Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 25
Filter
1.
Cureus ; 15(6): e40888, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37492847

ABSTRACT

Background Bronchoscopy is an essential procedure for evaluating, diagnosing, and treating pediatric respiratory diseases. In this study, we demonstrate the indications and contraindications of bronchoscopy done in a tertiary referral hospital, Al Qassimi Woman's and Children's Hospital (AQWCH) in Sharjah, United Arab Emirates (UAE), in order to achieve better service. This study aims to evaluate patients' characteristics, diagnostic and therapeutic indications, and complications of bronchoscopy. Material and method This retrospective chart review included children aged between one day and 13 years, admitted to AQWCH, who underwent bronchoscopy (rigid or flexible) procedures between January 2018 and December 2019. All patients were identified by using a computerized search of hospital discharge diagnosis, which was codified as "pediatric bronchoscopy, flexible, rigid, bronchoalveolar lavage". The main study outcome measure was to evaluate patients' characteristics, diagnostic or therapeutic indications, bronchoalveolar lavage (BAL) analysis, as well as complications of bronchoscopy at AQWCH.  Results There were 72 pediatric bronchoscopies (rigid and flexible) performed in patients aged less than 13 years old; the reason for bronchoscopy procedure was diagnostic in 51% and both diagnostic and therapeutic in 49%. Cough was the most common symptom (n=53; 74%), and chest recession was the most common clinical finding (n=46; 64%). Foreign body aspiration was the main indication (n=23; 32%), followed by stridor (26%). Consolidation was the most common radiological finding. Foreign body was the common finding, seen in 25% of bronchoscopies, followed by tracheomalacia in 17%. The suspected diagnosis was confirmed in 89%, and management change was needed in 54% of patients. The main complication during the procedure was desaturation (26%), and cough was the main post-bronchoscopy complication (14%). BAL was done for 28 (39%) patients, in which BAL culture was positive in 75%. Rigid bronchoscopy was done when foreign body aspiration was suspected based on positive history in 70%, abnormal physical examination in 60%, and chest X-ray abnormalities in 39% of patients. Sensitivity and specificity for patient history, physical examination, and chest X-ray were 80% and 83%, 66% and 60%, and 40% and 66 %, respectively. Conclusion Bronchoscopy is an important tool for evaluating, diagnosing, and treating pediatric respiratory diseases. While it is a safe procedure, it still needs a careful selection of patients as it is invasive.

2.
Cureus ; 15(5): e39074, 2023 May.
Article in English | MEDLINE | ID: mdl-37323356

ABSTRACT

Foreign body aspiration is of significant prevalence in the pediatric and young adult populations. After dental work, patients are more likely to develop pulmonary symptoms secondary to aspiration events within the tracheobronchial tree. Herein, we describe the clinical case of a 22-year-old man with a past medical history of epilepsy and tuberous sclerosis who presented to his primary care provider for chronic coughing and wheezing. With symptoms refractory to albuterol and control of allergies, radiography was obtained, revealing a 4.1 cm dental product in the right bronchus. We provide an overview of our retrieval method as well as a comparison of flexible and rigid bronchoscopies and the bronchoscopic tools available.

3.
Cureus ; 15(4): e37686, 2023 Apr.
Article in English | MEDLINE | ID: mdl-37206508

ABSTRACT

Endobronchial foreign body aspiration is a rare occurrence in adults, with a higher incidence in children. However, the possibility of such foreign body aspiration should not be overlooked in adult patients presenting with recurrent pneumonia symptoms, particularly when antibiotic treatment is ineffective. The diagnosis of occult endobronchial foreign body aspiration is challenging and requires a high degree of clinical suspicion, as it may not be associated with a history of aspiration. In this report, we present a case of recurrent pneumonia persisting for over two years, which was eventually diagnosed as an endobronchial foreign body due to occult pistachio shell aspiration. The foreign body was successfully removed through bronchoscopy. The diagnostic workup for recurrent pneumonia, including imaging and bronchoscopy, and the therapeutic management of endobronchial foreign body aspiration are discussed in detail. This case highlights the importance of considering endobronchial foreign body aspiration as a potential diagnosis in adult patients presenting with recurrent pneumonia, even in the absence of a history of aspiration. Early recognition and prompt intervention can prevent potential complications, including bronchiectasis, atelectasis, and respiratory failure.

