing effect through radiation-induced hypoxia varies both spatially and temporally as well. We propose and numerically solve a physical oxygen diffusion model to study these effects and their dependence on tissue parameters and the scan pattern in pencil-beam delivery. Since current clinical FLASH proton therapy (FLASH-PT) is based on 250 MeV shoot-through (transmission) beams, for which dose and dose rate hardly vary with depth compared to the variation transverse to the beam axis, we focus on the two-dimensional case. We numerically integrate the model to obtain the oxygen concentration in each voxel as a function of time and extract voxel-based and spatially and temporarily integrated metrics for oxygen (FLASH) enhanced dose. Furthermore, we evaluate the impact on oxygen enhancement of standard pencil-beam delivery patterns and patterns that were optimised on dose-rate. Our model can contribute to the identification of tissue properties and pencil-beam delivery parameters that are critical for FLASH-PT and it may be used for the optimisation of FLASH-PT treatment plans and their delivery. Our main findings are that: (i) the diffusive properties of oxygen are critical for the steady state concentration and therefore the FLASH effect, even more so in two dimensions when compared to one dimension. (ii) The FLASH effect through oxygen depletion depends primarily on dose and less on other parameters. (iii) At a fixed fraction dose there is a slight dependence on dose rate. (iv) Scan patterns optimised on dose rate slightly increase the oxygen induced FLASH effect.

3.
J Appl Clin Med Phys ; : e14451, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38952057

ABSTRACT

PURPOSE: This study investigated the potential of a commercially available plastic scintillator, the Exradin W2, as a real-time dosimeter for ultra-high-dose-rate (UHDR) electron beams. This work aimed to characterize this system's performance under UHDR conditions and addressed limitations inherent to other conventional dosimetry systems. METHODS AND MATERIALS: We assessed the W2's performance as a UHDR electron dosimeter using a 16 MeV UHDR electron beam from the FLASH research extension (FLEX) system. Additionally, the vendor provided a beta firmware upgrade to better handle the processing of the high signal generated in the UHDR environment. We evaluated the W2 regarding dose-per-pulse, pulse repetition rate, charge versus distance, and pulse linearity. Absorbed dose measurements were compared against those from a plane-parallel ionization chamber, optically stimulated luminescent dosimeters and radiochromic film. RESULTS: We observed that the 1 × 1 mm W2 scintillator with the MAX SD was more suitable for UHDR dosimetry compared to the 1 × 3 mm W2 scintillator, capable of matching film measurements within 2% accuracy for dose-per-pulse up to 3.6 Gy/pulse. The W2 accurately ascertained the inverse square relationship regarding charge versus virtual source distance with R2 of ∼1.00 for all channels. Pulse linearity was accurately measured with the W2, demonstrating a proportional response to the delivered pulse number. There was no discernible impact on the measured charge of the W2 when switching between the available repetition rates of the FLEX system (18-180 pulses/s), solidifying consistent beam output across pulse frequencies. CONCLUSIONS: This study tested a commercial plastic scintillator detector in a UHDR electron beam, paving the way for its potential use as a real-time, patient-specific dosimetry tool for future FLASH radiotherapy treatments. Further research is warranted to test and improve the signal processing of the W2 dosimetry system to accurately measure in UHDR environments using exceedingly high dose-per-pulse and pulse numbers.

4.
EMBO J ; 2024 Jun 21.
Article in English | MEDLINE | ID: mdl-38907032

ABSTRACT

Dynamin 1 mediates fission of endocytic synaptic vesicles in the brain and has two major splice variants, Dyn1xA and Dyn1xB, which are nearly identical apart from the extended C-terminal region of Dyn1xA. Despite a similar set of binding partners, only Dyn1xA is enriched at endocytic zones and accelerates vesicle fission during ultrafast endocytosis. Here, we report that Dyn1xA achieves this localization by preferentially binding to Endophilin A1 through a newly defined binding site within its long C-terminal tail extension. Endophilin A1 binds this site at higher affinity than the previously reported site, and the affinity is determined by amino acids within the Dyn1xA tail but outside the binding site. This interaction is regulated by the phosphorylation state of two serine residues specific to the Dyn1xA variant. Dyn1xA and Endophilin A1 colocalize in patches near the active zone, and mutations disrupting Endophilin A binding to the long tail cause Dyn1xA mislocalization and stalled endocytic pits on the plasma membrane during ultrafast endocytosis. Together, these data suggest that the specificity for ultrafast endocytosis is defined by the phosphorylation-regulated interaction of Endophilin A1 with the C-terminal extension of Dyn1xA.

