1.
Rev. bras. oftalmol ; 81: e0043, 2022. tab, graf
Article in English | LILACS | ID: biblio-1387977

ABSTRACT

ABSTRACT Objective: To evaluate the efficacy of low-cost nucleus fragmenting forceps designed to reduce the use of ultrasound during phacoemulsification. Methods: A total of 60 pig eyes enucleated 10 hours before were placed in the microwave oven, at maximum power for 10 seconds, to form cataracts with hardness comparable to a grade IV nucleus in the Lens Opacities Classification System III. Cataract extraction was performed using the Centurion® phacoemulsifier (Alcon Laboratories, Geneve, Switzerland) and Leica M620 microscope. All eyes were submitted to the pre-chop technique dividing the nucleus into four parts. After the pre-chop, the quadrants in 30 eyes were phacoemulsified with the torsional mode and were fragmented in the remaining 30 eyes after the pre-chop was with the fragmentation forceps before torsional mode phacoemulsification. The device was calibrated for all eyes by applying the following parameters: 40% linear torsional phacoemulsification; intraocular pressure of 65 mmHg; the linear vacuum of 600 mmHg; aspiration flow of 40 ccs/minute. After each procedure, the following was recorded: cumulative dissipated energy; equivalent average torsional amplitude; equivalent average ultrasonic power; estimated aspirated fluid; ultrasound total time; and total aspiration time. Statistical analysis was performed using the Kruskal-Wallis test and the IBM Statistical Package for Social Sciences. The p-value <0.05 was considered statistically significant. Results: There was a statistically significant reduction favoring the use of the nucleus fragmenting forceps in all parameters, except for the average torsional amplitude. Conclusion: The use of the nucleus fragmenting forceps contributed to improving the efficacy of torsional phacoemulsification in enucleated pig eyes.


RESUMO Objetivo: Avaliar a eficácia de uma pinça fragmentadora de núcleo, de baixo custo, desenvolvida para reduzir o uso de ultrassom durante a emulsificação do núcleo. Métodos: Sessenta olhos de porco com 10 horas de enucleação foram colocados no forno de microondas, em potência máxima por 10 segundos, para a formação de catarata com dureza comparável à de um núcleo grau IV na Lens Opacities Classification System III. A extração da catarata foi realizada com o facoemulsificador Centurion® (Alcon Laboratories, Genebra, Suíça) e microscópio Leica M620. Todos os olhos foram submetidos a técnica de pre-chop, dividindo o núcleo em quatro partes. Em 30 olhos, após o pre-chop, foi feita a facoemulsificação dos quadrantes com o modo torsional e, nos outros 30 olhos, após o pre-chop, cada quadrante foi fragmentado com a pinça antes da facoemulsificação com o modo torsional. O aparelho foi calibrado para todos os olhos com os seguintes parâmetros: faco torsional linear 40%; pressão intraocular 65 mmHg; vácuo linear 600mmHg e fluxo de aspiração 40cc/minuto. Após cada procedimento, verificaram-se energia dissipada acumulada; média da amplitude do faco torsional; média equivalente do poder ultrassônico; líquido aspirado estimado; tempo total de ultrassom e tempo total de aspiração. A análise estatística foi realizada utilizando o teste de Kruskal-Wallis com o IBM Statistical Package for Social Sciences. Valor de p<0,05 foi considerado estatisticamente significante. Resultados: Houve redução estatisticamente significante em favor do uso da pinça fragmentadora de núcleo em todos os parâmetros, menos na média de amplitude do faco torsional. Conclusão: O uso da pinça fragmentadora de núcleo contribuiu para melhorar a eficácia do faco torsional em olhos de porco enucleados.