4.
Indian J Crit Care Med ; 25(11): 1269-1274, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34866824

ABSTRACT

BACKGROUND: Percutaneous dilatational tracheostomy (PCDT) using fiber-optic bronchoscope (FOB) is a widely practiced technique, but its availability and cost remain a concern in nations with limited resources. Mini-surgical technique of PCDT incorporating minimal blunt dissection has shown improved results even without the use of FOB. The study is primarily intended to compare these two techniques and establish a safer cost-effective alternative to FOB-guided PCDTs. PATIENTS AND METHODS: This randomized comparative study [registered (CTRI/2018/04/013191)] was conducted on 120 mechanically ventilated patients. In 60 patients, mini-surgical PCDT (group-M) was performed with 2 cm longitudinal skin incision and blunt dissection till pretracheal fascia without FOB guidance using Portex-Ultraperc™ sets. In remaining 60 patients, PCDT was performed under FOB vision with similar skin incision (without blunt dissection) using Portex-Ultraperc™ sets (group-F). Two techniques were compared with regard to procedural time and percentage of complications occurred during or after the procedure. RESULTS: Procedure time [group-M: 6.30 ± 1.28 minutes; group-F: 14.43 ± 1.84 minutes (p <0.001)] and mean blood loss [group-M: 5.33 ± 1.69 mL; group-F: 6.87 ± 3.11 mL (p = 0.001)] was significantly less in group-M. Higher incidence of desaturation [group-M: 16.7%; group-F: 35% (p = 0.022)] was noted in group-F, whereas arrhythmias [group-M: 21.7%; group-F: 6.7% (p = 0.018)] were higher in group-M. There was no statistical difference in incidence of pneumothorax and subcutaneous emphysema. There was no incidence of posterior tracheal wall perforation in any of the patients. CONCLUSION: Mini-surgical technique is a faster alternative of FOB-guided PCDT with comparable incidence of complications. It can safely be used in intensive care units (ICUs) where FOB is not available. CLINICAL TRIAL REGISTRATION NUMBER: CTRI/2018/05/014307. NAME OF REGISTRY: Clinical Trials Registry of India (CTRI), URL-http://ctri.nic.in. HOW TO CITE THIS ARTICLE: Kumar A, Kohli A, Kachru N, Bhadoria P, Wadhawan S, Kumar D. Fiber-optic Bronchoscope-guided vs Mini-surgical Technique of Percutaneous Dilatational Tracheostomy in Intensive Care Units. Indian J Crit Care Med 2021;25(11):1269-1274.

6.
Cureus ; 13(6): e15501, 2021 Jun.
Article in English | MEDLINE | ID: mdl-34268032

ABSTRACT

Central airway obstruction often presents with airway narrowing of differing internal diameters. Conventional straight stents do not fit these airways well and are prone to migration. We present a series of cases where hourglass-shaped silicone stents were customized intra-operatively to fit airway obstructions of both malignant and non-malignant etiologies and to improve patient performance status. Modified hourglass stents are a versatile tool to manage inoperable airway obstruction with unique anatomical characteristics.