5.
Cancers (Basel) ; 16(12)2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38927940

ABSTRACT

During the cell life cycle, extracellular vesicles (EVs) transport different cargos, including organelles, proteins, RNAs, DNAs, metabolites, etc., that influence cell proliferation and apoptosis in recipient cells. EVs from metastatic cancer cells remodel the extracellular matrix and cells of the tumor microenvironment (TME), promoting tumor invasion and metastatic niche preparation. Although the process is not fully understood, evidence suggests that EVs facilitate genetic material transfer between cells. In the context of NSCLC, EVs can mediate intercellular mitochondrial (Mt) transfer, delivering mitochondria organelle (MtO), mitochondrial DNA (mtDNA), and/or mtRNA/proteinaceous cargo signatures (MtS) through different mechanisms. On the other hand, certain populations of cancer cells can hijack the MtO from TME cells mainly by using tunneling nanotubes (TNTs). This transfer aids in restoring mitochondrial function, benefiting benign cells with impaired metabolism and enabling restoration of their metabolic activity. However, the impact of transferring mitochondria versus transplanting intact mitochondrial organelles in cancer remains uncertain and the subject of debate. Some studies suggest that EV-mediated mitochondria delivery to cancer cells can impact how cancer responds to radiation. It might make the cancer more resistant or more sensitive to radiation. In our review, we aimed to point out the current controversy surrounding experimental data and to highlight new paradigm-shifting modalities in radiation therapy that could potentially overcome cancer resistance mechanisms in NSCLC.

6.
Environ Monit Assess ; 196(7): 655, 2024 Jun 24.
Article in English | MEDLINE | ID: mdl-38913150

ABSTRACT

Changes to the physicochemical parameters of water in alpine/mountain streams can provide evidence of ongoing natural and anthropogenic processes in their catchment. In this study, we analysed a mountain stream (Javorinka) on the north-eastern side of the Tatra Mountains (Western Carpathians), which is minimally influenced by human activity. The stream was monitored weekly for 5 years (2017-2021) and evaluated for its seasonal variations in physicochemical parameters. These seasonal variations were influenced by the large summer flash flood in July 2018. We hypothesise that floods are essential for the oligotrophic profile of alpine/mountain streams. To support this idea, our main objective was to compare the seasonal trends of the main physicochemical parameters in the stream before and after floods or periods of high flow. We found evidence to support our hypothesis. For example, there was a significant decrease in the chemical consumption of oxygen and ammonia, and, conversely, an increase in the ratio of saturated oxygen and nitrate concentrations. Stream bed erosion also resulted in increased phosphates (over the next 2 years) and high enrichment of the water by dissolved solids in the spring. Interestingly outside of the main objectives, we observed a significant decrease in sulphates, especially in the summer and autumn of 2020 and 2021, which may be related to suppressed emissions due to the restriction of the COVID-19 lockdown. The observed trends and their changes therefore support the idea that alpine/mountain streams are excellent indicators of ongoing environmental processes, and that occasional summer flash floods support the oligotrophic profile of the stream system.


Subject(s)
Environmental Monitoring , Floods , Rivers , Seasons , Rivers/chemistry , COVID-19
7.
Phys Med Biol ; 69(14)2024 Jul 03.
Article in English | MEDLINE | ID: mdl-38876112