Subject(s)
Animals , Surgical Instruments , Ultrasonic Therapy , Phacoemulsification/instrumentation , Phacoemulsification/methods , Lens Nucleus, Crystalline/surgery , Sonication/adverse effects , Swine , Cataract/classification , Eye Enucleation
2.
Arq. bras. oftalmol ; Arq. bras. oftalmol;79(4): 218-221, July-Aug. 2016. tab
Article in English | LILACS | ID: lil-794582

ABSTRACT

ABSTRACT Purpose: To evaluate the results and complications of phacoemulsification surgery in eyes with posterior polar cataracts and compare the techniques of viscodissection and hydrodissection. Methods: The medical records of 29 consecutive patients (16 males, 13 females) with posterior polar cataracts (44 eyes) who had undergone cataract surgery were retrospectively reviewed. Patients were divided into two groups according to the technique used; viscodissection was applied to the experimental group (group 1) and hydrodissection to the control group (group 2). Results: The postoperative best corrected visual acuity (BCVA) was 0.19 ± 0.22 logMAR (mean ± standard deviation) (range 0.00-0.70) in group 1 and 0.25 ± 0.18 logMAR (range 0.00-0.70) in group 2. Although the mean postoperative BCVA in group 1 was greater than that in group 2, the difference was not statistically significant (p=0.165). The mean postoperative BCVA was significantly greater than the mean preoperative BCVA in both groups (p=0.00). Intraoperatively, posterior capsular rupture occurred during the removal of the cortex in three eyes (13%) of group 1 patients, with vitreous loss and anterior vitrectomy in one eye only. In group 2, six eyes (28.5%) presented posterior capsular rupture, and anterior vitrectomy was performed because of vitreous loss in three eyes. Although the percentage of posterior capsular rupture was greater in group 2, the difference was not statistically significant (p=0.207). Conclusions: Complications in posterior polar cataract surgeries can be overcome by being careful throughout the surgery and using proper techniques. Viscodissection may be better for avoiding posterior capsular rupture than hydrodissection.


RESUMO Objetivo: Avaliar os resultados e complicações da cirurgia de facoemulsificação em olhos com catarata polar posterior e comparar as técnicas de viscodissecção e hidrodissecção. Métodos: Os prontuários de 29 pacientes consecutivos (16 homens, 13 mulheres) com posterior cataratas polares (44 olhos), que haviam sido submetidos a cirurgia de catarata foram analisados retrospectivamente. Os pacientes foram divididos em dois grupos de acordo com a técnica utilizada; viscodissecção foi aplicada ao grupo experimental (grupo 1) e hidrodissecção para o grupo de controle (grupo 2). Resultados: No pós-operatório, a melhor acuidade visual corrigida (BCVA) foi 0,19 ± 0,22 logMAR (média ± desvio padrão) (variação 0,00-0,70) no grupo 1 e 0,25 ± 0,18 (0,00-0,70) logMAR no grupo 2. Embora a média da BCVA pós-operatória do grupo 1 tenha sido maior do que a do grupo 2, a diferença não foi estatisticamente significativa (p=0,165). A melhor acuidade visual corrigida pós-operatória foi significativamente melhor do que no pré-operatório, em ambos os grupos (p=0,00). No grupo 1, houve ruptura capsular posterior durante a remoção do córtex em três olhos (13%); houve perda vítrea e necessidade de vitrectomia anterior mas apenas em destes olhos. No grupo 2, a ruptura da cápsula posterior ocorreu em seis olhos (28,5%); vitrectomia anterior foi necessária após a perda vítrea em três destes olhos. Embora a porcentagem de ruptura da cápsula posterior tenha sido maior no grupo 2, a diferença não foi estatisticamente significativa (p=0,207). Conclusões: As complicações em cirurgias de catarata polar posterior podem ser superadas com cautela durante toda a cirurgia e usando técnicas adequadas. Viscodissecção é melhor para evitar a posterior ruptura capsular do que hidrodissecção.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Young Adult , Phacoemulsification/methods , Microdissection/methods , Postoperative Complications , Time Factors , Cataract/complications , Visual Acuity , Medical Records , Retrospective Studies , Risk Factors , Treatment Outcome , Statistics, Nonparametric , Phacoemulsification/adverse effects , Microdissection/adverse effects , Posterior Capsular Rupture, Ocular/etiology , Intraoperative Complications
3.
Arq. bras. oftalmol ; Arq. bras. oftalmol;78(1): 19-22, Jan-Feb/2015. tab, graf
Article in English | LILACS | ID: lil-741162