7.
Indian J Crit Care Med ; 24(5): 340-343, 2020 May.
Article in English | MEDLINE | ID: mdl-32728326

ABSTRACT

OBJECTIVE: In children, pulmonary and cardiac diseases are closely associated, and their integrated evaluation is important. Flexible fiber-optic bronchoscopy (FFB) can be used for both diagnostic and therapeutic purposes in pediatric cardiac intensive care units (PCICU). The objective of this study was to evaluate the utility of FFB in children with congenital heart disease (CHD). MATERIALS AND METHODS: A retrospective, descriptive study was conducted at a tertiary care center in pediatric patients who underwent FFB in PCICU over a period of 6 years (2012-2017). RESULTS: Total 71 bronchoscopies were done in 58 patients with CHD with median age and weight of 2.5 months and 3.4 kg, respectively. Total of 20 different cardiac lesions were present among patients who underwent FFB. While 38 (53.5%) and 30 (42.3%) procedures were performed in pre-op and postoperative patients, respectively, 3 intraoperative bronchoscopies were also performed. The main indications for FFB were persistent atelectasis (42/71), prolonged oxygen requirement (13/71), stridor (8/71), and suspected airway anomaly (6/71). Tracheobronchitis was the commonest bronchoscopy finding (51/71, 71.8%) followed by tracheobronchomalacia (27/71, 38.3%). Cause of stridor detected in 7/8 cases. Associated preoperative and postoperative respiratory complications were detected and necessary interventions were done. These included slide tracheoplasty (5/58), tracheostomy (5/58), antibiotic change based on bronchoalveolar lavage (BAL) cultures (11/71), and continued positive pressure ventilation (4/71). Nonconsequential complications were transient hypoxemia (10/71), bleeding (2/71), and transient bradycardia (1/71). CONCLUSION: Bedside FFB is a safe and a valuable diagnostic tool that also helps in guiding interventions in children with cardiac diseases. HOW TO CITE THIS ARTICLE: Sachdev A, Chhawchharia R, Gupta D, Gupta N, Joshi R, Agarwal N. Flexible Fiber-optic Bronchoscopy-directed Interventions in Children with Congenital Heart Diseases. Indian J Crit Care Med 2020;24(5):340-343.

8.
Lung India ; 36(6): 534-539, 2019.
Article in English | MEDLINE | ID: mdl-31670302

ABSTRACT

Diffuse alveolar hemorrhage (DAH) refers to the intra-alveolar accumulation of blood originating from the pulmonary microvasculature. This life-threatening condition is a medical emergency as patients often develop acute respiratory failure requiring invasive mechanical ventilation. This mandates for an early diagnosis with prompt and aggressive management strategies. A host of clinical disorders are known to cause DAH; however, warfarin-induced alveolar hemorrhage is a distinct clinical rarity. A search of the literature reveals few reports documenting this entity. A 27-year-old male presented with complaints of recent-onset hemoptysis and dyspnea. One month back, he was diagnosed with lower-limb deep-venous thrombosis and pulmonary embolism. He had been taking oral anticoagulants irregularly since then without monitoring of prothrombin time. Chest radiograph, done on presentation, revealed bilateral upper-lobe infiltrates, whereas computed tomography of the chest was suggestive of bilateral upper-lobe ground-glass opacities. Serial bronchoscopic alveolar lavage yielded samples which became progressively bloodier, whereas cytological evaluation of the sample revealed numerous alveolar macrophages with intracytoplasmic hemosiderin. A diagnosis of DAH due to warfarin was made, and the patient was administered Vitamin K followed by infusion of fresh frozen plasma. There was a marked clinical recovery, and the patient has been asymptomatic since then.

9.
Respir Med ; 146: 81-86, 2019 01.
Article in English | MEDLINE | ID: mdl-30665523

ABSTRACT

Pulmonary infections are frequent complications in abdominal solid-organ transplantation (aSOT) which may threaten patient and allograft survival. Accurate diagnosis and treatment of pulmonary infections in this population can be challenging. Immunosuppressive therapy not only increases the risk of acquiring opportunistic and non-opportunistic infections, but it also impairs the inflammatory responses associated with microbial invasion which in an otherwise normal host produce clinical and radiologic responses that allow for early identification of the offending pathogen. Serologic testing is not a reliable diagnostic modality. Direct microbiological sampling is often necessary to make a definitive diagnosis early in the clinical course to optimize timely, targeted therapy while reducing the risk of developing antimicrobial resistance, and minimize adverse effects of therapy, if any. Fiber-optic bronchoscopy (FOB) with bronchoalveolar lavage (BAL) or transbronchial lung biopsy (TBB) offers such diagnostic advantage and possesses a potential therapeutic value too. This comprehensive review discusses the potential benefits of FOB alongside its risks and complications, indications and contraindications, and techniques. Additionally, the essay highlights FOB's utility and yield specifically with regard to type and timing of infections in aSOT patients.