ABSTRACT

Objective. To fabricate and validate a novel focused collimator designed to spare normal tissue in a murine hemithoracic irradiation model using 250 MeV protons delivered at ultra-high dose rates (UHDRs) for preclinical FLASH radiation therapy (FLASH-RT) studies.Approach. A brass collimator was developed to shape 250 MeV UHDR protons from our Varian ProBeam. Six 13 mm apertures, of equivalent size to kV x-ray fields historically used to perform hemithorax irradiations, were precisely machined to match beam divergence, allowing concurrent hemithoracic irradiation of six mice while sparing the contralateral lung and abdominal organs. The collimated field profiles were characterized by film dosimetry, and a radiation survey of neutron activation was performed to ensure the safety of staff positioning animals.Main results. The brass collimator produced 1.2 mm penumbrae radiation fields comparable to kV x-rays used in preclinical studies. The penumbrae in the six apertures are similar, with full-width half-maxima of 13.3 mm and 13.5 mm for the central and peripheral apertures, respectively. The collimator delivered a similar dose at an average rate of 52 Gy s-1for all apertures. While neutron activation produces a high (0.2 mSv h-1) initial ambient equivalent dose rate, a parallel work-flow in which imaging and setup are performed without the collimator ensures safety to staff.Significance. Scanned protons have the greatest potential for future translation of FLASH-RT in clinical treatments due to their ability to treat deep-seated tumors with high conformality. However, the Gaussian distribution of dose in proton spots produces wider lateral penumbrae compared to other modalities. This presents a challenge in small animal pre-clinical studies, where millimeter-scale penumbrae are required to precisely target the intended volume. Offering high-throughput irradiation of mice with sharp penumbrae, our novel collimator-based platform serves as an important benchmark for enabling large-scale, cost-effective radiobiological studies of the FLASH effect in murine models.


Subject(s)
Proton Therapy , Animals , Mice , Proton Therapy/instrumentation , Proton Therapy/methods , Organs at Risk/radiation effects , Radiotherapy Dosage
8.
Article in English | MEDLINE | ID: mdl-38885322

ABSTRACT

Objective: We analyzed the effect of implementing a flash glucose monitoring (FGM) technology in a public health care system with universal coverage on the rate of severe hypoglycemia requiring urgent care in adults with type 1 diabetes mellitus (T1DM). Methods: Using a comprehensive regional dataset, we extracted emergency care codes with hypoglycemia in individuals with T1DM who initiated the use of FGM in Andalucia, Spain, from January 1, 2020, to December 31, 2021. Severe hypoglycemia was defined as a confirmed blood glucose <70 mg/dL, which required the urgent dispatch of an emergency medical service (EMS) for onsite management. We compared hypoglycemic events reported in the 12 months before and after the initiation of FGM to determine the population incidence rates. Results: A total of 13,616 participants with a mean age of 43.7 ± 13.5 years were included. The follow-up periods were 23.4 and 24.8 months before and after FGM. There were 969 and 737 cases of hypoglycemia before and after the initiation of FGM. The baseline incidence rate was 358.58 episodes per 10,000 person-years, which decreased to 260.9 at the end of the follow-up (rate-ratio 0.72 [0.66; 0.80]). The reduction in hypoglycemia was significant in individuals aged ≥60 years (rate-ratio 0.40 [0.28; 0.55]) and males (0.64 [0.56; 0.72]). In addition, there was a reduction in the overall median HbA1c of -0.35% (95% CI [-0.38; -0.33], P < 0.001). Conclusion: The implementation of FGM systems in a public health care system as a provision for adults with T1DM was associated with significant reductions in the rate of severe hypoglycemic events that required urgent EMS care.

9.
Article in English | MEDLINE | ID: mdl-38885325

ABSTRACT

Objective: Glycemic management in people with type 2 diabetes mellitus (T2DM) on insulin-secretagogue regimens without insulin is of importance, as this group still represents a significant proportion of patients. Risks for acute diabetes events (ADEs), including diabetic ketoacidosis (DKA) or hypoglycemia, using insulin-secretagogue drugs are well established. Few studies have suggested that continuous glucose monitoring (CGM) could be useful for monitoring glucose dynamics associated with the use of such therapies. To document this point an exploratory analysis was conducted in a group of individuals with noninsulin treated T2DM in France who are managed with oral insulin-secretagogues and initiating the FreeStyle Libre® system (FSL). Methods: A retrospective study of the French national SNDS reimbursement claims database (≈66 million French people) was conducted to identify people with T2DM on oral insulin-secretagogues and receiving a first reimbursement of FSL between August 1, 2017 and December 31, 2018. The analysis included data for the 12 months before and up to 24 months after FSL initiation. Hospitalizations for diabetes-related acute events were identified using ICD-10 codes as main or related diagnosis, for: hypoglycemic events; DKA events; comas; and hyperglycemia-related admissions. Results: A total of 1272 people with T2DM on insulin-secretagogues without insulin initiated FSL during the selection period. Of these, 7.15% had at least one hospitalization for any ADE in the year before FSL initiation, compared with 2.52% at 12 months and 2.83% at 24 months following FSL initiation. Reductions in ADEs were driven by -73% fewer admissions for ADEs related to diabetic ketoacidosis (DKA) or other hyperglycemia-related events. These patterns of reduced ADEs persisted after 2 years. Conclusions: This study suggests the value of the FSL system in reducing ADEs in some people with T2DM in France being treated with insulin-secretagogues without insulin. Characteristics of these patients remain to be documented.

