Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
Rev. cuba. ortop. traumatol ; 37(4)dic. 2023. ilus
Article in Spanish | LILACS, CUMED | ID: biblio-1559945

ABSTRACT

Introducción: Las fracturas complejas de fémur distal AO/AOT tipo 33C3.3 constituyen un reto para los ortopedistas debido a la dificultad de su tratamiento y las complicaciones asociadas. El planeamiento y procedimiento quirúrgicos emplean placas condilares, pero estas se asocian a la pérdida de la fijación y al colapso de la reducción. Objetivo: Describir la planificación preoperatoria de una fractura de fémur distal AO/AOT 33C3.3 con bioimpresión 3D y reconstrucción por computadora. Presentación del caso: Paciente masculino de 34 años con fractura izquierda conminuta del fémur distal, AO/AOT tipo 33C3.3, por un accidente de tránsito. El planeamiento y el tratamiento quirúrgicos se realizaron exitosamente con la impresión y reconstrucción de biomodelos 3D. Basados en las imágenes tomográficas del paciente, se identificaron los principales fragmentos, la secuencia de reducción, la cantidad y la posición de los implantes a utilizar. Conclusiones: La planificación preoperatoria resulta una etapa de vital importancia en el manejo de fracturas complejas. Las técnicas convencionales pueden optimizarse con la cirugía asistida por computadora y reconstrucción con biomodelos 3D impresos. Esta novedosa propuesta permitirá el adecuado uso de materiales, una óptima secuencia de reducción, mejor estabilidad de la fractura y menor riesgo de complicaciones quirúrgicas(AU)


Introduction: Complex distal femur fractures AO/AOT type 33C3.3 constitute a challenge for orthopedists due to the difficulty of their treatment and associated complications. The surgical planning and procedure use condylar plates; but these are associated with loss of fixation and collapse of the reduction. Objective: To describe preoperative planning for an AO/AOT 33C3.3 distal femur fracture with 3D bioprinting and computer reconstruction. Case report: The case of a 34-year-old male patient is reported. He has comminuted left fracture of the distal femur, AO/AOT type 33C3.3, due to a traffic accident. Surgical planning and treatment were successfully performed with 3D biomodel printing and reconstruction. Based on the patient's tomographic images, the main fragments, the reduction sequence, the number and position of the implants to be used were identified. Conclusions: Preoperative planning is a critically important stage in managing complex fractures. Conventional techniques can be optimized with computer-assisted surgery and reconstruction with 3D printed biomodels. This novel proposal will allow the appropriate use of materials, optimal reduction sequence, better stability of the fracture and lower risk of surgical complications(AU)


Subject(s)
Humans , Male , Adult , Accidents, Traffic , Surgery, Computer-Assisted/instrumentation , Femoral Fractures/surgery , Bioprinting/methods , Planning
2.
Rev. medica electron ; 38(3)may.-jun. 2016. ilus, tab
Article in Spanish | CUMED | ID: cum-63534

ABSTRACT

Introducción: las fracturas de tibia producidas por mecanismo de alta energía pueden provocar áreas de defectos, que llevan a pseudoartrosis o infección ósea. Por esto, se buscan nuevas alternativas para la solución de estos defectos óseos, entre ellos el uso del biomaterial hidroxiapatita coralina porosa HAP-200® como andamiaje en el tratamiento de estas fracturas. Objetivos: describir la eficacia de la HAP-200® como andamiaje. Material y métodos: se realizó un estudio de tipo descriptivo, longitudinal, que incluyó la totalidad de pacientes (13) atendidos por fracturas complejas de la tibia, desde enero de 1994 hasta el 2010. Fueron tratados con diversos materiales de osteosíntesis e injerto de HAP-200® como andamiaje en la zona de defecto óseo, y evaluados evolutivamente por consulta durante 10 años. En el estudio fueron empleadas las clasificaciones del Sistema Asociación para el Estudio de la Fijación Interna y la de Gustilo y Anderson en las fracturas abiertas; y las clasificaciones del Sistema Asociación para el Estudio de la Fijación Interna y la de Tscherne y Gotze para la evaluación de partes blandas en las fracturas cerradas. Se confeccionó una base de datos mediante el paquete estadístico SPSS 1.14, para cumplir los objetivos trazados. Se realizó el consentimiento informado a cada paciente. Resultados: el 76,9 por ciento correspondió al sexo masculino. Se logró la curación ósea en el 92,3 por ciento. El período de curación tuvo una duración media de 16 semanas en las fracturas cerradas, y de 20 semanas en las expuestas. Conclusiones: los resultados demuestran la validez e importancia de la HAP-200® como un biomaterial osteoconductor(AU)