Subject(s)
Bronchoscopy/methods , Immunosuppressive Agents/adverse effects , Lung Diseases/diagnostic imaging , Respiratory Tract Infections/diagnostic imaging , Transplant Recipients/statistics & numerical data , Biopsy , Bronchoalveolar Lavage , Bronchoscopy/adverse effects , Fiber Optic Technology , Humans , Immunocompromised Host/immunology , Immunosuppressive Agents/therapeutic use , Inflammation/pathology , Lung Diseases/epidemiology , Lung Diseases/microbiology , Lung Diseases/pathology , Respiratory Tract Infections/epidemiology , Respiratory Tract Infections/etiology
10.
J Intensive Care Med ; 34(3): 191-196, 2019 03.
Article in English | MEDLINE | ID: mdl-28446075

ABSTRACT

OBJECTIVE: To compare the efficacy, safety, and incidence of complications between fiber-optic bronchoscopy-guided percutaneous dilatational tracheostomy (FOB-PDT) and ultrasound-guided percutaneous dilatational tracheostomy (US-PDT) and to determine whether US-PDT is a viable alternative to FOB-PDT. METHODS: This randomized prospective study was carried out in 80 patients who were randomly divided into US-PDT and FOB-PDT groups. Demographic data and Acute Physiology and Chronic Health Evaluation II (APACHE II), procedure duration, hemorrhage status, complications, procedure difficulty, displacement of entry location after US, and hemodynamic data were evaluated in both groups. Tracheal incision was performed with real-time US and a transverse probe position in the out-of-plane mode. RESULTS: No significant differences were observed between the 2 groups in terms of demographic data, oral intubation time, APACHE II values, difficulty of the procedure, or the number of needle interventions (P > .05). The mean hemorrhage ratio of the FOB-PDT group was significantly higher than that of the US-PDT group (P < .05). The entry location was changed in 6 patients in the US-PDT group following neck examination with US. The mean duration of the procedure for the FOB-PDT group was significantly longer than that for the US-PDT group (P < .05). CONCLUSION: Ultrasound-guided percutaneous dilatational tracheostomy is a safe procedure for critically ill patients and has the advantages of a low complication rate, short duration of procedure, being informative with regard to neck anatomy, and facilitating prevention of vascular puncture. Thus, US-PDT can be used as an alternative to FOB-PDT.

11.
Adv Exp Med Biol ; 1150: 43-52, 2019.
Article in English | MEDLINE | ID: mdl-30255302

ABSTRACT

Chronic obstructive pulmonary disease (COPD) is a progressive disease underlain by airway inflammation. Despite trials with new generations of anti-inflammatory drugs to alleviate the disease burden, the effective curative treatment remains elusive. In this context, the aim of this study was to assess the influence of simvastatin, a leading member of the family of 3-hydroxy-3-methylglutaryl coenzyme A (HMG-CoA) reductase inhibitors, known to display anti-inflammatory and immunomodulatory activity, on symptoms and lung function, as well as the proportion of inflammatory cells, cytokines, proteolytic enzymes, and surfactant protein D (SP-D) content in bronchoalveolar lavage fluid (BALF) in COPD patients. There were 50 patients with moderate-to-severe airway obstructions included into the study, subdivided into simvastatin-treated (Zocor - MSD; 40 mg daily) and control simvastatin-untreated groups, other treatment being equal. Pulmonary functions tests and bronchofiberoscopy with BALF procedure were performed before and after 3-month-long treatment in both groups. The major finding was that simvastatin treatment caused a distinct increase in the airway content of SP-D. Further effects, albeit smaller in magnitude, consisted of reductions in the proportion of airway neutrophils and in MMP-9 content, all with a benefit of improved score in the disease activity assessment test. There were no appreciable changes noted in lung function or dyspnea perception, which could be ascribed to simvastatin treatment. We conclude that statin's anti-inflammatory and surfactant homeostasis preserving properties may offer promise as an adjunctive treatment in COPD patients. The SP-D content in BALF has a potential to become a marker of COPD inflammatory activity and treatment monitoring.