10.
Med Phys ; 2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38873848

ABSTRACT

BACKGROUND: Although the FLASH radiotherapy (FLASH) can improve the sparing of organs-at-risk (OAR) via the FLASH effect, it is generally a tradeoff between the physical dose coverage and the biological FLASH coverage, for which the concept of FLASH effective dose (FED) is needed to quantify the net improvement of FLASH, compared to the conventional radiotherapy (CONV). PURPOSE: This work will develop the first-of-its-kind treatment planning method called simultaneous dose and dose rate optimization via dose modifying factor modeling (SDDRO-DMF) for proton FLASH that directly optimizes FED. METHODS: SDDRO-DMF models and optimizes FED using FLASH dose modifying factor (DMF) models, which can be classified into two categories: (1) the phenomenological model of the FLASH effect, such as the FLASH effectiveness model (FEM); (2) the mechanistic model of the FLASH radiobiology, such as the radiolytic oxygen depletion (ROD) model. The general framework of SDDRO-DMF will be developed, with specific DMF models using FEM and ROD, as a demonstration of general applicability of SDDRO-DMF for proton FLASH via transmission beams (TB) or Bragg peaks (BP) with single-field or multi-field irradiation. The FLASH dose rate is modeled as pencil beam scanning dose rate. The solution algorithm for solving the inverse optimization problem of SDDRO-DMF is based on iterative convex relaxation method. RESULTS: SDDRO-DMF is validated in comparison with IMPT and a state-of-the-art method called SDDRO, with demonstrated efficacy and improvement for reducing the high dose and the high-dose volume for OAR in terms of FED. For example, in a SBRT lung case of the dose-limiting factor that the max dose of brachial plexus should be no more than 26 Gy, only SDDRO-DMF met this max dose constraint; moreover, SDDRO-DMF completely eliminated the high-dose (V70%) volume to zero for CTV10mm (a high-dose region as a 10 mm ring expansion of CTV). CONCLUSION: We have proposed a new proton FLASH optimization method called SDDRO-DMF that directly optimizes FED using phenomenological or mechanistic models of DMF, and have demonstrated the efficacy of SDDO-DMF in reducing the high-dose volume or/and the high-dose value for OAR, compared to IMPT and a state-of-the-art method SDDRO.

11.
Diabetol Metab Syndr ; 16(1): 128, 2024 Jun 12.
Article in English | MEDLINE | ID: mdl-38867297

ABSTRACT

BACKGROUND: Continuous glucose monitoring can improve glycemic control for hospitalized patients with diabetes, according to current evidence. However, there is a lack of consensus-established recommendations for the management of hospitalized patients with diabetes using flash continuous glucose monitoring system (fCGM) in Latin America. Therefore, this expert consensus exercise aimed to establish guidelines on the implementation of fCGM in the management of hospitalized patients with diabetes in Latin America. METHODS: The modified Delphi method was applied on a panel of nine specialists, establishing consensus at 80%. A twenty-two-question instrument was developed to establish recommendations on the use of fCGM in hospitalized patients living with diabetes. RESULTS: Based on consensus, experts recommend the use of fCGM in hospitalized patients with diabetes starting at admission or whenever hyperglycemia (> 180 mg/dl) is confirmed and continue monitoring throughout the entire hospital stay. The recommended frequency of fCGM scans varies depending on the patient's age and diabetes type: ten scans per day for pediatric patients with type 1 and 2 diabetes, adult patients with type 1 diabetes and pregnant patients, and seven scans for adult patients with type 2 diabetes. Different hospital services can benefit from fCGM, including the emergency room, internal medicine departments, intensive care units, surgery rooms, and surgery wards. CONCLUSIONS: The use of fCGM is recommended for patients with diabetes starting at the time of admission in hospitals in Latin America, whenever the necessary resources (devices, education, personnel) are available.