ABSTRACT

Purpose: To compare the efficiency of surgical procedures using three phaco tip designs in torsional phacoemulsification using the bevel-down technique. Methods: In this prospective, comparative, masked study, patients were randomly assigned to have torsional coaxial microincision cataract surgery using the mini-flared 45-degree Kelman tip, reversed mini-flared 30-degree Kelman tip, or Sidewinder 30-degree Kelman tip. Clinical measurements included preoperative and 3-month postoperative corrected distance visual acuity (CDVA), endothelial cell counts (ECC), and preoperative and 1-day postoperative central corneal thickness (CCT). Intraoperative measurements included phaco time, torsional time, aspiration time, case time, cumulative dissipated energy (CDE), and balanced salt solution volume (BSS). Results: The study evaluated 150 eyes of 150 patients. Intraoperatively, there was no statistically significant difference in cumulative dissipated energy, case time, torsional time, and aspiration time between the three tip configurations. However, less phaco time was used with the mini-flared 45-degree Kelman tip (p=0.02) than that with the Sidewinder 30-degree Kelman tip or reversed mini-flared 30-degree Kelman tip. The mini-flared 45-degree Kelman tip and the reversed mini-flared 30-degree Kelman tip required significantly less balanced salt solution volume than that required by the Sidewinder 30-degree Kelman tip (p=0.009). There was no statistically significant difference in corrected distance visual acuity and endothelial cell counts between tips 3 months postoperatively (p>0.05). Conclusion: All three tips were effective with no intraoperative complications. When using torsional phacoemulsification through microincisions and the prefracture technique with the bevel-down technique, the mini-flared 45-degree Kelman tip required a lower mean phaco time than the reversed mini-flared 30-degree Kelman tip and the Sidewinder 30-degree Kelman tip. .


Objetivo: Comparar a eficácia cirúrgica da facoemulsificação com tecnologia torcional utilizando 3 modelos diferentes de ponteiras. Métodos: Neste estudo prospectivo, randomizado, mascarado, os pacientes foram aleatoriamente distribuídos para serem submetidos a cirurgia de facoemulsificação coaxial torcional utilizando a ponteira Kelman mini-flared de 45 graus, ou Kelman reversed mini-flared de 30 graus ou Kelman Sidewinder de 30 graus. Os parâmetros avaliados incluíram: acuidade visual com correção (AVCC) para longe; contagem de células endoteliais (CCE) pré-operatória e pós-operatória, ao final de 3 meses; espessura corneana central (ECC) pré-operatória e no primeiro dia pós-operatório. Medidas intraoperatórias incluíram tempo de facoemulsificação, tempo de energia torcional, tempo da aspiração, tempo cirúrgico, energia dissipada acumulada (CDE) e volume de solução salina balanceada (BSS). Resultados: Este estudo avaliou 150 olhos de 150 pacientes. No intraoperatório, não foram observadas diferenças significativas na energia dissipada acumulada, tempo de facoemulsificação, tempo de energia torcional, e tempo de aspiração entre os 3 modelos de ponteira. No entanto, foi utilizando menos tempo de faco com a ponteira Kelman mini-flared de 45 graus (p=0,02) quando comparado às ponteiras Kelman Sidewinder de 30 graus e reversa mini-flared de 30 graus. A ponteira Kelman mini-flared de 45 graus e a reversa mini-flared de 30 graus utilizaram menos solução salina balanceada quando comparado à ponteira Sidewinder de 30 graus (p=0,009). Não foram observadas diferenças significativas na acuidade visual com correção, contagem de células endoteliais e espessura corneana central entre as diferentes ponteiras ao final do estudo (p=0,05). Conclusão: As 3 ponteiras foram eficazes e não apresentaram complicacões intraoperatórias. Quando foi utilizando o faco torcional através de microincisão com a técnica da pré-fratura, a ponteira Kelman mini-flared ...