Subject(s)
Bronchoalveolar Lavage Fluid/chemistry , Hydroxymethylglutaryl-CoA Reductase Inhibitors/therapeutic use , Pulmonary Disease, Chronic Obstructive/drug therapy , Pulmonary Disease, Chronic Obstructive/metabolism , Pulmonary Surfactant-Associated Protein D/analysis , Simvastatin/therapeutic use , Anti-Inflammatory Agents/administration & dosage , Biomarkers/metabolism , Humans , Lung , Pulmonary Surfactant-Associated Protein D/metabolism , Treatment Outcome
12.
Ann Thorac Med ; 13(3): 182-189, 2018.
Article in English | MEDLINE | ID: mdl-30123338

ABSTRACT

PURPOSE: The purpose of this study is to investigate the effect of homogeneous/heterogeneous (necrotic) involvement and maximum standardized uptake value (SUVmax) value of the lesion on positron emission tomography-computed tomography (PET-CT) of patients who underwent fiberoptic bronchoscopy (FOB) for prediagnosis of lung cancer and biopsy for endobronchial lesion on the diagnostic success of biopsy procedure. METHODS: Between January 2014 and December 2016, patients with final diagnosis of pulmonary malignancy as determined by FOB biopsy and patients who failed to be diagnosed by FOB biopsy and diagnosed with pulmonary malignancy by a different diagnostic method were examined. These patients were divided into two groups as those with diagnosis by FOB biopsy (Group 1) and those who failed to be diagnosed by this method and diagnosed with pulmonary malignancy by a different diagnostic method (Group 2). The SUVmax values of the two groups were compared with lesion characteristics of homogeneous, heterogeneous involvement/presence of necrotic component as shown by PET-CT. Group data were assessed by Chi-square test and Mann-Whitney U-test. In all tests, P < 0.05 was considered significant. FINDINGS: A total of 193 participants with a mean age of 61 ± 9.4 were included in the study. There were 128 (66.3%) cases in Group 1 and 65 (33.7%) cases in Group 2. The mean SUVmax value was 16.4 in Group 1 and 15.1 in Group 2. There was no statistically significant difference between the two groups (P = 0.329). Homogeneous involvement was present in 103 (80.3%) cases in Group 1 versus 42 (64.6%) cases in Group 2. In the presence of homogeneous PET-CT involvement, diagnosis rate by biopsy was significantly higher (P = 0.016). CONCLUSION: We concluded that the high SUVmax value of the mass lesion on PET-CT did not increase the diagnostic value of the biopsy procedure in patients prediagnosed with lung cancer and that the diagnostic success of FOB biopsy was poor in cases where PET-CT showed heterogeneous involvement of the mass lesion.

13.
Adv Respir Med ; 86(1): 13-16, 2018.
Article in English | MEDLINE | ID: mdl-29490417

ABSTRACT

INTRODUCTION: Fiber-optic bronchoscopy (FOB) is commonly performed in the first line in diagnostic process of haemoptysis. However, lots of evidences suggest that in haemoptysis FOB do not always provide additional, useful information to radiological diagnostics. Therefore, this study aimed to evaluate the validity of performing FOB as a method of choice in first line diagnostics of haemoptysis. MATERIAL AND METHODS: Data comprised consecutively collected results from patients referred for FOB assessment for clinical purposes were retrospectively analysed. We included all examinations, which were performed due to haemoptysis as the only indication, excluding any other lung-related conditions. RESULTS: 114 patients were finally included to the study. The median age was 59 (IQR: 46-64.75). Active bleeding was visualized during examination of 13 (11.4%) patients. Patients with active bleeding did not differ significantly according to age: 59 (54-69) vs 59 (45-64) years; W = 532.5, p-value = 0.27, and gender: c2 = 1.68, p-value = 0.2. On the other hand, in 29 (25.44%) patients, FOB revealed no visible abnormalities. This subgroup of patients was significantly younger - 46 (34-62) years vs 60 (53-67) years; W = 782, p-value = 0.003. CONCLUSION: Low number of visualized active bleeding sites suggest overuse of bronchoscopy in diagnosis of haemoptysis. Indications for this examination should be reconsidered especially in young patients with non-massive haemoptysis.