12.
Front Endocrinol (Lausanne) ; 15: 1374496, 2024.
Article in English | MEDLINE | ID: mdl-38836229

ABSTRACT

Aims: The present study aimed to investigate the accuracy of the Glunovo® real-time continuous glucose monitoring system (rtCGMS). Methods: We conducted a 14-day interstitial glucose level monitoring using Glunovo® rtCGMS on thirty hospitalized patients with type 2 diabetes. The flash glucose monitoring (FGM) was used as a self-control. Consistency tests, error grid analysis, and calculation of the mean absolute relative difference (MARD) were performed using R software to assess the accuracy of Glunovo® rtCGMS. Results: Glunovo® exhibited an overall MARD value of 8.89% during hospitalization, compared to 10.42% for FGM. The overall percentages of glucose values within ±10%/10, ± 15%/15, ± 20%/20, ± 30%/30, and ±40%/40 of the venous blood glucose reference value were 63.34%, 81.31%, 90.50%, 97.29%, and 99.36% for Glunovo®, respectively, compared with 61.58%, 79.63%, 88.31%, 96.22% and 99.23% for FGM. The Clarke Error Grid Analysis showed that 99.61% of Glunovo® glucose pairs and 100.00% of FGM glucose pairs within zones A and B. Conclusion: Our study confirms the superior accuracy of Glunovo® in monitoring blood glucose levels among hospitalized patients with type 2 diabetes.


Subject(s)
Blood Glucose Self-Monitoring , Blood Glucose , Diabetes Mellitus, Type 2 , Hospitalization , Humans , Diabetes Mellitus, Type 2/blood , Female , Blood Glucose Self-Monitoring/methods , Blood Glucose Self-Monitoring/instrumentation , Male , Middle Aged , Blood Glucose/analysis , Prospective Studies , Aged , Adult , Continuous Glucose Monitoring
13.
Neuroradiology ; 2024 Jun 17.
Article in English | MEDLINE | ID: mdl-38880824

ABSTRACT

BACKGROUND AND PURPOSE: Quantitative T1 mapping can be an essential tool for assessing tissue injury in multiple sclerosis (MS). We introduce T1-REQUIRE, a method that converts a single high-resolution anatomical 3D T1-weighted Turbo Field Echo (3DT1TFE) scan into a parametric T1 map that could be used for quantitative assessment of tissue damage. We present the accuracy and feasibility of this method in MS. METHODS: 14 subjects with relapsing-remitting MS and 10 healthy subjects were examined. T1 maps were generated from 3DT1TFE images using T1-REQUIRE, which estimates T1 values using MR signal equations and internal tissue reference T1 values. Estimated T1 of lesions, white, and gray matter regions were compared with reference Inversion-Recovery Fast Field Echo T1 values and analyzed via correlation and Bland-Altman (BA) statistics. RESULTS: 159 T1-weighted (T1W) hypointense MS lesions and 288 gray matter regions were examined. T1 values for MS lesions showed a Pearson's correlation of r = 0.81 (p < 0.000), R2 = 0.65, and Bias = 4.18%. BA statistics showed a mean difference of -53.95 ms and limits of agreement (LOA) of -344.20 and 236.30 ms. Non-lesional normal-appearing white matter had a correlation coefficient of r = 0.82 (p < 0.000), R2 = 0.67, Bias = 8.78%, mean difference of 73.87 ms, and LOA of -55.67 and 203.41 ms. CONCLUSIONS: We demonstrate the feasibility of retroactively derived high-resolution T1 maps from routinely acquired anatomical images, which could be used to quantify tissue pathology in MS. The results of this study will set the stage for testing this method in larger clinical studies for examining MS disease activity and progression.