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Cornea/surgery , Phacoemulsification/instrumentation , Cell Count , Equipment Design , Endothelium, Corneal/cytology , Intraoperative Period , Operative Time , Postoperative Period , Preoperative Care , Prospective Studies , Phacoemulsification/methods , Single-Blind Method , Treatment Outcome , Visual Acuity/physiology
4.
Arq. bras. oftalmol ; Arq. bras. oftalmol;77(1): 40-46, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-715552

ABSTRACT

Purpose: To compare the effectiveness of limbal relaxing incisions (LRI) with that of toric intraocular lens (IOL) implantation for the treatment of astigmatism during phacoemulsification using nonvectorial (predictability, safety, and efficacy) and vectorial analyses. Methods: This longitudinal observational case series assessed 62 eyes of 31 consecutive cataract patients with preoperative corneal astigmatism of 0.75-2.50 diopters (D) in both eyes. Patients were randomly assigned to 2 groups: a toric IOL group, which received toric IOLs in both eyes, and an LRI group, which received spherical IOLs associated with LRI placement in both eyes. All patients were evaluated at 1, 3, and 6 months after surgery, when refractive astigmatism analysis was performed using both nonvectorial and Alpins vectorial methods. Outcomes were assessed within each group and compared between groups. Results: The proportion of eyes within ±0.50 D of the intended correction at 3 and 6 months after surgery was 75% and 71.88%, respectively, in the LRI group and 40% and 66.67%, respectively, in the toric IOL group. In the remaining period, the proportion was greater in the toric IOL group. The safety index showed no difference at any time point. The efficacy index at 1 and 3 months after surgery was significantly higher in the toric IOL group (0.43 and 0.44, respectively) than in the LRI group (0.31 and 0.36, respectively). At 6 months after surgery, the status of eyes in the LRI group was as follows: 53.13% were undercorrected, 43.74% achieved the intended correction, and 3.13% were overcorrected. In the toric IOL group, 16.76% eyes were undercorrected, 76.67% achieved the intended correction, and 6.67% were overcorrected. The success rates for astigmatic surgery, astigmatism reduction at the intended axis, and astigmatism corrected were 43%, 62%, and 64%, respectively, in the LRI group and 57%, 81%, and 94%, respectively, in the toric IOL group. Conclusions: ...


Objetivo: Comparar incisões relaxantes limbares (IRL) e lentes intraoculares (LIO) tóricas tanto em termos não-vetoriais (efetividade, segurança e eficácia), quanto vetoriais no tratamento do astigmatismo por ocasião da facoemulsificação. Métodos: Estudo observacional longitudinal (série de casos) no qual foram avaliados 62 olhos de 31 pacientes consecutivos de catarata com astigmatismo corneano pré-operatório entre 0,75 e 2,50 dioptrias (D) para ambos os olhos. Os pacientes foram aleatoriamente distribuídos entre 2 grupos: "1" submetido a implante de lentes intraoculares AcrySof ToricTM em ambos os olhos e "2" com implante bilateral de lentes intraoculares tóricas AcrySof NaturalTM complementada por incisões relaxantes limbares. Todos os pacientes foram reavaliados com 1, 3 e 6 meses de pós-operatório, sendo feitas análises do astigmatismo refracional por métodos não-vetoriais, como pela análise vetorial de Alpins, interessando os resultados dentro de cada grupo e entre os grupos. Resultados: O porcentual de olhos entre ±0,50 D da correção pretendida no grupo incisões relaxantes limbares foi de 75 e 71,88%, respectivamente, em comparação aos 40 e 66,67% do grupo lentes intraoculares tóricas aos 3 e 6 meses de pós-operatório. Nos outros períodos avaliados, os porcentuais foram favoráveis ao grupo lentes intraoculares tóricas. O índice de segurança não demonstrou diferença em nenhum dos períodos. O índice de eficácia foi estatisticamente maior para o grupo lentes intraoculares tórica com 1 e 3 meses de pós-operatório (0,43 e 0,44), em comparação ao grupo incisões relaxantes limbares (0,31 e 0,36). Aos 6 meses, o porcentual de olhos, para o grupo incisões relaxantes limbares, foi: hipocorreção ...


Subject(s)
Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Astigmatism/surgery , Lens Implantation, Intraocular/methods , Phacoemulsification/methods , Astigmatism/complications , Cataract/complications , Follow-Up Studies , Longitudinal Studies , Lens Implantation, Intraocular/adverse effects , Treatment Outcome , Visual Acuity