Subject(s)
Bronchoscopy/methods , Hemoptysis/diagnostic imaging , Hemoptysis/pathology , Severity of Illness Index , Age Factors , Aged , Bronchoscopy/adverse effects , Female , Humans , Male , Middle Aged , Retrospective Studies , Tomography, X-Ray Computed
14.
Adv Exp Med Biol ; 1047: 41-52, 2018.
Article in English | MEDLINE | ID: mdl-29181828

ABSTRACT

Inflammation in the bronchial respiratory tract and lung parenchyma underlies the pathogenesis of chronic obstructive pulmonary disease (COPD). It consists of effector cell infiltration, changes in reticular basement membrane (RBM) thickness, and the content of inflammatory mediators. The aim of this study was to assess the influence of inhaled corticosteroids (ICS) on the number of inflammatory cells and RBM thickness in bronchial biopsies, and pulmonary function in patients with moderate COPD. Twenty four patients with newly diagnosed COPD were included into the study. Pulmonary function tests and fiber optic bronchoscopy with bronchial biopsies were performed before and after 12-month treatment in two groups: ICS- group (LABA plus anticholinergics) and ICS+ group (LABA plus anticholinergics plus ICS). We found that the addition of inhaled corticosteroids to the therapeutic regimen contributed to a reduction of RBM thickness, inflammation, and lung hyperinflation. The intensity of bronchial inflammatory infiltration had little effect on lung function. In conclusion, RBM thickness, an airway wall remodeling element, does not significantly affect the degree of airflow limitation.


Subject(s)
Adrenal Cortex Hormones/therapeutic use , Bronchi/drug effects , Bronchodilator Agents/therapeutic use , Inflammation/drug therapy , Lung/drug effects , Pulmonary Disease, Chronic Obstructive/drug therapy , Administration, Inhalation , Adrenal Cortex Hormones/administration & dosage , Aged , Bronchi/physiopathology , Bronchodilator Agents/administration & dosage , Bronchoscopy , Female , Humans , Inflammation/physiopathology , Lung/physiopathology , Male , Middle Aged , Pulmonary Disease, Chronic Obstructive/physiopathology , Respiratory Function Tests , Treatment Outcome
15.
Indian J Crit Care Med ; 21(9): 613-615, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28970665

ABSTRACT

The Janus mask is a full face mask designed for providing noninvasive ventilation (NIV) during any kind of upper endoscopies (e.g., fiber-optic bronchoscopy, gastrointestinal endoscopy, and transesophageal echocardiography). Due to its unique conformation, its use can be considered for both elective and urgent endoscopic procedures in high-risk patients. In this case report, we present a patient with acute respiratory failure who underwent two consecutive different endoscopic procedures (fiber-optic bronchoscopy and gastrointestinal endoscopy) during continuous positive airway pressure support by means of this novel NIV mask, thus avoiding tracheal intubation and at the same time, improving his respiratory condition.