14.
PeerJ ; 12: e17516, 2024.
Article in English | MEDLINE | ID: mdl-38881863

ABSTRACT

Bioluminescence is light chemically produced by an organism. It is widespread across all major marine phyla and has evolved multiple times, resulting in a high diversity of spectral properties and first flash kinetic parameters (FFKP). The bioluminescence of a system is often a good proxy for planktonic biomass. The species-specific parameters of bioluminescent displays can be measured to identify species in situ and describe planktonic biodiversity. Most bioluminescent organisms will flash when mechanically stimulated i.e., when subjected to supra-threshold levels of shear stress. Here we compare first flash kinetic parameters such as flash duration, peak intensity, rise time, decay time, first-flash mechanically stimulated light and e-folding time obtained with the commercially available Underwater Bioluminescence Assessment Tool (UBAT). We provide descriptions of the first flash kinetic parameters of several species of dinoflagellates Pyrocystis fusiformis, Pyrocystis noctiluca, Pyrodinium bahamense, Lingulodinium polyedra, Alexandrium monilatum and two zooplankton (the ctenophore Mnemiopsis leidyi and the larvacean Oikopleura sp.). FFKPs are then compared and discussed using non-parametric analyses of variance (ANOVAs), hierarchical clustering and a linear discriminant analysis to assess the ability to use bioluminescence signatures for identification. Once the first flash kinetic parameters of a bioluminescent species have been described, it is possible to detect its presence using emissions collected by in situ bathyphotometers. Assessing abundance and diversity of bioluminescent species may therefore be possible.


Subject(s)
Biodiversity , Dinoflagellida , Luminescent Measurements , Zooplankton , Zooplankton/physiology , Animals , Dinoflagellida/classification , Dinoflagellida/physiology , Luminescent Measurements/methods , Species Specificity
15.
J Clin Med ; 13(11)2024 May 25.
Article in English | MEDLINE | ID: mdl-38892820

ABSTRACT

Heart failure (HF) is a complex medical condition characterized by both electrical and mechanical dyssynchrony. Both dyssynchrony mechanisms are intricately linked together, but the current guidelines for cardiac resynchronization therapy (CRT) rely only on the electrical dyssynchrony criteria, such as the QRS complex duration. This possible inconsistency may result in undertreating eligible individuals who could benefit from CRT due to their mechanical dyssynchrony, even if they fail to fulfill the electrical criteria. The main objective of this literature review is to provide a comprehensive analysis of the practical value of echocardiography for the assessment of left ventricular (LV) dyssynchrony using parameters such as septal flash and apical rocking, which have proven their relevance in patient selection for CRT. The secondary objectives aim to offer an overview of the relationship between septal flash and apical rocking, to emphasize the primary drawbacks and benefits of using echocardiography for evaluation of septal flash and apical rocking, and to offer insights into potential clinical applications and future research directions in this area. Conclusion: there is an opportunity to render resynchronization therapy more effective for every individual; septal flash and apical rocking could be a very useful and straightforward echocardiography resource.

16.
Diagnostics (Basel) ; 14(11)2024 Jun 03.
Article in English | MEDLINE | ID: mdl-38893703

ABSTRACT

INTRODUCTION: The scapholunate interosseous ligament is pivotal for wrist stability, and its impairment can result in instability and joint degeneration. This study explores the application of real-time MRI for dynamic assessment of the scapholunate joint during wrist motion with the objective of determining its diagnostic value in efficacy in contrast to static imaging modalities. MATERIALS AND METHODS: Ten healthy participants underwent real-time MRI scans during wrist ab/adduction and fist-clenching maneuvers. Measurements were obtained at proximal, medial, and distal landmarks on both dynamic and static images with statistical analyses conducted to evaluate the reliability of measurements at each landmark and the concordance between dynamic measurements and established static images. Additionally, inter- and intraobserver variabilities were evaluated. RESULTS: Measurements of the medial landmarks demonstrated the closest agreement with static images and exhibited the least scatter. Distal landmark measurements showed a similar level of agreement but with increased scatter. Proximal landmark measurements displayed substantial deviation, which was accompanied by an even greater degree of scatter. Although no significant differences were observed between the ab/adduction and fist-clenching maneuvers, both inter- and intraobserver variabilities were significant across all measurements. CONCLUSIONS: This study highlights the potential of real-time MRI in the dynamic assessment of the scapholunate joint particularly at the medial landmark. Despite promising results, challenges such as measurement variability need to be addressed. Standardization and integration with advanced image processing methods could significantly enhance the accuracy and reliability of real-time MRI, paving the way for its clinical implementation in dynamic wrist imaging studies.