Background: tibia fracture produced by high energy mechanisms could provoke areas of defects leading to pseudoarthrosis or bone infection. Therefore, new alternatives are looked for to solve these bone defects, among them the usage of the biomaterial porous coral hydroxyapatite HAP-200® as scaffolding in the treatment of these complex fractures. Aims: describing the efficacy of HAP-200® as scaffolding.Materials and methods: a descriptive, longitudinal study was carried out, including the total of the patients attended by complex tibia fractures (13 patients), from January 1994 to 2010. They were treated with several materials of osteosyntheses and coral hydroxyapatite grafts as scaffolding in the bone defects area and evolutively evaluated in consultation during a period of 10 years. In the study, there they were used the classifications of the System Association for the Study of the Internal Fixation and the Gustilo and Anderson one in open fractures; and the System Association for the Study of the Internal Fixation and the Tscherne and Gotze one for the evaluation of the soft parts in closed fractures. A database was elaborated using the statistical packet SPSS 1.14, for fulfilling the planed aims. The informed consent of each patient was obtained. Outcomes: 76,9 percent of the cases dealt with male patients. Bone healing was achieved in 92,3 percent of the patients. The healing period lasted an average of 16 weeks in closed fractures, and 20 weeks in the exposed ones. Conclusions: the outcomes show the validity and importance of HAP-200® as bone conductor biomaterial(AU)


Subject(s)
Humans , Male , Female , Adolescent , Young Adult , Adult , Tibial Fractures/surgery , Tibial Fractures/therapy , Biocompatible Materials/therapeutic use , Fracture Fixation, Internal , Epidemiology, Descriptive , Longitudinal Studies
3.
Rev. venez. cir. ortop. traumatol ; 46(1)jun 2014. ilus, tab
Article in Spanish | LILACS, LIVECS | ID: biblio-1254609

ABSTRACT

Introducción: El tratamiento de las fracturas articulares complejas del tercio distal del radio con extensión metafisiaria representan un reto terapéutico. Una opción de tratamiento es la fijación interna "tipo puente" transarticular dorsal con placa. Material y métodos: Nueve pacientes fueron incluidos en el estudio. Se utilizaron placas DCP, LC-DCP y LCP de 3,5mm Ø de 12, 14 y 16 orificios. El seguimiento fue de 8,33 ± (6-14) meses. Para la valoración de resultados se utilizó la escala radiológica de Montoya y las escalas funcionales "Mayo Wrist Score" y "Quick Dash". Resultados: Todas las fracturas consolidaron en un promedio de 79,11 días. A los 6 meses del seguimiento, el promedio de flexión de la muñeca fue 48º, 49° de extensión, 65° de supinación y 64° de pronación. Según la escala de Montoya el 66,67% presentó consolidación de la fractura Grado III. Según el Mayo Wrist Score 55,56% obtuvieron un resultado satisfactorio. Según el Quick Dash se alcanzó un promedio de 20,21 puntos de discapacidad. Discusión: El uso de la fijación interna transarticular dorsal con la placa 3,5 mm Ø puede ser una técnica efectiva para el tratamiento de fracturas articulares complejas de radio distal. Esta técnica debe ser acompañada de un esquema de rehabilitación post operatorio agresivo(AU)


Introduction: The treatment of complex articular of distal radius fractures with metaphyseal extension represent a therapeutic challenge. One treatment option is "bridge type" internal transarticular fixation with dorsal plate. Material and methods: Nine patients were included. 12, 14 and 16 holes DCP, LC-DCP and LCP plates 3.5 mm Ø were used. The mean follow-up was 8.33 ± (6-14) months. For the assessment of the radiological results Montoya scale was used, and for functional results "Mayo Wrist Score" and "Quick DASH". Results: All fractures healed at an average of 79.11 days. At 6 months follow-up, the average wrist flexion was 48°, with 49° of extension , 65° of supination and 64° of pronation. 66.67% reach Grade III fracture by Montoya scale. 55.56 % obtained a satisfactory result according to Mayo Wrist Score. According to Quick Dash, mean 20,21 points disabilities was reached. Discussion: The use of transarticular internal fixation with dorsal 3.5 mm Ø plate can be an effective technique for the treatment of complex articular fractures of the distal radius. This technique should be accompanied by an outline of aggressive post operative rehabilitation(AU)


Subject(s)
Humans , Male , Female , Adolescent , Radius Fractures , Fractures, Bone , Fracture Fixation, Internal , Patients , Surgical Procedures, Operative , Therapeutics , Wrist , Bone Plates
SELECTION OF CITATIONS
SEARCH DETAIL
...