16.
Anaesth Crit Care Pain Med ; 36(5): 273-277, 2017 Oct.
Article in English | MEDLINE | ID: mdl-27867133

ABSTRACT

INTRODUCTION: Sedation optimizes patient comfort and ease of execution during fiber optic bronchoscopy (FOB). Our objective was to describe the safety and efficacy of remifentanil-TCI during FOB in non-intubated, hypoxaemic, thoracic surgery ICU patients. METHODS: Consecutive spontaneously breathing adults requiring FOB after thoracic surgery were included if they had hypoxaemia (PaO2/FiO2<300mmHg or need for non-invasive ventilation [NIV]) and prior FOB failure under topical anaesthesia. The remifentanil initial target was chosen at 1ng/mL brain effect-site concentration (Cet), then titrated to 0.5ng/mL Cet increments according to patient comfort and coughing. Outcomes were patient-reported pain and discomfort (Visual Analogue Scale scores), ventilatory support intensification within 24hours after bronchoscopy, and ease of FOB execution. RESULTS: Thirty-nine patients were included; all had a successful FOB. Their median PO2/FiO2 before starting FOB was 187±84mmHg and 24 patients received NIV. Median [interquartile range] pain scores were not different before and after FOB (1.0 [0.0-3.0] and 0.0 [0.0-2.0], respectively). Discomfort was reported as absent or minimal by 27 patients (69%; 95% confidence interval [95% CI], 54-81%) and as bothersome but tolerable by 12 patients (31%; 95% CI, 19-46%). Mean FiO2 returned to baseline within 2hours after FOB in 30 patients; the remaining 9 patients (23%; 95% CI, 13-38%) received ventilatory support intensification. Ease of execution was good or very good in 34 patients (87%; 95% CI, 73-94%), acceptable in 4 patients, and poor in 1 patient (persistent cough). CONCLUSION: Sedation with remifentanil-TCI during FOB with prior failure under topical anaesthesia alone was effective and acceptably safe in non-intubated hypoxaemic thoracic surgery patients.


Subject(s)
Bronchoscopy/instrumentation , Bronchoscopy/methods , Critical Care/methods , Fiber Optic Technology , Hypnotics and Sedatives/administration & dosage , Hypoxia/therapy , Piperidines/administration & dosage , Respiratory Insufficiency/therapy , Adult , Aged , Cohort Studies , Critical Illness , Female , Humans , Hypoxia/blood , Infusions, Intravenous , Male , Middle Aged , Pain/etiology , Pain Measurement , Prospective Studies , Remifentanil , Respiratory Insufficiency/blood , Thoracic Surgical Procedures/methods
17.
J Clin Diagn Res ; 10(3): OC07-10, 2016 Mar.
Article in English | MEDLINE | ID: mdl-27134911

ABSTRACT

INTRODUCTION: Tuberculosis is one of the most important public health problem worldwide. Detecting patients with active pulmonary Koch's disease is an important component of tuberculosis control programs. However, at times in patients even with a compatible clinical picture, sputum smears do not reveal acid-fast bacilli and smear-negative pulmonary tuberculosis remains a common problem. AIM: The present study is aimed to compare the results of induced sputum and bronchial washings smear in patients suspected to have sputum smear negative pulmonary tuberculosis. MATERIALS AND METHODS: A prospective study conducted from August 2014 to July 2015, comprising 120 patients fulfilling study criteria. Patients with respiratory symptoms and chest roentgenogram suspicious of pulmonary tuberculosis with no previous history of anti-tuberculosis treatment and two spontaneous sputum smear samples negative for acid fast bacilli were included. Patients with active haemoptysis and sputum positive were excluded from the study. Sputum induction was done by using 5-10 ml of 3% hypertonic saline through ultrasonic nebulizer taking safety precautions. All the patient underwent fibreoptic bronchoscopy after six hours fasting on the same day. About 20 ml of normal saline instilled into the suspected pathology area and washings were taken with gentle suction. The sample processing and fluorescent staining for acid fast bacilli was done in a designated microscopy lab. RESULTS: Out of 120 sputum smear negative pulmonary tuberculosis patients, induced sputum smear examination detected acid fast bacilli in 76 patients (63.3%) and acid fast bacilli detected from bronchial washings in 94 patients (78.3%). Smear positivity was higher in cavitary and infiltrative lesions as compared to consolidation and infrahilar pattern disease. CONCLUSION: Even though both induced sputum and bronchial washings procedures were valuable for the diagnosis of sputum smear negative, sputum induction with hypertonic saline should be the initial procedure of choice, which can be repeated twice / thrice in a day or two consecutive days. If the patient still remains induced sputum smear negative and if the clinical probability of tuberculosis is high, starting anti-tuberculosis treatment and closely monitoring patient and reserving bronchoscopy to those patients who do not improve and to exclude alternative diagnosis seems to be a practically useful approach.