17.
Foods ; 13(11)2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38890961

ABSTRACT

The aim of the present research was to determine if the developed ovo-vegetarian sausage (SO), which was made with 15% chickpea flour, 51% albumin and 34% soy protein concentrate, exhibited improved physicochemical and sensory characteristics compared to vegetarian sausages available on the local market (classic vegan sausage, SC; vegan fine herb sausage, SH; and quinoa sausage, SQ). According to the physicochemical results, the developed sample, SO, presented significant differences (p < 0.05) compared to the others, including higher protein content, lower pH and a higher a* value. Three types of sensory analyses were conducted-flash profile, overall liking and purchase intention (to determine consumers' willingness to purchase the product)-with the first involving 15 consumers and the second and third involving 60 participants each. Descriptors for each sample were determined using the vocabulary provided by consumers in the flash profile analysis. Descriptors for SO included 'elastic', 'smell of cooked corn', 'characteristic flavor', 'pasty', 'soft' and 'pastel color', contributing to its greater overall liking and purchase intention compared to the others. Through the hierarchical multiple factor analysis, a positive correlation was observed between the texture and sensory descriptors of the flash profile. Conversely, a correlation was found between the physicochemical characteristics (pH, aw, color) and overall liking and purchase intention.

18.
Front Neurosci ; 18: 1339479, 2024.
Article in English | MEDLINE | ID: mdl-38855441

ABSTRACT

Introduction: Aesthetic emotions are a class of emotions aroused by evaluating aesthetically appealing objects or events. While evolutionary aesthetics suggests the adaptive roles of these emotions, empirical assessments are lacking. Previous neuroscientific studies have demonstrated that visual stimuli carrying evolutionarily important information induce neural responses even when presented non-consciously. To examine the evolutionary importance of aesthetic emotions, we conducted a neuroscientific study using magnetoencephalography (MEG) to measure induced neural responses to non-consciously presented portrait paintings categorised as biological and non-biological and examined associations between the induced responses and aesthetic ratings. Methods: MEG and pre-rating data were collected from 23 participants. The pre-rating included visual analogue scales for object saliency, facial saliency, liking, and beauty scores, in addition to 'biologi-ness,' which was used for subcategorising stimuli into biological and non-biological. The stimuli were presented non-consciously using a continuous flash suppression paradigm or consciously using binocular presentation without flashing masks, while dichotomic behavioural responses were obtained (beauty or non-beauty). Time-frequency decomposed MEG data were used for correlation analysis with pre-rating scores for each category. Results: Behavioural data revealed that saliency scores of non-consciously presented stimuli influenced dichotomic responses (beauty or non-beauty). MEG data showed that non-consciously presented portrait paintings induced spatiotemporally distributed low-frequency brain activities associated with aesthetic ratings, which were distinct between the biological and non-biological categories and conscious and non-conscious conditions. Conclusion: Aesthetic emotion holds evolutionary significance for humans. Neural pathways are sensitive to visual images that arouse aesthetic emotion in distinct ways for biological and non-biological categories, which are further influenced by consciousness. These differences likely reflect the diversity in mechanisms of aesthetic processing, such as processing fluency, active elaboration, and predictive processing. The aesthetic processing of non-conscious stimuli appears to be characterised by fluency-driven affective processing, while top-down regulatory processes are suppressed. This study provides the first empirical evidence supporting the evolutionary significance of aesthetic processing.