18.
Chest ; 149(4): e95-7, 2016 Apr.
Article in English | MEDLINE | ID: mdl-27055718

ABSTRACT

Bronchial thermoplasty has been found to be a safe and effective therapy for severe asthma. We report the case of a mediastinal hematoma and hemothorax developing in a 66-year-old woman several days after an uneventful bronchial thermoplasty of the right lower lobe. Evaluation revealed a bleeding right bronchial artery pseudoaneurysm. Pseudoaneuryms have been reported in association with other procedures involving the therapeutic application of thermal energy, and a single case of hemoptysis requiring bronchial artery embolization occurred in a clinical trial of bronchial thermoplasty. However, bronchial artery pseudoaneurysm with hemomediastinum and hemothorax has not previously been reported after bronchial thermoplasty.


Subject(s)
Aneurysm, False/diagnostic imaging , Asthma/surgery , Bronchi/surgery , Bronchial Arteries/diagnostic imaging , Hemorrhage/diagnostic imaging , Hemothorax/diagnostic imaging , Mediastinal Diseases/diagnostic imaging , Postoperative Complications/diagnostic imaging , Aged , Aneurysm, False/therapy , Angiography , Bronchoscopy , Catheter Ablation , Embolization, Therapeutic , Female , Hemorrhage/therapy , Hemothorax/therapy , Humans , Mediastinal Diseases/therapy , Postoperative Complications/therapy , Tomography, X-Ray Computed
19.
Clin Chest Med ; 35(4): 697-712, 2014 Dec.
Article in English | MEDLINE | ID: mdl-25453419

ABSTRACT

Immunosuppression predisposes the host to development of pulmonary infections, which can lead to respiratory failure and the development of acute respiratory distress syndrome (ARDS). There are multiple mechanisms by which a host can be immunosuppressed and each is associated with specific infectious pathogens. Early invasive diagnostic modalities such as fiber-optic bronchoscopy with bronchoalveolar lavage, transbronchial biopsy, and open lung biopsy are complementary to serologic and noninvasive studies and assist in rapidly establishing an accurate diagnosis, which allows initiation of appropriate therapy and may improve outcomes with relative safety.


Subject(s)
Immunocompromised Host , Respiratory Distress Syndrome/diagnosis , Bronchi/pathology , Bronchoalveolar Lavage , Bronchoscopy , Fiber Optic Technology , Humans , Lung/pathology , Respiratory Distress Syndrome/complications
20.
Burns ; 40(7): 1308-15, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25112807

ABSTRACT

PURPOSE: Compare virtual bronchoscopy (VB) to fiberoptic bronchoscopy (FOB) for scoring smoke inhalation injury (SII). METHODS: Swine underwent computerized tomography (CT) with VB and FOB before (0) and 24 and 48 h after SII. VB and FOB images were scored by 5 providers off line. RESULTS: FOB and VB scores increased over time (p<0.001) with FOB scoring higher than VB at 0 (0.30±0.79 vs. 0.03±0.17), 24 h (4.21±1.68 vs. 2.47±1.50), and 48h (4.55±1.83 vs. 1.94±1.29). FOB and VB showed association with PaO2-to-FiO2 ratios (PFR) with areas under receiver operating characteristic curves (ROC): for PFR≤300, VB 0.830, FOB 0.863; for PFR≤200, VB 0.794, FOB 0.825; for PFR≤100, VB 0.747, FOB 0.777 (all p<0.001). FOB showed 80.3% specificity, 77% sensitivity, 88.8% negative-predictive value (NPV), and 62.3% positive-predictive value (PPV) for PFR≤300 and VB showed 67.2% specificity, 85.5% sensitivity, 91.3% NPV, and 53.4% PPV. CONCLUSIONS: VB provided similar injury severity scores to FOB, correlated with PFR, and reliably detected airway narrowing. VB performed during admission CT may be a useful screening tool specifically to demonstrate airway narrowing induced by SII.


Subject(s)
Bronchoscopy , Lung/diagnostic imaging , Smoke Inhalation Injury/diagnosis , Tomography, X-Ray Computed , Animals , Female , Sensitivity and Specificity , Severity of Illness Index , Smoke Inhalation Injury/diagnostic imaging , Swine
SELECTION OF CITATIONS
SEARCH DETAIL
...