19.
Trials ; 25(1): 362, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38840210

ABSTRACT

BACKGROUND: Flash visual evoked potentials (FVEPs) are a reliable method for protecting visual function during spine surgery in prone position. However, the popularization and application of FVEPs remain limited due to the unclear influence of various anesthetics on FVEPs. Exploring the effects of anesthetic drugs on FVEP and establishing appropriate anesthesia maintenance methods are particularly important for promoting and applying FVEP. According to the conventional concept, inhaled narcotic drugs significantly affect the success of FVEP monitoring, FVEP extraction, and interpretation. Nonetheless, our previous study demonstrated that sevoflurane-propofol balanced anesthesia was a practicable regimen for FVEPs. Desflurane is widely used in general anesthesia for its rapid recovery properties. As the effect of desflurane on FVEP remains unclear, this trial will investigate the effect of different inhaled concentrations of desflurane anesthesia on amplitude of FVEPs during spine surgery, aiming to identify more feasible anesthesia schemes for the clinical application of FVEP. METHODS/ DESIGN: A total of 70 patients undergoing elective spinal surgery will be enrolled in this prospective, randomized controlled, open-label, patient-assessor-blinded, superiority trial and randomly assigned to the low inhaled concentration of desflurane group (LD group) maintained with desflurane-propofolremifentanil-balanced anesthesia or high inhaled concentration of desflurane group (HD group) maintained with desflurane-remifentanil anesthesia maintenance group at a ratio of 1:1. All patients will be monitored for intraoperative FVEPs, and the baseline will be measured half an hour after induction under total intravenous anesthesia (TIVA). After that, patients will receive 0.5 minimum alveolar concentration (MAC) of desflurane combined with propofol and remifentanil for anesthesia maintenance in the LD group, while 0.7-1.0 MAC of desflurane and remifentanil will be maintained in the HD group. The primary outcome is the N75-P100 amplitude 1 h after the induction of anesthesia. We intend to use the dual measure evaluation, dual data entry, and statistical analysis by double trained assessors to ensure the reliability and accuracy of the results. DISCUSSION: This randomized controlled trial aims to explore the superiority effect of low inhaled concentration of desflurane combined with propofolremifentanil-balanced anesthesia versus high inhaled concentration of desflurane combined with remifentanil anesthesia on amplitude of FVEPs. The study is meant to be published in a peer-reviewed journal and might guide the anesthetic regimen for FVEPs. The conclusion is expected to provide high-quality evidence for the effect of desflurane on FVEPs and aim to explore more feasible anesthesia schemes for the clinical application of FVEPs and visual function protection. TRIAL REGISTRATION: This study was registered on clinicaltrials.gov on July 15, 2022. CLINICALTRIALS: gov Identifier: NCT05465330.


Subject(s)
Anesthetics, Inhalation , Desflurane , Evoked Potentials, Visual , Intraoperative Neurophysiological Monitoring , Randomized Controlled Trials as Topic , Remifentanil , Spine , Humans , Desflurane/administration & dosage , Evoked Potentials, Visual/drug effects , Anesthetics, Inhalation/administration & dosage , Prospective Studies , Spine/surgery , Middle Aged , Intraoperative Neurophysiological Monitoring/methods , Adult , Male , Remifentanil/administration & dosage , Female , Propofol/administration & dosage , Young Adult , Aged , Anesthetics, Intravenous/administration & dosage , Adolescent , Time Factors , Orthopedic Procedures , Photic Stimulation
20.
ArXiv ; 2024 May 24.
Article in English | MEDLINE | ID: mdl-38827455

ABSTRACT

Background & Purpose: FLASH or ultra-high dose rate (UHDR) radiation therapy (RT) has gained attention in recent years for its ability to spare normal tissues relative to conventional dose rate (CDR) RT in various preclinical trials. However, clinical implementation of this promising treatment option has been limited because of the lack of availability of accelerators capable of delivering UHDR RT. Commercial options are finally reaching the market that produce electron beams with average dose rates of up to 1000 Gy/s. We established a framework for the acceptance, commissioning, and periodic quality assurance (QA) of electron FLASH units and present an example of commissioning. Methods: A protocol for acceptance, commissioning, and QA of UHDR linear accelerators was established by combining and adapting standards and professional recommendations for standard linear accelerators based on the experience with UHDR at four clinical centers that use different UHDR devices. Non-standard dosimetric beam parameters considered included pulse width, pulse repetition frequency, dose per pulse, and instantaneous dose rate, together with recommendations on how to acquire these measurements. Results: The 6- and 9-MeV beams of an UHDR electron device were commissioned by using this developed protocol. Measurements were acquired with a combination of ion chambers, beam current transformers (BCTs), and dose-rate-independent passive dosimeters. The unit was calibrated according to the concept of redundant dosimetry using a reference setup. Conclusions: This study provides detailed recommendations for the acceptance testing, commissioning, and routine QA of low-energy electron UHDR linear accelerators. The proposed framework is not limited to any specific unit, making it applicable to all existing eFLASH units in the market. Through practical insights and theoretical discourse, this document establishes a benchmark for the commissioning of UHDR devices for clinical use.

SELECTION OF CITATIONS
SEARCH DETAIL
...